• 제목/요약/키워드: Quality Measurement Method

검색결과 1,468건 처리시간 0.028초

A study on Measurement and Improvement of Indoor Air Quality in Dental Clinic

  • Choi, Mi-Suk;Ji, Dong-Ha
    • 한국컴퓨터정보학회논문지
    • /
    • 제23권11호
    • /
    • pp.143-149
    • /
    • 2018
  • The purpose of this study is to propose a management method to maintain the pleasant indoor air quality of the dental clinic by measuring and analyzing the indoor air quality of the dental clinic. The measurement was conducted in two rooms, a lobby where many residents stay in the reception room for waiting for medical treatment, and a VIP room where treatment activities are mainly performed. Measurement items are Temperature, Humidity, $CO_2$, CO, $NO_2$, $CH_2O$, VOC, $PM_{10}$ and measurement were taken on April 27, 2018. As a result of analyzing the temperature and humidity of the dental clinic, it was analyzed that the average indoor temperature was maintained at $25^{\circ}C$ and the humidity was kept at around 50%, maintaining proper indoor temperature and humidity environment. $CO_2$ was 855ppm in the VIP Room, which satisfied the maintenance standard. In the case of the lobby, it was analyzed to be 1,160ppm, which exceeded the maintenance standard and it is judged that the carbon dioxide generated by the respiration of the people staying in the lobby is the main reason. The mean concentration of formaldehyde in the VIP room was analyzed as $436{\mu}g/m^3$, exceeding the maintenance standard, and $2,100{\mu}g/m^3$ for the VOC exceeded the recommended standard. It was analyzed that the concentration was relatively higher due to the use of disinfectant and other drugs. The mean concentration of PM-10 in the lobby was analyzed as $65{\mu}g/m^3$ and it was analyzed that it satisfied the maintenance standard. To maintain a pleasant indoor air quality in a dental clinic it is necessary to minimize the effects of formaldehyde, VOC, $CO_2$ in the VIP rooms and lobby. For this purpose, the entire ventilation system and air purification system of the dental clinic should be installed. In case of the VIP room, local exhaust ventilation should be installed and workers should wear personal protective equipment.

인쇄 패턴의 기하학적 특성 측정 및 인쇄성 평가 (Measurement of Geometric Properties of Printed Patterns and Evaluation of their Printability)

  • 전선웅;김철;박종찬;김동수;김충환
    • 한국정밀공학회지
    • /
    • 제31권11호
    • /
    • pp.981-986
    • /
    • 2014
  • Printed electronics devices are made of several sets of printed patterns. The quality or printability of the printed patterns determines the electrical performance of such devices. Moreover, control of the printability determines the reliability of such devices. Despite its importance, few studies have been reported for the measurement of the printed patterns to evaluate their printability. In this study, a measurement method is proposed for printed patterns, including the definition of the properties to be measured, and the related software is described. The proposed method measures the width, pinholes, and edge waviness and evaluates the printability of the patterns quantitatively. The proposed measurement method could be an efficient tool to evaluate and enhance the printability of printed patterns in printed electronics.

Assessment of Gradient-based Digital Speckle Correlation Measurement Errors

  • Jian, Zhao;Dong, Zhao;Zhe, Zhang
    • Journal of the Optical Society of Korea
    • /
    • 제16권4호
    • /
    • pp.372-380
    • /
    • 2012
  • The optical method Digital Speckle Correlation Measurement (DSCM) has been extensively applied due its capability to measure the entire displacement field over a body surface. A formula of displacement measurement errors by the gradient-based DSCM method was derived. The errors were found to explicitly relate to the image grayscale errors consisting of sub-pixel interpolation algorithm errors, image noise, and subset deformation mismatch at each point of the subset. A power-law dependence of the standard deviation of displacement measurement errors on the subset size was established when the subset deformation was rigid body translation and random image noise was dominant and it was confirmed by both the numerical and experimental results. In a gradient-based algorithm the basic assumption is rigid body translation of the interrogated subsets, however, this is in contradiction to the real circumstances where strains exist. Numerical and experimental results also indicated that, subset shape function mismatch was dominant when the order of the assumed subset shape function was lower than that of the actual subset deformation field and the power-law dependence clearly broke down. The power-law relationship further leads to a simple criterion for choosing a suitable subset size, image quality, sub-pixel algorithm, and subset shape function for DSCM.

