• Title/Summary/Keyword: RA test

Search Result 951, Processing Time 0.044 seconds

An Accuracy Analysis of Run-test and RA(Reverse Arrangement)-test for Assessing Surface EMG Signal Stationarity (표면근전도 신호의 정상성 검사를 위한 Run-검증과 RA-검증의 정확도 분석)

  • Lee, Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.2
    • /
    • pp.291-296
    • /
    • 2014
  • Most of the statistical signal analysis processed in the time domain and the frequency domain are based on the assumption that the signal is weakly stationary(wide sense stationary). Therefore, it is necessary to know whether the surface EMG signals processed in the statistical basis satisfy the condition of weak stationarity. The purpose of this study is to analyze the accuracy of the Run-test, modified Run-test, RA(reverse arrangement)-test, and modified RA-test for assessing surface EMG signal stationarity. Six stationary and three non-stationary signals were simulated by using sine wave, AR(autoregressive) modeling, and real surface EMG. The simulated signals were tested for stationarity using nine different methods of Run-test and RA-test. The results showed that the modified Run-test method2 (mRT2) classified exactly the surface EMG signals by stationarity with 100% accuracy. This finding indicates that the mRT2 may be the best way for assessing stationarity in surface EMG signals.

Bridge Monitoring System based on LoRa Sensor Network (LoRa 센서네트워크 기반의 무선교량유지관리 시스템 구축)

  • Park, Jin-Oh;Park, Sang-Heon;Kim, Kyung-Soo;Park, Won-Joo;Kim, Jong-Hoon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.33 no.2
    • /
    • pp.113-119
    • /
    • 2020
  • The IoT-based sensor network is one of the methods that can be efficiently applied to maintain the facilities, such as bridges, at a low cost. In this study, based on LoRa LPWAN, one of the IoT communications, sensor board for cable tension monitoring, data acquisition board for constructing sensor network along with existing measurement sensors, are developed to create bridge structural health monitoring system. In addition, we designed and manufactured a smart sensor node for LoRa communication and established a sensor network for monitoring. Further, we constructed a test bed at the Yeonggwang Bridge to verify the performance of the system. The test bed verification results suggested that the LoRa LPWAN-based sensor network can be applied as one of the technologies for monitoring the bridge structure soundness; this is excellent in terms of data rate, accuracy, and economy.

Optimal Signal Segment Length for Modified Run-test and RA(reverse arrangement)-test for Assessing Surface EMG Signal Stationarity (표면근전도 신호의 정상성 검사를 위한 수정된 Run-검증과 RA-검증에 최적인 신호분할 길이)

  • Lee, Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.8
    • /
    • pp.1128-1133
    • /
    • 2014
  • Most of the statistical signal analysis processed in the time domain and the frequency domain are based on the assumption that the signal is weakly stationary(wide sense stationary). Therefore, it is necessary to know whether the surface EMG signals processed in the statistical basis satisfy the condition of the weak stationarity. The purpose of this study is to find optimal segment length of surface EMG signal for assessing stationarity with the modified Run-test and RA-test. Ten stationary surface EMG signals were simulated by AR(autoregressive) modeling, and ten real surface EMG signals were recorded from biceps brachii muscle and then modified to have non-stationary structures. In condition of varying segment length from 20ms to 100ms, stationarity of the signals was tested by using six different methods of modified Run-test and RA-test. The results indicate that the optimal segment length for the surface EMG is 30ms~35ms, and the best way for assessing surface EMG signal stationarity is the modified Run-test (Run2) method using this optimal length.

Bridge Wireless Measurement System Development based on LoRa IoT (LoRa IoT 기반의 교량 무선 자동계측 시스템 개발)

  • Park, Jin-o;Park, Sang-Heon;An, Sung-Ju;Park, Won-Joo;Kim, Jong-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.7
    • /
    • pp.164-171
    • /
    • 2019
  • Focusing on the bridge facilities, which occupy the largest proportion among SOC public facilities in Korea, it is possible to reduce the cost compared to existing wired measurement systems or wireless measurement systems developed by domestic telecommunications companies, and to increase the technical perfection to be applied to many bridges. We developed a wireless measurement system for bridges. Using LoRa, one of the unlicensed LPWAN technologies, we have developed an optimized MEMS-based LoRa smart sensor node considering the domestic ISM band and the existing wired sensor LoRa DAQ sensor node that can communicate with the LoRa network. Application server was developed for the test bed performance verification and efficient management of the developed sensor node.

