• Title/Summary/Keyword: Quantitative MRI

Search Result 174, Processing Time 0.019 seconds

A Study on the Image Quality According to the Change of Flip Angle in Flow-Related Enhancement Magnetic Resonance Angiography (유속증강 자기공명혈관조영술에서 숙임각 변화에 따른 영상의 질 연구)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.201-208
    • /
    • 2018
  • The purpose of this study was to investigate the optimal flip angle by measuring the SNR and CNR according to the angle of changes of the MRI technique using the Image J program. A total of 30 normal volunteers were assessed by using a 1.5T magnetic resonance imaging system (Philips, Medical System, Achieva). For the MRI angiography, we set the region of interest in four regions and evaluated the SNR and CNR. The statistical significance of SNR and CNR was calculated by one-way ANOVA using quantitative analysis at five different positions. The Bonferroni method was used for post-hoc analyzes. Statistical significance was determined by using ANOVA analysis at p<0.05 and Bonferroni method was used as a post-hoc analysis. The results of this study, the measurement values of ACA(SNR:$876.59{\pm}14.22$, CNR:$1999.7{\pm}12.5$), PCA(SNR:$863.48{\pm}13.29$, CNR:$1870.18{\pm}12.56$), ICA(SNR:$1116.87{\pm}08.34$, CNR:$2979.37{\pm}14.69$) and MCA(SNR:$848.66{\pm}15.25$, CNR:$2199.25{\pm}13.48$) were obtained with the high signal intensity at $25^{\circ}$(p<0.05). The values of a1, a2, a3, p1, p2, p3, m1, m2 and m3 were also the same (p<0.05). Post-hoc analysis results, There was a statistically significant difference (p=0.000) between $10^{\circ}$, $15^{\circ}$, $20^{\circ}$ on the $25^{\circ}$ reference for the flip angle, but no significant results were obtained with $30^{\circ}$(p<0.05). In concision, because the signal intensity decreased at $30^{\circ}$, this study revealed that the optimal flip angles were $25^{\circ}$ in cerebrovascular MR angiography.

Usefulness of Prone Position on PET-CT in Breast Cancer (유방암 PET-CT 검사에서 Prone(복와위)자세의 유용성 평가)

  • Park, Hoon-Hee;Kim, Sei-Yung;Kim, Jung-Yul;Park, Min-Soo;Lim, Han-Snag;Jung, Suk;Kang, Chun-Goo;Kim, Jae-Sam;Lee, Chang-Ho;Lee, Yung-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.44-48
    • /
    • 2008
  • Purpose: In FDG-PET/CT of breast cancer, a sensitivity was 80~96% and a specificity was 75~95% commonly. It was valuable to identify a cancer in early stage been difficult in Mammography. Most of the PET/CT scans have been examined on supine position, so, the image of breast has been acquired by reconstructed whole body scan image. However, using prone position with a compensator, a shape of breast was reassembly shown to be real by gravity. Therefore, the purpose of this study was to evaluate diagnostic value of prone position in FDG PET-CT of breast cancer. Materials and Methods: 30 female patients with doubtful or positive breast cancer were examined. The PET-CT whole body scan was acquired at 60 minutes after $^{18}F$-FDG injection on Supine position. Then, regional breast spot scan was progressed on prone position using a compensator. Each image was evaluated by physicians blinded to patient's data, and statistical analysis did through SUVs measured in PET-CT images. Results: In 27 of 30 patients, prone position was shown accurate discrimination and diagnostic value, but in another 3 patients had a lesion 1cm below, PET-CT couldn't detect it, unlike MRI. Consequently, prone position distinguished a lesion better than Supine position, because of low degree of metamorphosis by gravity. The SUVs analysis of each position was significant (p value=0.004). Conclusion: In PET-CT of breast cancer, prone position could detect micrometastasis as well as primary lesion, better than supine position. Therefore, this study proposes that any technical change considered morphological feature like prone position can offer adequate and useful diagnostic information, together with complementary quantitative analysis.

