• Title/Summary/Keyword: Quality control device

Search Result 435, Processing Time 0.027 seconds

Development of Electrical Safety Evaluation Method about PEMFC 1kW (가정용연료전지 전기적 안전성 평가 기법 개발)

  • Han, Woonki;Park, Chaneum;Jung, Jinsu;Ko, Woonsik
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.99-99
    • /
    • 2011
  • Fuel cell systems are a completely different form of electricity source that has been used so far and is an aggregation of multiple technologies with multidisciplinary features that can be operated safely only when gas and electrical safety are being considered. Since fuel cells generate through electrochemical reactions there are difficulties in ensuring electricity safety, power quality assessment, effective control and reliability standards for system faults using conventional inspection techniques and even though they are necessary as a primary means for reduction of CO2 owing to the Climate Convention, electrical safety assessment and measures are required for the prevention of faults in residential facilities. Although small-scaled distributed power supplies can be utilized as important means of peak control and energy management measures, research is required for observing the effects on the system and the development of inspection technology to ensure stable operation, and the electrical safety of residential fuel cell systems need to be assessed and the problems derived for establishing electrical safety standards. From the year 2002, Japan has established laws on technical safety standards and development and rules on the product specifications and standards for the industrialization of hydrogen fuel cells. Also, a lot of effort have been made for the commercialization of fuel cells by building one-stop certification services. Internationally, the IEC TC 105 has established international standards based on fuel cells. In order to protect the national interest, the country should be able to respond accordingly meet global standards. In fact, in Korea, to comply with the international trend, Korea Energy Management Corporation is establishing a certified agenda for fuel cells and Korean Agency for Technology and Standards is enacting technical standards for fuel cells. The current terms of fuel cells are that research has been focused more on the quality and performance of manufactured products rather than stable power operation and maintenance over time. In this paper, by considering the household fuel cell as a power device, the safety standards of the fuel cell system for a reliable operation with the existing power system is being proposed.

  • PDF

Development of a Precision Management System for Quality Control of Progressive die (프로그레시브 금형의 품질관리를 위한 정도관리 시스템 개발)

  • Park, Jong-Nam
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.9
    • /
    • pp.5434-5439
    • /
    • 2014
  • The surface management of metals was performed with a tool microscope or surface roughness measurement instruments. These methods were not efficient for checking the surface status of the die in the production field. For this reason, an analysis system or measurement system to monitor the wear, defects and surface status as a die ages is required. This study, developed surface analysis software for automatic analysis and standardization of a die or processed products. Software was designed to measure the basic features, such as circles, dots, and lines. The captured images were rendered as three-dimensional representations so that the depth of the grooves on the die and segmental profiles could be estimated. As a result of experimental analysis, the surface roughness was measured with an accuracy more than 93.2%, and the maximum deviation in the surface roughness for the brightness of the lighting was within $3{\mu}m$. The confidence in the device's precision was assured. These results show quality control through efficient surface analysis.

Developing Customized Phantom for Korean Bone Density Using 3D Printing (3D 프린팅을 이용한 한국인 골밀도 맞춤 팬텀 개발)

  • Lee, Junho;Choi, Kwan-Yong;Choi, Jae-Ho
    • Journal of radiological science and technology
    • /
    • v.42 no.3
    • /
    • pp.223-229
    • /
    • 2019
  • In order to reduce the radiation exposure dose of the patient and to obtain accurate diagnosis results, the quality control of the diagnostic radiation generator must be conducted periodically In particular, bone density test equipment could be influenced by many factors, and it is far more important because inaccurate measurement would eventually affect the result value. However, the cross-correction phantom of DXA equipment is poorly penetrated due to lack of awareness of the industry and the high cost. Therefore, this study developed a BMD phantom using a 3D printer and Korean BMD phantom with low cost by cross analyzing Korean BMD value from The Korean National Health and Nutrition Examination Survey and evaluated it. The L1, L2, and L3 BMD values of phantoms produced with the 3D printer were measured to be $0.887{\pm}0.006g/cm^2$, $0.927{\pm}0.006g/cm^2$, and $0.960{\pm}0.005g/cm^2$, at 215 mm height and $0.882{\pm}0.011g/cm^2$, $0.914{\pm}0.005g/cm^2$, $0.933{\pm}0.008g/cm^2$ at 155 mm height displaying statistically significant relevance. The result suggests that a proper quality control and cross calibration of DXA device be possible and expected to be an essential data for various medical phantom manufacture development using 3D printer.

