• Title/Summary/Keyword: RCA cleaning

Search Result 27, Processing Time 0.033 seconds

A new cleaning concept for display process with electrolyzed anode water (전해 양극수를 이용한 디스플레이 신 세정 공정)

  • Choi Minki;Cha Jiyung;Kim Younggeun;Ryoo Kunkul
    • Proceedings of the KAIS Fall Conference
    • /
    • 2004.11a
    • /
    • pp.99-102
    • /
    • 2004
  • Display process has adopted RCA clean, being applied to large area and coped with environmental issue for last ten years. However, the approaching concept of ozonized, hydrogenised, or electrolyzed water cleaning technologies is within RCA clean paradigm. In this work, only electrolyzed anode water was applied to clean particles and organics as well as metals based on Pourbaix concept, and as a test vehicle, MgO particles were introduced to prove the new concept. The electrolyzed anode water is very oxidative with high oxidation reduction potential(ORP) and low in pH of more than 900mV and 3.1, respectively. MgO particles were immerged in the anode water and its weight losses due to dissolution were measured with time. Weight losses were in the ranges of 100 to 500 micrograms in 250m1 anode waters depending on their ORP and pH. Therefore it was concluded that the cleaning radicals in the anode water was at least in the range of 1 to 5E20 ea per 250 ml anode water equivalent to IE18 ea/cm3. Hence it can be assumed that the anode water be applied to display cleaning since 1E10 to IE15 ea/cm3 ranges of contaminants are being treated. In addition, it was observed that anode water does not develop micro-roughness on hydrophobic surface while it does on the native silicon oxide.

  • PDF

A Study on the Characteristics of Silicon Direct Bonding by Hydrogen Plasma Treatment (수소 플라즈마 처리에 의한 실리콘 직접접합 특성에 관한 연구)

  • Choe, U-Beom;Ju, Cheol-Min;Kim, Dong-Nam;Seong, Man-Yeong
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.7
    • /
    • pp.424-432
    • /
    • 2000
  • The plasma surface treatment, using hydrogen gas, of the silicon wafer was investigated as a pretreatment for the application to silicon-on-insulator (SOI) wafers using the silicon direct bonding technique. The chemical reactions of hydrogen plasma with surfaces were used for both the surface activation and the removal of surface contaminants. As a result of exposure of silicon wafer to the plasma, an active oxide layer was formed on the surface, which was rendered hydrophilic. The surface roughness and morphology were estimated as functions of plasma exposing time as well as of power. The surface became smoother with decreased incident hydrogen ion flux by reducing plasma exposing time and power. This process was very effective to reduce the carbon contaminants on the silicon surface, which was responsible for a high initial surface energy. The initial surface energy measured by the crack propagation method was 506 mJ/m2, which was up to about three times higher than that of a conventional RCA cleaning method.

  • PDF

Analysis of Wafer Cleaning Solution Characteristics and Metal Dissolution Behavior according to the Addition of Chelating Agent (착화제 첨가에 따른 웨이퍼 세정 용액 특성 분석 및 금속 용해 거동)

  • Kim, Myungsuk;Ryu, Keunhyuk;Lee, Kun-Jae
    • Journal of Powder Materials
    • /
    • v.28 no.1
    • /
    • pp.25-30
    • /
    • 2021
  • The surface of silicon dummy wafers is contaminated with metallic impurities owing to the reaction with and adhesion of chemicals during the oxidation process. These metallic impurities negatively affect the device performance, reliability, and yield. To solve this problem, a wafer-cleaning process that removes metallic impurities is essential. RCA (Radio Corporation of America) cleaning is commonly used, but there are problems such as increased surface roughness and formation of metal hydroxides. Herein, we attempt to use a chelating agent (EDTA) to reduce the surface roughness, improve the stability of cleaning solutions, and prevent the re-adsorption of impurities. The bonding between the cleaning solution and metal powder is analyzed by referring to the Pourbaix diagram. The changes in the ionic conductivity, H2O2 decomposition behavior, and degree of dissolution are checked with a conductivity meter, and the changes in the absorbance and particle size before and after the reaction are confirmed by ultraviolet-visible spectroscopy (UV-vis) and dynamic light scattering (DLS) analyses. Thus, the addition of a chelating agent prevents the decomposition of H2O2 and improves the life of the silicon wafer cleaning solution, allowing it to react smoothly with metallic impurities.