  • PDF

Observer Variation Factor on Advanced Method for Accurate, Robust, and Efficient Spectral Fitting of java Based Magnetic Resonance User Interface for MRS data analysis (java Based Magnetic Resonance User Interface의 Advanced Method for Accurate, Robust, and Efficient Spectral Fitting 분석방법의 관찰자 변동 요소)

  • Lee, Suk-Jun;Yu, Seung-Man
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.143-148
    • /
    • 2016
  • The purpose of this study was examined the measurement error factor on AMARES of jMRUI method for magnetic resonance spectroscopy (MRS) quantitative analysis by skilled and unskilled observer method and identified the reason of independent observers. The Point-resolved spectroscopy sequence was used to acquired magnetic resonance spectroscopy data of 10 weeks male Sprague-Dawley rat liver. The methylene protons ($(-CH_{2-})n$) of 1.3 ppm and water proton ($H_2O$) of 4.7 ppm ratio was calculated by LCModel software for using the reference data. The seven unskilled observers were calculated total lipid (methylene/water) using the jMRUI AMARES technique twice every 1 week, and we conducted interclass correlation coefficient (ICC) statistical analysis by SPSS software. The inter-observer reliability (ICC) of Cronbach's alpha value was less than 0.1. The average value of seven observer's total lipid ($0.096{\pm}0.038$) was 50% higher than LCModel reference value. The jMRUI AMARES analysis method is need to minimize the presence of the residual metabolite by identified metabolite MRS profile in order to obtain the same results as the LCModel.

Evaluation of Cardiac Function Analysis System Using Magnetic Resonance Images

  • Tae, Ki-Sik;Suh, Tae-Suk;Choe, Bo-Young;Lee, Hyoung-Koo;Shinn, Kyung-Sub;Jung, Seung-Eun;Lee, Jae-Moon
    • Progress in Medical Physics
    • /
    • v.10 no.3
    • /
    • pp.159-168
    • /
    • 1999
  • Cardiac disease is one of the leading causes of death in Korea. In quantitative analysis of cardiac function and morphological information by three-dimensional reconstruction of magnetic resonance images, left ventricle provides an important role functionally and physiologically. However, existing procedures mostly rely on the extensive human interaction and are seldom evaluated on clinical applications. In this study, we developed a system which could perform automatic extraction of enpicardial and endocardial contour and analysis of cardiac function to evaluate reliability and stability of each system comparing with the result of ARGUS system offered 1.5T Siemens MRI system and manual method performed by clinicians. For various aspects, we investigated reliability of each system by compared with left ventricular contour, end-diastolic volume (EDV), end-systolic volume (ESV), stock volume (SV), ejection fraction (EF), cardiac output (CO) and wall thickness (WT). When comparing with manual method, extracted results of developed process using minimum error threshold (MET) method that automatically extracts contour from cardiac MR images and ARGUS system were demonstrated as successful rate 90% of the contour extraction. When calculating cardiac function parameters using MET and comparing with using correlation coefficients analysis method, the process extracts endocardial and epicardial contour using MET, values from automatic and ARGUS method agreed with manual values within :t 3% average error. It was successfully demonstrated that automatic method using threshold technique could provide high potential for assessing of each parameters with relatively high reliability compared with manual method. In this study, the method developed in this study could reduce processing time compared with ARGUS and manual method due to a simple threshold technique. This method is useful for diagnosis of cardiac disease, simulating physiological function and amount of blood flow of left ventricle. In addition, this method could be valuable in developing automatic systems in order to apply to other deformable image models.

  • PDF

Software Development for the Integrated Visualization of Brain Tumor and its Surrounding Fiber Tracts (뇌종양 및 그 주변 신경다발의 통합적 가시화를 위한 소프트웨어의 개발)

