• Title/Summary/Keyword: RBCs

Search Result 117, Processing Time 0.032 seconds

SUPEROXIDE DISMUTASE - AND CATALASE - ACTIVITY IN BLOOD PLASMA AND RED BLOOD CELLS IN PERIODONTITIS (치주염 환자의 혈장과 적혈구내 S.O.D와 Catalase 활성도에 관한 연구)

  • Hwang, Seung-Hwan;Kim, Byung-Ok;Han, Kyung-Yoon
    • Journal of Periodontal and Implant Science
    • /
    • v.25 no.1
    • /
    • pp.167-178
    • /
    • 1995
  • It has been believed that the increased release of free oxygen radicals and their tissue damaging potency might be a contributing factor in the pathogenesis of periodontal disease. Antioxidant enzymes such as superoxide dismutase(SOD) and catalase can protect the tissue damage from the free oxygen radicals($O_2^-,H_2O_2$, and $OH^-$). In order to investigate the SOD- and catalase - activity in the blood plasma and red blood cells(RBCs) of the patients with perodontitis, 19 male periodontitis patients($25{\sim}35$ years old) who had good general health, more than 10 teeth with severely inflamed gingiva, attachment loss more than 6mm and bone loss were selected as periodontitis group, and 13 male volunteers($22{\sim}29$ years old) with good general and periodontal health were selected as normal group. After blood plasma and RBC were separated from peripheral blood of 2ml collected from antecubital vein of each subject, SOD- activity in blood plasma and RBCs was measured by the same method that Paoletti et al. did, and catalase - activity in RBC was measured by the same method that Beers et al, did. The difference of SOD- and catalase - activity between the normal and the periodontitis groups was statistically analyzed by Student t-test with SPSS/PC program.The results were as follows : 1. SOD activity in blood plasma was significantly lower in the periodontitis group($1.986{\pm}0.893$) than in the normal group($3.324{\pm}1.044$)(p<0.05). 2. There was no statistical significance in the difference of SOD- activity in RBCs between the periodontitis group($7.753{\pm}3.206$) and the normal group($8.116{\pm}1.192$)(p$242.8{\pm}45.6$) than in the normal group($280.2{\pm}32.6$)(p

  • PDF

Comparison of WBCs and RBCs Concordance between the Cobas u 701 Analyzer and Three Manual Microscopy Methods in Urine Sediment (소변 침전물에서 Cobas u 701 Analyzer와 세 가지 수동 현미경검사법의 백혈구와 적혈구의 일치도 비교)

  • Hyeok-Jae LEE;Min-Hyeok LEE
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.55 no.2
    • /
    • pp.82-92
    • /
    • 2023
  • Urine sediments are performed by a microscopic examination of centrifuged urine by medical technologists. This study examined different urine sediment preparation procedures. The 107 fresh urine specimens that tested positive from white blood cells (WBCs) and red blood cells (RBCs) in the urine dipstick test and the cobas u 701 analyzer, respectively, were selected for manual microscopy. This study evaluated an automated urine sediment analyzer and three manual microscopy methods for WBCs and RBCs. The methods were performed according to the test guidelines. The coefficients of determination between the cobas u 701 analyzer and the Korean Association of Quality Assurance for Clinical Laboratory (KAQACL) for WBCs and RBCs were r2=0.977 and r2=0.970, respectively. The concordance rates between the cobas u 701 analyzer and KAQACL for WBCs and RBCs were 74.8% and 77.6%, respectively. A good correlation and concordance with the automatic analyzer were shown when the specimens were prepared and examined using the KAQACL method. Consequently, the differences in the urine sediment preparation procedures affected the sediment concentrations, influencing the cell number per high power field (HPF).

