• Title/Summary/Keyword: RECORDED DATA

Search Result 3,260, Processing Time 0.034 seconds

Effect of Feeding Different Maturity Leaves and Intermixing of the Leaves on Commercial Characters of Bivoltine Hybrid Silkworm (Bombyx mori L.)

  • Rahmathulla, V.K.;Raj, Tilak;Himanthraj, M.T.;Vindya, G.S.;Devi, R.G.Geetha
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.6 no.1
    • /
    • pp.15-19
    • /
    • 2003
  • The study evaluated the influence of feeding different maturity leaves i.e., tender, medium, coarse and mixed leaves of three different maturity during late larval stages of new bivoltine race $(CSR_{3} {\times} CSR_{6})$. The data were compared with shoot feeding and control batches in which conventional feeding method was followed. The most of the larval and cocoon characters were recorded significantly higher in tender leaves fed batches followed by T4 batch (2 times tender and 1 time coarse leaves). Lowest melting percentage (1.494%) was recorded in T4 and highest (4.69%) was recorded in coarse leaf (T3) fed batches. Significantly higher post cocoon parameters viz., average filament length, non-breakable filament length, renditta and raw silk percentage were recorded in tender loaves fed batches.

Electromyographic Analysis of Muscle Activity and Fatigue of the Paraspinal Muscles During a Repetitive Lifting Task (반복 들기 작업에 따른 허리주변 근육의 근활성도와 근피로도에 대한 근전도 분석)

  • Kim, Won-Ho
    • Physical Therapy Korea
    • /
    • v.16 no.3
    • /
    • pp.16-23
    • /
    • 2009
  • The purpose of this study was to investigate the effects of a repetitive lifting task on the level of activation and median frequency of the paraspinal muscles, and to provide basic data of the maximal acceptable duration of the lifting task to avoid muscle fatigue. Ten healthy male subjects were recruited as participants and they repetitively (12 lifts/min) lifted a box ($46cm{\times}30cm{\times}30cm$, 15 kg) for 10 minutes. Electromyographic data (muscle activation and median frequency), heart rate, and Borg CR10 score were recorded at 1, 3, 5, 7, and 9 minutes after the lifting task. Electromyographic data was recorded from the elector spinalis, mutifidus, external oblique abdominis, and rectus abdominis for 1 minute. The results showed that as the repetitive lifting task progressed, the heart rate and Borg CR10 score significantly increased. In addition, activation of the muscles increased. The median frequency significantly decreased over time in the elector spinalis, mutifidus, and external oblique abdominis (right side), except for the external oblique abdominis (left side) and rectus abdominis. It is suggested that the median frequency recorded from a dynamic task is used to monitor muscle fatigue. Furthermore, the repetitive lifting task (15 kg, 12 lifts/min) should not continue for more than 3 minutes in order to avoid muscle fatigue.

  • PDF

Study on the applicability of the principal component analysis for detecting leaks in water pipe networks (상수관망의 누수감지를 위한 주성분 분석의 적용 가능성에 대한 연구)

  • Kim, Kimin;Park, Suwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.2
    • /
    • pp.159-167
    • /
    • 2019
  • In this paper the potential of the principal component analysis(PCA) technique for the application of detecting leaks in water pipe networks was evaluated. For this purpose the PCA was conducted to evaluate the relevance of the calculated outliers of a PCA model utilizing the recorded pipe flows and the recorded pipe leak incidents of a case study water distribution system. The PCA technique was enhanced by applying the computational algorithms developed in this study which were designed to extract a partial set of flow data from the original 24 hour flow data so that the effective outlier detection rate was maximized. The relevance of the calculated outliers of a PCA model and the recorded pipe leak incidents was analyzed. The developed algorithm may be applied in determining further leak detection field work for water distribution blocks that have more than 70% of the effective outlier detection rate. However, the analysis suggested that further development on the algorithm is needed to enhance the applicability of the PCA in detecting leaks by considering series of leak reports happening in a relatively short period.

