• Title/Summary/Keyword: R&D monitoring

Search Result 589, Processing Time 0.026 seconds

R&D Monitoring and Novel Technology Exploration Concerning Research Area about Fire in High-rise Building (고층 건물 화재 관련 R&D 위상 분석 및 신기술 탐색 연구)

  • Shim, We;Choi, Jaekyung;Chung, Hyunsang;Heo, Yoseob;Seo, Seongho
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.2_2
    • /
    • pp.271-280
    • /
    • 2020
  • Due to the development of the urban economy, high-density buildings and skyscrapers have continued to increase in order to alleviate high population densities and to make efficient use of urban space. However, a fire in a high-rise building is a disaster that can lead to massive casualties and property damage because of the difficulty of firefighting and escaping. Various studies have been conducted on these high-rise buildings because they are sympathetic to these difficulties all over the world. In this paper, trends of researches and technologies related to fire in high-rise buildings are analyzed synthetically through thesis and patent data. In other words, we explored the trends of various studies that have been carried out so far through the thesis, and performed technical monitoring on actual implemented technology and newly implemented technologies through patent data. Through this research, we have studied the present and the future of technology for high-rise building fire.

A Power Quality Monitoring System(PQMS) : A Standard of User-Friendly-GUI & Analysis Graphic Representation (전력품질 모니터링 시스템 : User-Friendly-GUI 및 분석 그래프 표준)

  • Kim, Young-Il;Han, Jin-Hee;Yoon, Tai-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.127-130
    • /
    • 2002
  • Recently, with the increasing use of power semiconductors and microprocessors which are very sensitive to little change of power quality and for coping positively with anticipating power quality disputes between power providers and consumers which are possible to occur by of power market being formed, the power quality problem has gained preponderance among the contemporary research areas. To serve these purposes, the integrated system has been researched and developed for power quality analysis and monitoring, which provides speedy and powerful functions by the growth of computer hardware and information technology. But the advent of fast and lower price hardware make little difference in an application on many systems. As a result, the key issues of constructing power quality monitoring system are in the management of data obtained, accurate algorithms, graphic representation and user-friendly-environment for easy and clear analysis results. So, in this paper it will be introduced that the standard of user-friendly-GUI(Graphic User Interface) and analysis graphic representation for intuitive understanding of results from power quality analysis based on consideration of several systems currently being in use.

  • PDF

Effective Characterization Methods of Polycrystalline Silicon Films Fabricated by Ni Induced Crystallization

  • Koo, Hyun-Woo;Maidanchuk, Ivan;Jung, Jae-Wan;Lee, Ki-Yong;Berkeley, Brian H.;Kim, Sang-Soo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.250-253
    • /
    • 2009
  • Effective methods for monitoring the quality of polycrystalline silicon (poly-Si) films are discussed. Raman spectroscopy is typically used to determine crystallinity of poly-Si, but this method has limitations for data gathering on large substrates for mass production of poly-Si TFT backplanes. Spectroscopic ellipsometry is proposed as an alternative for fast and simple estimation of poly-Si quality on large substrates. By using both ellipsometry and Raman spectroscopy, it is possible to determine whether the quality and uniformity of the poly-Si films meet the criteria required for mass production of TFT backplanes for AMOLED panels.

  • PDF

A Study on the Efficiency Analysis of R&D General Management Cost for Domestic R&D Agency Institutes (국내 R&D 전문관리기관의 R&D 기획·평가·관리비의 효율성 분석에 관한 연구)

  • Song, Gwangsuk;Yoo, Hanjoo;Kim, Kyung-Won;Jang, Hyun-Duk
    • Journal of Korean Society for Quality Management
    • /
    • v.43 no.1
    • /
    • pp.85-102
    • /
    • 2015
  • Purpose: This study is aimed to develope effective guidelines of R&D institute with regard to general management cost, by analyzing the management characteristics of 14 domestic R&D institutes general management costs. Methods: The bootstrapping method is applied to obtain the average general management cost of 14 R&D institute and the effective R&D institutes are presented by comparing the general management costs of R&D and the rate of inflation. Results: The results show that the average R&D general management cost of 14 R&D institutes is 3.32% and, in general, it turns out that the R&D general management costs do not reflect the inflation rate after a comparative analysis of the variation of the R&D general management costs. In addition, the results of cost-effective analysis show that only 5 R&D institutes are efficient in R&D activities. Conclusion: Applying a uniform standard of R&D general management costs although their management characteristics are different, can cause the impediment to the independence and transparency of R&D institutes. Therefore it is recommended a strict implementation with respect to the monitoring system of each R&D institute and the budget policy methods which are reflected management characteristics.

