Dynamic Characteristic Change of the Cerebral Blood Volume in Cats Using Perfusion MR Imaging (MR 관류영상을 이용한 고양이 대뇌 혈류량의 동적특성 변화)

  • 박병래;김학진;전계록
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.243-251
    • /
    • 2004
  • This study was to quantitative analysis compare to dynamic characteristic change of the regional cerebral blood volume (rCBV) after development of cerebral fat embolism in cats using perfusion MR Imaging. Forty-four adult rats were used. Triolein (n = 15), oleic acid (n = 9) and linoleic acid (n = 11) were injected into the internal carotid artery using microcatheter through the transfemoral approach. Polyvinyl alcohol (Ivalon) (n = 9) was injected as a control group. Perfusion MR images were obtained at 30 minutes and 2 hours after embolization, based on T2 and diffusion-weighted images. The data was time-to-signal intensity curve and ΔR$_2$* curve were obtained continuously with the aid of home-maid image proc in.leased significantly at 2 hours compared with those of 30 minutes (P<0.005). In conclusion, cerebral blood flow decreased in cerebral fat embolism immediately after embolization and recovered remarkably in time course. It is thought that clinically informations to dynamic characteristic change of the cerebral hemodynamics to the early finding in cerebral infarction by DWI and PWI

Quantitative Comparison of 1H-MRS Spectra Depending on the Paramagnetic Gadolinium Contrast Agent(GBCA) Injection (가돌리늄 조영제 주입에 따른 1H-MRS spectrum의 정량적 비교)

  • Choi, Kwan-Woo;Son, Soon-Yong;Yoo, Beong-Gyu
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.589-595
    • /
    • 2017
  • This study evaluated the effect of gadolinium contrast agents on the spectrum of metabolites during $^1H-MRS$ of brain and to investigate whether the contrast agents injected before MR spectroscopy significantly affect the estimated peaks of MRS. From January to May 2017, brain MR spectroscopy was performed on 30 patients to compare the spectrum before and after contrast injection of the brain white matter tissue. As a result, the spectrum of metabolites decreased after the paramagnetic contrast agents injected. However, it was not statistically significant which indicated that the use of contrast agent did not meaningfully affect the spectrum of metabolites. In conclusion, the use of the paramagnetic contrast before the acquisition of the spectroscopy may aid voxel positioning especially when it is difficult to determine the exact location of the lesion or the contrast is low.

Syringe Reuse Issues in Automated Contrast Injection System in Dynamic Magnetic Resonance Imaging (조영제 자동주입기를 활용한 자기공명영상 동적검사 시 실린지 재사용의 문제)

  • Son, Soon-Yong
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.11
    • /
    • pp.445-450
    • /
    • 2019
  • This study proves that syringe reuse of automated injection system entails a risk of contrast media reflux and saline solution contamination which are pumped by a piston into the patients' venous cannula in the dynamic MR images, we will be aware of the serious problem. To quantify the contrast media contamination effect on the saline solution, identical volume of the saline solution was collected before and after the contrast injection to the patients' venous cannula following T1 weighted image scanning to verify whether signal intensities differences are observed. The signal intensity of saline solution after the contrast injection was significantly higher than that of saline before injection by 523.43%. This result is due to the backflow that contaminates the saline solution on the opposite side when the contrast agent is injected. In conclusion, the syringe used to inject contrast medium. causes cross-contamination due to contrast reflux. Therefore, even if the same patient's examination is used for quantitative analysis, the error should be avoided by changing the acquisition sequence or replacing the syringe.

