• Title/Summary/Keyword: Quality Diagnostic

Search Result 857, Processing Time 0.022 seconds

Evaluation of Magnetization Transfer Ratio Imaging by Phase Sensitive Method in Knee Joint (슬관절 부위에서 자화전이 위상감도법에 의한 자화전이율 영상 평가)

  • Yoon, Moon-Hyun;Seung, Mi-Sook;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.269-275
    • /
    • 2008
  • Although MR imaging is generally applicable to depict knee joint deterioration it, is sometimes occurred to mis-read and mis-diagnose the common knee joint diseases. In this study, we employed magnetization transfer ratio (MTR) method to improve the diagnosis of the various knee joint diseases. Spin-echo (SE) T2-weighted images (TR/TE 3,400-3,500/90-100 ms) were obtained in seven cases of knee joint deterioration, FSE T2-weighted images (TR/TE 4,500-5,000/100-108 ms) were obtained in seven cases of knee joint deterioration, gradient-echo (GRE) T2-weighted images (TR/TE 9/4.56/$50^{\circ}$ flip angle, NEX 1) were obtained in 3 cases of knee joint deterioration, In six cases of knee joint deterioration, fat suppression was performed using a T2-weighted short T1/tau inverse recovery (STIR) sequence (TR/TE =2,894-3,215 ms/70 ms, NEX 3, ETL 9). Calculation of MTR for individual pixels was performed on registration of unsaturated and saturated images. After processing to make MTR images, the images were displayed in gray color. For improving diagnosis, three-dimensional isotropic volume images, the MR tristimulus color mapping and the MTR map was employed. MTR images showed diagnostic images quality to assess the patients' pathologies. The intensity difference between MTR images and conventional MRI was seen on the color bar. The profile graph on MTR imaging effect showed a quantitative measure of the relative decrease in signal intensity due to the MT pulse. To diagnose the pathologies of the knee joint, the profile graph data was shown on the image as a small cross. The present study indicated that MTR images in the knee joint were feasible. Investigation of physical change on MTR imaging enables to provide us more insight in the physical and technical basis of MTR imaging. MTR images could be useful for rapid assessment of diseases that we examine unambiguous contrast in MT images of knee disorder patients.

  • PDF

Evaluation of Dosimetric Characteristics of Reproducibility, Linearity and Dose Dependence of Optically Stimulated Luminescence Dosimeters in Co-60 Gamma-rays (Co-60 감마선을 이용한 광자극발광선량계의 재현성, 선형성, 선량의존성에 대한 특성평가)

  • Han, Su Chul;Choi, Sang Hyoun;Park, Seungwoo;Kim, Chul Hang;Jung, Haijo;Kim, Mi-Sook;Yoo, Hyung Jun;Kim, Chan Hyeong;Ji, Young Hoon;Yi, Chul Young;Kim, Kum Bae
    • Progress in Medical Physics
    • /
    • v.25 no.1
    • /
    • pp.31-36
    • /
    • 2014
  • We aimed to evaluate the dosimetric characteristics of reproducibility, linearity and dose dependence of optical stimulated luminance dosimeter (OSLD) in the Co-60 Gamma-rays and to analyze with a precedent study in field of the diagnostic radiography and radiotherapy. The reproducibility was 0.76% of the coefficient of variation, the homogeneity was within 1.5% of the coefficient of variation and OSLD had supra-linear response more than 3 Gy. So the correlation between dose and count was fitted by quadratic function. The count depletion by repeated reading was 0.04% per reading regardless of the irradiated dose. And the half time of decay curve according to the irradiated dose was 0.68 min. with 1 Gy, 1.04 min. with 5 Gy, and 1.10 min. with 10 Gy, respectively. In case of annealing for 30 min, the removal rate was 88% with 1 Gy, 90% with 5 Gy, and 92% with 10 Gy, respectively and 99% in case of annealing time for 4 hour. It is feasible to use OSLDs for dose evaluation in Co-60 Gamma-rays when considering the uncertainty on the procedure according to the irradiated dose.

