• Title/Summary/Keyword: RAD18

Search Result 59, Processing Time 0.026 seconds

Development on a Relay Lens Type Scope with 70 mm Eye Relief (70 mm Eye Relief를 갖는 릴레이 렌즈 방식 스코프 개발)

  • Park, Seung-Hwan;Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.3
    • /
    • pp.29-35
    • /
    • 2009
  • Purpose: To develop a relay lens type scope with 70 mm eye relief. Methods: By using Sigma 2000 design program, we designed and manufactured a relay lens type scope with 70 mm eye relief, which is integrated after designing an objective part with relay lenses and an eyepiece part, respectively. Results: The characteristics of the relay lens type scope with 70 mm eye relief whch is designed and manufactured by methods, which integrate after respectively designing an object part with relay lenses and an eyepiece part, have the magnification of $+4{\times}$,the length from 1st lens to last lens of about 105 mm, the barrel diameter of 18mm, and the effective diameter of 13 mm. Also we know that the resolution line width is 275 cycles/rad at the 30% MTF value criterion. Conclusions: We could design and manufacture the relay type scope with 70 mm eye relief, the characteristics of which have the magnification of $+4.0{\times}$the MTF above 30% at 275 cycles/rad, and the length from 1st lens to last lens of about 105 mm.

  • PDF

A Parametric Study of Pulsed Gamma-ray Detectors Based on Si Epi-Wafer (실리콘 에피-웨이퍼 기반의 펄스감마선 검출센서 최적화 연구)

  • Lee, Nam-Ho;Hwang, Young-Gwan;Jeong, Sang-Hun;Kim, Jong-Yeol;Cho, Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.7
    • /
    • pp.1777-1783
    • /
    • 2014
  • In this paper, we designed and fabricated a high-speed semiconductor sensor for use in power control devices and analyzed the characteristics with pulsed radiation tests. At first, radiation sensitive circular Si PIN diodes with various diameters(0.1 mm ~5.0 mm) were designed and fabricated using Si epitaxial wafer, which has a $42{\mu}m$ thick intrinsic layer. The reverse leakage current of the diode with a radius of 2 mm at a reverse bias of 30 V was about 20.4 nA. To investigate the characteristic responses of the developed diodes, the pulsed gamma-radiation tests were performed with the intensity of 4.88E8 rad(Si)/sec. From the test results showing that the output currents and the rising speeds have a linear relationship with the area of the sensors, we decided that the optimal condition took place at a 2 mm diameter. Next, for the selected 2 mm diodes, dose rate tests with a range of 2.47E8 rad(Si)/sec to 6.21E8 rad(Si)/sec were performed. From the results, which showed linear characteristics with the radiation intensity, a large amount of photocurrent over 60mA, and a high speed response under 350ns without saturation, we can conclude that the our developed PIN diode can be a good candidate for the sensor of power control devices.

Analysis of Radiation Effects in CMOS 0.18um Process Unit Devices (CMOS 0.18um 공정 단위소자의 방사선 영향 분석)

  • Jeong, Sang-Hun;Lee, Nam-Ho;Lee, Min-Woong;Cho, Seong-Ik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.3
    • /
    • pp.540-544
    • /
    • 2017
  • In this study, we analyzed the effects of TID(Total Ionizing Dese) and TREE(Transient Radiation Effects on Electronics) on nMOSFET and pMOSFET fabricated by 0.18um CMOS process. The size of nMOSFET and pMOSFET is 100um/1um(W/L). The TID test was conducted up to 1 Mrad(Si) with a gamma-ray(Co-60). During the TID test, the nMOSFET generated leakage current proportional to the applied dose, but that of the pMOSFET was remained in a steady state. The TREE test was conducted at TEST LINAC in Pohang Accelerator Laboratory with a maximum dose-rate of $3.16{\times}10^8rad(si)/s$. In that test nMOESFET generated a large amount of photocurrent at a maximum of $3.16{\times}10^8rad(si)/s$. Whereas, pMOSFETs showed high TREE immunity with a little amount of photocurrent at the same dose rate. Based on the results of this experiment, we will progress the research of the radiation hardening for CMOS unit devices.

Gene Expression Biodosimetry: Quantitative Assessment of Radiation Dose with Total Body Exposure of Rats

