• Title/Summary/Keyword: RF characteristics test

Search Result 105, Processing Time 0.029 seconds

A Study of Micro, High-Performance Solenoid-Type RF Chip Inductor (Solenoid 형태의 소형.고성능 RF Chip 인덕터에 대한 연구)

  • Kim, Jae-Uk;Yun, Ui-Jung;Jeong, Yeong-Chang;Hong, Cheol-Ho;Seo, Won-Chang
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.5
    • /
    • pp.283-288
    • /
    • 2000
  • In this work, small-size, high-performance simple solenoid-type RF chip inductors utilizing an Al2O3 core material were investigated. Copper (Cu) wire with $40\mum$ diameter was used as the coils and the size of the chip inductor fabricated in this work was $2.1mm\times1.5mm\times1.0mm$. The external current source was applied after bonding Cu coil leads to gold pads electro-plated on each end of backsides of a core material. High frequency characteristics of the inductance (L), quality factor (Q), and impedance (Z) of developed inductors were measured using an RF Impedance/Material Analyzer (HP4291B with HP16193A test fixture). This HP4291B was also used to obtain the equivalent circuit and its circuit parameters of the chip inductors. This HP4291B was also used to obtain the equivalent circuit and its circuit parameters of the chip inductors. The developed inductors have the self-resonant frequency (SRF) of 1.1 to 3.1 GHz and exhibit L of 22 to 150 nH. The L of the inductors decreases with increasing the SRF. The Z of the inductors has the maximum value at the SRF and the inductors have the quality factor of 70 to 97 in the frequency range of 500 MHz to 1.5 GHz.

  • PDF

Internal Object Detection Monitoring System in Reinforced Concrete Structure using UWB-RF (UWB-RF를 이용한 콘크리트 구조물의 내부 물체 검출 모니터링 시스템)

  • Park, Dae-Hyuck;Kang, Eui-Sun
    • Journal of Digital Contents Society
    • /
    • v.18 no.7
    • /
    • pp.1457-1464
    • /
    • 2017
  • This paper is to introduce the a system which monitors and detects the object position in reinforced the concrete structure using UWB-RF. This system is able to check any changes in the inside of the concrete structure using its penetration and reflection characteristics and it can also numerically measure the position of rebar in the concrete structure. For the verification of the performance of this system, we set up the internal compositions of concrete in 3 different types of test-bed. On the other hand, for the measuring of the location of rebar, which varies depending on the type of structure, the software which shows the distance in the structure were used. The result shows that the position in the concrete could be measured within the tolerance of ${\pm}1{\sim}4mm$ depending on the type of structure in the concrete.

Utilizing the GOA-RF hybrid model, predicting the CPT-based pile set-up parameters

  • Zhao, Zhilong;Chen, Simin;Zhang, Dengke;Peng, Bin;Li, Xuyang;Zheng, Qian
    • Geomechanics and Engineering
    • /
    • v.31 no.1
    • /
    • pp.113-127
    • /
    • 2022
  • The undrained shear strength of soil is considered one of the engineering parameters of utmost significance in geotechnical design methods. In-situ experiments like cone penetration tests (CPT) have been used in the last several years to estimate the undrained shear strength depending on the characteristics of the soil. Nevertheless, the majority of these techniques rely on correlation presumptions, which may lead to uneven accuracy. This research's general aim is to extend a new united soft computing model, which is a combination of random forest (RF) with grasshopper optimization algorithm (GOA) to the pile set-up parameters' better approximation from CPT, based on two different types of data as inputs. Data type 1 contains pile parameters, and data type 2 consists of soil properties. The contribution of this article is that hybrid GOA - RF for the first time, was suggested to forecast the pile set-up parameter from CPT. In order to do this, CPT data and related bore log data were gathered from 70 various locations across Louisiana. With an R2 greater than 0.9098, which denotes the permissible relationship between measured and anticipated values, the results demonstrated that both models perform well in forecasting the set-up parameter. It is comprehensible that, in the training and testing step, the model with data type 2 has finer capability than the model using data type 1, with R2 and RMSE are 0.9272 and 0.0305 for the training step and 0.9182 and 0.0415 for the testing step. All in all, the models' results depict that the A parameter could be forecasted with adequate precision from the CPT data with the usage of hybrid GOA - RF models. However, the RF model with soil features as input parameters results in a finer commentary of pile set-up parameters.