A Study on Silicon Wafer Surfaces Treated with Electrolyzed Water (전리수를 이용한 Si 웨이퍼 표면 변화 연구)

  • 김우혁;류근걸
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.3 no.2
    • /
    • pp.74-79
    • /
    • 2002
  • In the a rapid changes of the semiconductor manufacturing technologies for early 21st century, it may be safely said that a kernel of terms is the size increase of Si wafer and the size decrease of semiconductor devices. As the size of Si wafers increases and semiconductor device is miniaturized, the units of cleaning processes increases. A present cleaning technology is based upon RCA cleaning which consumes vast chemicals and ultra pure water (UPW) and is the high temperature process. Therefore, this technology gives rise to the environmental issue. To resolve this matter, candidates of advanced cleaning processes has been studied. One of them is to apply the electrolyzed water. In this work, Compared with surface on Si wafer with electrolyzed water cleaning and various chemicals cleaning, and analyzed Si wafer surface condition treated with elecoolyzed water by cleaning temperature and cleaning time. Especially. concentrate upon the contact angle. finally, contact angle on surface treated with cathode water cleaning is 17.28, and anode water cleaning is 34.1.

  • PDF

The Effect of Hydrogen Plasma on Surface Roughness and Activation in SOI Wafer Fabrication

  • Park, Woo-Beom;Kang, Ho-Cheol;Sung, Man-Young
    • Transactions on Electrical and Electronic Materials
    • /
    • v.1 no.1
    • /
    • pp.6-11
    • /
    • 2000
  • The hydrogen plasma treatment of silicon wafers in the reactive ion-etching mode was studied for the application to silicon-on-insulator wafers which were prepared using the wafer bonding technique. The chemical reactions of hydrogen plasma with surface were used for both surface activation and removal of surface contaminants. As a result of exposure of silicon wafers to the plasma, an active oxide layer was found on the surface. This layer was rendered hydrophilic. The surface roughness and morphology were examined as functions of the plasma exposing time and power. In addition, the surface became smoother with the shorter plasma exposing time and power. The value of initial surface energy estimated by the crack propagation method was 506 mJ/㎡, which was up to about three times higher as compared to the case of conventional direct using the wet RCA cleaning method.

  • PDF

A Study on the Characteristics of the High Concentration Ozone Generator for the Semiconductor Wafer Cleaning with the Ozone Dissolved De-ionized Water (반도체 웨이퍼의 오존 수(水) 세정을 위한 고농도 오존발생장치 특성 연구)

  • 손영수;함상용;문세호
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.12
    • /
    • pp.579-585
    • /
    • 2003
  • Recently the utilization of the ozone dissolved de-ionized water(DI-O3 water) in semiconductor wet cleaning process to replace the conventional RCA methods has been studied. In this paper, we propose the water-electrode type ozone generator which has the ozone gas characteristics of the high concentration and high purity to produce the high concentration DI-O3 water for the silicon wafer surface cleaning process. The ozone generator has the dual dielectric tube structure of silent discharge type and the water is both used to electrode and cooling water. We investigate the performance of the proposed ozone generator which has the design goal of the concentration of 7[wt%] and ozone generation quantity of 6[g/hr] at flow rate of 1[$\ell$/min). The experiment results show that the water electrode type ozone generator has the characteristics of 8.48[wt%] of concentration, 8.08[g/hr] of generation quantity and 76.2[g/kWh] of yield and it's possible to use the proposed ozone generator for the DI-O3 water cleaning process of silicon wafer surface.

