• Title/Summary/Keyword: Quantitative parameters

Search Result 1,116, Processing Time 0.035 seconds

Evaluation of the Influence Factor on the Settlement of Composition Ground (복합지반의 침하에 대한 영향인자의 평가)

  • Kim, Bangsik;Bae, Wooseok
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.3
    • /
    • pp.19-25
    • /
    • 2007
  • Stone columns is the ground improvement method which composed of compacted gravel or crushed stone inserted into the soft ground consisting of loose sand and clay. There are many difficulties in quantitative analysis of soil-pile interaction because settlement behavior of stone columns is affected by various parameters. In this study, various parameters of behavior of end-bearing group piles are investigated by load tests. Finally, the improved characteristics of soft ground and the influence of design parameters are investigated in this study using PR (performance ratio) value. From the PR value calculation and test results, we know that settlement behavior of stone columns is affected by area replacement ratio of composite ground, diameter of column rather than embedment ratio and mat.

  • PDF

Evaluation on the Improvement of Equilibrium Sense Using a Virtual Bicycle System (가상 자전거 시스템을 이용한 평형감각 증진의 평가)

  • Jeong S.H.;Piao Y.J.;Jeon Y.Y.;Lee S.M.;Kwon T.K.;Hong C.U.;Kim N.G.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1954-1957
    • /
    • 2005
  • A quantitative evaluation of postural balance training using a virtual reality bicycle system was performed. In the experiment, the effectiveness of virtual reality bicycle system on postural balance training was analyzed with four male subjects in their twenties. The parameters measured during cycling were cycling time, average velocity, number of times subject deviated from path, and weight shift. Those parameters were evaluated for the quantification of the extent of control. We also measured the parameters on postural control capability after 5th trial and 10th trial in a balance testing system with a force plate to find out the effectiveness of the training. In the balance test with force plate, it was found out that the weight shift was almost zero and the deviation from the target trace reduced significantly after the training with the virtual cycle. The result showed that the virtual bicycle system was an effective system as a rehabilitation training device.

  • PDF

Usage of Multiple Regression Analysis in Prediction System of Process Parameters for Arc Robot Welding (아크로봇 용접 공정변수 예측시스템에 다중회귀 분석법의 사용)

  • Lee, Jeong-Ick
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.4
    • /
    • pp.871-877
    • /
    • 2008
  • It is important to investigate the relationship between weld process parameters and weld bead geometry for adaptive arc robot welding. Howeve, it is difficult to predict an exact back-bead owing to gap in process of butt welding. In this paper, the quantitative prediction system to specify the relationship external weld conditions and weld bead geometry was developed to get suitable back-bead in butt welding which is widely applied on industrial field. Multiple regression analysis for the prediction of process parameters was used as the research method. And, the results of the prediction method were compared and analyzed.

Comparative Study of Pre and Postoperative Voice and Image Analysis in Unilateral Vocal Cord Paralysis and Vocal Polyp (편측 성대마비와 성대폴립 환자의 수술 전후 음성검사와 이미지 화상분석의 상관관계에 대한 객관적 비교연구)

  • 김시찬;정유삼;홍정표;오정석;최홍식
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.11 no.1
    • /
    • pp.20-27
    • /
    • 2000
  • To determine what is the change of pre and postoperative voice and image analysis parameters and correlations between them, videostroboscopy was analyzed in each 18 patients with unilateral vocal cord paralyses or vocal polyps before and after the surgery from November, 1996 to April, 1999. The correlation between acoustic and aerodynamic parameters was investigated. The software-Videolink and $\pi$-View(Mediface Co, Seoul, Korea)-was used in a quantitative analysis. In unilateral vocal cord paralysis, the glottic angle is well correlated with maximum phonation time, jitter and shimmer preoperatively. The postoperative glottic angle is also correlated with preoperative maximum phonation time. In patients with the vocal polyp, the chink is postoperatively decreased, but the size of the chink and the polyp is not correlated with pre and postoperative voice analysis parameters. These findings reveal that glottic an and vocal fold angle are good indicators of e postoperative glottic configuration in unilateral vocal cord paralysis. Vocal fold ratio is also a useful indicator that represents the length of vocal folds. We consider that the computerized analysis through videostroboscopy is one of objective diagnostic methods in many voice disorders if we can measure a distance between the telelaryngoscope and vocal folds.

  • PDF

Quantitative Analysis of Effect of Shrink Fit in Cold Forging (냉간단조에서 금형 열박음 영향의 정량적 분석)

  • Li, Qiushi;Kim, Min-Cheol;Jung, Dong-Chan;Son, Yo-Hun;Joun, Man-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.3
    • /
    • pp.301-307
    • /
    • 2011
  • In this paper, effects of major design parameters of cold forging dies on die mechanics are quantitatively investigated with emphasis on shrink fit using a thermoelastic finite element method. A ball-stud cold forging process found in a cold forging company is selected as a test process and the effects of die insert material, magnitude of shrink fit, dimension of shrink ring, number of shrink rings, partition of die insert and clamping force on effective stress and circumferential stress are analyzed. It has shown that the number of shrink rings, magnitude of shrink fit, and Young's modulus of die insert material have strong influence on compressive circumferential stress in die insert but that the influence of the other design parameters is relatively weak.