A Study on the Metabolite Changes in Brain Diseases: 3 Teslar 1H Magnetic Resonance Spectroscopy (뇌질환 대사물질 변화의 고찰; 3 Teslar 수소 자기공명분광법)

  • Eun, Sungjong;Kim, Jeongjae;Yoo, Seungcheol
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.1
    • /
    • pp.35-42
    • /
    • 2014
  • The purpose of this study is to know the differences of metabolism in abnormal brain disease using a single-voxel proton MR spectroscopy(1H MRS) Together with five normal volunteers and each five patients with brain diseases, pathologically proved, underwent MRI and 1H MRS. The quantitative results of 1H MRS in adrenoleukodystrophy(ALD), hepatic encephalopathy(HE), and infarction gave unique information on the metabolite changes related with the white matter: the concentration of NAA decreased in all diseases; Cho, mI and Lac increased in ALD; Cho decreased in HE; and ${\beta}{\cdot}{\gamma}$-Glx and Lac increased in infarction. It is concluded that 1H MRS is capable of diagnosing brain diseases by monitoring metabolite changes in vivo that subsequently develope into abnormalities. 1H MRS may be a useful clinical tool for in both diagnosis and prognosis of brain diseases.

Analysis of Inflow and Susceptibility Effects in fMRI Obtained by CGE and TRFGE Techniques (CGE와 TRFGE 기법으로 얻은 뇌기능 영상에서 혈류효과와 자화율 효과의 해석)

  • No, Yong-Man;Jeong, Sun-Cheol;Jo, Jang-Hui
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.4
    • /
    • pp.431-438
    • /
    • 1995
  • Functional imaging based on the susceptibility only is achieved by separation of the susceptibility effect from the mixture of flow effect by use of a tailored RF pulse in conjunction with gradient echo sequence. Using the tailored RF pulse the susceptibility enhanced functional imaging appears to be explicitly related to the deoxygenation processes, while in the conventional gradient echo technique functional contrast on $T2^{*}$ effect images appear to be mixed with a significant fraction of blood flow (in- flow) signals of both arterial as well as venous bloods due to the nature of the fast sequence employed with the gradient echo technique. In this paper, using the tailored RF pulses, one can unambiguously separate the susceptibility and flow effects in functional imaging. Since the signal obtained can be made sufficiently high and represents oxygenation process more accurately, it seems possible to study quantitative oxygen metabolisms in brain function hitherto difficult to do with other gradient echo techniques.

  • PDF

Preoperative Assessment of Cystic Brain Lesion : Significance of Diffusion-Weighted Image and ADC (Apparent Diffusion Coefficiency) Values

  • Choi, Hyun-Chul;Lee, Sang-Won;Ji, Cheol
    • Journal of Korean Neurosurgical Society
    • /
    • v.41 no.6
    • /
    • pp.371-376
    • /
    • 2007
  • Objective : The aim of this study was to investigate the usefulness of diffusion-weighted imaging [DWI] and apparent diffusion coefficiency [ADC] in distinguishing brain abscesses from cystic or necrotic brain tumors, which are difficult to be differentiated by conventional magnetic resonance imaging techniques. Methods : Seven patients with brain abscesses and ten patients with cystic brain tumors were studied from September 2003 to October 2005. Abscess, subdural empyema and ventriculitis were categorized to the abscess group and cystic or necrotic brain gliomas or metastatic brain tumors into the tumor group. Preoperative magnetic resonance images were performed in all patients and diffusion-weighted images and apparent diffusion coefficiency values of lesions were calculated directly from software of 1.5 tesla MRI [General Electrics, USA]. The ratio of the ADC of the lesion to contralateral regional ADC was also measured [relative ADC, rADC]. Results : The average ADC value of pyogenic abscesses group was $0.82+/-0.14{\times}10^{-3}\;[mean+/-S.D.]\;mm^2/s$ and mean rADC was 0.75. Cystic or necrotic areas had high ADC values [$2.49+/-0.79{\times}10^{-3}\;mm^2/s$, mean rADC=2.14]. ADC and rADC values of abscesses group showed about three times lower values than those of cystic or necrotic tumor group. Conclusion : This study results based on numerical comparison of signal intensities and quantitative analysis to distinguish between brain abscess and cystic or necrotic tumor, DWI and ADC mapping are thought to be very useful diagnostic tools.

