• 제목/요약/키워드: Quantitative Performance Assessment

검색결과 244건 처리시간 0.024초

Development of ANSP Safety Maturity Survey Model for Enhancement of Air Traffic Service (항행 서비스 향상을 위한 항행시설 안전성숙도 평가 모델 개발)

  • Park, Dam-yong
    • Journal of Advanced Navigation Technology
    • /
    • 제20권2호
    • /
    • pp.141-147
    • /
    • 2016
  • Stable and reliable air traffic service is required for users (aircraft pilot, air traffic controller, airlines and public) through enhancing capability related to airport operation and continuously improving air navigation system. ASMS (air navigation service provider (ANSP) safety maturity survey) is to determine the level of management and safety requirement such as organization, risk, policy, process, training and environment in Air traffic service field. We designed and developed the survey (26 study areas of management part and 23 study areas of safety part) considering global best practices (Eurocontrol and FAA) and customizing domestic circumstances with quantitative level assessment regarding management and safety issue of Air navigation system. The survey enables the performance of Air navigation system to enhance and prevents from occurring accident or incident. Therefore, we provides best information with users as well as high quality Air traffic service.

Transition from Conventional to Reduced-Port Laparoscopic Gastrectomy to Treat Gastric Carcinoma: a Single Surgeon's Experience from a Small-Volume Center

  • Kim, Ho Goon;Kim, Dong Yi;Jeong, Oh
    • Journal of Gastric Cancer
    • /
    • 제18권2호
    • /
    • pp.172-181
    • /
    • 2018
  • Purpose: This study aimed to evaluate the surgical outcomes and investigate the feasibility of reduced-port laparoscopic gastrectomy using learning curve analysis in a small-volume center. Materials and Methods: We reviewed 269 patients who underwent laparoscopic distal gastrectomy (LDG) for gastric carcinoma between 2012 and 2017. Among them, 159 patients underwent reduced-port laparoscopic gastrectomy. The cumulative sum technique was used for quantitative assessment of the learning curve. Results: There were no statistically significant differences in the baseline characteristics of patients who underwent conventional and reduced-port LDG, and the operative time did not significantly differ between the groups. However, the amount of intraoperative bleeding was significantly lower in the reduced-port laparoscopic gastrectomy group (56.3 vs. 48.2 mL; P<0.001). There were no significant differences between the groups in terms of the first flatus time or length of hospital stay. Neither the incidence nor the severity of the complications significantly differed between the groups. The slope of the cumulative sum curve indicates the trend of learning performance. After 33 operations, the slope gently stabilized, which was regarded as the breakpoint of the learning curve. Conclusions: The surgical outcomes of reduced-port laparoscopic gastrectomy were comparable to those of conventional laparoscopic gastrectomy, suggesting that transition from conventional to reduced-port laparoscopic gastrectomy is feasible and safe, with a relatively short learning curve, in a small-volume center.

The Case Analysis through Fire Simulation FDS and Evacuation Simulation Pathfinder (화재 시뮬레이션 FDS와 피난시뮬레이션 Pathfinder 사례분석)

  • Kim, Jong Yoon;Jeon, Yong Han
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • 제10권6호
    • /
    • pp.253-260
    • /
    • 2015
  • In this study, using the FDS as the fire simulation and evacuation simulations of the Pathfinder, set the main control room of the building to the fire point fire safety assessment studies were carried out. At first the quantitative result such as distribution of visibility as time passing, distribution of temperature, distribution of CO density produced results using fire-simulation and evacuation-simulation was carried out based on the result that produced the final safety evaluation result as being calculated of evacuation time. As the risk increased with the distribution of visibility at the result of fire-simulation, evacuation-simulation was carried out using the result. Finally the result was made 127.9 sec that everyone could evacuate. The numerical results are analyzed in case of the places in the building required safe egress time for safety a as the analysis to be no more than available safe egress time was analyzed to be secured. The results of this safety evaluation represent that more smooth evacuation safety performance can be secured by linking the event of fire firefighting equipment as a result of simulating the worst conditions.

