• Title/Summary/Keyword: RC건축물

Search Result 92, Processing Time 0.023 seconds

Evaluation of the Seismic Performance of Existing Building Structures (기존 철근콘크리트 건축물의 내진성능 평가)

  • 우운택
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.10a
    • /
    • pp.239-244
    • /
    • 2000
  • The necessity of the seismic performance evaluation of existing building structures is raised through the Taiwan earthquake in 1999. In this study, the methods of seismic performance evaluation of existing building structures in U.S.A. and Japan were reviewed, applied them to the three-story office building structures in Seoul. It is found out that it is possible to establish the seismic performance evaluation index of RC structure which meet Korean seismic code. Also it is concluded that if sufficient experimental and analytical data could be obtained, a reliable index for the evaluation of seismic performance of existing structures should be established in Korea.

  • PDF

Characteristics of Vertical Vibration Transfer according to RC Structure Systems (RC조 건축물의 구조시스템에 따른 수직진동 전달 특성 비교)

  • Chun, Ho-Min
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.196-201
    • /
    • 2006
  • In general, the vertical vibration problems for strength of members and serviceability of building structures are not considered in structural design process, but the prediction of the vertical vibration is very important and essential to structural design process. This study aims to investigate the characteristics of vertical vibration in terms of the transfer of horizontal directions on the rahmen building structures and the shear wall building structures. In order to examine the characteristics of vertical vibration, the modal test and the heel-drop excitation experiments were conducted several times on the two type building structures. The results from the experiments are analyzed and compared with the results. The results of this study suggest that the characteristics of vortical vibration transfer in horizontal way are effected from the fundamental frequency of the slabs and excitation forces and are effected the shear wall on the path of the vibration transfer.

  • PDF

A Study On Economic Evaluation of Permancet Form For Reinforced Concrete Building (RC 건축물에 적용한 비탈형 영구거푸집의 경제성 평가에 관한 연구)

  • 김형남;김우재;김성식;이복만;정상진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.475-480
    • /
    • 1999
  • Recently domestic building market in the face of 3D, in addition to construction cost increase, materials lack problems and opening a building market to foreign countries, is trying to find out the efficient ways of overcoming these problems. So the necessity to study the permanent form is urgent to escape the problems of constructing human power economy, cost down, noises problem, environmental prevention and efficacy of form work to technical improvement will contribute a practical permanent form in field through economic evaluation of permanent form. In this paper, we compared wood form cost with permanent form cost(made form polymer or fly ash) for frame work

  • PDF

RC 건물의 구조균열 발생원인 분석

  • 남윤오;이영섭;손기상
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2001.11a
    • /
    • pp.191-196
    • /
    • 2001
  • 국내 경제성장이 증대함에 따라 철근콘크리트 건축구조물은 다양화, 복잡화, 고층화 되고 있으며 이로 인한 사업의 무리한 추진으로 부실시공 등으로 국내에서는 1970년 4월 서울마포의 와우아파트 붕괴사고, 1995년 6월 삼풍붕괴 사고 등 크고 작은 사건 및 사고로 인한 막대한 재산과 고귀한 생명의 손실 등이 사회적인 문제로 대두되면서 건축물의 유지관리 및 안전진단 등에 대한 중요성이 부각되기 시작했다. 이렇게 크고 작은 사고들이 많이 발생함에 따라 기술인 들이 피땀 흘려 건설된 공공시설을 불신하게 되면서 건설공사중인 현장과 사용중인 시설물에 대해서 법으로 규제사항을 강화하거나 새로운 내용이 신설되고 있는 실정이며 전국 중요 시설물에 대한 유지 관리 업의 중요성이 대두되고 있는 실정이다.(중략)

  • PDF

Evaluation of RC Building Structures Designed According to Eurocode 8 (Eurocode 8에 의해 설계도니 건축물의 평가)

  • 이한선
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.10a
    • /
    • pp.297-304
    • /
    • 1999
  • the devastating earthquake which occurred in Turkey on August 187, 1999, reminds again us the necessity of the preparedness for the earthquake hazard. the level of earthquake engineering in Koran is still low due to the short period of the research and development in this field. Therefore the most efficient way of promoting our technology in this field is considered to collect the information on the state of the art and practice developed in the advanced countries in earthquake engineering and to analyze the advantages and disadvantages and then reflect these to the new seismic codes. for this purpose this study reviews the concept and main characteristics of Eurocode 8 and the findings of many researches that have been performed for the improvement of EC8. Finally the seismic performance evaluation of the building structures designed according to EC8. and the relevant recommendations are summarized.

