• 제목/요약/키워드: R410a

검색결과 305건 처리시간 0.038초

EES를 이용한 대체냉매 작동 2단압축냉동사이클의 성능해석 (Two-Stage compression cycle operating with alternative refrigerant using by EES program)

  • 박천완;이동규;최승길;강채동
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.533-538
    • /
    • 2009
  • The present study has been conducted to an analysis of two stage refrigeration cycle with alternative refrigerant R410A. In the analysis, single stage cycle (R22 and R410A) compared to COP changing with supercooling degree. Secondly, two stage refrigeration cycle is investigated to the existence of intercooler or supercooler. At results, supercooler contributes to the increase of cooling capacity and the decrease of COP.

  • PDF

열전달 촉진관에서 R22 대체냉매 및 R134a의 포화증기 온도변화에 따른 외부 응축 열전달계수에 관한 연구 (External Condensation Heat Transfer Coefficients of R22 Alternative Refrigerants and R134a According to the Saturated Vapor Temperature Change on an Enhanced Tube)

  • 유길상;황지환;박기정;정동수
    • 설비공학논문집
    • /
    • 제17권11호
    • /
    • pp.981-989
    • /
    • 2005
  • In this study, external condensation heat transfer coefficients (HTCs) are measured on a low fin tube and Turbo-C tubes at the saturated vapor temperature of $30^{\circ}C$, $39^{\circ}C$, and $50^{\circ}C$ for R22, R410A, R407C and R134a with the wall subcooled at $3{\~}8^{\circ}C$. The HTCs of all refrigerants decreased as increasing the saturation temperature from $30^{\circ}C$ to $50^{\circ}C$. This trend is due to better thermodynamic properties of the liquid phase at low temperature Beatty and Katz's prediction yielded a $20.0\%$ deviation for the low fin tube data. The heat transfer enhancement factors for the 26 fpi low fin tube and Turbo-C tubes are 4.0${\~}$5.5 and 3.0${\~}$8.1 respectively for the refrigerants tested. Finally the performance of Turbo-C tube is better than that of the low fin tube.

Rheological Properties of Exopolysaccharide EPS-R Produced by Marine Bacterium Hahella chejuensis KCTC 2395

  • Ahn, Se-Hun;Yim, Joung-Han;Kim, Sung-Jin;Lee, Hong-Kum
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2001년도 추계학술발표대회
    • /
    • pp.808-811
    • /
    • 2001
  • The rheological properties of exopolysaccharide(EPS-R) produced by marine bacteria Hahella chjuensis KCTC 2395 was investigated. EPS-R solution showed a characteristic non-Newtonian behavior fluid properties. In aqueose dispersions of EPS-R 1%, consistency index(K) and flow behavior index(n) were 1,410 cp and 0.73. EPS-R solution was pseudoplastic fluid by power-low model. Rheological propertie of EPS-R was found to be influenced by the concentration of salt, pH, temperature and ionic compounds.

  • PDF

PF열교환기에서 R410A 냉매분배의 영향 (Analysis of R410A refrigerant distribution in parallel flow heat exchanger)

  • 김정식;김내현
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.340-345
    • /
    • 2008
  • A computer program, which simulates the parall flow evaporator was developed. The program was having used to simulate the sample $650\;mm{\times}190\;mm$ frontal area, 25 mm flow depth and 3.0 mm fin pitch. It was shown that the cooling capacity of 3kW could be available from the sample. The present model, however, does not consider refrigerant mal-distribution in each pass, which is known to reduce the cooling capacity of the parallel flow heat exchanger.

  • PDF

질량비가 작은 접촉쌍성 V410 Aur과 V776 Cas-II (LOW MASS RATIO CONTACT BINARY V410 Aur AND V776 Cas-II)

  • 오규동;김천휘;김호일
    • Journal of Astronomy and Space Sciences
    • /
    • 제22권3호
    • /
    • pp.223-232
    • /
    • 2005
  • 질량비가 작은 접촉쌍성 V410 Aur과V776 Cas를 소백산천문대의 61cm망원경에 2K CCD 카메라를 부착하여 측광 관측을 하였으며, 그 결과 이 별들의 새로운 3색(BVR)의 완전한 광도곡선을 얻었다. 새로운 광도곡선과 이미 발표된 분광관측으로부터 WD모델을 이용하여 이 두 별의 궤도요소와 절대 물리량을 얻었다. V410 Aur과 V776 Cas를 포함한 절대물리량이 잘 알려진 19개의 질량비가 작은 접촉쌍성들의 진화 상태를 조사하였다. 그 결과 질량비가 작은 접촉쌍성의 주성은 대부분 TAMS상에 놓이며 반성은 ZAMS 아래 놓이고 있음을 재확인하였다.

비공비 혼합냉매 R-410A를 적용한 납작한 알루미늄 마이크로 멀티 튜브에서의 마찰손실에 관한 연구 (A study on the friction head loss in flat aluminum micro multi tubes with nonazeotropic refrigerant mixtures R-410A)

  • 이정근;민경호
    • Design & Manufacturing
    • /
    • 제13권2호
    • /
    • pp.37-43
    • /
    • 2019
  • This study conducted a research as to condensation heat transfer friction loss headby using three types of flat micro multi-channel tubes with different processing of micro-fin and number of channels inside the pipes and different sizes of appearances. In addition, identical studies were conducted by using smoothing circular tubes with 5mm external diameter to study heat enhancement factor and pressure drop penalty factor. 1) The friction head loss showed an increase as the vapor quality and mass flux increased. In case of saturation temperature, it shows an increase as it gets lower. These factors are the reason occurring as the lower the saturation temperature is, the higher the density of refrigerant vapor gets. The influence of heat flux is similar as the dryness is low, but as it gets higher, it lowers in heat flux, and as the high temperature of high heat flux, it is a factor that occurs as the density gets lower. 2) RMS error of the in case of friction head loss, it showed to be predicted as 0.45~0.67 by Chisholm, Friedel, Lockhart and Martinelli. 3) As forfriction head loss penalty factor, the smaller the aspect ratio is, the larger the penalty factor gets, and as for the effect of micro-fin, the penalty factor increased because it decreases to the gas fluid the way groove for the refrigerant's flow.