  • Saberi, Alihossein;Khodamoradi, Ehsan;Birgani, Mohammad Javad Tahmasebi;Makvandi, Manoochehr
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.18
    • /
    • pp.8553-8557
    • /
    • 2016
  • Background: Accurate dose assessment and correct identification of irradiated from non-irradiated people are goals of biological dosimetry in radiation accidents. Objectives: Changes in the FDXR and the RAD51 gene expression (GE) levels were here analyzed in response to total body exposure (TBE) to a 6 MV x-ray beam in rats. We determined the accuracy for absolute quantification of GE to predict the dose at 24 hours. Materials and Methods: For this in vivo experimental study, using simple randomized sampling, peripheral blood samples were collected from a total of 20 Wistar rats at 24 hours following exposure of total body to 6 MV X-ray beam energy with doses (0.2, 0.5, 2 and 4 Gy) for TBE in Linac Varian 2100C/D (Varian, USA) in Golestan Hospital, in Ahvaz, Iran. Also, 9 rats was irradiated with a 6MV X-ray beam at doses of 1, 2, 3 Gy in 6MV energy as a validation group. A sham group was also included. After RNA extraction and DNA synthesis, GE changes were measured by the QRT-PCR technique and an absolute quantification strategy by taqman methodology in peripheral blood from rats. ROC analysis was used to distinguish irradiated from non-irradiated samples (qualitative dose assessment) at a dose of 2 Gy. Results: The best fits for mean of responses were polynomial equations with a R2 of 0.98 and 0.90 (for FDXR and RAD51 dose response curves, respectively). Dose response of the FDXR gene produced a better mean dose estimation of irradiated "validation" samples compared to the RAD51 gene at doses of 1, 2 and 3 Gy. FDXR gene expression separated the irradiated rats from controls with a sensitivity, specificity and accuracy of 87.5%, 83.5% and 81.3%, respectively, 24 hours after dose of 2 Gy. These values were significantly (p<0.05) higher than the 75%, 75% and 75%, respectively, obtained using gene expression of RAD51 analysis at a dose of 2 Gy. Conclusions: Collectively, these data suggest that absolute quantification by gel purified quantitative RT-PCR can be used to measure the mRNA copies for GE biodosimetry studies at comparable accuracy to similar methods. In the case of TBE with 6MV energy, FDXR gene expression analysis is more precise than that with RAD51 for quantitative and qualitative dose assessment.

A Novel Linearization Method of Sin/Cos Sensor Signals Used for Angular Position Determination

  • Zivanovi, Dragan;Lukic, Jelena;Denic, Dragan
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1437-1445
    • /
    • 2014
  • In this paper a novel method for angular position determination using sensors with sin/cos output and without an excitation signal, is presented. The linearization of the sensor transfer characteristic and digitalization of the measurement results are performed simultaneously with a goal to increase the measurement resolution. This improvement is particularly important for low angular velocities, and can be used to increase the resolution of incremental Hall, magnetic and optical sensors. This method includes two phases of sin/cos signal linearization. In the first linearization phase the pseudo-linear signal is generated. The second linearization phase, executed by the two-stage piecewise linear ADC, is an additional linearization of the pseudo-linear signal. Based on the LabVIEW software simulations of the proposed method, the contribution of each processing phase to a final measurement error is examined. After the proposed method is applied within $2{\pi}$ [rad] range, the maximal nonlinearity is reduced from 0.3307 [rad] ($18.9447^{\circ}$) to $3{\cdot}10^{-4}$ [rad] ($0.0172^{\circ}$).

Prognostic Value of 18F-FDG PET/CT Radiomics in Extranodal Nasal-Type NK/T Cell Lymphoma

  • Yu Luo;Zhun Huang;Zihan Gao;Bingbing Wang;Yanwei Zhang;Yan Bai;Qingxia Wu;Meiyun Wang
    • Korean Journal of Radiology
    • /
    • v.25 no.2
    • /
    • pp.189-198
    • /
    • 2024
  • Objective: To investigate the prognostic utility of radiomics features extracted from 18F-fluorodeoxyglucose (FDG) PET/CT combined with clinical factors and metabolic parameters in predicting progression-free survival (PFS) and overall survival (OS) in individuals diagnosed with extranodal nasal-type NK/T cell lymphoma (ENKTCL). Materials and Methods: A total of 126 adults with ENKTCL who underwent 18F-FDG PET/CT examination before treatment were retrospectively included and randomly divided into training (n = 88) and validation cohorts (n = 38) at a ratio of 7:3. Least absolute shrinkage and selection operation Cox regression analysis was used to select the best radiomics features and calculate each patient's radiomics scores (RadPFS and RadOS). Kaplan-Meier curve and Log-rank test were used to compare survival between patient groups risk-stratified by the radiomics scores. Various models to predict PFS and OS were constructed, including clinical, metabolic, clinical + metabolic, and clinical + metabolic + radiomics models. The discriminative ability of each model was evaluated using Harrell's C index. The performance of each model in predicting PFS and OS for 1-, 3-, and 5-years was evaluated using the time-dependent receiver operating characteristic (ROC) curve. Results: Kaplan-Meier curve analysis demonstrated that the radiomics scores effectively identified high- and low-risk patients (all P < 0.05). Multivariable Cox analysis showed that the Ann Arbor stage, maximum standardized uptake value (SUVmax), and RadPFS were independent risk factors associated with PFS. Further, β2-microglobulin, Eastern Cooperative Oncology Group performance status score, SUVmax, and RadOS were independent risk factors for OS. The clinical + metabolic + radiomics model exhibited the greatest discriminative ability for both PFS (Harrell's C-index: 0.805 in the validation cohort) and OS (Harrell's C-index: 0.833 in the validation cohort). The time-dependent ROC analysis indicated that the clinical + metabolic + radiomics model had the best predictive performance. Conclusion: The PET/CT-based clinical + metabolic + radiomics model can enhance prognostication among patients with ENKTCL and may be a non-invasive and efficient risk stratification tool for clinical practice.