Application of OMA on the bench-scale earthquake simulator using micro tremor data

  • Kasimzade, Azer A.;Tuhta, Sertac
    • Structural Engineering and Mechanics
    • /
    • v.61 no.2
    • /
    • pp.267-274
    • /
    • 2017
  • In this study was investigated of possibility using the recorded micro tremor data on ground level as ambient vibration input excitation data for investigation and application Operational Modal Analysis (OMA) on the bench-scale earthquake simulator (The Quanser Shake Table) for model steel structures. As known OMA methods (such as EFDD, SSI and so on) are supposed to deal with the ambient responses. For this purpose, analytical and experimental modal analysis of a model steel structure for dynamic characteristics was evaluated. 3D Finite element model of the building was evaluated for the model steel structure based on the design drawing. Ambient excitation was provided by shake table from the recorded micro tremor ambient vibration data on ground level. Enhanced Frequency Domain Decomposition is used for the output only modal identification. From this study, best correlation is found between mode shapes. Natural frequencies and analytical frequencies in average (only) 2.8% are differences.

DRYING CHARACTERISTINCS OF THIN-LAYERS OF WHEAT AND BARLEY AT NEAR-AMBIENT TEMPERATURE

  • Sun, Da-Wen;J.J.Woods
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.896-905
    • /
    • 1993
  • Thin-layers of wheat and barley are dried at near-ambient temperatures(3.5$^{\circ}C$ -5$0^{\circ}C$) in order to obtain the intrinsic drying data. The well established apparatus was modified to enable it to record all the sample weight data in still air by using a purpose -built automatically controlled sliding valve. The air could be diverted in less than 0.5seconds and a 7 second period was required to attain a steady weight reading. With this apparatus, very smooth drying curves were obtained. The data of sample weight , drying temperature and dew point temperature wee recorded continuously . The drying process was terminated when the moisture content change in 24 hours was less than 0.004 d.b. This was achieved by drying a sample for about a week . The final points were recorded as the dynamic equilibrium moisture content(EMC). The drying data were than fitted to the exponential Newton model and the dynamic EMC data were fitted to the Modified-Chung-Pfost Model . All the fitted parameters are given and comparison is made with previous published data. The comparisons who that the current drying constants are lower than the previous data, the dynamic EMC data obtained for wheat and barely agree with the previous data. The results show that to obtain the drying constant in the exponential Newton model, adequate drying time is necessary.

  • PDF

Characteristics of Trigeminal Evoked Potential and It's Pathway in the Rat (백서에서 삼차신경 유발전위의 특성과 경로 분석)

  • Kim, Se-Hyuk;Zhao, Chun-Zhi;Kwon, Oh-Kyoo;Lee, Bae-Hwan;Park, Yong-Gou;Chung, Sang-Sup
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.8
    • /
    • pp.985-994
    • /
    • 2000
  • Objective : There are some advantages of trigeminal evoked potential(TEP) recording compared to other somatosensory evoked potential(SSEP) recordings. The trigeminal sensory pathway has a pure sensory nerve branch, a broader receptive field in cerebral cortex, and a shorter pathway. Despite these advantages, there is little agreement as to what constitutes a normal response and what wave forms truly characterize the intraoperative TEP. This study presents the normative data of TEP recorded on the epidural surface of the rat with a platinum ball electrode. Materials & Methods : Under general anesthesia with urethane, the adult Sprague-Dawley male rats(300-350g) were given electrical stimulation with two stainless steel electrodes which were inserted into the subcutaneous layer of the area around whiskers. A reference electrode was positioned in the temporalis muscle ipsilateral to the recording site. Results : TEPs were recorded in the Par I area of somatosensory cortex and recorded most apparently on the point of 2mm posterior from the bregma and 6mm lateral from the midline. The typical wave form consisted of 5 peaks (N1-P1-N2-P2-N3 according to emerging order, upward negativity). Each latency to corresponding peaks was not influenced by the different intensities of stimulation, especially from 1 to 5mA. Average latencies of 5 peaks were in the following order ; 7.7, 11.1, 15, 22.3, 29.4ms. There was also no significant difference between latencies before and after administration of muscle relaxant(pancuronium). For the electrophysiological localization of recorded waves, the action potential of a single unit was recorded with glass microelectrode(filled with 2M NaCl, $3-5M{\Omega}$) in the thalamus of rat. A sharp wave was recorded in the VPM nucleus, in which the latency was shorter than that of N1. This suggests that all 5 peaks were generated by neural activities in the suprathalamic pathway. Conclusion : In terms of recording near-field potentials, our data also suggests that TEP in the rat may be superior to other SSEPs. In overall, these results may afford normative data for the studies of supratentorial lesions such as hydrocephalus or cerebral ischemia which can have an influence on near-field potentials.