Interpertation of Doppler Indicies in Neurosonologic Examinations (신경초음파 검사에서 Doppler소견의 판독)

  • Kim, Jei
    • Annals of Clinical Neurophysiology
    • /
    • v.1 no.1
    • /
    • pp.47-54
    • /
    • 1999
  • The Doppler in neurosonologic examination could be applied to blood flow to determine its movement, the direction of its movement, and how fast it is. Indicies of the Doppler study denoted velocity, direction, and amount of RBC in the examined vessel. Systolic. diastolic, and mean blood flow velocities represent velocity of RBCs in a sample volume. Blood flow direction to the probe means direction of RBC to the probe. Size of amplitude displays toe amount of the RBCs passing the sample volume. Spectral broadening means presence of turbelence. The RBC movements and hemodynamics at the examined vessels can be estimated by analysis of Doppler indicies The formation and meaning of each of neurosonologic Doppler study is described in the present review.

  • PDF

Numerical Simulation of Blood Cell Motion in a Simple Shear Flow

  • Choi, Choeng-Ryul;Kim, Chang-Nyung;Hong, Tae-Hyub
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1487-1491
    • /
    • 2008
  • Detailed knowledge on the motion of blood cells flowing in micro-channels under simple shear flow and the influence of blood flow is essential to provide a better understanding on the blood rheological properties and blood cell aggregation. The microscopic behavior of red blood cell (RBCs) is numerically investigated using a fluid-structure interaction (FSI) method based on the Arbitrary-Lagrangian-Eulerian (ALE) approach and the dynamic mesh method (smoothing and remeshing) in FLUENT (ANSYS Inc., USA). The employed FSI method could be applied to the motions and deformations of a single blood cell and multiple blood cells, and the primary thrombogenesis caused by platelet aggregation. It is expected that, combined with a sophisticated large-scale computational technique, the simulation method will be useful for understanding the overall properties of blood flow from blood cellular level (microscopic) to the resulting rheological properties of blood as a mass (macroscopic).

  • PDF

Identification and Characterization of a Novel Cytosolic Phospholipase from Bovine Red Blood Cells (소 적혈구로부터 새로운 형태의 세포질 포스포리파제 의 동정 및 특성규명)

  • 신혜숙;김하동;장동훈;전형준;유충규
    • YAKHAK HOEJI
    • /
    • v.45 no.4
    • /
    • pp.407-412
    • /
    • 2001
  • A $Ca^{2+}$_dependent PLA$_2$activity termed rPLA$_2$, was detected in the cytosol of bovine red blood cells (RBCs). The rPLA$_2$was characterized as a similar form to Group IV cPLA$_2$, but different in several column chromatographic profiles including an anion exchange column. To examine whether this rPLA$_2$is different from the well characterized cPLA$_2$, a quinone derivative, BJ50, was developed and tested for the inhibitory effect on the two PLA$_2$enzymes. The rPLA$_2$activity was inhibited by a quinone derivative (BJ50) with ID$_{50}$ of 20 $\mu$M., but had no effect on the cPLA$_2$, suggesting that rPLA$_2$may be a novel type of cytosolic PLA$_2$in RBCs.s.s.

  • PDF

Difference in Methylmercury Exposure to Fetus and Breast-Feeding Offspring: a Mini-Review

  • Sakamoto, Mineshi;Machi, Kubota;Pan, Huan Sheng
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.06a
    • /
    • pp.73-83
    • /
    • 2005
  • Higher methylmercury (MeHg) accumulation and susceptibility to toxicity in the fetus than in the mother at parturition is well known. However, the difference in MeHg exposure to fetus and offspring throughout gestation and suckling is not well established. In the human, the effects of MeHg exposure on pregnant and breast-feeding women remain an important issue for elucidation, especially those of continuous uptake in high-fish-consumption populations. The purpose of this paper was to evaluate the difference in MeHg exposure to fetus and offspring throughout gestation and lactation using our recent animal and human studies data. In the animal study, adult female rats were given a diet containing 5 ${\mu}$g/g Hg (as MeHg) for 8 weeks. Then they were mated and subsequently given the same diet throughout gestation and suckling. On embryonic days 18, 20, 22 and at parturition, the concentrations of Hg in the brains of fetus were approximately 1.5-2.0 times higher than those in the mothers. However, during the suckling period Hg concentrations in the brain rapidly declined to about 1/10 of that during late pregnancy. Hg concentrations in blood also decreased rapidly after birth. In human study, Hg concentrations in red blood cells (RBCs-Hg) in 16 pairs of maternal and umbilical cord blood samples were compared at birth and 3 months of age after parturition. RBCs-Hg concentration in the umbilical cords was about 1.6 times higher than those in the mothers at parturition. However, all the infants showed declines in Hg concentrations throughout the breast-feeding period. The Hg concentration in RBCs-Hg at 3 months of age was about half that at birth. Both the animal and human studies indicated that MeHg exposure to the fetus might be especially high but it dramatically decreases during the suckling period. Therefore, close attention should be paid to the gestation rather than the breast-feeding period to avoid the risk of MeHg to human infants.