Anodic bonding Characteristics of MLCA to Si-wafer Using Evaporated Pyrex #7740 Glass Thin-Films for MEMS Applications (파이렉스 #7740 유리박막을 이용한 MEMS용 MLCA와 Si기판의 양극접합 특성)

  • Chung, Gwiy-Sang;Kim, Jae-Min;Yoon, Suk-Jin
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.6
    • /
    • pp.265-272
    • /
    • 2003
  • This paper describes anodic bonding characteristics of MLCA (Multi Layer Ceramic Actuator) to Si-wafer using evaporated Pyrex #7740 glass thin-films for MEMS applications. Pyrex #7740 glass thin-films with same properties were deposited on MLCA under optimum RF magneto conditions(Ar 100%, input power $1\;W/cm^2$). After annealing in $450^{\circ}C$ for 1 hr, the anodic bonding of MLCA and Si-wafer was successfully performed at 600 V, $400^{\circ}C$ in - 760 mmHg. Then, the MLCA/Si bonded interface and fabricated Si diaphragm deflection characteristics were analyzed through the actuation test. It is possible to control with accurate deflection of Si diaphragm according to its geometries and its maximum non-linearity is 0.05-0.08 %FS. Moreover, any damages or separation of MLCA/Si bonded interfaces do not occur during actuation test. Therefore, it is expected that anodic bonding technology of MLCA/Si wafers could be usefully applied for the fabrication process of high-performance piezoelectric MEMS devices.

A Study on Tribology Characteristics of Laser Patterned DLC Thin Films (Laser patterning된 DLC 박막의 Tribology 특성연구)

  • Lee, Ji Seok;Kim, Dong Jun;Shin, Dong Chul;Kim, Tae Gyu
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.33 no.1
    • /
    • pp.25-32
    • /
    • 2020
  • In this study, the tribology of laser patterned DLC thin film was studied. DLC thin films were coated by RF-PECVD to improve the durability of tungsten carbide (WC) materials. DLC thin films have high hardness and low friction characteristics. Dot and line patterning was processed on the surface of DLC thin film with femtosecond laser, and the coefficient of friction was improved. As a result of ball on disk abrasion test, the hardness and friction coefficient of DLC thin films were much better than that of WC material. The friction coefficient of DLC thin film with dot patterning and line patterning showed better results. The excellent performance of the laser patterned DLC coating is appeared to reduce the coefficient of friction due to the reduction of surface contact area.

Linear Tapered Slot Rectifying Antenna for Portable UHF-Band RFID System (휴대용 UHF대역 RFID 시스템을 위한 선형 테이퍼드 슬롯 정류 안테나)

  • Pyo, Seongmin
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.368-371
    • /
    • 2020
  • In this paper, we propose a linear tapered slot rectifying antenna for a portable UHF-band RFID system. Since the proposed rectifying antenna does not use a dielectric substrate, the planar antenna is implemented with a thin metal thickness. The rectifier circuit converts input RF power into output DC voltage using a voltage doubler circuit based on two anti-parallel schottky diodes. The rectifying antenna is integrated by the voltage doubler circuit into a linear tapered slot antenna. For conjugate impedance matching of the rectifying circuit and the linear tapered slot antenna, the source-pull method was utilized by adjusting the angle of the tapered slot and the length of the antenna feed line. The proposed antenna prototype has been verified with the electrical and radiation characteristics through RF-DC conversion and far-field radiation test in open space measurement environment. Finally, the proposed antenna is realized to 0.23-wavelength (75 mm) and 0.18-wavelength (60 mm) at 915 MHz center frequency.

Development and Performance Test of TWTA Maintenance System for the Low Altitude Surveillance Radar (저고도 탐지레이더용 진행파관증폭기 정비시스템 개발 및 성능시험 연구)

  • Yoon, In-Chul;Yun, Seok-Jin;Kwon, Jong-Won;Kim, Hie-Sik
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.47 no.6
    • /
    • pp.43-50
    • /
    • 2010
  • In this paper, the TWTA (Traveling Wave Tube Amplifier) maintenance system for the low altitude surveillance Radar was developed using the embedded Linux system, and its superiority was demonstrated through the performance test. Nowadays, the necessity of maintenance system and reliability testing on military equipments has been increasing steadily. In addition, nonlinear characteristics of the maintenance system for the low altitude surveillance Radar are more likely to have serious problems as well as to slow down durability. Therefore, after analyzing characteristics of RF input-output signal and TWTA, we designed interface circuits between the TWTA equipment and the embedded Linux system. The Linux kernel on the system was optimized to improve the efficiency and reliability. And our new TWTA maintenance system was evaluated in the real field. As a result, the proposed system was contented with desired specifications, and demonstrated military's fighting capabilities. Therefore, our novel system will advance military maintenance technology and will help to develop similar equipments.