Increased Wall Enhancement Extent Representing Higher Rupture Risk of Unruptured Intracranial Aneurysms

  • Jiang, Yeqing;Xu, Feng;Huang, Lei;Lu, Gang;Ge, Liang;Wan, Hailin;Geng, Daoying;Zhang, Xiaolong
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.2
    • /
    • pp.189-197
    • /
    • 2021
  • Objective : This study aims to investigate the relationship between aneurysm wall enhancement and clinical rupture risks based on the magnetic resonance vessel wall imaging (MR-VWI) quantitative methods. Methods : One hundred and eight patients with 127 unruptured aneurysms were prospectively enrolled from Feburary 2016 to October 2017. Aneurysms were divided into high risk (≥10) and intermediate-low risk group (<10) according to the PHASES (Population, Hypertension, Age, Size of aneurysm, Earlier SAH history from another aneurysm, Site of aneurysm) scores. Clinical risk factors, aneurysm morphology, and wall enhancement index (WEI) calculated using 3D MR-VWI were analyzed and compared. Results : In comparison of high-risk and intermediated-low risk groups, univariate analysis showed that neck width (4.5±3.3 mm vs. 3.4±1.7 mm, p=0.002), the presence of wall enhancement (100.0% vs. 62.9%, p<0.001), and WEI (1.6±0.6 vs. 0.8±0.8, p<0.001) were significantly associated with high rupture risk. Multivariate regression analysis revealed that WEI was the most important factor in predicting high rupture risk (odds ratio, 2.6; 95% confidence interval, 1.4-4.9; p=0.002). The receiver operating characteristic (ROC) curve analysis can efficiently differentiate higher risk aneurysms (area under the curve, 0.780; p<0.001) which have a reliable WEI cutoff value (1.04; sensitivity, 0.833; specificity, 0.67) predictive of high rupture risk. Conclusion : Aneurysms with higher rupture risk based on PHASES score demonstrate increased neck width, wall enhancement, and the enhancement intensity. Higher WEI in unruptured aneurysms has a predictive value for increased rupture risk.

A Systematic Review of the Attributes of Interior Design Affecting User's Positive Emotions Measured via Bio-Signals (생체신호 기반 사용자의 긍정적인 감정에 영향을 미치는 실내디자인 특성에 관한 문헌고찰)

  • Kim, Sieun;Ha, Mikyoung
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.36 no.5
    • /
    • pp.83-91
    • /
    • 2020
  • Environmental conditions are known to impact human health and behavior, emotions such as pleasure, anxiety, and depression, and reduce stress. Interior design that elevates emotional comfort and satisfaction can help improve mental health and well-being. This study is a systematic review that analyzed previous empirical studies that explored the effect of interior design elements on the user's emotional response which is quantitatively evaluated by bio-signal and qualitatively evaluated through self-reported questionnaire surveys. This paper aims to derive the attributes of interior design and biometric indicators that affect the user's positive emotion through the synthesis of previous studies and to confirm the feasibility of measuring bio-signals as an objective evaluation tool for architectural design and as a quantitative research method. As a result of the review, the biometric data from EEG, fMRI, ECG, EMG, GSR, and eye-tracking were used to measure the participants' emotional responses, which were manifested as positive or negative depending on certain attributes of interior design such as the form, color, lighting, material and furniture. The attributes of interior design related to the positive emotional response were the curved shape, high ceiling, openness of space, and subdued tone colors. Standard lighting conditions and wooden spaces were related to stress reduction in terms of comfort and relaxation. The free arrangement of furniture was related to the user's positive emotions. On the other hand, consistent experimental protocols could not be found, and although the sample sizes of the studies were small, the studies have demonstrated the feasibility of the emotional response measurement by using the biometric data. Therefore this method can be a useful objective tool in the measurement of human-centric data in architectural design, and to develop the evidence-based design to induce positive emotions and minimize stress.

