• Title/Summary/Keyword: Quality control materials

Search Result 1,108, Processing Time 0.048 seconds

Health Assessment for Glass Fibre Landfill at Gozan-dong, Inchon (인천시 고잔동에서 제기된 유리섬유에 의한 건강피해 역학 조사)

  • Cho, Soo-Hun;Ju, Yeong-Su;Kim, Kyung-Ryul;Lee, Kang-Kun;Hong, Kug-Sun;Eun, Hee-Chul;Song, Dong-Bin;Hong, Jae-Woong;Kwon, Ho-Jang;Ha, Mi-Na;Han, Sang-Hwan;Seong, Joo-Heon;Kang, Jong-Won
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.1 s.56
    • /
    • pp.77-101
    • /
    • 1997
  • In September 1994, residents of Gozan-dong, Incheon City, made a petition to the government about their health problems which might be caused by previous glass fibre landfill nearby 'H' company. In february 1995, at regular academic meeting of occupational and environmental medicine, a research team of 'D' University presented that they had found glass fibres in groundwater of the area through their survey. They were suspicious of probable association between ingestion of groundwater contaminated with glass fibres and skin tumors among residents. A joint research team was formed and carried out the survey of environment concerning groundwater and its glass fibre existence, and health assessment of residents in the area and industrial workers of 'H' company during May to November, 1995. Analysis of groundwater flow system indicates that the flow lines from the glass fibre landfill pass through or terminate at the 6 houses around the landfill. This means that the groundwater of the 6 houses around the glass fibre landfill could be affected by some possible contaminants from the landfill, but the groundwater quality of the other houses was irrelevant to the landfill. The qualitative and qualitative analyses for glass fibres in 54 groundwater samples including those from the nearby 6 houses, were carried out using SEM equipped with EDS, resulting in no evidence for the presence of glass fibres in the waters. Major precipitates, formed in waters while boiling, were identified as calcium carbonates, in particulary, aragonites in needle form. The results of health assessments of 889 residents in Gozan-dong, participated in this study, showed statistically significant differences in past medical histories of skin tumor and respiratory disease between the exposed group (31 persons who inhabited in 6 houses around the landfill) and the control group, but no significant differences in past medical histories of other diseases, such as cancer mortality, current gastroscopic findings, current skin diseases and respiratory diseases, etc. Also, we could not prove any glass fibres in excised specimens of 9 skin tumors in both groups and there were no health problems possibly associated with glass fibres in employees of the 'H' company. After all, we could not authenticate the association, raised by prior investigators, between groundwater streams, assumedly contaminated with glass fibres or not, and specific disease morbidities or common disease/symptom prevalences. That is, we could not find any glass fibres in groundwater as the only exposure factor of this study hypothesis, and there were not enough certain evidences such as increasing disease prevalences, for examples, skin, respiratory and gastrointestinal diseases etc, possibly related to glass fibre exposure, in exposed group. As a matter of course, the conditions for confirming causal association, for example, strength of the association, consistency of the association, specificity of the association, temporality of the association and dose-response relationship etc, have not been satisfied. In conclusion, we were not able to certify the hypothesis that contamination of groundwater with glass fibres might cause any hazardous health effects in residents who used it for drinking.

  • PDF

Analysing the effect of impervious cover management techniques on the reduction of runoff and pollutant loads (불투수면 저감기법의 유출량 및 오염부하량 저감 효과 분석)

  • Park, Hyung Seok;Choi, Hwan Gyu;Chung, Se Woong
    • Journal of Environmental Impact Assessment
    • /
    • v.24 no.1
    • /
    • pp.16-34
    • /
    • 2015
  • Impervious covers(IC) are artificial structures, such as driveways, sidewalks, building's roofs, and parking lots, through which water cannot infiltrate into the soil. IC is an environmental concern because the pavement materials seal the soil surface, decreasing rainwater infiltration and natural groundwater recharge, and consequently disturb the hydrological cycle in a watershed. Increase of IC in a watershed can cause more frequent flooding, higher flood peaks, groundwater drawdown, dry river, and decline of water quality and ecosystem health. There has been an increased public interest in the institutional adoption of LID(Low Impact Development) and GI(Green Infrastructure) techniques to address the adverse impact of IC. The objectives of this study were to construct the modeling site for a samll urban watershed with the Storm Water Management Model(SWMM), and to evaluate the effect of various LID techniques on the control of rainfall runoff processes and non-point pollutant load. The model was calibrated and validated using the field data collected during two flood events on July 17 and August 11, 2009, respectively, and applied to a complex area, where is consist of apartments, school, roads, park, etc. The LID techniques applied to the impervious area were decentralized rainwater management measures such as pervious cover and green roof. The results showed that the increase of perviousness land cover through LID applications decreases the runoff volume and pollutants loading during flood events. In particular, applications of pervious pavement for parking lots and sidewalk, green roof, and their combinations reduced the total volume of runoff by 15~61 % and non-point pollutant loads by TSS 22~72 %, BOD 23~71 %, COD 22~71 %, TN 15~79 %, TP 9~64 % in the study site.

