• Title/Summary/Keyword: Quality control materials

Search Result 1,115, Processing Time 0.033 seconds

Analysis of the Dose Distribution of Moving Organ using a Moving Phantom System (구동팬텀 시스템에 의한 움직이는 장기의 선량분포 분석)

  • Kim, Yon-Lae;Park, Byung-Moon;Bae, Yong-Ki;Kang, Min-Young;Lee, Gui-Won;Bang, Dong-Wan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.2
    • /
    • pp.81-87
    • /
    • 2006
  • Purpose: Few researches have been peformed on the dose distribution of the moving organ for radiotherapy so far. In order to simulate the organ motion caused by respiratory function, multipurpose phantom and moving device was used and dosimetric measurements for dose distribution of the moving organs were conducted in this study. The purpose of our study was to evaluate how dose distributions are changed due to respiratory motion. Materials and Methods: A multipurpose phantom and a moving device were developed for the measurement of the dose distribution of the moving organ due to respiratory function. Acryl chosen design of the phantom was considered the most obvious choice for phantom material. For construction of the phantom, we used acryl and cork with density of $1.14g/cm^3,\;0.32g/cm^3$ respectively. Acryl and cork slab in the phantom were used to simulate the normal organ and lung respectively. The moving phantom system was composed of moving device, moving control system, and acryl and cork phantom. Gafchromic film and EDR2 film were used to measure dose ditrbutions. The moving device system may be driven by two directional step motors and able to perform 2 dimensional movements (x, z axis), but only 1 dimensional movement(z axis) was used for this study. Results: Larger penumbra was shown in the cork phantom than in the acryl phantom. The dose profile and isodose curve of Gafchromic EBT film were not uniform since the film has small optical density responding to the dose. As the organ motion was increased, the blurrings in penumbra, flatness, and symmetry were increased. Most of measurements of dose distrbutions, Gafchromic EBT film has poor flatness and symmetry than EDR2 film, but both penumbra distributions were more or less comparable. Conclusion: The Gafchromic EBT film is more useful as it does not need development and more radiation dose could be exposed than EDR2 film without losing film characteristics. But as response of the optical density of Gafchromic EBT film to dose is low, beam profiles have more fluctuation at Gafchromic EBT. If the multipurpose phantom and moving device are used for treatment Q.A, and its corrections are made, treatment quality should be improved for the moving organs.

  • PDF

Studies on the Grape Wines (part II) - On the browing methods and the aging (포도주에 관한 연구 (제2보) - 포도주 양조방법 및 숙성촉진에 대하여)

  • Kim, Chan Jo;Kim, Seong Yeul;Oh, Man Jin
    • Korean Journal of Agricultural Science
    • /
    • v.2 no.2
    • /
    • pp.451-462
    • /
    • 1975
  • The qualities of the grape wines brewed with the varieties of Steuben, Muscat Bailey A, Merlot, Campbell Early and Alden were compared, and studied the mashing methods of the wine with a variety of Muscat Bailey A. and then investigated the aging effects of ultrasonic wave and the baking treatments on the new wines. The results obtained were as follows. 1. Extracts of the new wines brewed with the varieties of Steuben and Alden were 2.55 and 1.88 per cent respectively and the color densities of the wines with Merlot and Alden were 3.5 and 1.05 (optical density) respectively, and the other contents were not significantly different beween varieties. On the Otherhand, the results of sensory test showed that the order of favorite was the wines brewed with Steuben, Muscat Bailey A, Merlot, Campbell Early and Alden. 2. The effect of pasteurization ($55^{\circ}C$, 20 min.) on the inhibition of the growth of undesirable microorganism was appeared almost the same degree as the case of sulfiting (100 ppm), and the pasteurized must was more dense in color but slightly turbid than the case of sulfiting. 3. Glucose syrup was in adequate as a materials for supplemental sugar, and the quality of the new wine further fermented the free-run wine added the alcohol to be a constant alcohol content was almost the same as that of control. 4. Baking at $50^{\circ}C$. for 50 days to t he new wine from 0.45 to 0.65 per cent, and color density was also thicken from 2.8 to 3.17 (O. D). 5. Baking at $40^{\circ}C$. for 50days to the new wine brewed with Muscat Bailey A, increased the ester content of the wine from 0.37 to 0.65 per cent and color density was-also thicken from 3. to 4.2 (O.D). 6. Ultrasonic wave (150 watt, 20Kc) treatment for 10 hours to the new wine brewed with Muscat Bailey A, increased the ester content of the wine from 0.37 to 0.47 per cent.

