• Title/Summary/Keyword: Quality Measurement Method

Search Result 1,468, Processing Time 0.031 seconds

A Study on Development of Multi-item Scale for Assessing Airline Cabin Service Quality (항공객실서비스 품질 측정 모형 개발에 관한 연구)

  • Kim, Yoonjin;Kim, Youn Sung
    • Journal of Korean Society for Quality Management
    • /
    • v.45 no.3
    • /
    • pp.483-501
    • /
    • 2017
  • Purpose: Recognizing the limitations of the previous researches that measured the quality of airline service quality only with partial evaluation items of cabin service quality. the purpose of this study is to standardize and develop assessment of the airline cabin service quality with considering the characteristics of cabin service and customer needs. Methods: The proposed method of this paper was the empirical items of airline cabin service quality was derived through reviewing and comparing the previous researches, industrial indicators like Skytrax and KS-SQI and NCS. Results: The result of this research proposed CSQ (Cabin SERVQUAL) which could consist of seven dimensions, separated by five direct customer satisfaction factors and two indirect factors required for providing customer service. Conclusion: The developed CSQ can be used for airline service quality measurement which will achieve establishing a strategy to improve customer satisfaction and satisfaction of Airline's employee.

Quality Evaluation of Engineering Computer Programs Using Software Quality Metrics (Software Quality Metrics를 이용한 공학용 전산 프로그램의 품질특성 측정)

  • 조문성;남지희
    • Journal of Korean Society for Quality Management
    • /
    • v.25 no.4
    • /
    • pp.115-130
    • /
    • 1997
  • SQM (Software Quality Metrics) is a methodology whose primary objective is the measurement of compliances to requirements using a set of software life cycle properties called quality factors, which is based on the hierachical relationshiips between factors, criteria and elements. For this study, two factors (Correctness, Maintainability) and five criteria were selected. In addition, several tens of quality elements were developed to su, pp.rt them. Qualities of three computer programs which are being used for engineering purpose were measured. As a result, it is concluded that SQM is a valuable method for continuously monitoring the pulse of software quality development and that it can be used as a tool for software quality assurance.

  • PDF

On the Application Plan Study of International Standard Tendency in Software Quality Testing (소프트웨어 품질 평가 국제 표준 적용 방안에 대한 연구)

  • Jung Hye-Jung
    • Journal of Internet Computing and Services
    • /
    • v.7 no.4
    • /
    • pp.1-10
    • /
    • 2006
  • We are studying international standard about the software quality evaluation. The software quality has been more important on users and developers. In this paper, first, we study international tendency of the inside and outside of the country in software quality evaluation for evaluating the software quality objectively and quantitatively, Second, we notify a new direction for software quality standard of inside and outside of country. Third, we study on the testing method of software reliability for making use of the software reliability growth model. Fourth, we spread method about standard of the software quality evaluation, fifth, we research into the international standard ISO/IEC 9126 and ISO/IEC 25000 series for evaluation of software quality testing, and we propose to the application plan of software quality testing.

  • PDF

Development of The Screw Lead Measurement System (나사 리드 측정시스템 개발)

  • Choi, Jong-Guen;Choi, Hyeon-Cheol;Kim, Hyung-Sun
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.5
    • /
    • pp.7-13
    • /
    • 2007
  • This study proposes a new screw measurement system that is capable of measuring the pitch or lead of a screw, which is one of the most important parameters representing the screw quality. There are various conventional methods for screw measurement including some mechanical and optical ones, but they can not be applied to measure the lead except the profiles or sizes. The newly suggested method is able to measure the pitch or lead directly. This is executed by scanning the thread with a digital probe while the target screw rotates. The devised measurement system is a integrated computer system which is composed of a stepping motor, a digital linear gauge and a chuck device for holding the measured screw. In order to operate the system effectively and conveniently, a computer program having graphical user interface facility is developed. Some experiments were done to prove the effectiveness of the system.

A Study on the Service Quality Assessment Utilizing 6 Sigma - Focused on Domestic Banks - (6 시그마를 활용한 서비스품질 평가에 관한 연구 - 국내 은행을 중심으로 -)

  • Kim, Jong-Hoon;Song, Gwang-Suk;Yoo, Han-Joo
    • Journal of Korean Society for Quality Management
    • /
    • v.39 no.4
    • /
    • pp.527-542
    • /
    • 2011
  • The importance of service industry in national economy is getting increasing due to current trend of aging society and increasingly desire for better quality of life. However, the level of labor productivity in domestic service industry is lower than Japan and Germany that are typically strong in manufacturing industry. Difficulty of process control and measurement in accordance with variability and intangibility which are features of service industry, is considered as the cause of this poor labor productivity in Korea. This study aims to present managerial implications by calculating sigma levels on branch bank service quality and suggesting the quality dimensions of banks can be checked through a gap comparison between the sigma level on service quality in the whole banks and service quality in each bank. Quality level presented by the KS-SQI is applied to the measurement method that Yoo Han Joo and Song Kwang Seok suggested in 2006. Spss18.0 is used as an analysis tool. As a result of factorial analysis, 7 dimensions of service quality in KS-SQI can be divided into new 3 dimensions of service quality. This study also suggests that width and number of questions in previous questionnaire shall be extended. The whole of the bank service quality level is evaluated 3 sigma. The research help banks to figure out their service quality level through gap comparison objectively.

Analysis of Tracking Accuracy with Consideration of Fighter Radar Measurement Characteristics (전투기 레이다 측정 특성을 고려한 추적정확도 분석)

  • Seo, Jeongjik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.8
    • /
    • pp.640-647
    • /
    • 2018
  • This study analyzes the tracking accuracy(tracking errors) of fighter radar. Measurement error, detection failure, and radar cross section(RCS) fluctuation in radar measurements degrade the measurement quality and hence affect the tracking accuracy. Therefore, these radar measurement characteristics need to be considered when analyzing the tracking accuracy. In this paper, a method for analyzing the tracking accuracy is proposed; this method considers the detection error, detection probability, and RCS fluctuation. Results from experiments conducted with the proposed method show that the detection probability and RCS fluctuation affect tracking accuracy.

