• 제목/요약/키워드: R-TOC

검색결과 93건 처리시간 0.021초

일반 유기물 항목과 분광특성을 이용한 한강수계 내 난분해성 물질 지표 제시 (Development of Estimation Indices for Refractory Organic Matter in the Han-River Basin using Organic Matter Parameters and Spectroscopic Characteristics)

  • 이보미;이태환;허진
    • 한국물환경학회지
    • /
    • 제27권5호
    • /
    • pp.625-633
    • /
    • 2011
  • A long-term water quality monitoring in the Han River Basin reveals a consistent increasing trend for the concentration of refractory organic matter (R-OM) in major monitoring sites of the watershed. Because the determination of R-OM concentrations typically requires a long time of microbial incubation, it is essential to present the estimation indices for R-OM for an efficient watershed management. In this study, a number of surface water samples were classified into three groups, each of which were collected from Lake Paldang, rivers at rain and non-rain events, respectively. The corresponding R-OM concentrations were correlated with biochemical oxygen demand (BOD), chemical oxygen demand (COD), and total organic carbon (TOC) concentrations as well as ultraviolet and fluorescence intensities of the filtered samples. Among the traditional organic matter parameters, TOC exhibited the highest correlation coefficient with the R-OM concentrations regardless of the types of the sample groups. The equations for conversing TOC into R-OM concentrations were finally suggested as $0.43{\times}TOC+1.12$, $0.44{\times}TOC+0.61$, $0.24{\times}TOC+1.28$ for river samples at rain and non-rain events, and lake samples, respectively. TOC-BOD(C), the values of the TOC concentrations subtracted by carbon-converted BOD concentrations, was a good index for estimating the absolute concentrations of R-OM. UV absorbance at 254 nm was well correlated with R-OM concentrations of river samples while fluorescence intensities at 350 nm showed an excellent relationship with R-OM concentration of the lake samples. Our results suggests that simple spectroscopic parameters could be applied for in-situ monitoring tool techniques in watersheds.

비강우시 한강수계 하천의 연간 난분해성 물질 유출특성 (Runoff Characteristics of Refractory Organic Matters from Han River Basin during Dry Days)

  • 허상회;임지열;길경익
    • 한국습지학회지
    • /
    • 제19권3호
    • /
    • pp.353-358
    • /
    • 2017
  • 2,600만 수도권 시민들의 식수원인 한강수계의 경우 수질관리를 위해 비점오염원에 대한 관리가 중요하며 특히 비점오염원이 주요 원인인 유기물질 및 난분해성 물질에 대한 조사가 필요하다. 이번 연구에서는 한강 수계의 주요 3개 하천(남한강, 북한강, 경안천)의 연간 비강우시 난분해성 유기물질을 포함한 유기물질의 유출특성을 연구하였다. 연구결과 유기물질 및 난분해성 물질의 경우 용존성 물질의 비율이 높았으며 전체 부하량중 여름철에 대부분의 부하량이 가장 많았다. 각 하천별 유기물질 및 난분해성 물질의 연간 부하량의 경우 유역면적에 비례하여 남한강, 북한강, 경안천 순서로 나타났다. 각 유역 면적 당 부하량 산정결과 TOC의 경우 경안천, 남한강, 북한강 순서로 나타났으며, R-TOC의 경우 비교적 일정한 유출특성을 보였다.