  • PDF

Laparoscopy Assisted versus Open Distal Gastrectomy with D2 Lymph Node Dissection for Advanced Gastric Cancer: Design and Rationale of a Phase II Randomized Controlled Multicenter Trial (COACT 1001)

  • Nam, Byung Ho;Kim, Young-Woo;Reim, Daniel;Eom, Bang Wool;Yu, Wan Sik;Park, Young Kyu;Ryu, Keun Won;Lee, Young Joon;Yoon, Hong Man;Lee, Jun Ho;Jeong, Oh;Jeong, Sang Ho;Lee, Sang Eok;Lee, Sang Ho;Yoon, Ki Young;Seo, Kyung Won;Chung, Ho Young;Kwon, Oh Kyoung;Kim, Tae Bong;Lee, Woon Ki;Park, Seong Heum;Sul, Ji-Young;Yang, Dae Hyun;Lee, Jong Seok
    • Journal of Gastric Cancer
    • /
    • v.13 no.3
    • /
    • pp.164-171
    • /
    • 2013
  • Purpose: Laparoscopy-assisted distal gastrectomy for early gastric cancer has gained acceptance and popularity worldwide. However, laparoscopy-assisted distal gastrectomy for advanced gastric cancer is still controversial. Therefore, we propose this prospective randomized controlled multi-center trial in order to evaluate the safety and feasibility of laparoscopy assisted D2-gastrectomy for advanced stage gastric cancer. Materials and Methods: Patients undergoing distal gastrectomy for advanced gastric cancer staged cT2/3/4 cN0/1/2/3a cM0 by endoscopy and computed tomography are eligible for enrollment after giving their informed consent. Patients will be randomized either to laparoscopyassisted distal gastrectomy or open distal gastrectomy. Sample size calculation revealed that 102 patients are to be included per treatment arm. The primary endpoint is the non-compliance rate of D2 dissection; relevant secondary endpoints are three-year disease free survival, surgical and postoperative complications, hospital stay and unanimity rate of D2 dissection evaluated by reviewing the intraoperative video documentation. Discussion: Oncologic safety is the major concern regarding laparoscopy-assisted distal gastrectomy for advanced gastric cancer. Therefore, the non-compliance rate of clearing the N2 area was chosen as the most important parameter for the technical feasibility of the laparoscopic procedure. Furthermore, surgical quality will be carefully reviewed, that is, three independent experts will review the video records and score with a check list. For a long-term result, disease free survival is considered a secondary endpoint for this trial. This study will offer promising evidence of the feasibility and safety of Laparoscopy-assisted distal gastrectomy for advanced gastric cancer. Trial Registration: NCT01088204 (international), NCCCTS-09-448 (Korea).

The Evaluation of Radioimmunoassay kits for Insulin (Insulin 측정용 방사면역측정법 시약의 평가)

  • Shin, Yong Hwan;Kim, Yun Hyun;Lee, Il Kyu;Kim, Ji Young;Seok, Jae Dong;Shin, Suk Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.149-155
    • /
    • 2012
  • Purpose : Serum insulin levels are useful indicator which of reflecting the function of insulin secretion in pancreatic ${\beta}$ cell and diagnosis of diabetes, differentiating the cause of impaired glucose tolerance. Insulin measurement kits have shown some differences in many ways such as test methods as well as quality control. The purpose of this study was to evaluate the diagnostic performance of seven manufacturing companies commercial kits. Materials and Methods : The values of insulin measured by three manufacturing companies (Biosource, Siemens, TFB) with 59 samples in August 2009 were compared with those measured by four manufacturing companies (Immunotech, Izotope, BNIBT, Cisbio) with 68 samples in December 2011. We evaluated precision, recovery rate, dilution test and correlation of serum insulin measurement using seven manufacturing company kits. Statistical program SPSS 12.0 was used for the verification of results. Results : The coefficients variation of the precision on all seven different kits were showed within 5.0%. Recovery rate of Biosource, Siemens, TFB kits on three different levels showed 94.2~103.7%, 99.0~104.6%, 99.7~107.6% respectively. Immunotech, Izotope, BNIBT, Cisbio were 93.5~99.1%, 91.4~99.1%, 99.2~131.0%, 84.8~102.3% respectively. There was strong correlation between the measurement of insulin by Biosource kit and that by two commercial kits, Siemens (R2=0.96), TFB (R2=0.99). There was good correlation between the measurement of insulin by TFB kit and that by three commercial kits, Immunotech (R2=0.97), Izotope (R2=0.96), Cisbio (R2=0.97). In the dilution test performed with more than 200 ${\mu}IU/ml$ high concentration samples, samples with diabetes correctly was measured in all seven manufacturing kits. However, as measured with insulinoma samples TFB, Siemens, Izotope, Cisbio kits were correctly measured, but Biosource and Immunotech kits were measured 47.4 ${\mu}IU/ml$, 72.3 ${\mu}IU/ml$, respectively. Conclusion : Serum Insulin radioimmunoassay kits were showed excellent precision, correlation and good recovery rate. However, some kits were not measured correctly in the high concentration insulin values. when selecting a kit should be considered many factors that cost effectiveness, compatible for automation equipment, high performance kit, the environment for each laboratory such as reaction time and reporting time.