Abdominal Wall Motion-Based Respiration Rate Measurement using An Ultrasonic Proximity Sensor (복부 움직임에 따른 초음파 근접센서를 이용한 호흡측정에 관한 연구)

  • Min, Se-Dong;Kim, Jin-Kwon;Shin, Hang-Sik;Yun, Young-Hyun;Lee, Chung-Keun;Lee, Jeong-Whan;Lee, Myoung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.2071-2078
    • /
    • 2009
  • In this paper, we proposed a non-contact respiration measurement system with ultrasonic proximity sensor. Ultrasonic proximity sensor approach of respiration measurement which respiration signatures and rates can be derived in real-time for long-term monitoring is presented. 240 kHz ultrasonic sensor has been applied for the proposed measurement system. The time of flight of sound wave between the transmitted signal and received signal have been used for a respiration measurement from abdominal area. Respiration rates measured with the ultrasonic proximity sensor were compared with those measured with standard techniques on 5 human subjects. Accurate measurement of respiration rate is shown from the 50 cm measurement distance. The data from the method comparison study is used to confirm the performance of the proposed measurement system. The current version of respiratory rate detection system using ultrasonic can successfully measure respiration rate. The proposed measurement method could be used for monitoring unconscious persons from a relatively close range, avoiding the need to apply electrodes or other sensors in the correct position and to wire the subject to the monitor. Monitoring respiration using ultrasonic sensor offers a promising possibility of non-contact measurement of respiration rates. Especially, this technology offers a potentially inexpensive implementation that could extend applications to consumer home-healthcare and mobile-healthcare products. Further advances in the sensor design, system design and signal processing can increase the range of the measurement and quality of the rate-finding for broadening the potential application areas of this technology.

A Study on Perceived Contrast Measure and Image Quality Improvement Method Based on Human Vision Models (시각 모델을 고려한 인지 대비 측정 및 영상품질 향상 방법에 관한 연구)

  • Choi, Jong Soo;Cho, Heejin
    • Journal of Korean Society for Quality Management
    • /
    • v.44 no.3
    • /
    • pp.527-540
    • /
    • 2016
  • Purpose: The purpose of this study was to propose contrast metric which is based on the human visual perception and thus it can be used to improve the quality of digital images in many applications. Methods: Previous literatures are surveyed, and then the proposed method is modeled based on Human Visual System(HVS) such as multiscale property of the contrast sensitivity function (CSF), contrast constancy property (suprathreshold), color channel property. Furthermore, experiments using digital images are shown to prove the effectiveness of the method. Results: The results of this study are as follows; regarding the proposed contrast measure of complex images, it was found by experiments that HVS follows relatively well compared to the previous contrast measurement. Conclusion: This study shows the effectiveness on how to measure the contrast of complex images which follows human perception better than other methods.

An Image Quality Evaluation Model for Optical Strip Signal-to-Noise Ratio in the Target Area of High Temperature Forgings

  • Ma, Hongtao;Zhao, Yuyang;Feng, Yiran;Lee, Eung-Joo;Tao, Xueheng
    • Journal of Multimedia Information System
    • /
    • v.8 no.2
    • /
    • pp.93-100
    • /
    • 2021
  • Under the time-varying temperature, the high-temperature radiation of forgings and the change of reflection characteristics of oxide skin on the surface of forgings lead to the difficulty of obtaining images to truly reflect the geometric characteristics of forgings. It is urgent to study the clear and reliable acquisition method of hot forging feature image under time-varying temperature to meet the requirements of visual measurement of hot geometric parameters of forgings. Based on this, this chapter first puts forward the quality evaluation method of forging feature image, which provides guarantee for the accurate evaluation of feature image quality. Furthermore, the factors that affect the image quality, such as the radiation characteristics of forgings and the photographic characteristics of cameras, are analyzed, and the imaging spectrum which can effectively suppress the radiation intensity of forgings is determined. Finally, aiming at the problem that the quality of image acquisition is difficult to guarantee due to the drastic change of radiation intensity of forgings under time-varying temperature, an image acquisition method based on minimum signal-to-noise ratio (SNR) based laser light intensity adaptation is proposed, which significantly improves the definition of feature light strips in forging images at high temperature, and finally realizes the clear acquisition of feature images of large-scale hot forging under time-varying temperature.

Study on Highly Accuracy Quality Evaluation of Spot Weld by use of Image Processing Technique

    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.5 no.4
    • /
    • pp.38-46
    • /
    • 1996
  • This paper discusses the feasibility of Ultrasonic Nondestructive Evaluation (UNDE) technique for sport weld quality. Ultrasonic c-scan image assisted by image processing technique was used for Nondestructive Evaluation(NDE) of spot weld quality. Ultrasonic testing results obtained were confirmed and compared by Optical Microscope and SAM(Scanning Acoustic Mircroscope) observation of the spot-weld cross section, The results show that the nugget dinameter can be successfully measured with the accuracy of 0.5mm. It was ascertained that ultrasonic c-scan technique is very effective method for the sake of the approach to the quantitative measurement of nugget diameter and the discrimination of the corona bond from nugget. Additional support for the above conclusions is provided by the results for galvanized steel. The ultrasonic results for galvanized welds generally correspond to the results for uncoated steel. Finally, it was found that the above-mentioned technique can be sufficiently applied to NDE method for securing the Quality Assurance(QA) of spot welded products in production line.

  • PDF