  • PDF

Column Shortening Analysis and Field Measurement of Haeundae I'Park (초고층 건축물의 기둥축소량 해석 및 현장계측 - 해운대 아이파크)

  • Chung, Kwang-Ryang;Lee, Dae-Yong;Song, Ho-Beom;Park, Kwang-Min
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05b
    • /
    • pp.67-70
    • /
    • 2011
  • The effect of column shortening is a major consideration in design and construction of tall buildings, especially in concrete and composite structural systems. To avoid unexpected demage in structural and nonstructural elements, differential shortening between vertical members resulting from differing stress levels, loading histories, volume-to-surface ratios and other factors in a high-rise building must be properly considered in the design process. This paper represents analyzed and measured shortening results of RC cores and columns at the 72 story Haeundae I'Park. It shows that WACS program based on ACI and PCA material model is effective for the prediction of column shortening.

  • PDF

Quantitative Damage Index of RC Columns with Non-seismic Details (비내진상세를 가지는 철근콘크리트 기둥의 정량적 손상도 평가 기준)

  • Kim, Kyung-Min;Oh, Sang-Hoon;Choi, Kwang-Yong;Lee, Jung-Han;Park, Byung-Cheol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.6
    • /
    • pp.11-20
    • /
    • 2013
  • In this paper, the quantitative damage index for reinforced concrete (RC) columns with non-seismic details were presented. They are necessary to carry out the postearthquake safety evaluation of RC buildings under 5 stories without seismic details. The static cyclic test of the RC frame sub-assemblage that was an one span and actual-sized was first conducted. The specimen collapsed by the shear failure after flexural yielding of a column, lots of cracks on the surfaces of columns and beam-column joints and the cover concrete splitting at the bottom of columns occurred. The damage levels of these kinds of columns with non-seismic details were classified to five based on the load-displacement relationship by the test result. The residual story drift ratios and crack widths were then adapted as the quantitative index to evaluate the damage limit states because those values were comparatively easy to measure right after earthquakes. The highest one among the residual story drift ratios under the similar maximum story drift ratio decided on the residual story drift ratio of each damage limit state. On the other hand, the lowest and average ones among the respective residual shear and flexural widths under the similar maximum story drift ratio decided on the residual shear and flexural widths of each damage limit state, respectively. These values for each damage limit state resulted in being smaller than those by the international damage evaluation guidelines that are for seismically designed members under the same deformations.

A study on the change of the Building appearances according to the change of conservation policies and urban fabric in Bukchon of Seoul, since 1980's (서울 북촌(北村)의 역사경관보전정책 변천에 따른 건축물 변화)

  • Song, In-Ho;Kim, Young-Soo
    • Journal of architectural history
    • /
    • v.15 no.3
    • /
    • pp.99-118
    • /
    • 2006
  • We have focused on the building appearance according to the change of conservation policy and urban fabric in Bukchon, Seoul. The Urban Hanok, urban traditional housing type, had been evolved in modern contort from 1920's to 1960's, that is to say, many buildings(Urban Hanok) in Bukchon area has built up with a lot and road at the same time. But the change of conservation policy has an effect on the urban fabric and building(wooden structure, RC and brick building). Thus many types of building in Bukchon has undergone a various change. The purpose of this paper is to define a change factor of Bukchon buildings. Thus we need to pay attention to policy and urban fabric. We reached the result as follows. First, the change of architecture regulations according to the several policies(an aesthetic area, an altitude area for sky line restriction and so on) brought into building deformation and eventually the historic scenery of Bukchon has been spoiled. Second, the change of policy had an effect on the change of roads and lots. Buildings on a widen road and a united lot was built newly. But new buildings built up with a concrete or brick structure was not in harmony with the historic scenery of Bukchon area. Third, a development method of a large lot with lack prudence(disregarded a scale and size of lot) did damage to Urban hanok and urban fabric. With the understanding on the relationship of buildings, a urban fabric and a policy in Bukchon, we can define the identity and correspond with the urgent request for a the conservation of historic urban scenery In addition we can suggest the policy and the design guidelines for the reservation and rehabilitation for Bukchon, Seoul.