The E-Servqual Effect on the Stickiness Intention of Marketplace During COVID-19 Pandemic: An Empirical Study in Indonesia

  • KUSUMAWATI, Andriani;AUGUSTINAH, Fedianty;ALHABSYI, Taher;SUHARYONO, Suharyono
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제8권8호
    • /
    • pp.573-581
    • /
    • 2021
  • This paper examines the effect of e-service quality on the users of the Facebook marketplace. Users can always have stickiness intention. Stickiness intention is regarded as repetitive visits to and use of a certain website because of a commitment to continue using that website. Hence, we examine and explain the influence of e-service quality variables on stickiness intention. The variables used for e-service quality include efficiency, fulfillment, system availability, and privacy. The researchers related stickiness intention variable to online media users who always use the Facebook marketplace longer than other marketplaces, and users who visit the Facebook marketplace more often than other marketplaces. The method of data analysis was using inferential statistics GeSCA method. The GeSCA method is a Structural Equation Modeling (SEM) technique that can directly analyze latent variables, indicators, and measurement errors. The results of the GeSCA method before the COVID-19 pandemic states that an increase in e-service quality by 77.5% will increase stickiness intention by 61.2%. The results of the GeSCA method after the COVID-19 pandemic states that an increase in e-service quality by 85.2% would increase stickiness intention by 81.1%. This indicates that Facebook marketplace users had more stickiness intention for the Facebook marketplace.

다구찌의 피드백 제어 시스템에 관한 연구 (A Study on Taguchi's Feed-back Control System)

  • 김지훈;정해성;김재주
    • 품질경영학회지
    • /
    • 제26권3호
    • /
    • pp.60-70
    • /
    • 1998
  • When driving the expected loss generated by the quality deviation, Taguchi(1991b) assumed that an objective characteristic has the uniform distribution in its control limit. But it is reasonable to assume that an objective characteristic has the normal distribution than the uniform distribution. Since the triangular distribution is similar to the normal distribution and easy to handle as well, in this article, we first find the optimum measurement interval and the optimum control limit under the triangular distribution. Under the normal assumption, the modified method is compared to Taguchi's. Secondly we find the numerical value solution of the optimum measurement interval and the optimum control limit under the normal distribution.

  • PDF

Improved Angle-of-View Measurement Method for Display Devices

  • Lee, Eun-Jung;Chong, Jong-Ho;Yang, Sun-A;Lee, Hun-Jung;Shin, Mi-Ok;Kim, Su-Young;Choi, Dong-Wook;Lee, Seung-Bae;Lee, Han-Yong;Berkeley, Brian H.
    • Journal of Information Display
    • /
    • 제11권1호
    • /
    • pp.17-20
    • /
    • 2010
  • With the increasing demand for a better FPD image quality, better evaluation metrics and advanced display quality measurement methods are required to meet these needs. There are many measurement methods for evaluating the viewing angle of various display devices, but these methods, which include luminance drop, color shift, and contrast ratio decrease, are imperfect considering that human perception does not completely correlate to them. In this paper, a new method of measuring the perceptual angle of FPDs is proposed, considering human visual perception, which uses the color space of the color appearance model.

