• 제목/요약/키워드: R-410a

검색결과 305건 처리시간 0.025초

HFC32/HFC125 혼합냉매의 히트펌프 성능 평가 (Performance of HFC32/HFC125 Mixtures for Heat Pumps)

  • 김욱진;강동규;이요한;정동수
    • 설비공학논문집
    • /
    • 제23권12호
    • /
    • pp.791-798
    • /
    • 2011
  • In this study, performance of R410A(50%R32/50%R125) and HFC32/HFC125 mixture is measured to examine the effect of composition shift of R410A used for various air-conditioners and heat pumps. The composition of HFC32/HFC125 mixture varies from the reference composition of R410A ${\pm}10%$ with 5% interval. Tests carried out in a heat pump bench tester at the evaporation and condensation temperatures of $7/45^{\circ}C$ and $-7/41^{\circ}C$ for summer and winter conditions, respectively. Test results show that both the coefficient of performance (COP) and compressor power of the HFC32/HFC125 mixture have the maximum difference of 2.0% as compared to those of R410A. Compressor discharge temperatures of HFC32/HFC125 mixture are increased up to $6.7^{\circ}C$ as compared to that of R410A. The amount of charge for HFC32/HFC125 mixture vary within 5.6% as compared to that of R410A. Overall, performance of R410A is not appreciably affected by the composition shift of ${\pm}10%$ of R32 under both air-conditioning and heat pumping conditions.

대체냉매 R-407C와 R-410A를 사용하는 냉동시스템의 오일농도 예측에 관한 연구 (A study on prediction of oil concentration in the R-407C and R-410A refrigeration system)

  • 이종문;김창년;박영무
    • 설비공학논문집
    • /
    • 제11권3호
    • /
    • pp.384-390
    • /
    • 1999
  • A vibrating U-Tube decimeter has been evaluated as a sensor for measuring the concentration of oil in the liquid line of a refrigeration system. Calibration and performance tests were conducted under simulated liquid-line conditions for R-407C/POE oil and R-410A/POE oil mixtures in oil concentration from 0 to 15 weight percent. Test temperatures ranged from 20 to 5$0^{\circ}C$. As a result of test, oil concentration correlations are presented in terms of specific gravity at each constant temperature. These equations enable to predict the oil concentration without any extraction of the mixture, and can be applied for R-407C/POE oil and R-410A/POE oil mixtures.

  • PDF

알루미늄 다채널 평판관내 R-22 및 R-410A 응축에 관한 연구 (R-22 and R-410A Condensation in Flat Aluminum Multi-Channel Tubes)

  • 정호종;김내현;윤백;김만회
    • 설비공학논문집
    • /
    • 제14권7호
    • /
    • pp.575-583
    • /
    • 2002
  • In this study, condensation heat transfer tests were conducted in flat aluminum multi-channel tubes using R-410A, and the results are compared with those of R-22. Two internal geometries were tested; one with a smooth inner surface and the other with micro-fins. Data are presented for the following range of variables; vapor quality (0.1~0.9), mass flux (200~600 kg/$m^2$s) and heat flux (5~15 ㎾/$m^2$). Results show that the effect of surface tension drainage on the fin surface is more pronounced for R-22 than R-410A. The smaller Weber number for R-22 may be responsible. For the smooth tube, the heat transfer coefficient of R-410A is slightly larger than that of R-22. For the micro-fin tube, however, the reverse is true. Possible reasoning is provided considering the physical properties of the refrigerants. For the smooth tube, a correlation of Akers et at. type predicts the data reasonably well. For the micro-fin tube, the Yang and Webb model was modified to correlate the present data.

R-410A/POE 오일 혼합물의 용해도 및 상용성 측정 (Measurement of solubility and miscibility of R-410A/POE oil mixture)

  • 송준석;김창년;박영무
    • 설비공학논문집
    • /
    • 제12권2호
    • /
    • pp.209-217
    • /
    • 2000
  • The solubility and miscibility measurement apparatus was developed and used to obtain data for refrigerant/oil mixture. The solubility and miscibility data for R-410A/68 ISO VG polyol ester (POE) oil mixture are obtained over the temperature range from -20 to $60^{circ}C\;with\;10^{\circ}C$ intervals and the oil concentration range from 0 to 90 wt%. Using the experimental data, an empirical model was developed to predict the solubility relations for R-410A/POE oil mixture at equilibrium. In the R-410A/Solest 68 oil mixture, the average root-mean-square deviation between measured data and calculated results from the empirical model is 3.4% and in the R-4104/EMKARATE RL 68H oil mixture, that is 2.86%. For R-410A/68 ISO VG POE oil mixture immiscibility was usually observed at the low oil concentrations(5~30 wt%) over the all experimental temperature range($-20~60^{circ}C$) and at the high oil concentrations(50~90 wt%) over the low experimental temperature range($-2O~0^{circ}C$).