The Consideration about Heavy Metal Contamination of Room and Worker in a Workshop (공작실에서 실내 및 작업종사자의 중금속 오염도에 관한 고찰)

  • Kim Jeong-Ho;Kim Gha-Jung;Kim Sung-Ki;Bea Suk-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.87-94
    • /
    • 2005
  • Purpose : Heavy metal use when producing the block from the workshop. At this time, production of heavy metal dust and fume gives risk in human. This like heavy metal to improve seriousness through measurement and analysis. And by the quest in solution is purpose of this thesis. Materials and Methods : Organization is Inductively Coupled Plasma Atomic Emission Spectrometer, and the object is Deajeon city 4 workshops in university hospital radiation oncology (Bismuth, Lead, Tin and cadmium). Method is the ppb the pumping it does at unit, comparison analysis. And the Calculation heavy metal standard level in air through heavy metal standard level in body and blood, so Heavy metal temporary standard set. Results : Subterranean existence room air quality the administration laws appointed Lead and Cadmium's exposure recommend that it is $3{\mu}g/m^3\;and\;2{\mu}g/m^3$. And Bismuth and Tin decides $7{\mu}g/m^3\;and\;6{\mu}g/m^3$ through standard level in air heavy metal and standard level in body and blood. Heavy metal measurement level of workshops in 4 university hospital Daejeon city compares with work existence and nonexistence. On work nonexistence almost measurement level is below the recommend level. But work existence case express high level. Also consequently in composition ratio of the block is continuous with the detection ratio. Conclusion : Worker's heavy metal contamination imbrued serious for solution founds basic part. In hospital may operation on local air exhauster and periodical efficiency check, protector offer, et al. And worker have a correct understanding part of heavy metal contamination, and have continuous interest, health control. Finally, learned society sphere administer to establishment standard level and periodical measurement. And it founds basic solution plan of periodical special health checkup.

  • PDF

Analysis of the Dose Distribution of Moving Organ using a Moving Phantom System (구동팬텀 시스템에 의한 움직이는 장기의 선량분포 분석)

  • Kim, Yon-Lae;Park, Byung-Moon;Bae, Yong-Ki;Kang, Min-Young;Lee, Gui-Won;Bang, Dong-Wan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.2
    • /
    • pp.81-87
    • /
    • 2006
  • Purpose: Few researches have been peformed on the dose distribution of the moving organ for radiotherapy so far. In order to simulate the organ motion caused by respiratory function, multipurpose phantom and moving device was used and dosimetric measurements for dose distribution of the moving organs were conducted in this study. The purpose of our study was to evaluate how dose distributions are changed due to respiratory motion. Materials and Methods: A multipurpose phantom and a moving device were developed for the measurement of the dose distribution of the moving organ due to respiratory function. Acryl chosen design of the phantom was considered the most obvious choice for phantom material. For construction of the phantom, we used acryl and cork with density of $1.14g/cm^3,\;0.32g/cm^3$ respectively. Acryl and cork slab in the phantom were used to simulate the normal organ and lung respectively. The moving phantom system was composed of moving device, moving control system, and acryl and cork phantom. Gafchromic film and EDR2 film were used to measure dose ditrbutions. The moving device system may be driven by two directional step motors and able to perform 2 dimensional movements (x, z axis), but only 1 dimensional movement(z axis) was used for this study. Results: Larger penumbra was shown in the cork phantom than in the acryl phantom. The dose profile and isodose curve of Gafchromic EBT film were not uniform since the film has small optical density responding to the dose. As the organ motion was increased, the blurrings in penumbra, flatness, and symmetry were increased. Most of measurements of dose distrbutions, Gafchromic EBT film has poor flatness and symmetry than EDR2 film, but both penumbra distributions were more or less comparable. Conclusion: The Gafchromic EBT film is more useful as it does not need development and more radiation dose could be exposed than EDR2 film without losing film characteristics. But as response of the optical density of Gafchromic EBT film to dose is low, beam profiles have more fluctuation at Gafchromic EBT. If the multipurpose phantom and moving device are used for treatment Q.A, and its corrections are made, treatment quality should be improved for the moving organs.

