• Title/Summary/Keyword: Quantitative Method

Search Result 5,973, Processing Time 0.046 seconds

The Case Study of Emotional Marketing by Visual Design (감성디자인을 통한 감성마케팅의 실증적 사례 연구 - 마블 프라이팬 사례 조사를 통한 -)

  • Kang, Bum-Kyu;Go, Jung-Wook;Ye, Min-Ju
    • Science of Emotion and Sensibility
    • /
    • v.10 no.3
    • /
    • pp.355-366
    • /
    • 2007
  • The human's emotion has been used as a key factor in the design area and a marketing technique in a company. Therefore, a company is very interesting in human' emotional factor for the marketing and the design development recently. There have been very few studies carried out on enhancing how to use the emotional design and the emotional marketing in the kitchenware industry. Besides, almost all of the research works, which attempted to encourage how to use emotional factor for the design and the marketing, was carried out in the theory research level rather than a practical research. This research has been conducted both a qualitative research and a quantitative research in the field. The research methods were as follows; first, this research studied what is the emotional design and the emotional marketing through the previous literature research works. second, the researchers set up the hypothesis and research aims through the previous empirical research works from the researchers who are doing this research. Third, as the main body of this research, this research was conducted through the analysis of companies' data, the data come from the interviews by managers, and the data from questionnaire by the users. The results was produced after analyses of the above all the data. As a results, this research has introduced the successful case study which used the emotional design concept and the emotional marketing as a strategic level in the kitchenware industry. This research results would be able to help some one who wants to use the emotional design as a strategic level in order to increase their market share.

  • PDF

Urine endothelin-1 as a Biomarker for Urinary Tract Infections in Children (Urine endothelin-1의 소아 요로 감염 환아에서의 진단적 유용성)

  • Kee, Hyung Min;Yi, Dae Yong;Yun, Ki Wook;Lim, In Seok;Ha, Tae-Seon
    • Childhood Kidney Diseases
    • /
    • v.18 no.1
    • /
    • pp.36-41
    • /
    • 2014
  • Purpose: Urinary tract infections (UTIs) are the most common source of bacterial infections in infants and young children. Accurate diagnosis and treatment is important because of their association with renal scarring, which can lead to complications. Urine endothelin-1 (ET-1) is the major renal isoform produced and released by renal mesangial cells in response to glomerular injury. This study aimed to investigate whether urinary levels of ET-1 can be used as a biomarker for UTI diagnosis. Method: We conducted a prospective study using medical records of 70 patients below the age of 18 years, who visited Chung-Ang University Hospital from July 2012 to July 2013. We classified the patients into the UTI and control groups based on urine culture studies. The UTI group was further divided into upper and lower UTI groups using 99m-Technetium dimercaptosuccinic acid scintigraphy. Urine ET-1 was measured using enzyme linked immunosorbent assay with 0.3 mL urine. Results: The UTI and control groups were comprised of 45 and 25 patients, respectively. Mean urine ET-1 levels were significantly higher in the UTI group than in the control group ($1.41{\pm}0.35$ pg/mL vs. $0.33{\pm}0.07$ pg/mL, P =0.04). There was no significance difference in the quantitative value between the upper and lower UTI groups (P =0.552). There was no correlation between urine ET-1 and serum C-reactive protein (Pearson correlation [R]=0.24), urine ET-1 and serum white blood cell count (R=0.19). Conclusion: Our study suggests that urine ET-1 can be used for early diagnosis of UTI in children.

Activation Analysis of Dual-purpose Metal Cask After the End of Design Lifetime for Decommission (설계수명 이후 해체를 위한 금속 겸용용기의 방사화 특성 평가)