Design of Haptic Chair based on Haptic-Aided Design Capable of Design Parameter Adjustment (햅틱보조설계 기반의 설계변수 조절이 가능한 햅틱의자의 설계)

  • Huh, Seok-Haeng;Jin, Yong-Jie;Song, Jae-Bok
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.860-864
    • /
    • 2008
  • In modern society, people tend to spend their time on various types of chairs. However, it is not easy for a designer to design a comfortable chair, because satisfaction with the chair depends not only on the quantitative elements such as size, but also on the qualitative element such as the user's feeling. To deal with these problems, there have been many studies on designing an ergonomics chair. In this paper, the hapticaided design (HAD) system was adopted to design the ergonomics chair. Based on the HAD system, the designer can experience whether the chair is comfortable or not through the haptic device, and also can modify the design parameters instantaneously. The haptic chair capable of controlling the design parameters in real time was proposed as a haptic simulator. The controllable parameters such as the seat height, reclining angle, stiffness of the backrest, and so on were selected based on the previous researches related to ergonomics chairs. It will reduce the development cost and time by replacing the process of making the real mock-up and prototype with the haptic chair.

  • PDF

Haptic-Aided Design Using a Haptic Chair Capable of Adjustable Backrest (등판 조절이 가능한 햅틱의자를 이용한 햅틱 보조 설계)

  • Huh, Seok-Haeng;Lee, Sang-Duck;Song, Jae-Bok
    • The Journal of Korea Robotics Society
    • /
    • v.4 no.3
    • /
    • pp.243-249
    • /
    • 2009
  • In modern society, people spend most of their time on various types of chairs. However, it is not easy for a designer to design a comfortable chair because satisfaction with the chair depends not only on the quantitative elements such as size, but also on the qualitative element such as the user's feeling. To deal with these problems, there have been many studies on designing ergonomic chairs. This paper proposes the haptic-aided design (HAD) system to design an ergonomic chair. Based on the HAD system, the designer can experience whether the chair is comfortable or not through the haptic device, and also can modify the design parameters instantaneously. The haptic chair capable of controlling the design parameters in real time was proposed as a haptic simulator. The controllable parameters, such as seat height, reclining angle, stiffness of the backrest, and so on were selected based on the previous research related to ergonomic chairs. The proposed methodology will help reduce the development cost and time by replacing the process of making the real mock-ups and prototypes with the haptic chair.

  • PDF

A Study on Recognition of Operating Condition for Hydraulic Driving Members

  • Park, Heung-Sik;Kim, Young-Hee;Kim, Dong-Ho;Cho, Yon-Sang;Park, Jae-Sang
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.4 no.6
    • /
    • pp.44-49
    • /
    • 2003
  • The morphological analysis of wear debris can provide early a failure diagnosis in lubricated moving system. It can be effective to analyze operating conditions of oil-lubricated tribological system with shape characteristics of wear debris in a lubricant. But, in order to predict and recognize an operating condition of lubricated machine, it is needed to analyze and to identify shape characteristics of wear debris. Therefore, If the morphological characteristics of wear debris are recognized by computer image analysis using the neural network algorithm, it is possible to recognize operating condition of hydraulic driving members. In this study, wear debris in the lubricating oil are extracted by membrane filter (0.45$\mu\textrm{m}$), and the quantitative values of shape parameters of wear debris are calculated by the digital image processing. This shape parameters are studied and identified by the artificial neural network algorithm. The result of study could be applied to prediction and to recognition of the operating condition of hydraulic driving members in lubricated machine systems.

Engineering Geological Characteristics of Sedimentary Rocks at Ulsan Area (울산지역 퇴적암류의 지질공학적 특성)

  • Kim, Kwang-Sik;Kim, Kwang-Yeom;Seo, Yong-Seok;Kim, Chang-Yong
    • The Journal of Engineering Geology
    • /
    • v.17 no.4
    • /
    • pp.535-544
    • /
    • 2007
  • Discontinuities developed in a sedimentary rock mass are the most important factor to determine mechanical properties of the rock mass. Parameters described discontinuities in rock mass generally connote heterogeneity and uncertainty. In this study, probabilistic statistics method was used to determine parameters of discontinuities quantitatively and objectively. The field survey was conducted at 33 sedimentary rock slopes in Ulsan area, according to the suggested methods for the quantitative description of discontinuities in rock mass(ISRM, 1978). The engineering geological characteristics of the sedimentary rocks at Ulsan area was determined as probability distribution function deduced by analyzing parameters of discontinuities.

A Quantitative Analysis of Activation Pattern of Active Elbow Muscles (주관절 근육의 활성화 유형에 대한 정량적 분석)

  • Lee, Du-Hyoung;Lee, Young-Seock;Lee, Jin;Kim, Sung-Hwan
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.4
    • /
    • pp.413-420
    • /
    • 1997
  • In this paper, we analyzed the contraction patterns of active elbow muscles during isometric, concentric and eccentric contraction. The analysis parameters consist of frequency domain parameters (mean frequency, median frequency, peak frequency, peak power, skewness, kurtosis) and time domain paraseters (zero crossing, positive maxima, integrated EMG). The results of this study were as follows; The BR/BB of isometric contraction appeared to be Venter as the elbow joint was more extended. The BR /BB during concentric and eccentric contraction tended to increase with more extension of the elbow joint angle, but there was no significant difference between concentric and eccentric contraction. Further, the EMG power spectrum due to the type of contraction were different betwen eccentric and concentric contraction. According to the results, it was found that the activation pattern in elbow flexor muscles was different during three different muscle contraction pattern. Therefore, elbow flexor muscles should not be considered a single functioning unit. Especially, at the time domain analysis, IEMG is a dominant parameter for analysis of activation patterns, and the skewness kurtosis can be useful parameters in functional recognition for prosthesis control purpose.

  • PDF