Development of Integrated Wireless Sensor Network Device with Mold for Measurement of Concrete Temperature (콘크리트 온도 측정을 위한 거푸집 일체형 무선센서네트워크 장치 개발)

  • Lee, Sung Bok;Park, Seong Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.5
    • /
    • pp.129-136
    • /
    • 2012
  • Temperature of fresh concrete can be effectively used to predict the strength of concrete being cured and make an informed decision for stripping the molds. A hygrothermograph and thermo-couple sensors that require an extensive wiring have been applied to measure a temperature of concrete at the early stage of the curing process on site. However, these methods have limits to provide the temperature data in real time due to harsh working environment including frequent cutting of wires. Therefore, this study is aiming at developing a device based on wireless sensor network to measure the temperature of concrete being cured in formwork. The result showed that the wireless sensor with probe type thermistor which is developed had the same temperature data compared to the existed wire type thermistor, and we confirmed the temperature history of concrete in real time for 28 days throughout the gateway by wireless network that collects the temperature data measured from specimens in laboratory. Also, the network device for transmission can be easily separated from the probe sensor part and reused consistently. If the wireless sensor network device developed uses in the field, the temperature management of concrete will be systematically conducted from at the early stage of the curing, and especially be effective for cold weather concrete construction. In addition, it will contribute to the establishment of advanced quality control system for concrete and productivity of supervisors on site will be increased in the future.

Characteristics of PM10, PM2.5 and CO2 Concentration in Public Transportations and Development of Control Technology (대중교통수단에서 PM10, PM2.5 및 CO2의 농도 현황과 저감기술 개발에 관한 연구)

  • Park, Duck Shin;Kwon, Soon Bark;Cho, Young Min;Jang, Seong Ki;Jeon, Jae Sik;Park, Eun Young
    • Particle and aerosol research
    • /
    • v.6 no.1
    • /
    • pp.9-20
    • /
    • 2010
  • This study examined the concentration level of the major air pollutants in public transportation. The study was conducted between February 2009 and March 2008 at Suwon-Yeosu line in Korea. $PM_{10}$ concentration level was $100{\mu}g/m^3$ on average. The $PM_{2.5}$ to PM10 ratio in transport is 0.37, which was lower than the results published by other researches. The result also demonstrated that outdoor $PM_{10}$ concentration was about 56~60% level compared to that of the cabin. $CO_2$ concentration level in the cabin was 1,359ppm, which does not exceed 2,000ppm, which is the guideline concentration level according to the Ministry of Environment. $CO_2$ concentration level in the cabin was $CO_2=23.4{\times}N+460.2$, and about 23.4ppm in $CO_2$ concentration level increased every time one passenger was added on. The experiment conducted on the train demonstrated that the average $PM_{10}$ concentration level was $100{\mu}g/m^3$ in case of the reference cabin while average $PM_{10}$ concentration level of the modified vehicle was $68{\mu}g/m^3$. Likewise, effect of the particle reduction device for the reduction of $PM_{10}$ concentration level was approximately 21%. Meanwhile there was almost no difference in the concentration level between reference and modified cabin in case of $PM_{2.5}$. Using zeolite as an adsorbent was made to reduce the $CO_2$ concentration level in the cabin. Number of passengers was factored in, to calculate the effect of the adsorption device, which demonstrated that about 36% of $CO_2$ concentration level was reduced in the modified cabin effect of the $CO_2$ reduction device. This research analyzed the current status concerning the quality of air in the public transportation and technologies were developed that reduces major air pollutants.

Design and implement of patch type wireless skin temperature measuring system (패치형 무선 피부 온도 측정 시스템의 설계 및 구현)

  • Woo, S.H.;Park, S.Y.;Din, Z. Mohy Ud;Won, C.H.;Lee, J.H.;Park, H.J.;Lee, J.W.;Hong, Y.G.;Suh, J.H.;Youm, Y.G.;Cho, J.H.
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.350-360
    • /
    • 2008
  • In every large hospital, nurses must perform simple repetitive tasks such as measuring body temperature. Such tedious work reduces nurses' motivation to provide quality medical care, which is an important element of the medical services provided by a hospital. If a device were available to measure body temperature, nurses could focus on the more important aspects of providing quality medical care to the patients. However, body temperature is generally measured from the throat, anus, tympanum or armpit, where it is difficult to affix a patch type device. In addition, general body temperature measuring points shows moving artifact error; therefore, it is not good point to continually measure the temperature. In this paper, a patch type skin temperature measuring system was developed. To appropriately measure the skin temperature, a thermal transducer was implemented with a thin (0.5 mm) temperature sensor. The system is small and thin ($H6.6{\sim}5.3{\times}L35{\times}W24\;mm$), and weighs only 5 g including a battery, case and circuit; therefore, it is small and light enough to function as a patch type device. Moreover, the system worked for 5 days. To investigate differences between the experimental and conventional thermometer, simple clinical experiments were performed with 17 volunteers, and the result showed some correlation between the implemented system and conventional thermometer (Correlation coefficient = 0.647, P<0.1).