  • Kim, Tae-Man;Ku, Ji-Young;Dho, Ho-Seog;Cho, Chun-Hyung;Ko, Jae-Hun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.14 no.4
    • /
    • pp.343-356
    • /
    • 2016
  • The Korea Radioactive Waste Agency (KORAD) has developed a dual-purpose metal cask for the dry storage of spent nuclear fuel that has been generated by domestic light-water reactors. The metal cask was designed in compliance with international and domestic technology standards, and safety was the most important consideration in developing the design. It was designed to maintain its integrity for 50 years in terms of major safety factors. The metal cask ensures the minimization of waste generated by maintenance activities during the storage period as well as the safe management of the waste. An activation evaluation of the main body, which includes internal and external components of metal casks whose design lifetime has expired, provides quantitative data on their radioactive inventory. The radioactive inventory of the main body and the components of the metal cask were calculated by applying the MCNP5 ORIGEN-2 evaluation system and by considering each component's chemical composition, neutron flux distribution, and reaction rate, as well as the duration of neutron irradiation during the storage period. The evaluation results revealed that 10 years after the end of the cask's design life, $^{60}Co$ had greater radioactivity than other nuclides among the metal materials. In the case of the neutron shield, nuclides that emit high-energy gamma rays such as $^{28}Al$ and $^{24}Na$ had greater radioactivity immediately after the design lifetime. However, their radioactivity level became negligible after six months due to their short half-life. The surface exposure dose rates of the canister and the main body of the metal cask from which the spent nuclear fuel had been removed with expiration of the design lifetime were determined to be at very low levels, and the radiation exposure doses to which radiation workers were subjected during the decommissioning process appeared to be at insignificant levels. The evaluations of this study strongly suggest that the nuclide inventory of a spent nuclear fuel metal cask can be utilized as basic data when decommissioning of a metal cask is planned, for example, for the development of a decommissioning plan, the determination of a decommissioning method, the estimation of radiation exposure to workers engaged in decommissioning operations, the management/reuse of radioactive wastes, etc.

Evaluation of Image Quality for Various Electronic Portal Imaging Devices in Radiation Therapy (방사선치료의 다양한 EPID 영상 질평가)

  • Son, Soon-Yong;Choi, Kwan-Woo;Kim, Jung-Min;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Cho, Jeong-Hee;Lee, Jea-Hee;Jung, Jae-Yong;Kim, Ki-Won;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.451-461
    • /
    • 2015
  • In megavoltage (MV) radiotherapy, delivering the dose to the target volume is important while protecting the surrounding normal tissue. The purpose of this study was to evaluate the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE) using an edge block in megavoltage X-ray imaging (MVI). We used an edge block, which consists of tungsten with dimensions of 19 (thickness) ${\times}$ 10 (length) ${\times}$ 1 (width) $cm^3$ and measured the pre-sampling MTF at 6 MV energy. Various radiation therapy (RT) devices such as TrueBeam$^{TM}$ (Varian), BEAMVIEW$^{PLUS}$ (Siemens), iViewGT (Elekta) and Clinac$^{(R)}$iX (Varian) were used. As for MTF results, TrueBeam$^{TM}$(Varian) flattening filter free(FFF) showed the highest values of $0.46mm^{-1}$ and $1.40mm^{-1}$ for MTF 0.5 and 0.1. In NPS, iViewGT (Elekta) showed the lowest noise distribution. In DQE, iViewGT (Elekta) showed the best efficiency at a peak DQE and $1mm^{-1}DQE$ of 0.0026 and 0.00014, respectively. This study could be used not only for traditional QA imaging but also for quantitative MTF, NPS, and DQE measurement for development of an electronic portal imaging device (EPID).

The Effects of Discrepancy in Reconstruction Algorithm between Patient Data and Normal Database in AutoQuant Evaluation: Focusing on Half-Time Scan Algorithm in Myocardial SPECT (심근 관류 스펙트에서 Half-Time Scan과 새로운 재구성법이 적용된 정상군 데이터를 기반으로 한 정량적 분석 결과의 차이 비교)