The Effectiveness Evaluation of Reconstruction Method Using DFOV Position Changes for Reduction of Artifact Around Hotspot in PET/CT Images (PET/CT 검사에서 열소 주변 인공물 감소를 위한 DFOV 위치 변화 재구성 방법의 유용성 평가)

  • Han, Dong Chan;Hong, Gun Chul;Choi, Choon ki;Lee, Hyeok;Choi, Seong Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.90-94
    • /
    • 2013
  • Purpose: In the PET/CT images, various artifacts cause degradation of the quantitative assessment. Most hotspot generated by radiopharmaceutical injection errors cause an artifact and degrade the quality of the images as well as the accuracy of the quantitative evaluation. The purpose of this study is to assess effectiveness of the elimination of the hotspot at the injection sites using shifting the center of DFOV (Display Field of View, DFOV) method and evaluate the quantitative evaluation of result. Materials and Methods: GE Discovery STE 16 (GE Healthcare, Milwaukee, USA) and 1994 NEMA phantom were used for imaging acquisition. Phantom was filled with 0.005 MBq/mL of $^{18}F-FDG$. A hotspot was artificially placed on the outside of the phantom. The ratio of hotspot area activity to background area activity was regulated as 200:1. After image acquisition with routine protocol, all of the images were reconstructed using the shifting the center of DFOV method that wasn't overlapped with hotspot. Those images obtained before and after applying the shifting reconstruction method were compared. ROIs (Region Of Interests) were set in the hotspot areas, meanSUVs and standard deviations were calculated. Percentage differences were calculated with those meanSUVs and standard deviations. The evaluation on the effects of the shifting reconstruction method was done by comparison of the meanSUVs and the standard deviations, which were calculated for background areas unaffected by hotspot. Results: In the areas of unaffected by hotspot, meanSUVs before and after applying the shifting of center of DFOV method were $0.67{\pm}0.06g/mL$ and $0.65{\pm}0.06g/mL$, respectively. In the artifact areas affected by hotspot, meanSUVs before and after applying the shifting of center of DFOV method were $0.32{\pm}0.08g/mL$ and $0.56{\pm}0.12g/mL$, respectively. The percentage differences of the area adjacent to the hotspot and the area distant from the hotspot were 65.3% and 97.4%, respectively. Conclusion: In the PET/CT images, meanSUV was improved by 32.1% when the effect of artifact was removed with application of the shifting the center of DFOV methode. In other areas unaffected by artifacts, meanSUVs were not significantly different after applying DFOV center shift method. As shown in the result, adverse effects of hotspot made by swelling in the injection site can be reduced by applying DFOV center shift method. Therefore, DFOV center shift method can be applied for the more precise quantitative evaluation, and contribute to the increase of the diagnostic value of the images.

  • PDF

Improved Acroparesthesia During Enzyme Replacement Therapy in a Patient Lately Diagnosed with Fabry Disease (진단이 지연된 Fabry 병 환자에서 효소대체요법을 통한 사지 말단 동통의 호전을 보인 1례)

  • Yang, Aram;Kim, Jinsup;Cho, Sung Yoon;Jin, Dong-Kyu
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.17 no.3
    • /
    • pp.92-95
    • /
    • 2017
  • Fabry disease (FD) is an X-linked lysosomal storage disorder caused by an ${\alpha}$-galactosidase A (GLA, MIM 300644) enzyme deficiency due to pathogenic variants in the ${\alpha}$-galactosidase A gene (GLA). The disease leads to accumulation of globotriaosylceramide (Gb3) and related glycophospholipids affecting nearly all major organ systems, with the primary sites damaged by Gb3 including renal glomeruli, myocardium, neurons of the dorsal ganglion and autonomic nervous system, and vascular endothelial and smooth muscle. Progressive deposition in these organ systems present with various clinical manifestations including acroparesthesia, renal failure and heart failure. Here, we report a Chinese male diagnosed with Fabry disease in his late $4^{th}$ decades showing improvement of acroparesthesia during enzyme replacement therapy (ERT). A 48-year-old Chinese man who presented with chronic recurrent severe burning pain in his fingers and toes since the age of 10, with worse involvement of the former visited to our clinic for further evaluation. His medical history included a transient ischemic attack aged 40 and diagnosed with stage 4-5 chronic kidney disease aged 47. In the family history, the patient's brother was found to be have Fabry disease 1 month before his visit. Except for his brother, all other members of the family are healthy. Based on his medical history and family history, he was strongly suspicious for Fabry disease. He was found to have a galactose-alpha-1,3-galactose level 4.96 (Reference range, 42.5-67.9) suggestive of Fabry disease. The followed sequencing of GLA coding region in our patient revealed hemizyosity for the mutation c.988C>T (Q330X) in Exon 7. Since ERT start, he showed significant improvement in his symptoms of burning sensation of fingers and toes. On the contrary, due to deteriorating kidney function even with ERT, he is considered for kidney transplantation. Despite of diagnostic delay until late 4th decades, ERT showed a potential improvement of acroparesthesia in our patient. However, late start of ERT can lead to poor outcome in multiorgan function. Therefore, early diagnosis with high index of suspicion followed by continuous ERT with regular monitoring have an impact on quality of life in Fabry disease.