Improved Method for Angle-of-View Measurement of Display Devices

  • Lee, Eun-Jung;Chong, Jong-Ho;Yang, Sun-A;Lee, Hun-Jung;Shin, Mi-Ok;Kim, Su-Young;Choi, Dong-Wook;Lee, Seung-Bae;Lee, Han-Yong;Berkeley, Brian H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.979-982
    • /
    • 2009
  • With increasing demand for better FPD image quality, better evaluation metrics and advanced display quality measurement methods are required to meet these needs. There are many measurement methods to evaluate viewing angle of the various different display devices. However, these methods, which include luminance drop, color shift, and contrast ratio decrease, are imperfect considering that human perception does not completely correlate to these methods. In this paper, we propose a new method for measuring perceptual angle of FPDs considering human visual perception, which uses color space of the color appearance model.

  • PDF

Bacterial community comparison revealed by metagenomic analysis and physicochemical properties of eastern little tuna (Euthynnus affinis) with storage temperature differences

  • Asadatun Abdullah;Rahadian Pratama;Tati Nurhayati;Windy Sibuea;Sabila Diana Ahmad Sauqi
    • Fisheries and Aquatic Sciences
    • /
    • 제26권10호
    • /
    • pp.593-604
    • /
    • 2023
  • Post-harvest handling and hygienic level of aquatic products significantly affect the quality and level of safety. Cold chain control is one of the determining factors for the quality of fish and the bacterial community that grows on the fish. Identification of spoilage bacteria and pathogens in aquatic products must be made because it will determine the physical and chemical quality. A molecular identification method with high sensitivity is the solution. This study aims to identify the quality of fish and bacterial communities that grow. The research procedures included sample collection, pH measurement, drip loss measurement, transportation and cold storage treatment, DNA extraction, DNA sequencing, sequence analysis, and bioinformatics analysis. The conclusion obtained from this study is that the simulation of the cold chain system applied to eastern little tuna does not significantly affect changes in the water activity value, pH, and drip loss. The insignificant change indicates that the eastern little tuna samples are still in good quality. The bioinformatics analysis showed the highest diversity and abundance of the bacterial community came from the Gammaproteobacterial class.

자동화장비 계측효율 관리적 측정방법 제안 (A Suggestion for Counting Efficiency Management of the Automation Instrument)

  • 박준모;김한철;최승원
    • 핵의학기술
    • /
    • 제22권2호
    • /
    • pp.105-111
    • /
    • 2018
  • Purpose Quality control of instrument takes up a large part in the Radioimmunoassays. The gamma-ray instrument, which is one of the important instruments in the laboratory, observes the condition and performance of instrument and performs quality control of the instrument by measuring the Normalization, Calibration, Background and etc. However, there are some automation instruments which can't measure the counting efficiency of gamma-ray meters, resulting in insufficient management in terms of performance evaluation of gamma-ray meters. Therefore, the purpose of this paper is to manage the quality control continuously and regularly by suggesting how to measure the counting efficiency of gamma-ray instruments. Materials and Methods In case of a comparative measurement method to a gamma-ray instrument dedicated to nuclear medical examination, the CPM and counting efficiency can be obtained after the measurement of normalization by inserting the I-125 $200{\mu}L$(CPM 50,000~500,000) into the test tube. With this CPM and counting efficiency values, it's possible to calculate the measurement of the DPM value and count the CPM from the automation instrument from the same source, and enter the DPM to calculate the counting efficiency using a comparative measurement method. Another method is to calculate the counting efficiency by estimating the half life using the radiation source information of the tracer in B test reagents of company A. Results According to the calculation formula using the DPM obtained by counting the normalization of gamma-ray meters, the detection efficiency was 75.16% for Detector 1, 76.88% for Detector 2, 77.13% for Detector 3, 75.36% for Detector 4 and 73.2% for Detector 5 respectively. Using another calculation formula estimated from the shelf life, the data of the detection efficiency from Detector 1 to Detector 5 were 74.9%, 75.1%, 76.5%, 74.9% and 73.2% respectively. Conclusion Although the accuracy of counting efficiencies of both methods are insufficient, this is considered to be useful for ongoing management of quality control if counting efficiency is managed after setting the acceptable ranges. For example, if the measurement efficiency is set to 70% or higher, the allowed %difference between measurements is within 3% and the %difference with the detector wall is set within 5%.