  • Lee, Hyung-Jin;Do, Yong-Ho;Cho, Seong-Wook;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.122-126
    • /
    • 2014
  • Purpose: The new reconstruction algorithms (NRA) provided by vendor aim to shorten the acquisition scan time. Whereas depending on the installed version AutoQuant program used for myocardial SPECT quantitative analysis did not contain the normal data that NRA is applied. Thus, the purpose of this paper is to compare the results according to AutoQuant versions in myocardial SPECT applied NRA and half-time scan (HT). Materials and Methods: Rest Tl and stress MIBI data of total 80 (40 men, 40 women) patients were gathered. Data were applied HT acquisition and ASTONISH (Philips) software which is NRA. Modified autoquant of SNUH and old version of AutoQuant (full-time scan) provided by company were compared. Comparison groups were classified as coronary artery disease (CAD), 24 hrs delay and almost normal patients who have a simple pain patient. Perfusion distribution aspect, summed stress score (SSS), summed rest score (SRS), extent and total perfusion deficit (TPD) of each 25 patient who have above diseases were compared and evaluated. Results: The case of CAD, when using re-edited AutoQuant (HT) SSS and SRS showed about 30% reduction (P<0.0001), Extent showed about 38% reduction and TPD showed about 30% reduction in the tendency (P<0.0001). In the score of the perfusion, especially on the part of infero-medium, infero-apical, lateral-medium and lateral-apical regions were the biggest change. The case of the 24 hrs delay patient SRS (P=0.042), Extent (P=0.018) and TPD (P=0.0024) showed about 13-18% reduction. And the case of simple pain patient, comparison of 4 results showed about 5-7% reduction. Conclusion: This study was started based on expectation that results could be affected by normal patient data. Normal patient data is possible to change by race and gender. It was proved that combination of new reconstruction algorithm for reducing scan time and analysis program according to scan protocol with NRA could also be affected to results. Clinical usefulness of gated myocardial SPECT is possibly increased if each hospital properly collects normal patient data for their scan acquisition protocol.

  • PDF

Comparative Evaluation for the Effect of SUV's Due to a Residual Radio-activity Location Inside Vascular Insert Devices During PET/CT Scans (PET/CT 검사 시 혈관삽입기구 내 잔여 방사능 위치에 따른 표준섭취계수의 영향 비교 평가)

  • Sim, Woo Yong;Kim, Jung Yul;Cho, Suk Won;Oh, Shin Hyun;Lim, Han Sang;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.94-97
    • /
    • 2014
  • Purpose: Standardized uptake value (SUV) is a simple semi-quantitative method that can measure the ratio of the tissue radioactivity between the tumor and normal. SUV is commonly used in PET/CT, however, SUV is affected by various factor. The purpose of this study was to evaluate the impact of the residual activity on SUV depending on the location of catheter insertion device post injection. Materials and Methods: NEMA IEC Body Phantom was imaged using a Discovery 600 PET scanner. In 22 mm diameter sphere, the different activity of $^{18}F-FDG$ (7.4, 14.8, 22.2, 29.6, 37, 55.5 MBq) was filled and background was filled with $^{18}F-FDG$ (5.7 kBq/mL). We scaned the phantom on the assumption that the radioactivity in sphere was residual activity in insertion device. Simulation of PET was divided into three groups based on the location of sphere in Scan FOV (SFOV); inclusion, 1/2 inclusion and exclusion group. Results: Among three groups, the group of excluded sphere showed the highest SUV regardless of the amount of $^{18}F-FDG$ activity. In case of 7.4 MBq, average SUV of inclusion group, 1/2 inclusion and exclusion group was 0.780, 0.840 and 0.896 respectively. However, average SUV of 55.5 MBq showed 0.372, 0.460 and 0.508 with same order. Depend on residual radioactivity in the sphere and position of sphere, the SUV was different minimum of 10.4%, maximum of 62.8%. Conclusion: This study showed that SUV is underestimated as the residual radio-activity is increased. In addition, SUV was a changed according to the position of residual radio-activity. And among the position, exclusion group showed the difference of SUV was lowest. If we measure the residual radio-activity of inserting devices and radio-activity from extra-vasation in the patients, it seems to be more useful in clinical field.