  • PDF

Characteristics of Pop-rice and Rice Tea Using Black Sticky Rice with Giant Embryo (흑찰거대배아미를 이용한 팝라이스와 흑미차의 품질 특성)

  • Han, Sang-Ik;Seo, Woo Duck;Na, Ji-Eun;Park, Ji-Young;Park, Dong-Soo;Cho, Jun-Hyun;Lee, Jong-Hee;Seo, Kyung-Hye;Sim, Eun-Yeong;Nam, Min-Hee
    • Journal of Life Science
    • /
    • v.25 no.1
    • /
    • pp.68-74
    • /
    • 2015
  • Recently developed black waxy rice with a giant embryo ('Nunkeunheukchal', BGE) was selected and processed to produce high quality nutritional food. BGE contains high levels of several phytochemicals with antioxidant activities, as well as other reported health beneficial properties. In addition, the giant embryo has high protein, lipid, and amino acids contents. Within the free amino acids, ${\gamma}$-aminobutyric acid (GABA), a major inhibitory neurotransmitter, has long been used for treating the aftereffects of brain injuries and stroke. A method for manufacturing pop-rice and black rice tea by popping process in BGE is provided to increase a taste, nutrition and functionality. The produced 'pop-rice' showed increased protein (11.3%) and lipid (3.7%) contents compared with control variety, IB ('Ilmibyeo'). In addition, melanoidin related products, polyphenol and functional amino acid contents were increased by the popping process. Pop-rice tea made of BGE showed the highest extraction of total sugar, glucose, raffinose and sucrose (4 times higher than brown rice) by hot water. Scavenging activity ($SC_{50}$) of processed BGE rice powder showed strong antioxidative activity of 0.24 mg/ml using DPPH and 1.82 mg/ml using ABTs method. Thereafter, these results suggested that the popping processed rice of BGE could be one of the promising materials for healthy food development.

Quality Changes in Oyster Mushrooms during Modified Atmosphere Storage as Affected by Temperatures and Packaging Materials (저장 온도와 포장재에 따른 느타리버섯의 MA 저장 중 품질변화)

  • Choi, Mi-Hee;Kim, Gun-Hee
    • Korean Journal of Food Science and Technology
    • /
    • v.35 no.6
    • /
    • pp.1079-1085
    • /
    • 2003
  • Modified atmosphere packaging was applied to oyster mushrooms (Pleurotus ostreatus) to study the effect of storage temperatures and packaging materialso. Whole mushrooms (200g) were package with polyethylene film $(PE,\;60{\mu}m\;thickness)$, ethylene vinyl acetate (EVA), or ceramic film (containing 5% zeolite) and stored at 0, 5, 10 and $20^{\circ}C$. Weight loss, color, firmness, gas composition $(O_2,\;CO_2)$ inside the film package and ethanol content in the tissue of MA packaged mushrooms were examined. Mushroom that were packed unwrapped in a conventional hardboard box (2 kg) lost marketability at a very early stage of storage due to weight loss, shrinkage, browning, and spore formation. During storage, film packaging prevented or retarded the deterioration of the mushrooms in the aspects of appearance, texture, and discoloration. Firmness slightly decreased with storage time. Total color difference was much higher in the control than in the film-packaged mushroom and rapidly increased at the early of storage. Correlation analysis showed a high correlation between total color difference and b values. These results were characterized by the reduced respiration rate resulting from elevated carbon dioxide and reduced oxygen levels in the package. At all storage temperatures, ethanol content in the tissue increased slightly at the early part of storage and rose considerably towards the end of the storage period. Ethanol content in the oyster mushrooms was higher in the stipe than in pileus tissues. The shelf life of the oyster mushrooms was about $8{\sim}11$ days at $0^{\circ}C$, about $4{\sim}6$ day at $5^{\circ}C$, about $2{\sim}3$ days at $10^{\circ}C$, and about $1{\sim}2$ days at $20^{\circ}C$.