  • PDF

Evaluation and Selection Method of Best Available Techniques for Integrated Environmental Management System (통합환경관리제도 운영을 위한 최적가용기법 평가·선정기법 연구)

  • Park, Jae Hong
    • Journal of Korean Society on Water Environment
    • /
    • 제33권3호
    • /
    • pp.348-358
    • /
    • 2017
  • The process of evaluating and selecting the best available techniques presents various characteristics for each country. In the case of EU, BAT is selected through TWG meeting after first screening, mass and energy balance, impact assessment and decision support process. Korea has proposed four principles to select BAT that can be carbon neutral for each environmental infrastructure in order to reduce greenhouse gas emissions. In order to evaluate and select the best available technique, it is necessary to differentiate the method according to whether it is a technique generally applied at the current workplace, whether it is a single technique or a combination technique, and whether it is a technology technique or management technique. In the case of a single technique, it should be evaluated whether it is a technique applied in the workplace, excessive cost, superior environmental technique over BAT, and secondary environmental pollution. In the case of multiple techniques, it is necessary to examine whether the emission standards are met and whether the pollutants can be treated at the same level as BAT. In the case of BAT candidates for management techniques, whether or not they contribute directly or indirectly to lowering the emission level of pollutants can be an important evaluation item. In the case of environmental techniques that are not generally applied in the workplace, it is recommended that the following 8 steps be carried out, including those prescribed by law. In the first stage, the list of performance evaluation factors is listed. In the second stage, the level of disposal of pollutants and the level of satisfaction with standards are listed. In the third stage, the environmental evaluation elements are listed. In the fourth stage, Is to list the economic evaluation elements, step 6 is to list the pollution and accident prevention evaluation factors, step 7 is the quantitative evaluation of the technical working group, and step 8 is BAT confirmation through deliberation of the central environmental policy committee.

Development of DNA-Based Assessment Method for Mold in Floor Dust of Dwellings in Korea (바닥 먼지내에서 DNA 기반 곰팡이 분석기법 개발)

  • Lee, Jeong-Sub;Kim, Sung Yeon;Choi, Kil Yong;Ryu, Jungmin;Hwang, Eun Seol;Lee, Juyeong;Kwon, Myunghee;Chung, Hyenmi;Seo, SungChul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • 제27권4호
    • /
    • pp.324-332
    • /
    • 2017
  • Objectives: Much scientific evidence indicate a positive association between moldy environments and respiratory illnesses and/or symptoms. However, few comprehensive assessments of mold have been performed for such settings. Spore counts or microscopic enumeration only may not be sufficient for evaluating fungal exposure. Recently, Mold Specific QPCR technology developed by the US EPA (Environmental Relative Moldiness Index, ERMI) has been widely used worldwide and great performance for assessing fungal exposure has been shown. Methods: We aimed to develop a Korean version of ERMI suitable for the distribution of fungal flora in Korea. Thirty dwellings in the Seoul and Incheon area were selected for sampling, and each was classified as 'Flooded, 'Water-damaged' or 'Non-water-damaged'. Results: Dust on the floor and airborne sampling were collected using an MAS100 and a 'Dustream' collector. Samples were analyzed by quantitative polymerase chain reaction(QPCR) for the 36 molds belonging to ERMI. Student t-test and ANOVA tests were carried out using SAS software. The median ERMI values of flooded, water damaged, and non-water damaged dwellings were 8.24(range: -5.6 to 27.9), 5.47(-25. 4 to 32.7), and -15.30(-24.6 to 14.8), respectively. Significant differences were observed between flooded and non-water damaged dwellings (P=0.001) and between water-damaged and non-water damaged dwellings (P=0.032). Conclusion: Our findings indicate that ERMI values attributed to dust samples in Korea could be applicable for the identification of flooded or water damaged buildings. However, much data is needed for continuously developing the Korean version of ERMI values.