  • PDF

Wetland Function Evaluation and Expert Assessment of Organic Rice-Fish Mixed Farming System (유기농 벼-담수어 복합영농의 습지기능평가 및 전문가 조사)

  • Nam, Hongsik;Park, Kwanglai;An, Nanhee;Lee, Sangmin;Cho, Junglai;Kim, Bongrae;Lim, Jongahk;Lee, Changwon;Choi, Seonu;Kim, Changhyun;Kong, Minjae;Son, Jinkwan
    • Journal of Wetlands Research
    • /
    • v.20 no.2
    • /
    • pp.161-172
    • /
    • 2018
  • A mixed farming system that includes organic rice production and freshwater fish farming is being called into attention in Korean agricultural industry and rural areas in order to improve farm management and environmental conservation. This study was conducted to evaluate the environmental and ecological value of such mixed farming practices. Expert assessment and rapid assessment method (RAM) of wetland evaluation were employed for this study. Experts have responded that biodiversity conservation including amphibian and reptile habitat (2.39), aquatic insect habitat (2.36), Fishery habitat (2.34), vegetation diversity (2.13), avian habitat (2.05), and experience and education were the most important function of mixed farming. The wetland function evaluation conducted using modified RAM indicated that rice-fish mixed system showed improvements in most of the evaluated functions, compared to the conventional rice paddies. The overall wetland function of rice paddies in rice-fish mixed system was greatly improved as compared with the conventional rice paddies. Rice paddies are known to play an important role in biodiversity maintenance, and provide ecosystem services such as climate modulation and carbon reduction. Rice-fish mixed system of farming may not only improve various ecosystem services of rice paddies, but may increase farm income through value added fish farming, as well as promotion of social services such as education and maintenance of tradition. Additional research is needed for quantitative analysis of the values gained from the most improved wetland function when mixed farming system is actually put into practice, and to utilize the results in advertising of the organic rice, and in various sectors such as food, education and direct payment policy.

Study on the Behavior of Colloidal Hematite: Effects of Ionic Composition and Strength and Natural Organic Matter in Aqueous Environments (교질상 적철석의 거동 특성: 수환경 내 이온 조성 및 세기, 자연 유기물이 미치는 영향)

  • Lee, Woo-Chun;Lee, Sang-Woo;Kim, Soon-Oh
    • Economic and Environmental Geology
    • /
    • v.53 no.4
    • /
    • pp.347-362
    • /
    • 2020
  • Iron (hydro)oxides in aqueous environments are primarily formed due to mining activities, and they are known to be typical colloidal particles disturbing surrounding environments. Among them, hematites are widespread in surface environments, and their behavior is controlled by diverse factors in aqueous environments. This study was conducted to elucidate the effect of environmental factors, such as ionic composition and strength, pH, and natural organic matter (NOM) on the behavior of colloidal hematite particles. In particular, two analytical methods, such as dynamic light scattering (DLS) and single-particle ICP-MS (spICP-MS), were compared to quantify and characterize the behavior of colloidal hematites. According to the variation of ionic composition and strength, the aggregation/dispersion characteristics of the hematite particles were affected as a result of the change in the thickness of the diffuse double layer as well as the total force of electrostatic repulsion and van der Walls attraction. Besides, the more dispersed the particles were, the farther away the aqueous pH was from their point of zero charge (PZC). The results indicate that the electrostatic and steric (structural) stabilization of the particles was enhanced by the functional groups of the natural organic matter, such as carboxyl and phenolic, as the NOM coated the surface of colloidal hematite particles in aqueous environments. Furthermore, such coating effects seemed to increase with decreasing molar mass of NOM. On the contrary, these stabilization (dispersion) effects of NOM were much more diminished by divalent cations such as Ca2+ than monovalent ones (Na+), and it could be attributed to the fact that the former acted as bridges much more strongly between the NOM-coated hematite particles than the latter because of the relatively larger ionic potential of the former. Consequently, it was quantitatively confirmed that the behavior of colloidal hematites in aqueous environments was significantly affected by diverse factors, such as ionic composition and strength, pH, and NOM. Among them, the NOM seemed to be the primary and dominant one controlling the behavior of hematite colloids. Meanwhile, the results of the comparative study on DLS and spICPMS suggest that the analyses combining both methods are likely to improve the effectiveness on the quantitative characterization of colloidal behavior in aqueous environments because they showed different strengths: the main advantage of the DLS method is the speed and ease of the operation, while the outstanding merit of the spICP-MS are to consider the shape of particles and the type of aggregation.