  • PDF

Saccadic Movement as a Performance Measure of Vigilance Task (경계작업 척도로서의 안구운동 특성)

  • Lee, Myeon-U;Lee, Gwan-Haeng;Jo, Yeong-Jin
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.8 no.1
    • /
    • pp.13-21
    • /
    • 1982
  • Experiments on the eye movement behavior were performed using Vidicon Eye Camera. Factorial design ( $3{\times}3$) was used to evaluate the validity of the eye movement as a performance measure in vigilance task. Eye movement data were recorded in video tapes, then the data were converted to digital signals, which were reduced to quantitative fixation and saccadic movement data by a microcomputer. To compare with existing vigilance performance measures, response time and the number of false alarms were also recorded. The results showed that the saccadic movement is a good measure of the performance in vigilance task : 1. Both the response time and the saccadic movement increased significantly during the initial two time blocks. 2. High correlations were shown between the response time and the saccadic movement. 3. The locational uncertainty affects the saccadic movement, the number of fixations, the response time but doesn't affect the duration of eye fixations.

  • PDF

Enhanced least square complex frequency method for operational modal analysis of noisy data

  • Akrami, V.;Zamani, S. Majid
    • Earthquakes and Structures
    • /
    • v.15 no.3
    • /
    • pp.263-273
    • /
    • 2018
  • Operational modal analysis is being widely used in aerospace, mechanical and civil engineering. Common research fields include optimal design and rehabilitation under dynamic loads, structural health monitoring, modification and control of dynamic response and analytical model updating. In many practical cases, influence of noise contamination in the recorded data makes it difficult to identify the modal parameters accurately. In this paper, an improved frequency domain method called Enhanced Least Square Complex Frequency (eLSCF) is developed to extract modal parameters from noisy recorded data. The proposed method makes the use of pre-defined approximate mode shape vectors to refine the cross-power spectral density matrix and extract fundamental frequency for the mode of interest. The efficiency of the proposed method is illustrated using an example five story shear frame loaded by random excitation and different noise signals.

A Study of Cheju Power System Characteristics at the Large Disturbance (대형 계통동요시의 제주계통 특성 해석)

  • Choi, H.K.;Moon, Y.H.;Yoon, J.Y.;Kim, D.J.;Choo, J.B.;Yun, Y.B.;Kim, Y.H.;Jin, W.L.
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.29-32
    • /
    • 2000
  • This paper presents the analysis of Cheju power system characteristics by performing modeling/simulation in order to match the field recorded data. The comparisons between simulation results and recorded data does not show good match due to the incorrect supposed data, but it is believed that this study is enough to simulate the Cheiu power system characteristics.

  • PDF

Effect of dynamic range consumption for microholographic data storage system (마이크로 홀로그래픽 시스템에서 미디어의 소진효과)

  • Kim, Do-Hyung;Min, Cheol-Ki;Cho, Jang-Hyun;Kim, Nak-Yeong;Park, Kyoung-Su;Park, No-Cheol;Yang, Hyun-Seok;Park, Young-Pil
    • Transactions of the Society of Information Storage Systems
    • /
    • v.7 no.1
    • /
    • pp.31-35
    • /
    • 2011
  • In microholographic data storage system (MDSS), compact recording is required to achieve high capacity.[1] When the data is recorded, neighbor monomer is also affected by reaction at the focal point.[2,3] This unintended process caused more monomer consumption and degradation of total capacity. To avoid this extra consumption of dynamic range, it is required to define the effective dynamic range for MDSS. In this paper, we experimentally investigate the relation between dynamic range consumption and micro grating formation. Dynamic range consumption was monitored by real time read-out system. Micrograting was recorded with different consumption ratio and compared by diffraction efficiency of track direction. Finally, we define suitable dynamic range for MDSS.