Evaluation of Combined Quantification of PCA3 and AMACR Gene Expression for Molecular Diagnosis of Prostate Cancer in Moroccan Patients by RT-qPCR

  • Maane, Imane Abdellaoui;El Hadi, Hicham;Qmichou, Zineb;Al Bouzidi, Abderrahmane;Bakri, Youssef;Sefrioui, Hassan;Dakka, Nadia;Moumen, Abdeladim
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권12호
    • /
    • pp.5229-5235
    • /
    • 2016
  • Prostate cancer (PCa) remains one of the most widespread and perplexing of all human malignancies. Assessment of gene expression is thought to have an important impact on cancer diagnosis, prognosis and therapeutic decisions. In this context, we explored combined expression of PCa related target genes AMACR and PCA3 in 126 formalin fixed paraffin embedded prostate tissues (FFPE) from Moroccan patients, using quantitative real time reverse transcription-PCR (RT-qPCR). This quantification required data normalization accomplished using stably expressed reference genes (RGs). A panel of twelve RG was assessed, data being analyzed using GenEx V6 based on geNorm, NormFinder and statistical methods. Accordingly, the hnRNP A1 gene was identified and selected as the most stably expressed RG for reliable and accurate gene expression quantification in prostate tissues. The ratios of both PCA3 and AMACR gene expression relative to that of the hnRNP A1 gene were calculated and the performance of each target gene for PCa diagnosis was evaluated using receiver-operating characteristics. PCA3 and AMACR mRNA quantification based on RT-qPCR may prove useful in PCa diagnosis. Of particular interesting, combining PCA3 and AMACR quantification improved PCa prediction by increasing sensitivity with retention of good specificity.

Based on ISO Requirements for Sustainability Management Establishment of Evaluation Model for Supplier _ Only for Semiconductor Processes (지속가능경영을 위한 ISO 요구사항 기반 정량적 협력업체 평가모델 구축 _반도체 공정에 한하여)

  • Yu, Je-Young;Lee, Ik-Mo;Hwang, Yong-Woo;Kim, Young-Woon
    • Journal of the Korea Safety Management & Science
    • /
    • 제21권2호
    • /
    • pp.25-42
    • /
    • 2019
  • The government announced that it would ask the contractors not only the supplier but also the contractors to take the same responsibilities if they did not observe industrial accident safety measures from 2019. The semiconductor manufacturing process belongs to the representative disaster industry group in which the facility is directly located inside a closed space called clean room. According to previous studies, the semiconductor industry group used checklists for safety management of their suppliers. This study has developed a model for assessing suppliers by constructing a quantitative checklist item through the risk assessment methodology, laws and regulations. The evaluation model of the supplier set up through this study becomes the safety management standard in the semiconductor industry. Furthermore, it is applied to the partner companies in the operation of ISO 14001, 45001, I would like to apply it as a measure of performance management for CSR (Corporate Social Responsibility).

Calculation of correction coefficients for the RedEdge-MX multispectral camera through intercalibration with a hyperspectral sensor (초분광센서와의 상호교정을 통한 RedEdge-MX 다분광 카메라의 보정계수 산출)

  • Baek, Seungil;Koh, Sooyoon;Kim, Wonkook
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • 제38권6호
    • /
    • pp.707-716
    • /
    • 2020
  • Spectroradiometers have recently been drawing great attention in earth observing communities for its capability for obtaining target's quantitative properties. In particular, light-weighted multispectral cameras are gaining popularity in many field domains, as being utilized on UAV's. Despite the importance of the radiometric accuracy, studies are scarce on the performance of the inexpensive multispectral camera sensors that have various applications in agricultural, vegetation, and water quality analysis. This study conducted assessment of radiometric accuracy for MicaSense RedEdge-MX multispectral camera, by comparing the radiometric data with an independent hyperspectral sensor having NIST-traceable calibration quality. The comaprison showed that radiance from RedEdge-MX is lower than that of TriOS RAMSES by 5 to 16% depending on the bands, and the irradiance from RedEdge-MX is also lower than RAMSES by 1~20%. The correction coefficients for RedEdge-MX alculated through the 1-st and the 3-rd order regression analysis were presented as a result of the study.