  • PDF

응축기의 설계조건에서 R22, R407C, R410A의 압력강하 예측 및 실험 (Prediction and Experiment of Pressure Drop of R22, R407C and R410A on Design Conditions of Condenser)

  • 김창덕;박일환;이진호
    • 설비공학논문집
    • /
    • 제16권1호
    • /
    • pp.42-53
    • /
    • 2004
  • An experimental study on the refrigerant-side pressure drop of slit fin-tube heat exchanger has been carried out. A comparison was made between the predictions of previously proposed empirical correlations and experimental data for the pressure drop on design conditions of condenser in micro-fin tube for R22 and its alternatives, R407C (R32/125/134a, 23/25/52 wt.%) and R410A (R32/125, 50/50 wt.%). Experiments were carried out under the conditions of inlet refrigerant temperature of 6$0^{\circ}C$ and mass fluxes varying from 150 to 250 kg/$m^2$s for R22, R407C and R410A. The inlet air conditions are dry bulb temperature of 35$^{\circ}C$, relative humidity of 40% and air velocity varying from 0.68 to 1.43 m/s. Experiments show that pressure drop for R410A and R407C were 17.8∼20.2% and 5∼6.8% lower than those of R22 respectively for the degree of subcooling of 5$^{\circ}C$. For the mass fluxes of 200∼250 kg/$m^2$s, the deviation between the experimental and predicted values for the pressure drop was less than $\pm$20% for R22, R407C and R410A.

셀 앤 플레이트 열 교환기에서의 R-410A 증발열전달에 관한 실험적 연구 (Experimental Study on R-410A Evaporation Heat Transfer Characteristics in Shell and Plate Heat Exchanger)

  • 김인관;김영수;박재홍
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권1호
    • /
    • pp.49-59
    • /
    • 2005
  • The evaporation heat transfer experiments are conducted with the shell and plate heat exchanger (S&PHE) without oil in the refrigerant loop using R-410A. An experimental refrigerant loop has been established to measure the evaporation heat transfer coefficient h. of R-410A in a vertical S&PHE. Two vertical counter flow channels were formed in the S&PHE by three plates haying a corrugated trapezoid shape of a $45^{\circ}C$ chevron angle. UP flow of the boiling R-410A in one channel receives heat from the hot down flow of water in the other channel The effects of the refrigerant mass flux. average heat flux. refrigerant saturation temperature and vapor qualify are explored in detail. Similar to the case of a plate heat exchanger. even at a very low Reynolds number, the flow in the S&PHE remains turbulent. The Present data shows that the evaporation heat transfer coefficients of R-410A increased with the vapor qualify. The results indicate a rise in the refrigerant mass flux caused an increase in the h.. Raising the imposed wall heat flux is found to slightly improve h., while h, is found to be lower at a higher refrigerant saturation temperature. Based on the present data. empirical correlation of the evaporation heat transfer coefficient is proposed.

대체냉매 공기조화기용 로터리 압축기의 성능향상을 위한 최적 토출계에 관한 실험적 연구 (An Experimental Study on the High Performance Optimal Discharge System of a Rotary Compressor for an Air Conditioner using alternative Refrigerant R410a)

  • 윤영;정진택;민만기
    • 설비공학논문집
    • /
    • 제13권2호
    • /
    • pp.96-105
    • /
    • 2001
  • R410a which is one of HFC refrigerants is being considered to be a promising replacement for R22 widely used in domestic air conditioners. The rolling piston type rotary compressors for R410a have lower energy efficiency than those for R22 because of the high pressure difference between a suction chamber and a discharge chamber in the compression mechanism. in addition, the re-expansion gas loss of the rotary compressor for R410a which occurs a ta clearance volume in a discharge port becomes larger than that for R22 due to high density of R410a refrigerant. Therefore, Pressure-Volume analyses for various design parameters of a discharge system were carried out to improve efficiency of a R410a rotary compressor. The results such as performance dta, over-compression loss, and re-expansion loss were acquired by P-V analyses and analyzed quantitatively. As a conclusion, the optimal specifications of several design parameters of a discharge system were obtained by analyzing P-V diagrams.