GafChromic Film Dosimetry for Stereotactic Radiosurgery with a Linear Accelerator (선형가속기를 이용한 정위방사선 치료 시 GafChromic Film을 이용한 선량측정)

  • Han Seung Hee;Cho Byung Chul;Park Suk Won;Oh Do Hoon;Park Hee Chul;Bae Hoon Sik
    • Radiation Oncology Journal
    • /
    • v.21 no.2
    • /
    • pp.167-173
    • /
    • 2003
  • Purpose: The purpose of this study was to evaluate whether a GafChromic film applied to stereotactic radiosurgery with a linear accelerator could provide information on the value for acceptance testing and quality control on the absolute dose and relative dose measurements and/or calculation of treatment planning system. Materials and methods: A spherical acrylic phantom, simulating a patient's head, was constructed from three points. The absolute and relative dose distributions could be measured by inserting a GafChromic film into the phantom. We tested the use of a calibrated GafChromic film (MD-55-2, Nuclear Associate, USA) for measuring the optical density. These measurements were achieved by irradiating the films with a dose of 0-112 Gy employing 6 MV photon. To verify the accuracy of the prescribed dose delivery to a target isocenter using a five arc beams (irradiated in 3 Gy per one beam) setup, calculated by the Linapel planning system the absolute dose and relative dose distribution using a GafChromic film were measured. All the irradiated films were digitized with a Lumiscan 75 laser digitizer and processed with the RIT113 film dosimetry system. Results: We verified the linearity of the Optical Density of a MD-55-2 GafChromic film, and measured the depth dose profile of the beam. The absolute dose delivered to the target was close to the prescribed dose of Linapel within an accuracy for the GafChromic film dosimetry (of $\pm$3$\%$), with a measurement uncertainty of $\pm$1 mm for the 50$\~$90$\%$ isodose lines. Conclusion: Our results have shown that the absolute dose and relative dose distribution curves obtained from a GafChromic film can provide information on the value for acceptance. To conclude the GafChromic flim is a convenient and useful dosimetry tool for linac based radiosurgery.

Concentration Levels and Distribution Characteristics of Polycyclic Aromatic Hydrocarbons (PAHs) at Ambient Air in Industrial Complex Area (공단지역 대기 중 다환방향족탄화수소화합물(PAHs)의 농도수준 및 분포특성)

  • Jung, Jong-Hyeon;Phee, Young-Gyu;Cho, Sang-Won;Ok, Gon;Shon, Byung-Hyun;Lee, Kwan;Lim, Hyun-Sul
    • Clean Technology
    • /
    • v.17 no.4
    • /
    • pp.379-388
    • /
    • 2011
  • The purpose of this study was to investigate the concentration levels, distribution characteristics and blood concentration of Polycyclic Aromatic Hydrocarbons (PAHs) at ambient air in Industrial Complex Area. The samples were collected at 4 sites in Industrial Complex Area and its vicinities. The result indicated that there was the difference of PAHs concentration as followed local characteristics. The level of average concentration of PAHs in the air in Industrial Complex Area was $14.52{\sim}193.48ng/m^3$. The level of average concentration of six materials with possibility of cancer creation was $1.65{\sim}13.44ng/m^3$. The concentrations of PAHs were generally low, but Jechul-dong is considered an area where consistent monitoring of PAHs is required. In addition, benzo(a)pyrene was detected in every atmospheric sample, however the concentration was not high. The level of concentration of benzo(a)pyrene in the air in the Jechul-dong was $2.89ng/m^3$. But, the concentration of the PAHs in Jechul-dong showed that the Benzo(a)pyrene concentration is above $1ng/m^3$ of air quality standard(EU). The results of the concentration level of PAHs in the blood from 240 persons who were exposed directly were surveyed, it was $1.12{\sim}11.45ng/m^3$ for man and $1.20{\sim}26.89ng/m^3$ for woman. It was indicated that the difference between the genders was very little. The accumulation inside human was anticipated as the PAHs concentration in the blood for the aged was very high. Industrial Complex Area and its vicinities are an area which has been greatly influenced by PAHs and environmental contaminants. It is necessary to control the emission sources of PAHs and to construct an observation system at Industrial Complex Area from now on. It is time to reduce the risk factors for health and environmental disease to protect the health of resident in Industrial Complex Area and its vicinities.

