• Title/Summary/Keyword: Quick

Search Result 2,950, Processing Time 0.029 seconds

A COMPARISON OF THE APICAL SEAL PRODUCED BY EASY FILLING SYSTEM AND QUICK OBTURATION SYSTEM (Easy Filling 및 Quick Obturation System을 이용한 열연화 충전법의 치근단 밀폐도 평가)

  • Shin, Jung-In;Kum, Kee-Yeon;Lee, Sung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.2
    • /
    • pp.202-211
    • /
    • 2000
  • The aim of this study was to compare the apical sealing ability of a new thermoplasticized gutta-percha filling technique, the Easy Filling and the Quick Obturation system with lateral condensation technique and Thermafil system to evaluate their clinical acceptabilities. Fifty-two extracted single-rooted teeth were instrumented to #35 using the .04 taper ProFile system. Four groups of 12 teeth were obturated by lateral condensation technique. Thermafil system and two new thermoplasticized gutta-percha techniques, the Easy Filling system and Quick Obturation system (Meta Dental co. Ltd. Korea), respectively. Four teeth served as controls. After the teeth were immersed in 2% methylene blue dye for 48 hours, they were resected horizontally at 1mm to 5mm level from the anatomical apex using a low-speed microtome. Each section was examined under a stereomicroscope at ${\times40}$ magnification and photographed. After each image was scanned, the leakage area was measured at each level using Brain 3 (Nosdia Tech., Korea) software. Leakage ratio was calculated for each group and was analyzed statistically to come up with the following results: 1. At 1mm level, the Quick Obturation system had the largest amount of apical leakage and it was statistically significant when compared with the lateral condensation group and the Thermafil group (p<0.05). 2. At 2mm and 3mm level, there were no significant difference of apical leakage among all four groups (p>0.05), and from 4mm level, no apical dye penetration was observed in all the groups. In conclusion, the apical seal produced by Easy Filling system and the Quick Obturation system was comparable to lateral condensation technique and Thermafil system except for the 1mm level. More improvement of the apical seal can be expected as the operator becomes skillful with the new techniques.

  • PDF

Optimal Design of A Quick-Acting Hydraulic Fuse Using Design of Experiments and Complex Method (실험계획법과 콤플렉스법에 의한 고성능 유압휴즈의 최적 설계)

  • Lee, Seong Rae
    • Journal of Drive and Control
    • /
    • v.12 no.4
    • /
    • pp.8-14
    • /
    • 2015
  • A quick-acting hydraulic fuse, which is mainly composed of a poppet, a seat, and a spring, must be designed to minimize the leaked oil volume during fuse operation on a line rupture. The optimal design parameters of a quick-acting hydraulic fuse were searched using the design of experiments method and the complex method. First, the $L_{50}(5^4)$ orthogonal array is used to find the robust minimum point among the 625 points of design variables. The search range can then be narrowed around the robust minimum point. Second, the $L_{25}(5^4)$ orthogonal array is used to obtain the variations of the design variables in the narrowed search range. The variations of design variables are used to set the structure of a polynomial equation representing the leakage oil volume of the quick-acting hydraulic fuse. The least squares method is then applied to obtain the coefficients of polynomial equation. Finally, the complex method is used to find the optimal design parameters where the objective function is described by the polynomial equation.

More on Quick Analysis of Unreplicated Factorial Designs Avoiding Shrinkage and Inflation Deficiencies

  • Aboukalam, F.
    • International Journal of Reliability and Applications
    • /
    • v.7 no.2
    • /
    • pp.167-175
    • /
    • 2006
  • Effective and quick methods that are easy to carry out even by hand, or easy to be programmed by hand-held calculators are needed for assessing the sizes of contrasts of unreplicated $2^P$ factorial designs. Moreover, they have the advantage to use the original numerical measurements which makes the analysis easier to explain. Basically, Lenth (1989) is one of the most familiar of such quick and powerful methods. Later on, Aboukalam (2001) proposes under constant effects an alternative sophisticated method to Lenth's method. The proposed method is the supreme from two considerable powers. The first utmost indicates less inflation deficiency while the other utmost indicates less shrinkage deficiency. Also under constant effects, Al-Shiha (2006) introduces an alternative quick method which is less shrinkage deficiency while the inflation deficiency is the same. If effects are random, Aboukalam (2005) introduces an alternative quick method in which the first power is favored as long as the second power is within a small margin. In the spirit of quickness and fixed effects, this article adds another method which is supreme from the two considerable powers. The method is based on a one step of the scale-part of a suggested M-estimate for location. Explicitly, we suggest adapting the skipped median (ASKM) estimate. Critical values of ASKM-method, for several sample sizes often used, are empirically computed.

