• 제목/요약/키워드: R123

검색결과 674건 처리시간 0.023초

수평 평활관내 R245fa의 흐름 응축 열전달 특성 (Flow Condensation Heat Transfer Characteristic of R245fa in a Horizontal Plain Tube)

  • 박현신;박기정;정동수
    • 설비공학논문집
    • /
    • 제20권2호
    • /
    • pp.87-96
    • /
    • 2008
  • Flow condensation heat transfer coefficients(HTCs) of R123 and R245fa are measured in a horizontal plain tube. The main test section in the experimental flow loop is made of a plain copper tube of 9.52 mm outside diameter and 530 mm length. The refrigerant is cooled by passing cold water through an annulus surrounding the test section. Tests are performed at a fixed saturation temperature of $50\;{\pm}\;0.2\;^{\circ}C$ with mass fluxes of 50, 100, $150\;kg/m^2s$ and heat flux of $7.3{\sim}7.7\;kW/m^2$. Heat transfer data are obtained in the vapor quality range of $10{\sim}90%$. Test results show that the flow condensation HTCs of R245fa are overall 7.9% higher than those of R123 at all mass fluxes. The pressure drop of R245fa is smaller than that of R123 at the same heat flux. In conclusion, R245fa is a good candidate to replace ozone depleting R123 currently used in chillers from the view point heat transfer and environmental properties.

대체혼합냉매를 사용하는 Lorentz-Meutzner의 이중 증발기 냉동 시스템의 성능에 관한 연구 (A Study of Lorentz-Meutzner's Two Evaporator Refrigeration System Using Alternative Refrigerant Mixtures)

  • 박영무
    • 설비공학논문집
    • /
    • 제4권2호
    • /
    • pp.123-136
    • /
    • 1992
  • A preliminary thermodynamic design model of two-evaporator refrigerator/freezer system is constructed. This system is based on Lorentz-Meutzner cycle using refrigerant mixtures. This model screens alternative refrigerant (R32, R125, R143a, R22, R134a, R152a, R124, R142b, R123) mixtures to select the best performance-giving refrigerant mixtures and its composition for the system. Also, it estimates the effects of cooling temperatures of intercoolers, evaporator's area ratio, cooling load ratio on the performance of the system. The COP of the system ranges from 1.4 to 1.6, which is superior to that of the single evaporator system charged with R12 by 13% to 29%. Among 15 mixtures, R22/R123, R143a/R123, R32/R142b, and R32/R124 (in the order of high COP) are most recommendable. For the case of R22/R123, R22 mass fraction more than 0.5(Load Ratio=1.0) or 0.7(Load Ratio=0.33) is recomended in order to replace R12 without reduction in volumetric capacity when keeping the compressor as the same one. COP has the highest value with X(R22)=0.7 and 0.8, respectively. For the case of R143a/R123, in the similar manner, mass fraction of R143a is more than 0.5 or 0.6 while best performance occurs at X(R143a)=0.8. Higher temperature intercooler is more important for the performance of the system than lower temperature intercooler. The area ratio of evaporators is roughly proportional to load ratio of the evaporators.

  • PDF

대체냉매를 적용한 대형 압축식 냉동기의 만액식 증발기에 대한 성능 해석 (Performance Analysis of the Flooded Refrigerant Evaporators for Large Tonnage Compression-Type Refrigerators Using Alternative Refrigerants)

  • 김내현
    • 한국산학기술학회논문지
    • /
    • 제17권6호
    • /
    • pp.18-25
    • /
    • 2016
  • 대형 압축식 냉동기의 증발기 전열관으로는 그간 평활관이 주로 사용되어 왔으나 최근들어 비등 성능이 우수한 성형 가공관을 많이 사용하고 있다. 증발기는 관군으로 구성되고 따라서 증발기 내 위치에 따라 냉매 상태가 다르다. 특히 R-11, R-123과 같은 저압 냉매는 압력변화에 따른 포화온도 변화가 크므로 위치에 따라 포화온도가 다르게 된다. 따라서 증발기를 적절히 설계하려면 증발기 내 각 위치에서의 냉매의 상태를 적절히 예측하여야 한다. 본 연구에서는 대형 냉동기의 만액식 증발기를 모사할 수 있는 컴퓨터 프로그램을 개발하였다. 이 프로그램은 증발기를 미소 체적으로 구분하고 각 미소 체적에 적절한 관 내외측 열전달 및 압력손실 상관식을 적용하여 해석을 수행하였다. 본 프로그램을 R-123을 사용하는 T사의 만액식 증발기 해석에 적용한 결과 만족할 만한 결과를 얻었다. 이 프로그램을 이용하여 신 냉매인 R-123, R-134a를 사용하는 만액식 증발기의 해석을 수행하였고 특히 관군 세장비의 영향을 검토하였다.