Experimental Evaluation on Occurrence Possibility of Pollutants from Aggregates (순환골재의 오염물질 발생 가능성에 관한 실험적 평가)

  • Park, Jeong-Ho;Seong, Jin-Uk;Park, Je-Chul
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.1 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • This study was on leaching test(KSLT, TCLP) of the aggregate for the products(RA-1) and for the site(RA-2) to evaluate the characteristics of contaminants and the possibility of contamination arising from the aggregate. On the basis pH, conductivity and heavy metal contents in the aggregate, RA-1 indicated higher than RA-2. As a result of the leaching test, the pollutants were eluted from the aggregate increased as the particle size of the aggregate was smaller. The pH in the aggregate had a strong alkali by a pH value of 9.0~12.3, the conductivity was higher in less than 10mm RA-1 due to the leaching of dissolved inorganic ions. The heavy metals satisfied the leaching standards of KSLT and less 10% was eluted from the aggregate. As a result of evaluating water pollution possibility of the aggregate, the pH displayed in items with a very high possibility of contamination, conductivity and turbidity did in item with a low possibility of contamination and on the other hand the heavy metals did in item with a very low possibility of contamination.

A Very Efficient Redundancy Analysis Method Using Fault Grouping

  • Cho, Hyungjun;Kang, Wooheon;Kang, Sungho
    • ETRI Journal
    • /
    • v.35 no.3
    • /
    • pp.439-447
    • /
    • 2013
  • To increase device memory yield, many manufacturers use incorporated redundancy to replace faulty cells. In this redundancy technology, the implementation of an effective redundancy analysis (RA) algorithm is essential. Various RA algorithms have been developed to repair faults in memory. However, nearly all of these RA algorithms have low analysis speeds. The more densely compacted the memory is, the more testing and repair time is needed. Even if the analysis speed is very high, the RA algorithm would be useless if it did not have a normalized repair rate of 100%. In addition, when the number of added spares is increased in the memory, then the memory space that must be searched with the RA algorithms can exceed the memory space within the automatic test equipment. A very efficient RA algorithm using simple calculations is proposed in this work so as to minimize both the repair time and memory consumption. In addition, the proposed algorithm generates an optimal solution using a tree-based algorithm in each fault group. Our experiment results show that the proposed RA algorithm is very efficient in terms of speed and repair.

A Fast Redundancy Analysis Algorithm in ATE for Repairing Faulty Memories

  • Cho, Hyung-Jun;Kang, Woo-Heon;Kang, Sung-Ho
    • ETRI Journal
    • /
    • v.34 no.3
    • /
    • pp.478-481
    • /
    • 2012
  • Testing memory and repairing faults have become increasingly important for improving yield. Redundancy analysis (RA) algorithms have been developed to repair memory faults. However, many RA algorithms have low analysis speeds and occupy memory space within automatic test equipment. A fast RA algorithm using simple calculations is proposed in this letter to minimize both the test and repair time. This analysis uses the grouped addresses in the faulty bitmap. Since the fault groups are independent of each other, the time needed to find solutions can be greatly reduced using these fault groups. Also, the proposed algorithm does not need to store searching trees, thereby minimizing the required memory space. Our experiments show that the proposed RA algorithm is very efficient in terms of speed and memory requirements.

Algorithms for Detecting Coupling Faults in Semiconductor RAM's (반도체 RAM의 결합고장을 검출하는 알고리듬)

  • 여정모;조상복
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.1
    • /
    • pp.51-63
    • /
    • 1993
  • "Algorithm DA" is proposed to test linked 2-CFs(2-Coupling Faults) with order 2 or 3 which are not perfectly detected in conventional algorithms. "Test 1*", "Test 2*" and "Algorithm RA" are proposed restricted 3-CFS. The time complexity of "Test 1*" is reduced in view of the detection of 3-CFS. "Test 2*" and "Algorithm RA" have not only the reduces time complexity but also the improved fault coverage in comparison with conventional algorithms. And "Algorithm RA" can be applied step by step according to the degree of the fault coverage. If "Algorithm RA" is applied to the memory with parallel test. its time complexity is reduced considerably. It is proved that the MT(March Test) with nonlinear address sequences can not detect perfectly the CFs more complex than linked 2-CFs with order 3.ss sequences can not detect perfectly the CFs more complex than linked 2-CFs with order 3.