Structural evaluation of degradation products of Loteprednol using LC-MS/MS: Development of an HPLC method for analyzing process-related impurities of Loteprednol

  • Rajesh Varma Bhupatiraju;Bikshal Babu Kasimala;Lavanya Nagamalla;Fathima Sayed
    • Analytical Science and Technology
    • /
    • 제37권2호
    • /
    • pp.98-113
    • /
    • 2024
  • The current investigation entails the characterization of five degradation products (DPs) formed under different stress conditions of loteprednol using liquid chromatography-tandem mass spectrometry (LC-MS/MS). In addition, this study developed a stable high-performance liquid chromatography (HPLC) method for evaluating loteprednol along with impurities. The method conditions were meticulously fine-tuned which involved the exploration of the appropriate solvent, pH, flow of the mobile phase, columns, and wavelength. The method conditions were carefully chosen to successfully resolve the impurities of loteprednol and were employed in subsequent validation procedures. The stability profile of loteprednol was exposed to stress degradation experiments conducted under five conditions, and DPs were structurally characterized by employing LC-MS/MS. The chromatographic resolution of loteprednol and its impurities along with DPs was effectively achieved using a Phenomenex Luna 250 mm C18 column using 0.1 % phosphoric acid, methanol, and acetonitrile in 45:25:30 (v/v) pumped isocratically at 0.8 mL/min with 243 nm wavelength. The method produces an accurate fit calibration curve in 50-300 ㎍/mL for loteprednol and LOQ (0.05 ㎍/mL) - 0.30 ㎍/mL for its impurities with acceptable precision, accuracy, and recovery. The stress-induced degradation study revealed the degradation of loteprednol under basic, acidic, and photolytic conditions, resulting in the formation of seven distinct DPs. The efficacy of this method was validated through LC-MS/MS, which allowed for the verification of the chemical structures of the newly generated DPs of loteprednol. This method was appropriate for assessing the impurities of loteprednol and can also be appropriate for structural and quantitative assessment of its degradation products.

Changes in Electrophysiological Activation Due to Different Levels of Cognitive Load (인지부하의 정도에 따른 뇌신경생리학적 변화)

  • Kwon, Joo-Hee;Kim, Euijin;Kim, Jeonghui;Im, Chang-Hwan;Kim, Do-Won
    • Journal of Biomedical Engineering Research
    • /
    • 제43권1호
    • /
    • pp.52-60
    • /
    • 2022
  • Purpose: For now, cognitive load is assessed based on survey-based methods, which can be difficult to track the amount of cognitive load in real-time. In this study, we investigated the difference in electrophysiological activation due to different levels of cognitive load not only at sensor-level but also at source-level using electroencephalogram that might be potentially used for quantitative cognitive load evaluation. Materials and Methods: In this study, ten healthy subjects (mean age 24.3 ± 2.1, three female) participated the experiment. All participants performed 4 sessions of n-back task in different difficulties: 0-, 1-, 2-, and 3-back during electroencephalogram recording. For sensor-level analysis, we calculated the event-related potential and event-related spectral perturbation while low resolution brain electromagnetic tomography (LORETA) to estimate the source activation. Each result was compared between different workload conditions using statistical analysis. Results: Statistical results revealed that the accuracy of the task performance was significantly different between different cognitive loads (p = 0.018). The post-hoc analysis confirmed that the accuracy of the 3-back task was significantly decreased compared to 1-back condition (p = 0.018), but not with 2-back condition (p = 0.180). ERP results showed that P300 target amplitude between 1-back and 3-back had a marginal difference in Cz (p = 0.059) and Pz(p = 0.093). A significant inhibition in Cz high-beta activation (p = 0.017) and decrease in source activation of right parahippocampal gyrus was found in 3-back condition compared to 1-back condition (p < 0.05). Conclusion: In this study, we compared the sensor- and source-level differences in electroencephalogram between different levels of cognitive load, that were found to be in line with the previous reports related to cognitive load evaluation. We expect that the outcome of the current study can be used as a feature to establish a quantitative cognitive load assessment system.