Clinical Utility of the MMPI-A-RF's Internalization and Externalization Higher-Order Scales: Comparison With the K-CBCL's Internalization and Externalization Scales (MMPI-A-RF의 내재화 및 외현화 상위 척도의 임상적 유용성: K-CBCL의 내재화 및 외현화 척도와의 비교)

  • Eun-Bin, Shin;Eun-Hee, Park;Hyun-Joo, Hong
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.30 no.2
    • /
    • pp.119-126
    • /
    • 2022
  • Objectives : The purpose of this study was to examine the clinical utility of the internalization and externalization higher-order scales of the Minnesota Multiphasic Personality Inventory-Adolescent Restructured Form (MMPI-A-RF), compared with those scales of the Korean Child Behavior Checklist (K-CBCL). Methods : 43 adolescents with internalizing disorders and 44 adolescents with externalizing disorders and their parents were administered the MMPI-A-RF and K-CBCL each. To verify the difference between the internalization and externalization scales of the MMPI-A-RF and K-CBCL for each group, independent-sample t test was performed. To compare the agreement between the MMPI-A-RF and K-CBCL, correlation analysis was also conducted. Lastly, to identify which scales significantly best predict each of the internalizing and externalizing disorder, logistic regression analysis was conducted. Results : Internalization scales of the MMPI-A-RF and K-CBCL were significantly higher in the internalizing disorder group, and the externalization scales were significantly higher in the externalizing disorder group. The positive correlation was significant only for internalization problems between the two evaluation measures in both groups (each r=0.360, p<0.05, r=0.572, p<0.05). In addition, the scales significantly predicted internalizing and externalizing disorders were the internalization and externalization scales of the MMPI-A-RF, followed by the externalization scale of the K-CBCL (R2=0.407, p<0.05). Conclusions : The internalization and externalization higher-order scales of the MMPI-A-RF were found to reliably reflect the characteristics of each disorder in adolescents and be useful evaluative scales to differentiate disorders. Moreover, if adolescents show externalization problems, additional information from the K-CBCL can be more useful to differentiate disorders.

Modeling of O/E conversion for 40 Gbps WGPD submodule (40Gbps 급 도파로형 광수신소자 submodule의 광전변환특성 모델링)

  • Jeon, Su-Chang;Yun, Il-Gu
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.79-80
    • /
    • 2005
  • In this paper, the circuit models of optical to electrical(O/E) characteristics of waveguide photodiode(WGPD) submodule are examined. Test structures of WGPD and WGPD submodule were fabricated and S21 parameter was measured to characterize the O/E conversion property. Valid circuit models were derived by RF circuit simulation and O/E characteristics were modeled to analyze the effects of model parameters on the WGPD submodule performances. Based on the results, it can be concluded that the suggested WGPD submodule model can explain the characteristics of the O/E conversion of WGPD submodule, where the parasitic components originated from ribbon bonding block crucially influence on the performance of WGPD submodule, are able to show more efficient property by making compact bonding structure. We propose an effective WGPD submodule bonding structure and it can ensure the 40Gbps operation of WGPD.

  • PDF

Ablation Characteristics of Bovine Liver According to Cool-Tip Temperature of RFA Equipment (고주파 열치료 장비의 Cool-Tip 온도에 따른 소간의 소작 특성)

  • Choi, Young-Jae;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.155-161
    • /
    • 2015
  • This study confirmed the correlation between the change of the cooling water in internal cooling system and the size of the ablation site of bovine liver in RF heat treatment equipment. The bovine liver was resection with $4{\times}4{\times}4cm^3$ in 2cm cool-tip and with $6{\times}6{\times}6cm^3$ in 3cm cool-tip for the experiments. Area and perimeter of the ablation site for bovine liver were measured by Freehand techniques of MRI. It showed area and perimeter decreased during cool-tip temperature rises 6 and 12 minutes ablation using a 2cm and 3cm cool-tip. The correlation of cool-tip temperature and area and perimeter was statistically significant the result are shown(p=.000). The measurements of area and perimeter were more accurate with MRI in actual measurements and MRI for ablation range. The statistical results using Paired sample T-test was also significant(p=.038). The ablation range of bovine liver decreased according as cooling water temperature increases in RF heat treatment equipment for reason of carbonization occurred due to does not accurately pass the RF energy. Therefore, it is considered the effect of RF heat treatment would be increased if the temperature of the cooling water consistently maintain the low temperature in order to reduce the generation of carbide at RF heat treatment and RF energy is delivered accurately.