THE PRELIMINARY STUDY OF THE QUANTITATIVE MORPHOLOGIC ANALYSIS USING MRI OF THE LATERAL VENTRICLE IN EARLY-ONSET PSYCHOTIC DISORDER (조기 발병한 정신증적 장애에서 자기공명영상을 이용한 측뇌실에 대한 구조적인 예비연구)

  • Lee, Youn-Hee;Kang, Min-Hee;Kim, Chul-Eung;Bae, Jae-Nam;Hong, Kang-E;Lee, Jeong-Seop
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.12 no.2
    • /
    • pp.256-262
    • /
    • 2001
  • Objective:The enlargement of the lateral ventricle is well established finding in adult-onset schizophrenia, but in the patients with early-onset psychotic disorder(EOPD) is still controversal. To identify structural abnormalities of the lateral ventricle in patients with EOPD and difference of the brain developmental course in EOPD group, planimetrical assessment of the lateral ventricle was conducted by means of retrospective quantitative neuroimaging. Methods:The brain MR images of 14 patients with EOPD(mean age $14.0{\pm}2.1$ years) who met the DSM-III-R diagnostic criteria for schizophrenia and bipolar disorder and 24 control subjects with simple headache(mean age $10.0{\pm}2.1$ years) were collected. Single best view for the lateral ventricle, one axial slice was selected for analysis. MR images were redigitalized with flatbed scanner and data were analyzed with NIH IMAGE software. Results:In the patients with EOPD, there were significant correlations between aging and lateral ventricular sizes and between aging and ventricular brain ratio(VBR). The statistical significance of normal asymmetry of the lateral ventricle was not observed for the EOPD group. The EOPD group had larger lateral ventricular sizes and VBR than control group, but these results were not statistically significant. Conclusion:These findings suggest that the brain abnormalities in patients with EOPD progress from the earlier course of the disorders and the course of brain development in EOPD group is different from control group.

  • PDF

SNR and ADC Changes at Increasing b Values among Patients with Lumbar Vertebral Compression Fracture on 1.5T MR Diffusion Weighted Images (1.5T MR 기기를 이용한 확산강조영상에서 b Value의 증가에 따른 요추압박골절 환자의 신호대 잡음비와 현성 확산 계수의 변화)

  • Cho, Jae-Hwan;Park, Cheol-Soo;Lee, Sun-Yeob;Kim, Bo-Hui
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.52-59
    • /
    • 2010
  • To examine among patients with vertebral compression fracture the extent to which signal-to-noise ratio (SNR) and Apparent Diffusion Coefficient (ADC) values at the lumbar vertebral compression fracture site vary on diffusion-weighted MR images according to varying b values on the 1.5T MR device. Diffusion-weighted MR images of 30 patients with compression fracture due to chronic osteoporosis who underwent vertebral MRI from Jan. 2008 to Nov. 2009 were respectively obtained using a 1.5-T MR scanner with the b values increased from 400, 600, 800, 1,000 to $1,200\;s/mm^2$. For diffusion-weighted MR images with different b values, the signal-to-noise ratio (SNR) was assessed at three sites: the site of compression fracture of the lumbar vertebral body at L1 to L5, and both the upper and lower discs of the said fracture site, while for ADC map images with different b values, the SNR and ADC were respectively assessed at those three sites. As a quantitative analysis, diffusion-weighted MR images and ADC map images with b value of $400\;s/mm^2$ (the base b values) were respectively compared with the corresponding images with each different b value. As far as qualitative analysis is concerned, for both diffusion-weighted MR and ADC map images with b value of $400\;s/mm^2$, the extent to which signal intensity values obtained at the site of compression fracture of the lumbar vertebral body at L1 to L5 vary according to the increasing b values were examined. The quantitative analysis found that for both diffusion-weighted MR and ADC map images, as the b values increased, the SNR were relatively lowered at all the three sites, compared to the base b value. Also, it was found that as the b values increased, ADC valueswere relatively lowered at all the three sites on ADC map images. On the other hand, the qualitative analysis found that as the b values increased to more than $400\;s/mm^2$, the signal intensity gradually decreased at all the sites, while at the levels of more than $1,000\;s/mm^2$, severe image noises appeared at all of the three sites. In addition, higher signal intensity was found at the site of compression fracture of the lumbar vertebral body than at the discs. Findings showed that with the b value being increased, both the signal-to-noise ratio (SNR) and Apparent Diffusion Coefficient (ADC) values gradually decreased at all the sites of the lumbar vertebral compression fracture and both the upper and lower discs of the fracture site, suggesting that there is a possibility of a wider range of applications to assessment of various vertebral pathologies by utilizing multi b values in the diffusion-weighted MRI examination.