  • PDF

A Study on the Optimal Design According to the Piston Shape of the 3/8 Hydraulic Quick Coupler (3/8" 유압 퀵 커플러의 피스톤형상을 고려한 최적설계에 관한 연구)

  • Kim, Nam-Yong;Wu, Yu-Ting;Qin, Zhen;Cho, Yong-Min;Lyu, Sung-Ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.2
    • /
    • pp.66-71
    • /
    • 2021
  • A hydraulic quick coupler is a component used to easily connect or disconnect pipes or hoses that transfer high pressure fluid without leakage in various mechanical devices. In this study, to obtain an optimal design of a 3/8" hydraulic quick coupler, the effect of different shapes of the internal piston on the internal flow characteristics of the coupler was analyzed and evaluated through numerical analysis based on computational fluid dynamics. Subsequently, the optimal shape design of the internal piston was obtained by comparing the flow characteristics results such as velocity distribution, temperature distribution, and the pressure drop of the hydraulic quick coupler.

Response Time Index and Suppression Capability of Standard and Quick Response Sprinkler Head (표준형 및 속동형 스프링클러헤드의 반응시간지수와 소화성능)

  • 정길순;이병곤
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.4
    • /
    • pp.59-70
    • /
    • 1998
  • In this study, response time index(RTI) of standard and quick response type sprinkler head are measured and compared through ramp and plunge test in heated wind tunnel. Also discharge rate and water distribution, actual delivered density(ADD), fire test with wood cribs are performed to compare the fire suppression capability and the operation time and temperature between standard and quick response type sprinkler head.

  • PDF

The Study of Properties for Quick Cement Mortar Grouts (초속경성 시멘트 모르타르 그라우트재 특성에 관한 연구)

  • 정밀철
    • Journal of the Korean Ceramic Society
    • /
    • v.34 no.5
    • /
    • pp.449-452
    • /
    • 1997
  • Quick hardened property and compressive strength experimented to the C4A3 quantities. Workability experimented to the hydration behavior as retarder added to the C4A3. Compressive strength reached {{{{ delta }}3h=300~350 kgf/$\textrm{cm}^2$, {{{{ delta }}6h=400~450 kgf/$\textrm{cm}^2$, {{{{ delta }}24h=500~550 kgf/$\textrm{cm}^2$. Flow loss rate reached 70.1% to retarder addition 0.12% after 15 min. Test items were SEM, XRD, TG-DTA, MCC, porosity and zeta potential.

  • PDF

Comparison of Ionosphere Models for Single Frequency GNSS Receiver (단일주파수 GNSS 수신기를 위한 전리층 모델 비교)

  • Lee, Chang-Moon;Park, Kwan-Dong
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2010.04a
    • /
    • pp.147-150
    • /
    • 2010
  • Ionopheric deley is the largest error sources in GNSS positining. The single frequency receiver user needs an ionospheric model like the Klobuchar model or NeQuick model to eliminate the ionospheric error. In this study we estimated VTEC(Vertical Total Electron Content) over DAEJ station using the two models in each season. We compared the results with Global Ionosphere Maps and International Reference Ionosphere model predictions. As a result, the NeQuick model was more accurate than Klobuchar model.

  • PDF

Foreshore Resources Survey of Shanghai in QuickBird Image

  • Xingnan, ZHANG;Fei, NI;Shuangquan, XU;Longhua, GAO
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.1281-1283
    • /
    • 2003
  • By use of RS and GIS, the QuickBird image and geographic map were used for the survey of the foreshore resources of Shanghai. The image was processed and interpreted. The distribution maps of sea dike, foreshore, vegetation, soil, hydraulic structures, landscape, topography, and so on were extracted in manual classification. These data have been integrated into the information management system for the shoreline and foreshore. It plays an important role in the evolvement analysis of the shoreline and foreshore.

  • PDF

A Study on Production of Digital Map Using QuickBird Imagery (QuickBird 영상을 이용한 수치지도 제작에 관한 연구)

  • Kang, Joon-Mook;Yoon, Hee-Cheon;Lee, Yong-Woong;Kim, Youn-Gwan;Youn, Kyung-Chul
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2007.04a
    • /
    • pp.357-360
    • /
    • 2007
  • Efficient extraction and update of imagery is a crucial element in establishing latest geospatial information in today's fast changing Information society. Provision of Quick Bird imagery, with 61cm resolution panchromatic imagery and 2.5m resolution multi-chromatic imagery is contributing greatly in the application field if high density geospatial information. This research have conducted digital plotting utilizing stereo images provided by QuickBird satellite and evaluated the accuracy through comparison and analysis with digital map results. It turned out that result has smaller error than standard deviation of scale of 1:5,000 set by the NGII. This proves that the production of digital map at scale of 1:5,000 is possible.

  • PDF