• 제목/요약/키워드: Quality Measurement Method

검색결과 1,463건 처리시간 0.027초

종이 헬리콥터 실험을 통한 개발단계 성능변동의 이해와 개선 (Understanding and Reducing Performance Variation in New Product Development Using Paper Helicopter Experiment)

  • 신병철;김시웅;정순민;변재현;남용석
    • 품질경영학회지
    • /
    • 제43권4호
    • /
    • pp.589-606
    • /
    • 2015
  • Purpose: In developing new products, reducing performance variation is important for competitiveness factors such as quality, cost, and delivery. This paper aims at evaluating three performance variations; measurement, performance evaluation, and manufacturing variations, and then improving product and process design, focused on paper helicopter making case study. Methods: For measurement system analysis, gage R&R (repeatability and reproducibility), linearity, stability are evaluated. Since gage R&R are not satisfactory, the measurement system is improved by adopting voice memos application of iPhone and providing standard measurement procedure. To evaluate performance variation, product deterioration and environment factor (wind speed) is considered. Since the existing design is sensitive to these noise factors, a new product design is developed, which is proven to be robust to the noise factors. Finally, manufacturing variations are evaluated with five factors which can cause variation in flight time. To reduce the impact of three significant factors, three improvement methods are applied. Results: Three performance variations are evaluated and robust paper helicopter design is presented. Conclusion: To reduce measurement and process variations, improved measurement method and paper helicopter making procedure are proposed. A new product design is also presented which is robust to deterioration and environmental variation. This paper is expected to benefit students and practitioners who want to have hands-on knowledge on new product quality improvement.

MTF 측정을 통한 비정질 셀레늄 기반의 디지털 방사선 검출기의 영상 질 평가에 관한 연구 (Image Quality of Amorphous Selenium DR system using MTF measurement)

  • 석대우;박지군;최장용;남상희;강신원
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.384-387
    • /
    • 2003
  • In this paper, the evaluation of image quality was performed for digital radiography which is developing in using amorphous selenium as a photoconductor material for the purpose of offering basic research data and measurement technique about Medical Imaging Quality. So Modulation Transfer Function as a main factor of imaging quality evaluation was investigated by slit method. For measurement of MTF, Nuclear associates. 07-624 Slit camera image was obtained to study the variation of MTF corresponding to changing spatial frequency. And Presampling MTF was estimated by slit camera image with $10\;{\mu}m$ width at Digital Radiography. In this study, the obtained data demonstrates that the clinical value of a direct conversion type digital radiation detector using the amorphous selenium, which is being developed by domestic technology.

  • PDF

FHD급 DIC 플랫폼의 변위계측용 영상품질 분석 (Analysis of DIC Platform and Image Quality with FHD for Displacement Measurement)

  • 박종배;강민구
    • 인터넷정보학회논문지
    • /
    • 제19권1호
    • /
    • pp.105-111
    • /
    • 2018
  • 건축 구조물의 상대적인 변위 계측을 위하여 2메가 픽셀 Full HD(FHD) 해상도의 카메라와 디지털 영상상관(DIC, Digital Image Correlation) 플랫폼을 설계하고, 계측에 영향을 주는 영상 품질을 분석하였다. DIC 플랫폼은 Freescale사의 I.MX6를 기반으로 설계하였다. 영상 상관을 이용한 계측은 영상의 품질에 따라 계측 정밀도에 영향을 줄 수 있는데, 이러한 영상 품질 요인으로 영상의 밝기(brightness), 대조(contrast), 신호대 잡음비(SNR, Signal to Noise Ratio)를 분석하였다. 관심 영역(ROI, Region Of Interest)으로 설정한 부분에서 추출한 영상을 기준 영상으로 삼고, 일정 시간 경과 후 디지털 영상 상관(DIC)을 이용하여 기준 영상의 이동을 화소 및 부화소 단위로 추적 계산하여 변위를 측정하였다. 더불어 DIC 기반의 비접촉 원격 계측의 유효성을 파악하기 위하여 25m, 35m, 50m의 계측 거리에서, 영상 품질 요인 및 ROI 의 크기를 조정하여 측정을 하고 정밀도를 분석하였다.

도서관 모바일 서비스 품질 평가 모형 개발에 관한 연구 (A Study on Developing a Service Quality Evaluation Model for Library Mobile Service)

  • 한승희
    • 정보관리학회지
    • /
    • 제34권4호
    • /
    • pp.273-292
    • /
    • 2017
  • 이 논문은 서비스 품질 관점에서 도서관 모바일 서비스를 위한 평가 모형을 개발하는 것을 목적으로 한다. 이를 위해 본 연구에서는 기존에 연구된 도서관의 서비스 품질 평가 모형과 모바일 서비스 평가 연구에 대한 문헌 분석을 실시하였으며, 이를 토대로 도서관 모바일 서비스 품질 평가에 필요한 4개 품질 차원, 10개 품질 요인, 39개 품질 측정 항목으로 구성된 평가 모형을 개발하였다. 그리고 개발된 모형의 타당성을 검증하기 위해 델파이 기법을 적용하였으며, 최종적으로 4개 품질 차원, 9개 품질 요인, 37개 품질 측정 항목으로 구성된 모형을 도출하였다. 이 연구에서 제안하고 있는 평가 모형은 도서관의 모바일 서비스 품질 진단 도구로 사용될 수 있으며, 또한 도서관 모바일 서비스의 개선을 위한 가이드라인으로도 활용될 수 있다.