  • PDF

Studies on the Grape Wines (part II) - On the browing methods and the aging (포도주에 관한 연구 (제2보) - 포도주 양조방법 및 숙성촉진에 대하여)

  • Kim, Chan Jo;Kim, Seong Yeul;Oh, Man Jin
    • Korean Journal of Agricultural Science
    • /
    • v.2 no.2
    • /
    • pp.451-462
    • /
    • 1975
  • The qualities of the grape wines brewed with the varieties of Steuben, Muscat Bailey A, Merlot, Campbell Early and Alden were compared, and studied the mashing methods of the wine with a variety of Muscat Bailey A. and then investigated the aging effects of ultrasonic wave and the baking treatments on the new wines. The results obtained were as follows. 1. Extracts of the new wines brewed with the varieties of Steuben and Alden were 2.55 and 1.88 per cent respectively and the color densities of the wines with Merlot and Alden were 3.5 and 1.05 (optical density) respectively, and the other contents were not significantly different beween varieties. On the Otherhand, the results of sensory test showed that the order of favorite was the wines brewed with Steuben, Muscat Bailey A, Merlot, Campbell Early and Alden. 2. The effect of pasteurization ($55^{\circ}C$, 20 min.) on the inhibition of the growth of undesirable microorganism was appeared almost the same degree as the case of sulfiting (100 ppm), and the pasteurized must was more dense in color but slightly turbid than the case of sulfiting. 3. Glucose syrup was in adequate as a materials for supplemental sugar, and the quality of the new wine further fermented the free-run wine added the alcohol to be a constant alcohol content was almost the same as that of control. 4. Baking at $50^{\circ}C$. for 50 days to t he new wine from 0.45 to 0.65 per cent, and color density was also thicken from 2.8 to 3.17 (O. D). 5. Baking at $40^{\circ}C$. for 50days to the new wine brewed with Muscat Bailey A, increased the ester content of the wine from 0.37 to 0.65 per cent and color density was-also thicken from 3. to 4.2 (O.D). 6. Ultrasonic wave (150 watt, 20Kc) treatment for 10 hours to the new wine brewed with Muscat Bailey A, increased the ester content of the wine from 0.37 to 0.47 per cent.

  • PDF

Laparoscopy Assisted versus Open Distal Gastrectomy with D2 Lymph Node Dissection for Advanced Gastric Cancer: Design and Rationale of a Phase II Randomized Controlled Multicenter Trial (COACT 1001)

  • Nam, Byung Ho;Kim, Young-Woo;Reim, Daniel;Eom, Bang Wool;Yu, Wan Sik;Park, Young Kyu;Ryu, Keun Won;Lee, Young Joon;Yoon, Hong Man;Lee, Jun Ho;Jeong, Oh;Jeong, Sang Ho;Lee, Sang Eok;Lee, Sang Ho;Yoon, Ki Young;Seo, Kyung Won;Chung, Ho Young;Kwon, Oh Kyoung;Kim, Tae Bong;Lee, Woon Ki;Park, Seong Heum;Sul, Ji-Young;Yang, Dae Hyun;Lee, Jong Seok
    • Journal of Gastric Cancer
    • /
    • v.13 no.3
    • /
    • pp.164-171
    • /
    • 2013
  • Purpose: Laparoscopy-assisted distal gastrectomy for early gastric cancer has gained acceptance and popularity worldwide. However, laparoscopy-assisted distal gastrectomy for advanced gastric cancer is still controversial. Therefore, we propose this prospective randomized controlled multi-center trial in order to evaluate the safety and feasibility of laparoscopy assisted D2-gastrectomy for advanced stage gastric cancer. Materials and Methods: Patients undergoing distal gastrectomy for advanced gastric cancer staged cT2/3/4 cN0/1/2/3a cM0 by endoscopy and computed tomography are eligible for enrollment after giving their informed consent. Patients will be randomized either to laparoscopyassisted distal gastrectomy or open distal gastrectomy. Sample size calculation revealed that 102 patients are to be included per treatment arm. The primary endpoint is the non-compliance rate of D2 dissection; relevant secondary endpoints are three-year disease free survival, surgical and postoperative complications, hospital stay and unanimity rate of D2 dissection evaluated by reviewing the intraoperative video documentation. Discussion: Oncologic safety is the major concern regarding laparoscopy-assisted distal gastrectomy for advanced gastric cancer. Therefore, the non-compliance rate of clearing the N2 area was chosen as the most important parameter for the technical feasibility of the laparoscopic procedure. Furthermore, surgical quality will be carefully reviewed, that is, three independent experts will review the video records and score with a check list. For a long-term result, disease free survival is considered a secondary endpoint for this trial. This study will offer promising evidence of the feasibility and safety of Laparoscopy-assisted distal gastrectomy for advanced gastric cancer. Trial Registration: NCT01088204 (international), NCCCTS-09-448 (Korea).