  • PDF

The Evaluation of Radioimmunoassay kits for Insulin (Insulin 측정용 방사면역측정법 시약의 평가)

  • Shin, Yong Hwan;Kim, Yun Hyun;Lee, Il Kyu;Kim, Ji Young;Seok, Jae Dong;Shin, Suk Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.149-155
    • /
    • 2012
  • Purpose : Serum insulin levels are useful indicator which of reflecting the function of insulin secretion in pancreatic ${\beta}$ cell and diagnosis of diabetes, differentiating the cause of impaired glucose tolerance. Insulin measurement kits have shown some differences in many ways such as test methods as well as quality control. The purpose of this study was to evaluate the diagnostic performance of seven manufacturing companies commercial kits. Materials and Methods : The values of insulin measured by three manufacturing companies (Biosource, Siemens, TFB) with 59 samples in August 2009 were compared with those measured by four manufacturing companies (Immunotech, Izotope, BNIBT, Cisbio) with 68 samples in December 2011. We evaluated precision, recovery rate, dilution test and correlation of serum insulin measurement using seven manufacturing company kits. Statistical program SPSS 12.0 was used for the verification of results. Results : The coefficients variation of the precision on all seven different kits were showed within 5.0%. Recovery rate of Biosource, Siemens, TFB kits on three different levels showed 94.2~103.7%, 99.0~104.6%, 99.7~107.6% respectively. Immunotech, Izotope, BNIBT, Cisbio were 93.5~99.1%, 91.4~99.1%, 99.2~131.0%, 84.8~102.3% respectively. There was strong correlation between the measurement of insulin by Biosource kit and that by two commercial kits, Siemens (R2=0.96), TFB (R2=0.99). There was good correlation between the measurement of insulin by TFB kit and that by three commercial kits, Immunotech (R2=0.97), Izotope (R2=0.96), Cisbio (R2=0.97). In the dilution test performed with more than 200 ${\mu}IU/ml$ high concentration samples, samples with diabetes correctly was measured in all seven manufacturing kits. However, as measured with insulinoma samples TFB, Siemens, Izotope, Cisbio kits were correctly measured, but Biosource and Immunotech kits were measured 47.4 ${\mu}IU/ml$, 72.3 ${\mu}IU/ml$, respectively. Conclusion : Serum Insulin radioimmunoassay kits were showed excellent precision, correlation and good recovery rate. However, some kits were not measured correctly in the high concentration insulin values. when selecting a kit should be considered many factors that cost effectiveness, compatible for automation equipment, high performance kit, the environment for each laboratory such as reaction time and reporting time.