Evaluation of Tumor Registry Validity in Samsung Medical Center Radiation Oncology Department (삼성서울병원 방사선종양학과 종양등록 정보의 타당도 평가)

  • Park Won;Huh Seung Jae;Kim Dae Yong;Shin Seong Soo;Ahn Yong Chan;Lim Do Hoon;Kim Seonwoo
    • Radiation Oncology Journal
    • /
    • v.22 no.1
    • /
    • pp.33-39
    • /
    • 2004
  • Purpose : A tumor registry system for the patients treated by radiotherapy at Samsung Medical Center since the opening of a hospital at 1994 was employed. In this study, the tumor registry system was introduced and the validity of the tumor registration was analyzed. Materials and Methods: The tumor registry system was composed of three parts: patient demographic, diagnostic, and treatment Information. All data were input in a screen using a mouse only. Among the 10,000 registered cases in the tumor registry system until Aug, 2002, 199 were randomly selected and their registration data were compared with the patients' medical records. Results : Total input errors were detected on 15 cases (7.5%). There were 8 error items In the part relating to diagnostic Information: tumor site 3, pathology 2, AJCC staging 2 and performance status 1. In the part relating to treatment information there were 9 mistaken items: combination treatment 4, the date of initial treatment 3 and radiation completeness 2. According to the assignment doctor, the error ratio was consequently variable. The doctors who 010 no double-checks showed higher errors than those that 010 (15.6%:3.7%). Conclusion: Our tumor registry had errors within 2% for each Item. Although the overall data qualify was high, further improvement might be achieved through promoting sincerity, continuing training, periodic validity tests and keeping double-checks. Also, some items associated with the hospital Information system will be input automatically In the next step.

The Effects of Medicinal Herb-made Sikhe on Damage and Lipid Levels of Liver in Rats Fed High-cholesterol Diets (한약제 추출물로 제조된 식혜가 고지방식이에 의한 흰주의 간 손상과 간 지질 함량에 미치는 영향)

  • Park, Hyun-Suk;Yang, Kyung-Chun;Yang, Kyung-Mi
    • Journal of Life Science
    • /
    • v.19 no.8
    • /
    • pp.1104-1111
    • /
    • 2009
  • This study was conducted to evaluate the effect of Sikhe made by medicinal herb on the functional level of liver. Water extract I (12.9% W/W) and II (25.8% W/W) were obtained from medicinal materials: Caragana Sinica, Glycyrrhiza uralensis, Atractylodes rhizoma alba, Atractylodes rhizoma alba, Crataegus pinnatifida, Paeonia lactiflora Pasll., Hordeum vulgare Linne, Oryza sativa Linne, ginger, peer and jujube. Experimental groups were divided into the control diet group (C), high fat diet group (HF), high fat diet treated with 5% extract I group (HFE I ) and high fat diet treated with 5% extract II group (HFE II). In sensory evaluation, overall quality scores associated with color, aroma, flavor and taste were significantly higher in water extract II than in water extract 1. After investigating functional and lipid levels of livers in rats, we found that the administration of water extract I or water extract II to the high fat diet group (HF) did not affect the gain of body weight but mildly reduced GOT or GPT activity in the high diet group. Moreover, administration of these medicinal herbal extracts significantly decreased the levels of total lipid, triglyceride and total cholesterol in the high fat diet group (HF). However, administration of these medicinal herbal extracts did not affect the level of phospholipid. In conclusion, as Sikhe made by medicinal herb slightly decreased the activity of GOT or GPT and amount of lipid in liver, prevention against high fat diet is thought to be important for liver protection.