The Evaluation of Radioimmunoassay kits for Insulin (Insulin 측정용 방사면역측정법 시약의 평가)

  • Shin, Yong Hwan;Kim, Yun Hyun;Lee, Il Kyu;Kim, Ji Young;Seok, Jae Dong;Shin, Suk Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.149-155
    • /
    • 2012
  • Purpose : Serum insulin levels are useful indicator which of reflecting the function of insulin secretion in pancreatic ${\beta}$ cell and diagnosis of diabetes, differentiating the cause of impaired glucose tolerance. Insulin measurement kits have shown some differences in many ways such as test methods as well as quality control. The purpose of this study was to evaluate the diagnostic performance of seven manufacturing companies commercial kits. Materials and Methods : The values of insulin measured by three manufacturing companies (Biosource, Siemens, TFB) with 59 samples in August 2009 were compared with those measured by four manufacturing companies (Immunotech, Izotope, BNIBT, Cisbio) with 68 samples in December 2011. We evaluated precision, recovery rate, dilution test and correlation of serum insulin measurement using seven manufacturing company kits. Statistical program SPSS 12.0 was used for the verification of results. Results : The coefficients variation of the precision on all seven different kits were showed within 5.0%. Recovery rate of Biosource, Siemens, TFB kits on three different levels showed 94.2~103.7%, 99.0~104.6%, 99.7~107.6% respectively. Immunotech, Izotope, BNIBT, Cisbio were 93.5~99.1%, 91.4~99.1%, 99.2~131.0%, 84.8~102.3% respectively. There was strong correlation between the measurement of insulin by Biosource kit and that by two commercial kits, Siemens (R2=0.96), TFB (R2=0.99). There was good correlation between the measurement of insulin by TFB kit and that by three commercial kits, Immunotech (R2=0.97), Izotope (R2=0.96), Cisbio (R2=0.97). In the dilution test performed with more than 200 ${\mu}IU/ml$ high concentration samples, samples with diabetes correctly was measured in all seven manufacturing kits. However, as measured with insulinoma samples TFB, Siemens, Izotope, Cisbio kits were correctly measured, but Biosource and Immunotech kits were measured 47.4 ${\mu}IU/ml$, 72.3 ${\mu}IU/ml$, respectively. Conclusion : Serum Insulin radioimmunoassay kits were showed excellent precision, correlation and good recovery rate. However, some kits were not measured correctly in the high concentration insulin values. when selecting a kit should be considered many factors that cost effectiveness, compatible for automation equipment, high performance kit, the environment for each laboratory such as reaction time and reporting time.

  • PDF

Characteristics of Pop-rice and Rice Tea Using Black Sticky Rice with Giant Embryo (흑찰거대배아미를 이용한 팝라이스와 흑미차의 품질 특성)

  • Han, Sang-Ik;Seo, Woo Duck;Na, Ji-Eun;Park, Ji-Young;Park, Dong-Soo;Cho, Jun-Hyun;Lee, Jong-Hee;Seo, Kyung-Hye;Sim, Eun-Yeong;Nam, Min-Hee
    • Journal of Life Science
    • /
    • v.25 no.1
    • /
    • pp.68-74
    • /
    • 2015
  • Recently developed black waxy rice with a giant embryo ('Nunkeunheukchal', BGE) was selected and processed to produce high quality nutritional food. BGE contains high levels of several phytochemicals with antioxidant activities, as well as other reported health beneficial properties. In addition, the giant embryo has high protein, lipid, and amino acids contents. Within the free amino acids, ${\gamma}$-aminobutyric acid (GABA), a major inhibitory neurotransmitter, has long been used for treating the aftereffects of brain injuries and stroke. A method for manufacturing pop-rice and black rice tea by popping process in BGE is provided to increase a taste, nutrition and functionality. The produced 'pop-rice' showed increased protein (11.3%) and lipid (3.7%) contents compared with control variety, IB ('Ilmibyeo'). In addition, melanoidin related products, polyphenol and functional amino acid contents were increased by the popping process. Pop-rice tea made of BGE showed the highest extraction of total sugar, glucose, raffinose and sucrose (4 times higher than brown rice) by hot water. Scavenging activity ($SC_{50}$) of processed BGE rice powder showed strong antioxidative activity of 0.24 mg/ml using DPPH and 1.82 mg/ml using ABTs method. Thereafter, these results suggested that the popping processed rice of BGE could be one of the promising materials for healthy food development.