Digital Image Quality Assessment Based on Standard Normal Deviation

  • Park, Hyung-Ju;Har, Dong-Hwan
    • International Journal of Contents
    • /
    • 제11권2호
    • /
    • pp.20-30
    • /
    • 2015
  • We propose a new method that specifies objective image quality factors by evaluating an image quality measurement model using random images. In other words, No-Reference variables are used to evaluate the quality of an original image without using any reference for comparison. 1000 portrait images were collected from a web gallery with votes constituting over 30 recommendation values. The bottom-up data collecting process was used to calculate the following image quality factors: total range, average, standard deviation, normalized distribution, z-score, preference percentage. A final grade is awarded out of 100 points, and this method ranks and grades the final estimated image quality preference in terms of total image quality factors. The results of the proposed image quality evaluation model consist of the specific dynamic range, skin tone R, G, B, L, A, B, and RSC contrast. We can present the total for the expected preference points as the average of the objective image qualities. Our proposed image quality evaluation model can measure the preferences for an actual image using a statistical analysis. The results indicate that this is a practical image quality measurement model that can extract a subject's preferred image quality.

패키지 소프트웨어의 품질인증을 위한 측정척도변환 (Measurement Scale Conversion for the Certification of Quality of Package Software)

  • 유영관;이종무
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2002년도 춘계학술대회
    • /
    • pp.193-197
    • /
    • 2002
  • The certification of software products can provide a greater level of acceptance and feeling of security to customers of these products. This paper presents a certification method for the quality of package software. First of all, the evaluation criteria are derived from IS0/1EC 9126 and 12119 standards, and then the evaluation module are designed considering the measurement scale type. The results can be applied to construct the certification scheme of software product quality for the commercial purpose.

  • PDF

굳지 않은 콘크리트 단위수량 추정기법의 성능 검토에 관한 연구 (A Study on the Investigation of Performance for Evaluation Method of Unit Water Content of Fresh Concrete)

  • 김용로;최일호;정양희;김효락;이도범
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.367-370
    • /
    • 2005
  • In this study, air meter method and capacitance measurement method to apply economically at quality control of ready-mixed concrete among various unit water content measurement technique was selected. Then, it was evaluated estimating performance of unit water content according to the change of water-binder ratio and unit water content. Also, it was examined influence about error occurrence of unit water content by change of properties of used materials. Finally, based on this study, it was proposed fundamental data to utilize measurement technique of unit water content to quality control. of ready-mixed concrete in construction field.

  • PDF

NC 밀링머신의 Volumetric 오차보상을 통한 포물면 가공의 정밀도 향상 (Enhancement of a parabolic face working accuracy using volumetric error compensation of NC milling machine)

  • 이찬호;정을섭;이응석;김성청
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 춘계학술대회 논문집
    • /
    • pp.917-921
    • /
    • 2000
  • One of the major limitations of productivity and quality in machining is machining accuracy of the machine tools. The machining accuracy is affected by geometric, volumetric errors of the machine tools. This paper suggests the enhancement method of machining accuracy for precision machining of high quality metal reflection mirror or optics lens, etc. In this paper, we study 1) the compensation of linear pitch error with NC controller compensation function using laser interferometer measurement, 2) the method for enhancing the accuracy of NC milling machining by modeling and compensation of volumetric error, 3) the generation of the parabolic face profile. And the method is verified by the parabolic face machining experiment with a vertical three axes NC milling machine. After this study, we will inspect using On-machine measurement and study the repetitive machining by a compensated path

  • PDF

주성분 분석을 이용한 측정시스템의 경제적 평가 (Economic Evaluation of Measurement System by Principal Component Analysis)

  • 강충오;변재현
    • 대한산업공학회지
    • /
    • 제24권2호
    • /
    • pp.211-221
    • /
    • 1998
  • It is very important to have a satisfactory measurement system, since it is useless to try to improve the manufacturing process without an adequate measurement system. Therefore, evaluation of the measurement system is the first step for the quality improvement of the manufacturing process. To estimate the measurement error we must conduct a controlled gage repeatability and reproducibility(gage R&R) study. Many manufacturers use a gage or instrument to measure multiple dimensions for the overall quality of the manufactured parts. In this case, it is necessary to estimate the gage R&R for multiple dimensions. When a gage measures a large number of dimensions of a part, it is very time-consuming and costly to measure all the dimensions. In this paper we propose the use of the principal component analysis method to identify a few principal components out of the original multivariate measurement capability to explain most of the measurement system variation pattern.

  • PDF

An Analysis about Recognition of Indoor Air Quality of Workers at Dental Clinics in Jeollanamdo Area

  • Choi, Mi-Suk
    • 한국컴퓨터정보학회논문지
    • /
    • 제23권11호
    • /
    • pp.137-142
    • /
    • 2018
  • The purpose of this study is to contribute to the improvement of indoor air quality management in dental clinic by investigating the level of indoor air quality recognition among dental clinic workers. The questionnaire survey was conducted for about 4 weeks from May 20 to June 20, 2018 in dental clinics located in Jeollanamdo area and 143 were used as the analysis data. The method of indoor air quality management in dental clinic was preferred to "natural ventilation" method and the number of natural ventilation was 1 to 2 times per day and the results of survey on indoor environment satisfaction showed that satisfaction level was lowest in noise and smell items. The types of subjective symptoms experienced by workers working at dental clinics are "cough", "eye burn", and "headache" and a survey on the degree of the relationship between subjective symptoms and indoor air quality showed that 94.4% (135) of respondents answered "very relevant" and "slightly related". As a result of multiple regression analysis, the variables affecting the indoor air quality satisfaction of the dental clinic staff were analyzed as the items such as lighting, noise, main work, number of patients, comparing indoor and outdoor air quality and among them, "comparing indoor and outdoor air quality" was analyzed as having a great influence. To improve the indoor air quality satisfaction of dental clinic worker adequate ventilation, designate the person responsible for the indoor air quality management and periodic measurement efforts will be necessary.