Radiation Sensitivity of Some Food Decay Fungi (몇몇 음식 부식 균류의 방사선 감수성에 대한 연구)

  • 장학길;이배함
    • Korean Journal of Microbiology
    • /
    • v.18 no.1
    • /
    • pp.1-6
    • /
    • 1980
  • Five species of food decay fungl, Aspergillus flavus, Asp. uiger, Penicillum sp., Botrytis cinerea, and Rhizopus stolonifer, were examined for their radio sensitivity in several suspension media. Asp. flavus, Asp. niger and Penicillum sp. have almost the same sensitivity toward gamma rays. with D value in the range of 30 to 35 K rad, whereas Botrytis cinerea has a D value of approximately 55K rad and Rhizopus stolonifer, the most re4sistant fungus studied, has a crease in their radioresistnace when compared with spores irradiated in water. Asp. flavus and penicillium sp. spores irradiated in citrate buffer at pH3-7 showed almost no change in their radisensitiity with pH, but Botryis cinerea spores showed a distinct decrease in their radioresistnace at pH 6 and 7. Penicillum sp. spores irradiated in sucrose solutions showed no sinificant change in their radioresistance. Botrytis cinerea spores displayed a higher radioresistance when they were irradiated in sucrose solution than in water.

  • PDF

An Ultraprecision Rotary Motor based on Inchworm-type Actuation (인치웜 구동방법에 의한 초정밀 회전모터)

  • Kim, Sang-Chae;Kim, Soo-Hyun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.3
    • /
    • pp.152-157
    • /
    • 2001
  • An ultraprecision rotary motor is developed using inchworm motion of two belts actuated by elongation of piezoelectric elements. A symmetric lever mechanism with flexure hinges is designed to connect belts with piezoelectric elements. The lever mechanism is used not only to amplify the elongation of piezoelectric element but also to minimize the numbers of components and the effort for assembly. By experiment, the rotational angle by one cycle is varied from $0.2{\times}10-4 rad to 9.76{\times}10-4$ rad depending on input signal amplitude. Further, the motor has the capability of getting more precise rotational resolution by enlarging the radius of the rotor.

  • PDF

Identification of sex-specific SNPS in burbot Lota lota using RAD sequencing: conservation and management applications

  • Vu, Ninh V.;Eardley, Daniel L.;Delomas, Thomas A.;Campbell, Matthew R.
    • Fisheries and Aquatic Sciences
    • /
    • v.22 no.8
    • /
    • pp.18.1-18.5
    • /
    • 2019
  • The development of sex-specific genetic assays in a species provides both a method for identifying the system of sex determination and a valuable tool to address questions of conservation and management importance. In this study, we focused on the identification of single nucleotide polymorphisms (SNPs) that differentiate genetic sex in burbot Lota lota. Burbot are the only true freshwater representative of the cod family and a species of conservation and management importance throughout Eurasia and North America. To identify sex-specific SNPs, we utilized restriction site-associated DNA sequencing (RADseq) to interrogate thousands of SNPs in burbot samples of known phenotypic sex. We discovered 170,569 biallelic SNPs, none of which fit the pattern expected under female heterogamety. However, we identified 22 SNPs that fit the pattern expected under male heterogamety (males heterozygous XY, females fixed XX) and, from these, developed two genetic assays that robustly (~ 97% genotyping success) and accurately (> 99% correct) sexed burbot samples. These sex-specific genetic assays will benefit growing conservation aquaculture programs for this species and allow future assessments of sex-specific migration, growth, and mortality.

A CASE OF SQUAMOUS CELL CARCINOMA OF THE TRACHEA (기관에 발생한 편평상피암 1례)

  • 박윤석;엄재욱;박춘근
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1987.05a
    • /
    • pp.18.3-18
    • /
    • 1987
  • 기관의 원발성 종양은 매우 드물며 그 수술적 치료법 또한 확고히 되어 있지 않은 실정이다. 저자들은 기관지 천식으로 오진한 제1, 제2 기관륜 부위에 발생하여 윤상 연골까지 침범한 편평 세포암을 제1, 제2 기관륜을 포함하여 윤상 연골의 부분 절제후 6500 rad. 조사 후 좋은 경과를 보이고 있는 44세 여자 환자에 대해 문헌 고찰과 아울러 보고하는 바이다.

  • PDF