물환경에서의 유기물질 지표 특성 및 효율적 이용방안 -낙동강수계 호소수를 대상으로- (Characteristics and Effective Usage of Organic Indexes in Water Environments -Lakes in Nakdong River Basin-)

  • 강미아
    • 한국습지학회지
    • /
    • 제16권1호
    • /
    • pp.153-160
    • /
    • 2014
  • 호소의 유기물질 오염도를 정확하게 파악하고, 호소내 수질관리를 개선하기위해 총유기탄소(TOC) 환경기준이 설정되었다. 낙동강수계에 위치하고 있는 상수원수로 이용되는 4개 호소의 화학적산소요구량(COD)과 TOC의 상관성은 $R^2$=0.639로 매우 유의한 결과로 나타났다. 농업용수 2개 호소와 늪 1개소의 자료를 모두 이용한 COD와 TOC의 상관성은 $R^2$=0.774로 더 높아졌으나 이것은 검출된 농도범위의 증가에 의한 것으로 보인다. TOC에 의해 요구되는 COD의 수준에 관계없이 탄소산화율은 평균 62%에 해당하였으며, 호소에 따른 현저한 차이는 보이지 않았다($62{\pm}8%$). 이것은 연구대상으로 한 호소의 유기물질 성상이 유사함을 나타낸다. TOC 자료가 충분히 구축될 때까지 COD 자료를 현명하게 활용하여야 하고, 이를 위해서는 호소에 영향을 미치는 유역의 특성과 호소의 이용측면을 고려하여 호소의 유기물질 수준을 평가할 필요가 있다.

감천 유역의 TOC 농도 추정을 위한 회귀 모형 개발 및 평가 (Development and Evaluation of Regression Model for TOC Contentation Estimation in Gam Stream Watershed)

  • 정강영;안정민;이경락;김신;유재정;천세억;이인정
    • 한국환경과학회지
    • /
    • 제24권6호
    • /
    • pp.743-753
    • /
    • 2015
  • In this study, it is an object to develop a regression model for the estimation of TOC (total organic carbon) concentration using investigated data for three years from 2010 to 2012 in the Gam Stream unit watershed, and applied in 2009 to verify the applicability of the regression model. TOC and $COD_{Mn}$ (chemical oxygen demand) were appeared to be derived the highest correlation. TOC was significantly correlated with 5 variables including BOD (biological oxygen demand), discharge, SS (suspended solids), Chl-a (chlorophyll a) and TP (total phosphorus) of p<0.01. As a result of PCA (principal component analysis) and FA (factor analysis), COD, TOC, SS, discharge, BOD and TP have been classified as a first factor. TOCe concentration was estimated using the model developed as an independent variable $BOD_5$ and $COD_{Mn}$. R squared value between TOC and measurement TOC is 0.745 and 0.822, respectively. The independent variable were added step by step while removing lower importance variable. Based on the developed optimal model, R squared value between measurement value and estimation value for TOC was 0.852. It was found that multiple independent variables might be a better the estimation of TOC concentration using the regression model equation(in a given sites).

광학특성을 가진 수질변수를 활용한 하구 담수호 내 TOC 농도 추정 (Estimating TOC Concentrations Using an Optically-Active Water Quality Factors in Estuarine Reservoirs)

  • 김진욱;장원진;신재기;강의태;김진휘;박용은;김성준
    • 한국물환경학회지
    • /
    • 제37권6호
    • /
    • pp.531-538
    • /
    • 2021
  • In this study, the TOC in six estuarine reservoirs in the West Sea (Ganwol, Namyang, Daeho, Bunam, Sapkyo, and Asan) was estimated using optically-active water quality factors by the water environment monitoring network. First, specification data and land use maps of each estuarine reservoir were collected. Subsequently, water quality data from 2013 to 2020 were collected. The data comprised of 11 parameters: pH, dissolved oxygen, BOD, COD, suspended solids (SS), total nitrogen, total phosphorus, water temperature, electrical conductivity, total coliforms, and chlorophyll-a (Chl-a). The TOC in the estuarine reservoirs was 4.9~7.0 mg/L, with the highest TOC of 7.0 mg/L observed at the Namyang reservoir, which has a low shape coefficient and high drainage density. The correlation of TOC with water quality factors was also analyzed, and the correlation coefficients of Chl-a and SS were 0.28 and 0.19, respectively, while the correlation coefficients of these factors in the Namyang reservoir were 0.42 and 0.27, respectively. To improve the estimation of TOC using Chl-a and SS, the TOC was averaged in 5 mg/L units, and Chl-a and SS were averaged. Correlation analysis was then performed and the R2 of Chl-a-TOC was 0.73. The R2 of SS-TOC was 0.73 with a non-linear relationship. TOC had a significant non-linear relationship with Chl-a and SS. However, the relationship should be assessed in terms of the spatial and temporal variations to construct a reliable remote sensing system.