A study on the electrical properties by the effect of wafer cleaning of OXYNITRIDE films deposited by Laser CVD (레이저 CVD법에 의해 퇴적된 OXYNITRIDE막의 기판세정법에 따른 특성에 관한 연구)

  • Kim, C.D.;Lee, S.K.;Kim, T.H.;Sung, Y.K.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1280-1282
    • /
    • 1997
  • The oxynitride films were photo-chemically deposited by ArF(wave length: 193nm) excimer laser CVD used to excite and dissociate gas phases $Si_2H_6$, $N_2O$, and $NH_3$ molecules. We obtained various electrical properties when we varied wafer cleaning procedures consisted of a conventional RCA and a two-dip step[4]. The results show the films have low leakage currents and good TZDB properties. We also analyzed the composition of the oxynitride films which have homogeneous composition throughout the film.

  • PDF

Reliable Measurement Methodology of Wafer Bonding Strength in 3D Integration Process Using Atomic Force Microscopy (삼차원집적공정에서 원자현미경을 활용한 Wafer Bonding Strength 측정 방법의 신뢰성에 관한 연구)

  • Choi, Eunmi;Pyo, Sung Gyu
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.20 no.2
    • /
    • pp.11-15
    • /
    • 2013
  • The wafer bonding process becomes a flexible approach to material and device integration. The bonding strength in 3-dimensional process is crucial factor in various interface bonding process such as silicon to silicon, silicon to metals such as oxides to adhesive intermediates. A measurement method of bonding strength was proposed by utilizing AFM applied CNT probe tip which indicated the relative simplicity in preparation of sample and to have merit capable to measure regardless type of films. Also, New Tool was utilized to measure of tip radius. The cleaned $SiO_2$-Si bonding strength of SPFM indicated 0.089 $J/m^2$, and the cleaning result by RCA 1($NH_4OH:H_2O:H_2O_2$) measured 0.044 $J/m^2$, indicated negligible tolerance which verified the possibility capable to measure accurate bonding strength. And it could be confirmed the effective bonding is possible through SPFM cleaning.

Characteristics of a-Si:H/c-Si interface and heterojunction solar cells depending on silicon wafer wet chemical cleaning (실리콘 기판 습식 세정에 따른 a-Si:H/c-Si 계면 및 이종접합 태양전지 특성 분석)

  • Song, Jun-Yong;Jeong, Dae-Young;Kim, Chan-Seok;Park, Sang-Hyun;Cho, Jun-Sik;Yun, Kyoung-Hun;Song, Jin-Soo;Lee, Jun-Sin;Kim, Dong-Hwan;Lee, Jeong-Chul
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.168-168
    • /
    • 2009
  • 고효율 실리콘 이종접합 태양전지 제작을 위한 요소기술 중 a-Si:H/c-Si 간의 계면 안정화는 태양전지 효율에 중요한 역할을 한다. 본 연구에서는 n-type 결정질 실리콘 기판을 사용하여, 소수전하들의 재결합을 방지하고, 계면 안정화를 실행하는 방안으로 실리콘 기판 습식 세정을 수행하였다. 반도체 공정에서 일반적으로 알려진 RCA 세정기법에 HF 세정을 마지막공정으로 추가하여 자연 산화막과 기타 불순물을 더욱 효과적으로 제거할 수 있도록 실험을 진행하였다. 마지막 공정으로 추가된 HF 세정에 의한 a-Si:H/c-Si 계면 안정화 효과를 관찰하기 위하여 HF농도와 HF 세정시간에 따른 소수반송자 수명을 측정하였다. 또한 HF 세정 이후 공정의 영향을 확인하기 위하여 PE-CVD법으로 a-Si:H 박막 증착 이전 실리콘 기판의 온도와 상온에서 머무는 시간에 따른 a-Si:H/c-Si 계면안정화 특성을 분석하였다. 본 실험을 통해 HF세정공정이 계면특성에 미치는 영향을 확인하였으며 실리콘 기판 습식 세정이 이종접합태양전지 특성에 미치는 영향을 분석하였다.

  • PDF