만액식 증발기용 성형가공관의 풀비등 성능 (Pool Boiling Performance of Enhanced Tubes for a Flooded Evaporator)

  • 김내현;김태형;박운진
    • 대한기계학회논문집B
    • /
    • 제24권1호
    • /
    • pp.124-131
    • /
    • 2000
  • In this study, pool boiling performance of Turbo/B-type metal-formed tubes was investigated. Tubes with three different cavity gap width(0.04 mm, 0.07 mm, 0.1 mm) were manufactured and tested using R-11, R-123 and R-134a. Tests were conducted at two different saturation temperatures $4.4^{\circ}C$ and $26.7^{\circ}C.$ Heat flux was varied from 10 kW/m2 to 50 kW/m2. It was found that optimum gap width varied for different refrigerants. For low-pressure refrigerants such as R-11 or R-123, optimum gap width was 0.07 mm. For high-pressure refrigerant R-134a, however, the optimum value was 0.1 mm. Compared with the heat transfer performance of the smooth tube, the metal-formed tubes enhanced the heat transfer coefficients significantly - 6.5 times for R-11, 6.0 times for R-123 and 5.0 times for R-134a (at $4.4^{\circ}C$ saturation temperature and 40 kW/m2 heat flux), which are comparable with the performance of foreign products. The heat transfer coefficients of R-134a were larger than those of R-11 or R-123, and they increased as the saturation temperature increased.

다공판을 사용한 R-123 풀비등 열전달 촉진 (Pool Boiling Enhancement of R-123 Using Perforated Plates)

  • 김내현
    • 대한기계학회논문집B
    • /
    • 제40권5호
    • /
    • pp.275-281
    • /
    • 2016
  • 본 연구에서는 비등표면 위에 다공판을 설치하여 풀비등을 촉진시키는 방안에 대하여 검토하였다. 실험은 대기압에서 R-123을 사용하여 수행되었다. 다공판은 풀비등을 현저히 촉진시켰다. 이는 다공판이 기포를 비등표면 위에 넓게 퍼뜨려 기포와 비등표면 사이 액막의 면적을 증가시키기 때문이다. 또한 높은 열유속에서는 다공도가 클수록, 낮은 열유속에서는 다공도가 작을수록 비등이 촉진되었다. 본 연구에서는 구멍 직경 2.0 mm, 구멍 간격 $2.5mm{\times}5.0mm$ 또는 $5.0mm{\times}5.0mm$, 비등 표면과의 간격 0.5 mm에서 최적 형상이 얻어졌고 이 형상들의 열전달계수는 상용 GEWA-T의 값에 근접하였다. R-123에서의 최적 다공도는 물이나 에탄올에서 보다 현저히 큰데 이는 R-123의 밀도비가 크고 증발잠열은 작기 때문이다. 한편 다공판의 비등이력은 평판보다 작았다.

R123 열원 적용 증발식 담수 시스템 특성 연구 (Characteristics of Solar Desalination System Using Refrigerant-123 As a Heating Source)

  • 윤상국;곽희열
    • 한국태양에너지학회 논문집
    • /
    • 제30권3호
    • /
    • pp.33-38
    • /
    • 2010
  • The evaporative desalination system using solar thermal energy would be the efficient and attractive method to get fresh water from brine due to low carbon dioxide generation. In this research the solar desalination system as a heating source of refrigerant R123 in the evaporator was considered. The circulation of refrigerant in the evaporator can reduce the energy consumption of the system, because of using the latent heat of the refrigerant 123 instead of the sensible heat of present hot water. The system was comprised of the single-stage fresh water production unit on the capacity of 1ton/day with shell and tube type evaporator, heaters instead of solar collector to supply the proper heat to refrigerant, and refrigerant and brine circulation systems. Various operating flowrate and temperature ranges were varied in the experiments to get the optimum design data. The results showed that the optimum flow rate of brine feed rate to evaporator was 1.2Liter/min, and the yield of fresh water was increased as higher temperature of feed brine. It was confirmed that the circulation flowrate of heating source of refrigerant was decrease of one fifth of the present warm water system, and very efficient system for solar desalination.

평활관군 내 R-123/오일의 흐름비등 (Flow Boiling of R-123/Oil Mixture in a Plain Tube Bundle)

  • 이진욱;이재호;김내현
    • 설비공학논문집
    • /
    • 제22권10호
    • /
    • pp.704-709
    • /
    • 2010
  • The effect of oil on flow boiling of R-123 in a plain tube bundles was experimentally investigated for a range of quality and heat flux. It is shown that the heat transfer coefficient decreased as the oil concentration increased. Comparison with the previous pool boiling data reveals that the reduction of heat transfer coefficient by oil is more pronounced in pool boiling, and the difference increased with the increase of oil concentration and heat flux. Within the experimental range, the variation of mass flux or quality has negligible effect on the heat transfer coefficient.