Fabrication and Evaluation of a Total Organic Carbon Analyzer Using Photocatalysis

  • Do Yeon Lee;Jeong Hee Shin;Jong-Hoo Paik
    • 센서학회지
    • /
    • 제32권3호
    • /
    • pp.140-146
    • /
    • 2023
  • Water quality is crucial for human health and the environment. Accurate measurement of the quantity of organic carbon in water is essential for water quality evaluation, identification of water pollution sources, and appropriate implementation of water treatment measures. Total organic carbon (TOC) analysis is an important tool for this purpose. Although other methods, such as chemical oxygen demand (COD) and biochemical oxygen demand (BOD) are also used to measure organic carbon in water, they have limitations that make TOC analysis a more favorable option in certain situations. For example, COD requires the use of toxic chemicals, and BOD is time-consuming and can produce inconsistent and unreliable results. In contrast, TOC analysis is rapid and reliable, providing accurate measurements of organic carbon content in water. However, common methods for TOC analysis can be complex and energy-intensive because of the use of high-temperature heaters for liquid-to-gas phase transitions and the use of acid, which present safety risks. This study focuses on a TOC analysis method using TiO2 photocatalysis, which has several advantages over conventional TOC analysis methods, including its low cost and easy maintenance. For TiO2, rutile and anatase powders are mixed with an inorganic binder and spray-coated onto a glass fiber substrate. The TiO2 powder and inorganic binder solutions are adjusted to optimize the photocatalytic reaction performance. The TiO2 photocatalysis method is a simple and low-power approach to TOC analysis, making it a promising alternative to commonly used TOC analysis methods. This study aims to contribute to the development of more efficient and cost-effective approaches for water quality analysis and management by exploring the effectiveness and reliability of the developed equipment.

미호천의 물 환경 탐구 - TOC를 중심으로 한 수질모니터링 - (Inquiry of Water Environment in Mihocheon (Stream) - Water Quality Monitoring focused on TOC -)

  • 류재홍;이두곤
    • 한국물환경학회지
    • /
    • 제23권5호
    • /
    • pp.731-739
    • /
    • 2007
  • In this study, water quality monitoring focused on TOC was performed at 5 points in Mihocheon (Stream) from January to December 2006. And 10 parameters (water temperature, pH, DO, EC, turbidity, SS, BOD, $PO_4-P$, TOC, TN) were monitored every month for one year. According to this study, TOC increased towards the lower stream (#4~#5). Correlation coefficients between TOC and DO, EC, turbidity, SS, BOD, $PO_4-P$, TN were -0.126, 0.351, 0.320, 0.286, 0.711, 0.525, 0.666. TOC was highly related to BOD. As a result of linear regression analysis, regression equation between BOD and TOC was BOD=0.58TOC+1.90 ($R^2=0.506$). In Mihocheon (Stream), BOD/TOC ratio decreased towards the lower stream. This results show decrease of ratio of biodegradable organic material to total organic pollutants towards the lower stream. This study is significant since it has revealed the potential value of TOC as organic material indicator for inquiry of water quality characteristics in the natural water system.