  • PDF

냉매 R410A를 적용한 실내 열교환기 설계 (Design of an Indoor Heat Exchanger that Apply Refrigerant R410A)

  • 김범찬;박창석;차우호;김성수;강용태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.317-322
    • /
    • 2008
  • The objectives of this paper are to study the effects of thermal and geometric conditions on the performance of indoor heat exchanger with R410A for Gas Engine Driven Heat Pump (GHP) application and to find optimum design conditions of indoor heat exchanger by parametric analysis for the key parameters. In the air side, moisture out of the humid air condenses on the fin surface while the refrigerant (R410A) boils inside the smooth tube. Therefore this study uses Log Mean Enthalpy Difference (LMHD) method to analyze the heat transfer from the humid air to the refrigerant of R410A. The results show that fin pitch and longitudinal pitch have significant effect on the heat exchanger preformance. This study will provide the guideline for optimum design of indoor heat exchanger with R410A for GHP application.

  • PDF

R-410A를 적용한 판형 열교환기의 응축 성능에 관한 실험적 연구 (An Experimental Study of Condensation in Plate Heat Exchangers with R-410A)

  • 변재현;이규정
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.304-310
    • /
    • 2000
  • The experimental study has been conducted on heat transfer characteristics of the plate heat exchangers(PHE) by several researchers. However most of all were focused on a gasket-type plate heat exchanger. Therefore further studies are need for a brazed-type. In the present study, a brazed type plate heat exchanger was tested at a chevron angle of $70^{\circ},\;55^{\circ}$ and $45^{\circ}$ with R-22 and R-410A. Condensation temperatures were $24.5^{\circ}C$, and mass flux was ranged from 35 to $60kg/m^2s$. The inlet and exit conditions are in a superheated vapor and subcooled liquid, respectively. The heat transfer coefficient increased with the chevron angle. The heat transfer coefficient of R-22 was lamer than that of R-410A for all chevron angles.

  • PDF

세관을 사용한 응축기에서 R-22의 대체냉매인 R-410A의 응축 열전달 특성 (Condensation Heat Transfer Characteristics of R-410A as an Alternative R-22 in the Condenser with Small Diameter Tubes)

  • 손창효
    • 청정기술
    • /
    • 제13권2호
    • /
    • pp.151-158
    • /
    • 2007
  • 프레온계 냉매의 지구온난화와 오존층파괴 문제로 인해 대체냉매로서 R-410A가 주목을 받고 있다. 이러한 대체냉매를 세관에 적용시킬 경우 효율을 향상시킬 뿐만 아니라 지구환경에 미치는 영향을 감소시키고, 대기를 청정하게 만드는 기술 및 방안으로 각광 받고 있다. 따라서 본 연구에서는 R-22의 대체냉매로 각광받고 있는 R-410A의 세관응축기 내에서의 응축열전달 특성에 대해 실험적으로 고찰하고자 하였다. 실험장치는 유동양식, 열전달, 압력강하 특성을 파악할 수 있도록 제작되었고, 주요 구성품은 냉매펌프, 증발기, 응축기(시험부), 사이트 글라스(가시화부), 압력탭, 측정장치 등이다. 시험부의 내관은 내경 3.36 mm와 5.35 mm인 수평평활 동관이다. 실험변수들의 범위로서 질량유속 $200{\sim}500\;kg/m^2s$이고, 열유속은 $1.0{\sim}2.4\;kW$이다. R-410A의 응축열전달 계수가 R-22에 비해 최대 5% 정도 높은 것을 알 수 있었다. 세관 내 R-410A와 R-22의 유동양식은 환상류 영역이 지배적으로 나타남을 관찰하였고, 건도가 0.2 이하인 영역에서는 성층류가 나타남을 확인할 수 있었다. 내경 3.36 mm의 압력강하가 내경 5.35 mm에 비해 $30{\sim}50%$정도 높았다. 종래의 응축 열전달 상관식과 실험데이터를 비교한 결과, Fujii의 상관식과 최대 40%이내에서 일치하였다.

  • PDF