  • PDF

Potential Antioxidant Trace Mineral (Zn, Mn, Cu and Fe) Concentrations Measured by Biochemical Indices in South Koreans

  • Cho, Young-Eun;Byun, Young-Mee;Kwak, Eun-Hee;Yoon, Jin-Sook;Oh, Hyun-Mee;Kim, Jae-Wang;Shin, Hyun-Soo;Kwon, Chong-Suk;Kwun, In-Sook
    • Preventive Nutrition and Food Science
    • /
    • v.9 no.4
    • /
    • pp.374-382
    • /
    • 2004
  • The concern of the antioxidant micronutrient status in normal healthy people, including antioxidant trace minerals such as Cu, Zn, Mn, Fe and Se is focused since systemic oxidation is involved in various chronic diseases. In the present study, we evaluated the concentration of trace minerals (Cu, Zn, Mn, and Fe) which are considered as potential antioxidant minerals in plasma, red blood cells (RBCs) and urine in normal healthy Korean subjects. The 760 subjects (male 341, female 419; mean age 54.2 $\pm$ 18.9) were recruited from the rural, urban and metropolitan city in South Korea. Dietary intake was evaluated using 24-hours recall for general major nutrient intake assessment. The trace elements (Cu, Zn, Mn, and Fe) concentrations in plasma, RBCs, and urine were measured by inductively coupled plasma spectrophotometer (ICP) and atomic absorption spectrophotometer (AAS). Cu and Zn levels in plasma, RBCs and urine in normal healthy South Koreans were within the normal range of those mineral levels, but Mn and Fe levels were higher compared to the normal range of those mineral levels. None of the selected trace mineral levels in plasma and RBC's was lower than the normal range value. The results showed that Zn and Cu levels in plasma and RBC's in Korean were within the normal range, and plasma and urinary Mn and Fe levels were higher than the normal reference values. Potential antioxidant trace mineral (Cu, Mn, Zn and Fe) levels in Koreans are within or a bit higher than the normal range.

A noble RBC aggregometer with vibration-induced disaggregation mechanism

  • Shin S.;Jang J.H.;Park M.S.;Ku Y.H.;Suh J.S.
    • Korea-Australia Rheology Journal
    • /
    • v.17 no.1
    • /
    • pp.9-13
    • /
    • 2005
  • The aggregation of red blood cells (RBCs) is a major determinant of blood flow resistance passing through various veins. Available techniques for measuring RBC aggregation often require pretreating and washing after each measurement, which is not optimal for day-to-day clinical use. A laser reflection technique has been combined with a vibration-aided disaggregation mechanism, which shows significant advances in aggregometer design, operation and data analysis. The essential features of this design are in its simplicity and a disposable element that is in contact with the blood sample. Using extremely small quantities of blood, the RBCs subjected to vibrations can be quickly and completely disaggregated. This is followed by measuring the backscattered light intensity. The measurements with the present sensor were compared with those of a commercial aggregometer and a strong correlation was found between them. The newly-developed optical aggregometer can measure the RBC aggregability difference between young and old cell suspension with ease and accuracy.