Assessment of Both Standard and Isolated Vibrio parahaemolyticus on Efficacy of Commercial Sanitizers and Disinfectants (Vibrio parahaemolyticus 표준 및 식품분리 균주에 대한 살균소독제 유효성분별 감수성 평가)

  • Kim, Il-Jin;Kim, Yong-Su;Kim, Hyung-Il;Choi, Hyun-Chul;Jeon, Dea-Hoon;Lee, Young-Ja;Ha, Sang-Do
    • Journal of Food Hygiene and Safety
    • /
    • v.22 no.2
    • /
    • pp.127-131
    • /
    • 2007
  • This study evaluated the bactericidal effect of 10 sanitizers and disinfectants such as ethanol (75 and 95%), iodine (15 and 25 ppm), chlorine (100 and 200 ppm), quaternary ammonium, acid, hydrogen peroxide, and peroxide acetic acid against V. parahaemolyticus. Ten strains of V. parahaemolyticus isolated from Korean foods and 4 strains of standard V. parahaemolyticus were compared for efficacies of various sanitizers and disinfectants by EN 1276 method based on quantitative suspension test. Ethanol (75 and 95%), 25 ppm of iodine, 100 ppm of quaternary ammonium, 145 ppm of hydrogen peroxide and acid showed more than $5log_{10}CFU/mL$ reduction in both clean and dirty conditions. Tests result of chlorine (100 ppm) showed more than $5log_{10}CFU/mL$ reduction in clean condition. Iodine (15 ppm) showed more than $5log_{10}CFU/mL$ reduction except 4 isolated and 1 standard V. parahaemolyticus in clean condition. iodine (15 ppm) also showed under $5log_{10}CFU/mL$ reduction $(0.93{\sim}3.73log_{10}CFU/mL)$ in dirty condition. Eleven hundred ppm of hydrogen peroxide was evaluated as weak sanitizer and disinfectant due to their $0.99{\sim}4.79log_{10}CFU/mL$ reduction on both clean and dirty conditions. Consequently, ethanol, iodine (25 ppm), chlorine (200 ppm), quaternary ammonium, acid and peroxide acetic acid were thought to be effective sanitizer and disinfectant against V. parahaemolyticus.

Quantitative Analysis of Amylose and Protein Content of Rice Germplasm in RDA-Genebank by Near Infrared Reflectance Spectroscopy (근적외선 분광분석법을 이용한 벼 유전자원의 아밀로스 함량과 단백질 함량 정량분석)

  • Kim, Jeong-Soon;Cho, Yang-Hee;Gwag, Jae-Gyun;Ma, Kyung-Ho;Choi, Yu-Mi;Kim, Jung-Bong;Lee, Jeong-Heui;Kim, Tae-San;Cho, Jong-Ku;Lee, Sok-Young
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.53 no.2
    • /
    • pp.217-223
    • /
    • 2008
  • Amylose and protein contents are important traits determining the edible quality of rice, especially in East Asian countries. Near-Infrared Reflectance Spectroscopy (NIRS) has become a powerful tool for rapid and nondestructive quantification of natural compounds in agricultural products. To test the practically of using NIRS for estimation of brown rice amylose and protein contents, the spectral reflectances ($400{\sim}2500\;nm$) of total 9,483 accessions of rice germplasm in Rural development Administration (RDA) Genebank ere obtained and compared to chemically determined amylose and protein content. The protein content of tested 119 accessions ranged from 6.5 to 8.0% and 25 accessions exhibited protein contents between 8.5 to 9.5%. In case of amylose content, all tested accessions ranged from 18.1 to 21.7% and the grade from 18.1 to 19.9% includes most number of accessions as 152 and 4 accessions exhibited amylose content between 20.5 to 21.7%. The optimal performance calibration model could be obtained from original spectra of brown rice using MPLS (Modified Partial Least Squares) with the correlation coefficients ($r_2$) for amylose and protein content were 0.865 and 0.786, respectively. The standard errors of calibration (SEC) exhibited good statistic values: 2.078 and 0.442 for amylose and protein contents, respectively. All these results suggest that NIR spectroscopy may serve as reputable and rapid method for quantification of brown rice protein and amylose contents in large numbers of rice germplasm.