  • Oh Jungsu;Cho Ik Hwan;Na Dong Gyu;Chang Kee Hyun;Park Kwang Suk;Song In Chan
    • Investigative Magnetic Resonance Imaging
    • /
    • v.9 no.1
    • /
    • pp.2-8
    • /
    • 2005
  • Purpose : The purpose of this study was to implement a software to visualize tumor and its surrounding fiber tracts simultaneously using diffusion tensor imaging and examine the feasibility of our software for investigating the influence of tumor on its surrounding fiber connectivity. Material and Methods : MR examination including T1-weigted and diffusion tensor images of a patient with brain tumor was performed on a 3.0 T MRI unit. We used the skull-striped brain and segmented tumor images for volume/surface rendering and anatomical information from contrast-enhanced T1-weighted images. Diffusion tensor images for the white matter fiber-tractography were acquired using a SE-EPI with a diffusion scheme of 25 directions. Fiber-tractography was performed using the streamline and tensorline methods. To correct a spatial mismatch between T1-weighted and diffusion tensor images, they were coregistered using a SPM. Our software was implemented under window-based PC system. Results : We successfully implemented the integrated visualization of the fiber tracts with tube-like surfaces, cortical surface and the tumor with volume/surface renderings in a patient with brain tumor. Conclusion : Our result showed the feasibility of the integrated visualization of brain tumor and its surrounding fiber tracts. In addition, our implementation for integrated visualization can be utilized to navigate the brain for the quantitative analysis of fractional anisotropy to assess changes in the white matter tract integrity of edematic and peri-edematic regions in a number of tumor patients.

  • PDF

Diffus ion-Weighted MR Imaging of Spinal Cord Infarction (척수경색의 확산강조자기공명영상)

  • 김윤정;서정진;임남열;정태웅;김윤현;박진균;정광우;강형근
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.2
    • /
    • pp.166-172
    • /
    • 2002
  • Purpose : To evaluate the usefulness of diffusion-weighted imaging(DWI) and quantitative apparent diffusion coefficient (ADC) maps in the patients with spinal cord infarction. Materials and methods : We studied 6 patients presented symptoms with spinal cord infarction, retrospectively (3 men and 3 women). We obtained multi-shot echo planar-based, DWI using 1.5T MR scanner at 5.4 mean days after the onset of ischemic symptoms. In six patients, signal intensity was acquired at conventional b value $1000s/\textrm{mm}^2$). The ADC value for the normal spinal cord and for infarcted lesions was measured from the trace ADC maps by using regions of interest positioned over the spinal cord. We analyzed signal intensity of lesion on MRI and DWI, and compared with ADC values in infarcted lesions and normal site. Results : T1-weighted MR image showed isosignal intensity in four of six patients and low signal intensity in two of six. T2-weighted MR image demonstrated high signal intensity in all of six. All DWI were considered to be diagnostic. All of six depicted a bright signal intensity on DWI. ADC values of infarcted lesion were measured lower than that of normal spinal cord on ADC map. The differences in ADC values between infarcted and normal spinal cord were significantly different (p<0.05). Conclusion : It is possible to obtain DWI and ADC map of the spinal cord and DWI may be useful in the early diagnosis and localization of lesion site in patients with spinal cord infarction.

  • PDF

Study on 3D Printer Production of Auxiliary Device for Upper Limb for Medical Imaging Test (의료영상 검사를 위한 상지 보조기구의 3D 프린터 제작 연구)

  • Kim, Hyeong-Gyun;Yoon, Jae-Ho;Choi, Seong-Dae
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.389-394
    • /
    • 2015
  • There is a progressive development in the medical imaging technology, especially of descriptive capability for anatomical structure of human body thanks to advancement of information technology and medical devices. But however maintenance of correct posture is essential for the medical imaging checkup on the shoulder joint requiring rotation of the upper limb due to the complexity of human body. In the cases of MRI examination, long duration and fixed posture are critical, as failure to comply with them leads to minimal possibility of reproducibility only with the efforts of the examiner and will of the patient. Thus, this study aimed to develop an auxiliary device that enables rotation of the upper limb as well as fixing it at quantitative angles for medical imaging examination capable of providing diagnostic values. An auxiliary device has been developed based on the results of precedent studies, by designing a 3D model with the CATIA software, an engineering application, and producing it with the 3D printer. The printer is Objet350 Connex from Stratasys, and acrylonitrile- butadiene-styrene(ABS) is used as the material of the device. Dimensions are $120{\times}150{\times}190mm$, with the inner diameter of the handle being 125.9 mm. The auxiliary device has 4 components including the body (outside), handle (inside), fixture terminal and the connection part. The body and handle have the gap of 2.1 mm for smooth rotation, while the 360 degree of scales have been etched on the handle so that the angle required for observation may be recorded per patient for traceability and dual examination.