회귀식을 사용한 하수처리장 방류수 CODMn 농도의 총 유기탄소 및 난분해성 물질 농도 전환 (Conversion of CODMn into TOC and Refractory Organic Matter Concentrations for Treated Sewage using Regression Equations)

  • 이태환;이보미;허진;정명숙;강태구
    • 한국물환경학회지
    • /
    • 제26권6호
    • /
    • pp.969-975
    • /
    • 2010
  • Estimating the organic matter loadings from individual treated sewage has become important for establishment of effective management strategies to control refractory organic matter (R-OM) in watersheds. For this study, regression equations were constructed using treated sewage data to convert the chemical oxygen demand (COD) concentrations, which are mostly available from open database, into total organic carbon (TOC) and R-OM concentrations. Effluent samples were collected from five major sewage treatment plants (STPs) located upstream of the lake Paldang. Variations in the OM concentrations were not associated with either the location of the STP or the sampling season. The effluent investigated were characterized by higher ratio of R-OM with respect to biodegradable organic matter (B-OM) and higher presence of dissolved organic matters (DOM) versus particulate organic matter (POM). Compared to $COD_{Mn}$, $COD_{Cr}$ exhibited higher oxidation efficiencies and greater variations in the concentrations. The concentrations of $COD_{Mn}$ were positively correlated with dissolved organic carbon (DOC), total organic carbon (TOC), and R-OM concentrations. There was nearly no seasonal and annual variation in the regression equations between $COD_{Mn}$ and TOC or R-OM concentrations. The constructed regression equations for TOC and R-OM were $0.650({\pm}0.071){\times}COD_{Mn}+1.426({\pm}0.575)$ and $0.340({\pm}0.083){\times}COD_{Mn}+2.054({\pm}0.670)$, respectively. The established equations are expected to contribute to estimating OM loadings from the STPs into the lake Paldang and also to compensating for the deficiency of the data for effluent OM concentrations in STP.

유출량, 수질 농도 및 부하량의 상호관계를 이용한 자료보간 방법에 관한 연구 (Study on the Method for Data Interpolation using the Correlation among Runoff, Water Quality Concentration and Load)