Development and Performance Test of In-situ Particle Monitoring System using Ion-counter in Vacuum Environments (진공 환경내 실시간 입자 모니터링 시스템의 개발 및 성능평가)

  • Ahn Kang-Ho;Kim Yong-Min;Kwon Yong-Taek
    • Journal of the Semiconductor & Display Technology
    • /
    • v.5 no.1 s.14
    • /
    • pp.45-49
    • /
    • 2006
  • In this paper, a new method that monitors the quantity of particles using ion-counter in vacuum environment is introduced. In-situ particle monitoring (ISPM) system is composed by Gerdien type ion-counter (house-made), DC power supply and electrometer. The ion-counter applied by positive voltage detects only positive charged particles. Therefore the particles to be detected should be in known charge state for further data analysis. ion-counter is installed at the exhaust line of process equipment where the pressure loss is structurally low. ISPM system performance has been verified with SMPS (Scanning Mobility Particle Sizer) system. The correlation coefficient is above 0.98 at the particle size range of $20{\sim}300nm$ in diameter with identified charge distribution under $0.1{\sim}10.0$ Torr.

  • PDF

RECENT R&D ACTIVITIES ON STRUCTURAL HEALTH MONITORING FOR CIVIL INFRA-STRUCTURES IN KOREA

  • Yun, Chung-Bang
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.21-32
    • /
    • 2003
  • Developments and applications of the structural health monitoring (SHM) systems have become active particularity for long-span bridges in Korea. They are composed of sensors, data acquisition system, data transmission system, information processing, damage assessment, and information management. In this paper, current status of research and application activities on SHM systems for civil infra-structures in Korea are briefly introduced by 4 parts: (1) current status of bridge monitoring systems on existing and newly constructed bridges, (2) research and development activities on smart sensors such as optical fiber sensors and piezo-electric sensors, (3) structural damage detection methods using measured data, and (4) a test road project for pavement design verification and enhancement by the Korea Highway Corporation. Finally the R&D activities of a new engineering research center entitled Smart Infra-Structure Technology Center at Korea Advanced Institute of Science and Technology are also briefly described.

  • PDF

Monitoring of Clinical Trials: Issues and Recammendations

  • Fleming Thomas R.;Demets David L.
    • 대한예방의학회:학술대회논문집
    • /
    • 1994.02b
    • /
    • pp.270-284
    • /
    • 1994
  • Interim analyses of randomized trials enable investigators to make more efficient use of limited research resources and to satisfy ethical requirements that a regimen be discontinued as soon as it has been established to have an inferior efficacy/toxicity profile. Unfortunately. the integrity and credibility of these trials can be compromised if inappropriate procedures are used in monitoring interim data. 'In this paper we discuss how group sequential designs provide useful guidelines that enable one to satisfy the valid objectives of interim monitoring while avoiding undesirable consequences, and we consider how flexible one can be in the way such designs are implemented. We also provide motivation for the role of data-monitoring committees in preserving study integrity and credibility in either government- or industry-sponsored trials. In our view. these committees should have multidisciplinary representation and membership limited to individuals free of apparent significant conflict of interest, and ideally should be the only individuals to whom the data analysis center provides interim results on relative efficacy of treatment regimens. Finally. we discuss some important practical issues such as estimation following group sequential testing, anal ysis of secondary outcomes after using a group sequential design applied to a primary outcome, early stopping of negative trials. and the role of administrative analyses.

  • PDF

Study on real time monitoring to detect third party damage using vibration signal (진동신호를 이용한 타공사 조기 감시 기술 연구( I ))

  • Cho S.H.;Jeon K.S.;Park K.W.;Cho Y.B.;Li S.Y.;Kyo Y.T.
    • Journal of the Korean Institute of Gas
    • /
    • v.4 no.1 s.9
    • /
    • pp.1-8
    • /
    • 2000
  • Third party damage is one of the causes intrimiting the safety of a buried pipelines and it is very important to detect third party damage on pipelines as soon as possible. The purpose of this study is whether third-party damage can be detected by accelerometer sensor and how far the third-party damage signal can propagate. And a pilot experiment was carried out in order to find third-party damage location. As a result, the detected signal's spectum is high frequency at short distances, as the distance is far, the signals in high frequency range are attenuated and those in low frequency range remain. It was also proved that third-party damage within 5.3km distance can be detected by monitoring vibration signals.

  • PDF

Web-based GIS partial discharge monitoring system development (Web기반 GIS 부분방전 진단 시스템 개발)

  • Kim, Hong-Seok;Hong, Jung-Ki;Choi, Dae-Hee;Lee, Hahk-Sung;Oh, Jae-Hun
    • Proceedings of the KIEE Conference
    • /
    • 2007.11b
    • /
    • pp.217-219
    • /
    • 2007
  • GIS 부분방전 진단 시스템은 가스 절연개폐장치(GIS: Gas Insulated Switchgear) 내부에서 발생하는 UHF 대역의 부분방전 신호를 측정하며 이상신호가 발생하면 위상에 대한 부분방전 패턴을 분석하고 원인을 진단한다. 이러한 GIS 부분방전 진단 시스템은 다수의 변전소에 설치되어 운전되며 중앙제어센터에서 통합하여 관리하고자 할 경우 네트워크와 데이터베이스에 병목현상이 발생한다. 이에 본 논문에서는 Web을 통한 시스템의 분산화와 정보의 구분을 통한 정보의 분류로 병목현상을 줄이는 Web기반 GIS 부분방전 진단 시스템의 개발에 대하여 기술하고자 한다.

  • PDF