Quality Changes in Oyster Mushrooms during Modified Atmosphere Storage as Affected by Temperatures and Packaging Materials (저장 온도와 포장재에 따른 느타리버섯의 MA 저장 중 품질변화)

  • Choi, Mi-Hee;Kim, Gun-Hee
    • Korean Journal of Food Science and Technology
    • /
    • v.35 no.6
    • /
    • pp.1079-1085
    • /
    • 2003
  • Modified atmosphere packaging was applied to oyster mushrooms (Pleurotus ostreatus) to study the effect of storage temperatures and packaging materialso. Whole mushrooms (200g) were package with polyethylene film $(PE,\;60{\mu}m\;thickness)$, ethylene vinyl acetate (EVA), or ceramic film (containing 5% zeolite) and stored at 0, 5, 10 and $20^{\circ}C$. Weight loss, color, firmness, gas composition $(O_2,\;CO_2)$ inside the film package and ethanol content in the tissue of MA packaged mushrooms were examined. Mushroom that were packed unwrapped in a conventional hardboard box (2 kg) lost marketability at a very early stage of storage due to weight loss, shrinkage, browning, and spore formation. During storage, film packaging prevented or retarded the deterioration of the mushrooms in the aspects of appearance, texture, and discoloration. Firmness slightly decreased with storage time. Total color difference was much higher in the control than in the film-packaged mushroom and rapidly increased at the early of storage. Correlation analysis showed a high correlation between total color difference and b values. These results were characterized by the reduced respiration rate resulting from elevated carbon dioxide and reduced oxygen levels in the package. At all storage temperatures, ethanol content in the tissue increased slightly at the early part of storage and rose considerably towards the end of the storage period. Ethanol content in the oyster mushrooms was higher in the stipe than in pileus tissues. The shelf life of the oyster mushrooms was about $8{\sim}11$ days at $0^{\circ}C$, about $4{\sim}6$ day at $5^{\circ}C$, about $2{\sim}3$ days at $10^{\circ}C$, and about $1{\sim}2$ days at $20^{\circ}C$.

GafChromic Film Dosimetry for Stereotactic Radiosurgery with a Linear Accelerator (선형가속기를 이용한 정위방사선 치료 시 GafChromic Film을 이용한 선량측정)

  • Han Seung Hee;Cho Byung Chul;Park Suk Won;Oh Do Hoon;Park Hee Chul;Bae Hoon Sik
    • Radiation Oncology Journal
    • /
    • v.21 no.2
    • /
    • pp.167-173
    • /
    • 2003
  • Purpose: The purpose of this study was to evaluate whether a GafChromic film applied to stereotactic radiosurgery with a linear accelerator could provide information on the value for acceptance testing and quality control on the absolute dose and relative dose measurements and/or calculation of treatment planning system. Materials and methods: A spherical acrylic phantom, simulating a patient's head, was constructed from three points. The absolute and relative dose distributions could be measured by inserting a GafChromic film into the phantom. We tested the use of a calibrated GafChromic film (MD-55-2, Nuclear Associate, USA) for measuring the optical density. These measurements were achieved by irradiating the films with a dose of 0-112 Gy employing 6 MV photon. To verify the accuracy of the prescribed dose delivery to a target isocenter using a five arc beams (irradiated in 3 Gy per one beam) setup, calculated by the Linapel planning system the absolute dose and relative dose distribution using a GafChromic film were measured. All the irradiated films were digitized with a Lumiscan 75 laser digitizer and processed with the RIT113 film dosimetry system. Results: We verified the linearity of the Optical Density of a MD-55-2 GafChromic film, and measured the depth dose profile of the beam. The absolute dose delivered to the target was close to the prescribed dose of Linapel within an accuracy for the GafChromic film dosimetry (of $\pm$3$\%$), with a measurement uncertainty of $\pm$1 mm for the 50$\~$90$\%$ isodose lines. Conclusion: Our results have shown that the absolute dose and relative dose distribution curves obtained from a GafChromic film can provide information on the value for acceptance. To conclude the GafChromic flim is a convenient and useful dosimetry tool for linac based radiosurgery.