  • 오창열;정우철;진영훈;박성천
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2007년도 학술발표회 논문집
    • /
    • pp.1474-1478
    • /
    • 2007
  • 수문 및 수질자료는 일정한 기준에 의한 관측치를 시계열 자료로 기록하거나 전송할 때 다양한 형태의 오차가 발생하게 되며 또한 수문 및 수질자료를 관측하는 측정기기의 고장과 유지관리 등의 어려움으로 다양한 형태의 결측 자료가 발생하고 있다. 이와 더불어 수문 및 수질자료는 시공간적 변동성이 크며 비선형성이 강한 특성을 갖고 있다. 이러한 수문 및 수질 자료를 이용하여 모형을 구축할 경우 다양한 형태의 잡음에 대한 검증 및 잡음저감이 필수적 요건이라 할 수 있다. 따라서 본 연구에서는 영산강 유역의 본류부를 대표하는 나주지점에 대한 유출량과 총유기탄소(TOC) 농도 및 TOC 부하량 예측모형을 개발하였으며, 이를 위한 방법으로는 잡음저감을 위하여 웨이블렛 변환과 인공신경망을 적용하였다. TOC 부하량 자료는 유출량과 TOC 자료간의 함수로서 표현이 가능함에 따라 유출량 및 TOC 자료가 결측되었을 경우 역함수에 의한 계산으로 결측 자료에 대한 보간이 가능하다. 따라서 본 연구의 주안점은 잠음 저감 및 인공신경망에 의해 최적화된 예측 모형이 결측된 유출량과 TOC 자료에 대한 역함수로 정도있는 유출량과 TOC 자료 생성 가능성을 검토하고자 한다. 본 연구의 적용 결과, 유출량 자료가 결측되었을 경우 TOC 및 TOC 부하량 예측으로 유출량 자료에 대한 간접추정 및 결측 자료에 대한 보간의 정도를 평가한 결과 $R^2$는 0.99 이상의 값을 보였다. 또한, TOC 자료가 결측되었을 경우 역시 $R^2$는 비교적 우수한 0.97 이상의 값을 보였다. 따라서 본 연구에서 개발한 유출량 및 TOC, TOC 부하량 예측모형의 개발은 정도있는 유출량 및 TOC 수질 자료의 생성이 가능할 것으로 기대된다.한 물순환 해석을 할 수 있는 기반을 확보 하였으며, 가용한 장 단기간의 관측자료와 물수지 분석 연산식의 추정치를 바탕으로 관측자료에 의한 물수지 분석을 수행하였다. 분석 결과로 산지 소하천 유역인 설마천 시험유역의 각 수문요소의 물이동간의 정량적인 값을 알 수가 있었으며, 앞으로 추가적이고 지속적인 수문모니터링이 운영되고 물순환 해석 모형에 의한 검증이 수행된다면 정량적인 물순환 관계를 규명할 수 있을 뿐만 아니라 이와 관련된 수문요소기술을 확보할 수 있을 것이다.절한 타협과 조정을 필요로 한다. 그러나 절제의 한계를 넘어선다고 생각되거나, 조정의 노력이 불가능하거나, 실패했을 때 폭력적인 행동으로 나타나게 된다. 리차즈(I.A Richards)는 분노와 공포는 일단 겉잡을 수 없는 경향이 있다고 하면서 오늘날 폭력에 대한 요구가 일상의 정서 생활에 있어, 억압을 통한, 빈곤함을 반영하고 있지 않은지 생각해봐야 할 것이라고 충고한다. 조성 가이드라인(안)을 제시하였다.EX>$\ulcorner$세종실록$\lrcorner$(世宗實錄) $\ulcorner$지리지$\lrcorner$(地理志)와의 비교를 해보면 상 중 하품의 통합 9개소가 삭제되어 있고, $\ulcorner$동국여지승람$\lrcorner$(東國與地勝覽) 에서는 자기소와 도기소의 위치가 완전히 삭제되어 있다. 이러한 현상은 첫째, 15세기 중엽 경제적 태평과 함께 백자의 수요 생산이 증가하자 군신의 변별(辨別)과 사치를 이유로 강력하게 규제하여 백자의 확대와 발전에 걸림돌이 되었다. 둘째, 동기(銅器)의 대체품으로 자기를 만들어 충당해야할 강제성 당위성 상실로 인한 자기수요 감

  • PDF

유기물오염도 지표를 이용한 하천수질영향평가 - 산업폐수의 방류수질을 기준으로 - (Impact Assessment of River Water Quality using Organic Pollutant Index - Industrial Waste Water -)

  • 조수현;강미아;추용엽;정교철;정동희;이준흥
    • 지질공학
    • /
    • 제16권4호
    • /
    • pp.373-379
    • /
    • 2006
  • 우리나라에서 하천에 유입되는 유기물부하의 많은 부분을 차지하는 산업폐수를 대상으로 유기물 오염지표간의 상관성을 조사하였다. 기존 사용되고 있던 COD와 BOD를 현재 많은 국가에서 도입하고 있는 TOC와의 관계를 규명하였다. 업종별 업체별로 그 상관계수에는 큰 차이가 있었으며, 최고의 상관계수는 음식료품 생산업체의 방류수 중에 함유된 COD/BOD/TOC와의 관계에서 나타났다. 각각의 상관계수는 COD/BOD: 0.997, COD/TOC : 0.969, BOD/TOC: 0.990이었다. 상관계수가 낮은 경우도 많았으며, 동일업종이라 하더라도 상관도에는 일관성이 없었다. 그러므로 수질기준 책정 또는 하천수질 모니터링 등에 기존의 유기물질지표의 대체지표로써 TOC를 사용하는 것은 불가능할 것으로 사료된다. 그러나 이들의 상관도가 높은 방류수의 관리에 있어서는 유용하게 사용될 수 있으므로 이들 유기물질 인자간의 상관성을 검토하여 개별적으로 사용하여야 할 것이다.