열전달 촉진관에서 대체냉매의 비등열전달계수 (Pool boiling heat transfer coefficients of alternative refrigerants in enhanced tubes)

  • 이준강;고영환;정동수;송길홍;김종보
    • 대한기계학회논문집B
    • /
    • 제22권7호
    • /
    • pp.980-991
    • /
    • 1998
  • In this study, nucleate pool boiling heat transfer coefficients of alternative refrigerants on a plain, low fin, and two enhanced tubes were measured and compared against each other. To obtain data at conditions similar to the actual evaporator, a fluid heating method was employed instead of an electric heating method in the experiments. R123, R134a, R22 and R410a were used as working fluids and data were taken at 7 deg.C ar heat fluxes of 20 ~ 100 kW/m$\^$2/. Comparison of the plain tube data against some correlations showed that the simplest correlation of Cooper based on reduced pressure predicted the data for all fluids tested with a 10% deviation. For all refrigerants, enhanced tubes composed of subsurface and subtunnels, especially Thermoexcel-E tube, showed the highest heat transfer coefficients among the tubes tested with one exception that the low fin tube's performance was better than those of enhanced tubes for high vapor pressure fluid such as R410a at high heat flux. Finally, a low fin and enhanced tubes showed higher heat transfer enhancement for low vapor pressure of R123 than for high vapor pressure fluisd. For R123, the enhancement factors for Turbo-B and Thermoexcel-E tubes were 2.8 ~ 4.8 and 4.6 ~ 8.1 respectively.

알루미늄 다채널 평판관내 R22 대체냉매의 흐름 응축 열전달 성능 비교 (Flow Condensation Heat Transfer Coefficients of R22 Alternative refrigerants in Aluminum Multi-Channel Tube)

  • 이기영;이민행;정동수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.249-255
    • /
    • 2005
  • Flow condensation heat transfer coefficients(HTCs) of R22, R4IO, Propane(R290) were measured inside a horizontal 9 hole aluminum multi-channel flat tube. The main test section in the refrigerant loop was made of a 0.53 m long multi-channel flat tube of hydraulic diameter of 1.4 mm. Refrigerant was cooled by passing cold water through an annulus surrounding the test section. Data were obtained in qualities of 0.1 ${\sim}$ 0.9 at mass flux of $200{\sim}400$ $kg/m^2s$ and heat flux of $7.3{\sim}7.7$ $kW/m^2$ at the saturation temperature of $4^{\circ}C$. All popular heat transfer correlations in single-phase subcooled liquid flow and flow condensation originally developed for large single tubes predicted the present data of the multi channel flat tube within 25% deviation when effective heat transfer area was used in determining experimental data. This suggests that there is little change in flow characteristics and patterns when the tube diameter is reduced down to 1.4 mm diameter range. Hence, a modified correlation based on the present data was proposed which could be applied to small diameter tubes with effective heat transfer area. The correlation showed a mean deviation of less than 20% for all data.

  • PDF

A Generalized Correlation and Rating Charts for Mass Flow Rate through Capillary Tubes with Several Alternative Refrigerants

  • Choi Jong Min;Jang Yong Hee;Kim Yongchan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권4호
    • /
    • pp.192-197
    • /
    • 2004
  • A capillary tube, which is a common expansion device in small sized refrig-eration and air-conditioning systems, should be redesigned properly to establish an optimum operation cycle of a refrigerating system with alternative refrigerants. Based on experimental data for R-22, R-290, and R-407C, an empirical correlation is developed to predict mass flow rate through capillary tubes. Dimensionless parameters are derived from the Buckingham Pi theorem, considering the effects of operating conditions and capillary tube geometry on mass flow rate. Approximately $97\%$ of the present data are correlated within a relative deviation of $\pm\;10\%.$ The present correlation also predicts the data obtained from open literature within $\pm\;15\%.$ In addition, rating charts of refrigerant flow rate for R-12, R-22, R-134a, R-152a, R-407C, R-410A, R-290, and R-600a are developed.

대체냉매를 적용한 일반화된 모세관의 유량예측 상관식 (A Generalized Empirical Correlation on the Mass Flow Rate through Adiabatic Capillary Tubes with Alternative Refrigerants)

  • 최종민;장용희;김용찬
    • 설비공학논문집
    • /
    • 제15권9호
    • /
    • pp.744-750
    • /
    • 2003
  • The performance of adiabatic capillary tubes are measured to provide the database for a generalized correlation. Test conditions and capillary tube geometries are selected to cover a wide range typically observed in air-conditioning and heat pump applications. Based on extensive experimental data for R22, R290, and R407C measured in this study, a generalized correlation for refrigerant flow rate in adiabatic capillary tubes is developed by implementing dimensionless parameters for tube inlet conditions, capillary tube geometry, and refrigerant properties. The correlation yields good agreement with the present data for R22, R290, and R407C with average and standard deviations of 0.9% and 5.0%, respectively. In addition, approximately 97% of the data for Rl2, R134a, R152a, R410A, and R600a obtained in the open literature are correlated within a relative deviation of $\pm$ 15%.