  • PDF

EVALUATION ON THE ABRASION RESISTANCE OF A SURFACE SEALANT (레진전색제의 마모저항성에 대한 평가)

  • Kim, Soo-Mee;Han, Sae-Hee;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.3
    • /
    • pp.180-190
    • /
    • 2007
  • The purpose of this study was to evaluate the abrasion resistance of surface penetrating sealant which was applied on a composite resin restoration and to provide proper time to reapply sealant on composite resin surface. Two hundred rectangular specimens, sized $8\times3\times2mm$, were made of Micronew (Bisco, Inc., Schaumburg, IL, U.S.A) and divided into two groups; F group (n = 10) was finished with coarse and medium grit of Sof-Lex discs and BisCoverwas applied B group (n = 190) after finishing with discs. B group was again subdivided into nineteen subgroups From B-1 group to B-18 group were subjected to toothbrush abrasion test using a distilled water-dentifrice slurry and toothbrush heads B-IM group was not subjected to toothbrush abrasion test. Average surface roughness (Ra) of each group was calculated using a surface roughness tester (Surfcorder MSE-1700: Kosaka Laboratory Ltd., Tokyo, Japan) . A representative specimen of each group was examined by FE-SEM (S-4700: Hitachi High Technologies Co., Tokyo, Japan). The data were analysed using cluster analysis, paired t-test, and repeated measure ANOVA. The results of this study were as follows; 1. Ra off group was $0.898{\pm}0.145{\mu}m$ and B-IM group was $0.289{\pm}0.142{\mu}m$. Ra became higher from B-1 group $(0.299{\pm}0.48{\mu}m$ to B-18 group $(0.642{\pm}0.313{\mu}m$. 2. Final cluster center of Ra was $0.361{\mu}m$ in cluster 1 $(B-IM\simB-7)$, $0.511{\mu}m$ in cluster 2 $(B-8\simB-14)$ and $0.624{\mu}m$ in cluster 3 ($(B-15\simB-18)$. There were significant difference among Ra of three clusters. 3 Ra of B-IM group was decreased 210.72% than Ra of F group. Ra of B-8 group and B-15 group was increased 35.49% and 51.35% respectively than Ra of B-IM group. 4. On FE-SEM, B-IM group showed the smoothest resin surface. B-8 group and B-15 group showed vertically shallow scratches , and wide and irregular vertical scratches on composite resin surface respectively. Within a limitation of this study, finished resin surface will be again smooth and glazy if BisCover would be reapplied within 8 to 14 months after applying to resin surface.

Negative Association between Schizophrenia and Rheumatoid Arthritis : Epidemiology and Prolactin and Estrogen as Protective Factors (정신분열병과 류마치스 관절염 사이의 음성적 상관관계 : 역학 및 방어적 요인으로서 Prolactin과 Estrogen)

  • Ahn, Dong-Sung;Lee, Young-Ho;Lee, Yoon-Woo
    • Korean Journal of Biological Psychiatry
    • /
    • v.6 no.1
    • /
    • pp.125-134
    • /
    • 1999
  • The purposes of this study were to test the negative association between schizophrenia and rheumatoid arthritis(RA) and to clarify the role of prolactin and estrogen as protective factors in this association. The author compared the prevalence rate of RA between 561 patients with schizophrenia and 222 patients with mood disorder. For investigating the role of estrogen and prolactin, the author checked the plasma prolactin and estradiol level in 80 patients with paranoid schizophrenia and 77 patients with RA. The results were as follows. 1) Epidemiological data The prevalence rate of RA in the schizophrenic group was 0/561 and that of RA in the mood disorder group was 2/222. To compare these results between two groups, the author applied the Binomial test using the average prevalence rate of RA(0.8%) in the general population as a reference rate. The prevalence rate of RA in the schizophrenic group was significantly lower than that of RA in the general population. However, the prevalence rate of RA in the mood disorder group was not significantly different to that of RA in the general population. 2) Comparison of plasma prolactin and estradiol level between two groups The plasma level of prolactin in the schizophrenic group was significantly higher than that of prolactin in the RA group(p=0.000). However, the plasma level of estradiol in the schizophrenic group was significantly lower than that of estradiol in the RA group(p=0.017). These results were not consistent across gender. To contrast with the results in the female group, which were consistent with the results in the total subjects, for the male group, the plasma levels of prolactin and estradiol in the schizophrenic group were significantly higher than those of prolactin and estradiol in the RA group. These results support the results of previous studies which confirm the negative association between schizophrenia and RA. These results also suggest that the elevation of plasma prolactin level in the patients with schizophrenia has a antirheumatic effect while the elevation of plasma estradiol level in the patients with RA has a anti-schizophrenic effect, and that these effects act as a possible mechanism in the negative association between two disorders. However, these results suggest that this association is specific to female patients.

  • PDF