[I-123]IPT SPECT를 이용한 정상인과 파킨슨 환자의 도파민 운반체의 영상화 및 단순화된 정량분석 방법들의 비교연구 (A Study of Dopamine Transporter Imaging and Comparison of Noninvasive Simplified Quantitative Methods in Normal Controls and Parkinson's Patients)

  • 봉정균;김희중;임주혁;양승오;문대혁;류진숙;남기표;천준홍;권수일;이희경
    • 대한핵의학회지
    • /
    • 제30권3호
    • /
    • pp.315-324
    • /
    • 1996
  • 목적 : 정상인과 파킨슨 환자의 [I-123]IPT SPECT 데이터를 이용하여 그래픽 분석방법과 축적된 특이결합과 비특이결합의 면적에 대한 비율을 이용한 분석방법으로 얻은 $k_3/k_4$와 조직방사능비를 비교하고 [I-123]IPT SPECT의 유용성을 알아보기 위한 것이다. 방법 : [I-123]IPT($6.5{\pm}1.1$ mCi)를 6명의 정상인(나이:$45{\pm}13$)과 17명의 파킨슨 환자(나이:$55{\pm}8$)에게 순간 정맥주사하였다. SPECT 데이터는 5분 간격으로 2시간 동안 얻어졌다. 운반체 매개변수 $k_3/k_4$는 동적 IPT SPECT 데이터를 이용 혈액 표본이 사용되지 않는 Ichise의 그래픽분석방법($R_v$)과 Lassen의 면적비율방법($R_A$)를 이용하여 얻어졌다. 운반체 매개변수 $R-v,\;R_A$ 그리고 115분에서 얻은(BG-OCC)/OCC비 사이의 관계들은 선형회귀분석을 사용하였다. 결과 : 정상인과 파킨슨 환자에 대한 $R_v$ 값은 각각 $2.08{\pm}0.29$$0.78{\pm}0.31$이었다. 그리고 $R_A$ 값은 정상인과 파킨슨 환자에 대해 각각 $1.48{\pm}0.16$$0.65{\pm}0.24$이었다. (BG-OCC)/OCC와 $R_v$,(BG-OCC)/OCC와 $R_A$ 그리고 $R_v$$R_A$ 사이의 상관계수들은 각각 0.93, 0.90, 0.99이었고, 그것들에 대응하는 기울기들은 각각 0.54, 0.34, 0.65이었다. 정상인의 $R_v$$R_A$는 파킨슨 환자의 것보다 높았다. 즉, 정상인의 $k_3/k_4$는 파킨슨 환자의 것과 뚜렷이 구분되었다. 그리고 그래픽 분석방법과 면적비율 분석방법에 의한 $k_3/k_4$는 조직방사능비와 좋은 상관관계를 보여주었다. 결론 : 비침습성 단순화된 정량분석 방법들은 매개변수 $k_3/k_4$를 측정하는데 유용할 것이다. 그리고 특이결합비율 분석방법은 [I-123]IPT SPECT를 이용한 사람뇌의 도파민 운반체의 정량분석연구에 대해 유용하게 사용될 것이라고 생각된다.

  • PDF

수평관에서 R245fa의 응축 열전달계수 (Condensation Heat Transfer Coefficients of R245fa on a Plain Tube)

  • 심윤보;박기정;정동수;김종성
    • 설비공학논문집
    • /
    • 제19권8호
    • /
    • pp.555-562
    • /
    • 2007
  • In this study, condensation heat transfer coefficients (HTCs) of R22, R134a, R245fa and R123 are measured on a horizontal plain tube. All data are taken at the vapor temperature of $39^{\circ}C$ with a wall subcooling temperature $3-8^{\circ}C$. Test results show the HTCs of newly developed alternative low vapor pressure refrigerant, R245fa, on a plain tube are 9.5% higher than those of R123 while they are 3.3% and 5.6% lower than those of R134a and R22 respectively. Nusselt's prediction equation for a plain tube underpredicts the data by 13.7% for all refrigerants while a modified equation yielded 5.9% deviation against all data. From the view point of environmental safety and condensation heat transfer, R245fa is a long term good candidate to replace R123 used in centrifugal chillers.

Effect of Ultrasound-Induced Hyperthermia on Cellular Uptake of P-gp Substrate and Non-P-gp Substrate in MDR Cells

  • Cho, Cheong-Weon;Kim, Dong-Chool;Shin, Sang-Chul
    • Journal of Pharmaceutical Investigation
    • /
    • 제37권3호
    • /
    • pp.131-135
    • /
    • 2007
  • A previous report recently demonstrated that ultrasound-induced hyperthermia (USHT:0.4 watts (W)/$cm^2$ at $41^{\circ}C$) could increase cellular uptake of P-glycoprotein (P-gp) substrates in P-gp expressing cancer cell lines. Since P-gp plays a major role in limiting drug permeability in the multi-drug resistant (MDR) cells, studies were conducted to elucidate the mechanism of USHT on cellular accumulation of P-gp and non-P-gp substrate in MDR cells. To accomplish this aim, we studied the effects of USHT on the accumulation of P-gp substrate, R123 and non-P-gp substrate, antipyrine in MDR cells. We demonstrated that USHT increased permeability of hydrophobic molecules (R123 and $[^{14}C]$-antipyrine). The enhanced permeability is reversible and size-dependent as USHT produces a much larger effect on cellular accumulation of $[^{14}C]$-antipyrine (MW 188) than that of R123 (MW 380.8). These results suggest that USHT could affect MDR cells more sensitive than BBMECs. Also, the present results point to the potential use of USHT to increase cellular uptake of P-gp recognized substrates, mainly anti-cancer agents into cancer cells.