Status of Employment-Related Qualifications Similar to a Medical Laboratory Technology Major (임상병리기술학 전공 유사 취업연계 자격 현황)

  • Sung, Hyun Ho;Kim, Dae Sik;Cho, Young Kuk;Yoon, Ki Nam
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.50 no.4
    • /
    • pp.525-534
    • /
    • 2018
  • This study evaluated the various qualifications that can be linked to employment similar to the medical laboratory technology major. The qualifications for employment outside the medical laboratory technology major are industrial health instructor, doping control officer, audiologist, sign language interpreter, health education specialist, claim adjuster, Korea life underwriter, administrative manager, hospital administrator, insurance review manager, and hospital coordinator. The qualifications for employment similar to the medical laboratory technology major include the clinical research coordinator, clinical research associate, anatomist, analytical chemistry analysts, hazardous materials industry engineers, biotechnologist, biosafety managers, biotechnology technicians, medical device quality officers, animal care nurse, industrial engineer hazardous material, bioprocess engineer, biosafety officer, certified technology consultant, director of medical device quality control, laboratory animal technician, animal nursing technician, and cruise medical manager. Therefore, it is necessary to conduct a social analysis survey of the various qualifications currently held by medical technologists. In addition, it will be necessary to investigate the current status of medical technologists working in other fields. In the future, medical technologists should expand the scope of their work through efforts to strengthen their individual work capacity, share cases, and strengthen their expertise.

A Study on the Water Quality Management of Modular Revetment Structure installed Low-Maintenance Constructed Wetland (플랜터형 호안구조물을 설치한 저관리형 습지의 수질 제어 기작에 관한 연구)

  • Ham, Eun Kyung;Choi, Yun Eui;Kim, Min;Chon, Jinhyung
    • Journal of Wetlands Research
    • /
    • v.17 no.2
    • /
    • pp.184-192
    • /
    • 2015
  • This study is a basic research for low maintenance constructed wetlands which can prevent water quality deterioration due to wetland soils. The purpose of this study is to analyze water quality control mechanisms of constructed wetland on the artificial ground which installed the modular revetment structure(MRS), a device that separates water and soil. This study was then conducted with two different wetland mesocosms (a treatment plot and a control). These mesocosms were monitored to analyze effects of water quality control of the MRS. A treatment plot was built, and separated into soil and water, by filling the MRS with the decomposed granite soil in the mesocosm made of rubber material. A control plot was built where the decomposed granite soils were exposed to water by leaving the soil on the bottom of the mesocosm made of rubber material. Water quality was then analyzed by using Kolmogorov-Smirnov Z examination which then showed that pH, BOD, SS, Chl-a, T-P, T-N had statistically valid difference between a container with the MRS and one without it. According to the analysis of the water quality, the temperature and the EC level came out similarly and both mesocosm showed same level on pH and DO. A treatment plot had higher levels of BOD, SS Chl-a, and T-P. A control plot's T-N value was little lower than that of the treatment plot. This study suggests method of constructed wetlands using the MRS prevents problems occurring in wetland soils: aridity of wetlands by soil erosion, eutrophication, and algal blooms due to nutrients released from wetland soil. These functions of constructed wetland with the MRS increase aesthetic, ecologic, social, and economic value of the wetland. Outcomes of this research will later enable more proficient way of stabilizing water quality and provide data for planning low maintenance constructed wetlands.

Laver(Kim) Thickness Measurement and Control System Design (해태(김)두께측정 및 조절 장치 설계)

  • Lee, Bae-Kyu;Choi, Young-Il;Kim, Jung-Hwa
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.11
    • /
    • pp.226-233
    • /
    • 2013
  • In this study, In Laver's automatic drying device, laver thickness measurement and control devices that are associated with. Disconnect the water and steam, after put a certain amount of the mixture(water and laver) in the mold. In process, Laver of the size and thickness (weight) to determine, constant light source to detect and image LED Lamp occur Vision Sensor (Camera) prepare, then the values of these state of the image is transmitted in real time embedded computers. Built-in measurement and control with the purpose of the application of each of the channels separately provided measurements are displayed on a monitor, And servo signals sent to each of the channels and it become so set function should be. In this paper, the laver drying device, prior to the laver thickness measurement and control devices that rely on the experience of existing workers directly laver manually adjust the thickness of the lever, but the lever by each channel relative to the actuator by installing was to improve the quality. In addition, The effect of productivity gains and labor savings are.

Quantitative Analysis of Effects for Quality Control on Medical Primary Class LCD Display Devices Based on AAPM TG18 Report (AAPM TG18에 의한 진단용 LCD 디스플레이 장치 정도관리 효과의 정량적 분석)

  • Jung Hai-Jo;Kim Hee-Joung
    • Progress in Medical Physics
    • /
    • v.17 no.2
    • /
    • pp.77-82
    • /
    • 2006
  • The image display is an Important component of PACS and of medical digital imaging chain. Displayed image qualify is affected by the physical characteristics of display device, appropriate clinical settings and calibrations, and ambient lighting conditions. The performance of display systems is continuously degraded over time due to luminance deterioration and changes of clinical setting parameters. A routine QC is recommended because the performance of display systems is continuously degraded over time. Ten flat panel monochrome LCD display devices were included in the evaluation of the QC effect. The effect of QC on primary class LCD medical display devices for selected QC tests was evaluated by comparing the performances, luminance response, luminance dependencies, display resolution and display chromaticity in this study, of before and after the calibration procedures. The effects of the QC are significant to luminance response and luminance spatial dependencies test and the other side, are slight to the display resolution and display chromaticity test. A routine QC of display device is essential for the consistency of medical image display and presentation. The study of the QC effects of display devices will play an important role in practical QC procedures of display devices.

  • PDF