  • PDF

Seismic Evaluation of Low-rise RC Building in korea (국내 저층구조물의 내진성능평가)

  • Park, Jin Hwa;Ahn, Tea Sang;Seo, Hyun Sik;Kim, Sang Dea
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.29-29
    • /
    • 2011
  • 국내에서 기존건축물의 내진성능평가 기법이 연구되기 시작한지 20여 년간 다양한 평가방법이 제안되었다. 그러나, 제안된 평가방법은 미국이나 일본의 평가 방법을 도입 및 수정하는 내용이 주가 되어 국내실정에 맞지 않는 부분도 많이 발견되었다. 따라서 국내에서 제안된 기존 건축물의 내진성능 평가기법, 지진피해예측에 근거한 보강건축물의 합리적인 선정방법 및 이들 건축물에 적합한 내진보강방법 등의 연구는 아직까지 초보적인 단계라고 할 수 있다. 이에 본 연구의 목적은 이러한 평가 기법을 적용한 국내 저층구조물의 내진성능을 평가하는 것이다. 저층구조물의 내진성능을 평가하기 위하여 1988년 내진설계가 도입되기 이전에 건립된 4층 규모의 학교구조물을 해석대상 구조물로 선정하였다. 대상 해석구조물의 내진성능평가는 일본의 내진성능 평가법을 참고하여 평가절차가 다소 복잡한 부분을 국내 실정에 맞게 개선시킨 내진화 우선도 평가방법과 정밀한 내진성능을 평하는 방법으로 세계적으로 널리 사용되고 있는 ATC-40 성능평가방법에서 등가단자유 모델로 변환 과정에서 등가유효감쇠 및 등가유효주기 산정 관계식의 문제점을 개선한 FEMA-440의 선형화 성능평가방법(Linearization Method)을 사용하여 구조물의 성능을 평가하였다. 내진 성능 평가를 위해 현재 전 세계적으로 널리 사용되고 있는 구조물 비선형 전용 해석 프로그램인 Perform-3D를 이용하여 해석을 수행하였다. 본 연구를 통해 기존 저층구조물로 선정한 학교구조물에 대한 내진성능을 평가한 결과, 내진화 우선도 평가법 및 FEMA-440의 내진성능 평가는 유사한 경향의 결과를 나타내었고, 두 평가결과를 요약하면 Y방향은 보와 기둥에 끼인 조적벽체의 영향으로 별도의 내진성능이 향상 보강이 필요없으나, X방향은 창문하부 허리 조적벽 등의 영향으로 다소 취성적인 내진성능을 보유하고 있어 충분한 내진성능 확보를 위한 추가적인 보강이 필요한 것으로 판단된다.

  • PDF

The Application of Post-tensioned Slab System to Tall Buildings (초고층 건축물의 포스트텐션 슬래브 시스템 적용)

  • Chung, Kwang-Ryang
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.879-882
    • /
    • 2008
  • The market of Korea of post-tension system for building is growing up since 2000 and many engineers and construction companies show interest in it. This paper introduces the structure system and construction of post-tension tall buildings including recent trend in the industry of post-tension system for buildings in Korea and the point to be considered when design post-tensioned tall building. Park Polis is composed of two towers of 39 stories with a level to the top of the roof +144m and is currently under construction at Ulsan in Korea. This building designed as the unbonded post-tension floor system and will be the tallest and first high-rise post-tensioned building in Korea. The structural system is composed of the flat slabs, perimeter columns and core walls. At first, this building had designed as regular RC flat slab with perimeter beams. However, floor structure system was reconsidered because the construction company wants to improve efficiency of construction. As a result, the floor system of PARK POLIS re-designed as PT flat slab.

  • PDF