The Effect of Number of Echoes and Random Noise on T2 Relaxography : Development of 8-Echo CPMG (에코의 개수와 임의 잡음이 T2 이완영상의 구성에 미치는 영향연구 : 8에코 CPMG영상화 펄스열의 개발)

  • 정은기
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.67-72
    • /
    • 1998
  • The mapping of the spin-spin relaxation time T2 in pixel-by-pixel was suggested as a quantitative diagnostic tool in medicine. although the CPMG pulse sequence has been known to be the best pulse sequence for T2 measurement in physics NMR, the supplied pulse sequence by the manufacture of MRI system was able to obtain the maximum of 4 CPMG images. Eight or more images with different echo time TEs are required to construct a reliable T2 map, so that two or more acquisitions were required, which easily took more than 10 minutes. 4-echo CPMG imaging pulse sequence was modified to generate the maximum of 8 MR images with evenly spaced echo time TEs. In human MR imaging, since patients tend to move at least several pixels between the different acquisitions, 8-echo CPMG imaging sequence reduces the acquisition time and may remove any mis-regitration of each pixels signal for the fitting of T2. The resultant T2 maps using the theoretically simulated images and using the MR images of the human brain suggested that 8 echo CPMG sequence with short echo spacing such as 17-20 msec can give the reliable T2 map.

  • PDF

Expert Opinions and Recommendations for the Clinical Use of Quantitative Analysis Software for MRI-Based Brain Volumetry (뇌 자기공명영상 뇌용적 분석 소프트웨어의 임상적 적용에 대한 전문가 의견과 권고안)

  • Ji Young Lee;Ji Eun Park;Mi Sun Chung;Se Won Oh;Won-Jin Moon;Aging and Neurodegeneration Imaging (ANDI) Study Group, Korean Society of Neuroradiology (KSNR)
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.5
    • /
    • pp.1124-1139
    • /
    • 2021
  • The objective assessment of atrophy and the measurement of brain volume is important in the early diagnosis of dementia and neurodegenerative diseases. Recently, several MR-based volumetry software have been developed. For their clinical application, several issues arise, including the standardization of image acquisition and their validation of software. Additionally, it is important to highlight the diagnostic performance of the volumetry software based on expert opinions. We instituted a task force within the Korean Society of Neuroradiology to develop guidelines for the clinical use of MR-based brain volumetry software. In this review, we introduce the commercially available software and compare their diagnostic performances. We suggest the need for a standard protocol for image acquisition, the validation of the software, and evaluations of the limitations of the software related to clinical practice. We present recommendations for the clinical applications of commercially available software for volumetry based on the expert opinions of the Korean Society of Neuroradiology.

Comparison of Normative Percentiles of Brain Volume Obtained from NeuroQuant vs. DeepBrain in the Korean Population: Correlation with Cranial Shape (한국 인구에서 NeuroQuant와 DeepBrain에서 측정된 뇌 용적의 정상규준 백분위수 비교: 두개골 형태와의 연관성)

  • Mi Hyun Yang;Eun Hee Kim;Eun Sun Choi;Hongseok Ko
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.5
    • /
    • pp.1080-1090
    • /
    • 2023
  • Purpose This study aimed to compare the volume and normative percentiles of brain volumetry in the Korean population using quantitative brain volumetric MRI analysis tools NeuroQuant (NQ) and DeepBrain (DB), and to evaluate whether the differences in the normative percentiles of brain volumetry between the two tools is related to cranial shape. Materials and Methods In this retrospective study, we analyzed the brain volume reports obtained from NQ and DB in 163 participants without gross structural brain abnormalities. We measured threedimensional diameters to evaluate the cranial shape on T1-weighted images. Statistical analyses were performed using intra-class correlation coefficients and linear correlations. Results The mean normative percentiles of the thalamus (90.8 vs. 63.3 percentile), putamen (90.0 vs. 60.0 percentile), and parietal lobe (80.1 vs. 74.1 percentile) were larger in the NQ group than in the DB group, whereas that of the occipital lobe (18.4 vs. 68.5 percentile) was smaller in the NQ group than in the DB group. We found a significant correlation between the mean normative percentiles obtained from the NQ and cranial shape: the mean normative percentile of the occipital lobe increased with the anteroposterior diameter and decreased with the craniocaudal diameter. Conclusion The mean normative percentiles obtained from NQ and DB differed significantly for many brain regions, and these differences may be related to cranial shape.