  • PDF

Usefulness of applying Macro for Brain SPECT Processing (Brain SPECT Processing에 있어서 Macro Program 사용의 유용성)

  • Kim, Gye-Hwan;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyeon-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.35-39
    • /
    • 2009
  • Purpose: Diagnostic and functional imaging softwares in Nuclear Medicine have been developed significantly. But, there are some limitations which like take a lot of time. In this article, we introduced that the basic concept of macro to help understanding macro and its application to Brain SPECT processing. We adopted macro software to SPM processing and PACS verify processing of Brain SPECT processing. Materials and Methods: In Brain SPECT, we choose SPM processing and two PACS works which have large portion of a work. SPM is the software package to analyze neuroimaging data. And purpose of SPM is quantitative analysis between groups. Results are made by complicated process such as realignment, normalization, smoothing and mapping. We made this process to be more simple by using macro program. After sending image to PACS, we directly input coordinates of mouse using simple macro program for processes of color mapping, adjustment of gray scale, copy, cut and match. So we compared time for making result by hand with making result by macro program. Finally, we got results by applying times to number of studies in 2007. Results: In 2007, the number of SPM studies were 115 and the number of PACS studies were 834 according to Diamox study. It was taken 10 to 15 minutes for SPM work by hand according to expertness and 5 minutes and a half was uniformly needed using Macro. After applying needed time to the number of studies, we calculated an average time per a year. When using SPM work by hand according to expertness, 1150 to 1725 minutes (19 to 29 hours) were needed and 632 seconds (11 hours) were needed for using Macro. When using PACS work by hand, 2 to 3 minutes were needed and for using Macro, 45 seconds were needed. After applying theses time to the number of studies, when working by hand, 1668 to 2502 minutes (28 to 42 hours) were needed and for using Macro, 625 minutes (10 hours) were needed. Following by these results, it was shown that 1043 to 1877 (17 to 31 hours were saved. Therefore, we could save 45 to 63% for SPM, 62 to 75% for PACS work and 55 to 70% for total brain SPECT processing in 2007. Conclusions: On the basis of the number of studies, there was significant time saved when we applied Macro to brain SPECT processing and also it was shown that even though work is taken a little time, there is a possibility to save lots of time according to the number of studies. It gives time on technologist's side which makes radiological technologist more concentrate for patients and reduce probability of mistake. Appling Macro to brain SPECT processing helps for both of radiological technologists and patients and contribute to improve quality of hospital service.

  • PDF

Understanding the Legal Structure of German Human Gene Testing Act (GenDG) (독일 유전자검사법의 규율 구조 이해 - 의료 목적 유전자검사의 문제를 중심으로 -)

  • Kim, Na-Kyoung
    • The Korean Society of Law and Medicine
    • /
    • v.17 no.2
    • /
    • pp.85-124
    • /
    • 2016
  • The Human gene testing act (GenDG) in Germany starts from the characteristic features of gene testing, i.e. dualisting structure consisted of anlaysis on the one side and the interpretation on the other side. The linguistic distincion of 'testing', 'anlaysis' and 'judgment' in the act is a fine example. Another important basis of the regulation is the ideological purpose of the law, that is information autonomy. The normative texts as such and the founding principle are the basis of the classification of testing types. Especially in the case of gene testing for medical purpose is classified into testing for diagnostic purpose and predictive purpose. However, those two types are not always clearly differentiated because the predictive value of testing is common in both types. In the legal regulation of gene testing it is therefore important to manage the uncertainty and subjectivity which are inherent in the gene-analysis and the judgment. In GenDG the system ensuring the quality of analysis is set up and GEKO(Commity for gene tisting) based on the section 23 of GenDG concretes the criterium of validity through guidelines. It is also very important in the case of gene testing for medical purpose to set up the system for ensurement of procedural rationality of the interpretation. The interpretation of the results of analysis has a wide spectrum because of the consistent development of technology on the one side and different understandings of different subjects who performs gene testings. Therefore the process should include the communication process for patients in oder that he or she could understand the meaning of gene testing and make plans of life. In GenDG the process of genetic counselling and GEKO concretes the regulation very precisely. The regulation as such in GenDG seems to be very suggestive to Korean legal polic concerning the gene testing.

  • PDF

The Effectiveness of CT and MRI Contrast Agent for SUV in 18F-FDG PET/CT Scanning (18F-FDG PET/CT 검사에서 정량분석에 관한 CT와 MRI 조영제의 효과)

  • Cha, Sangyoung;Cho, Yonggwi;Lee, Yongki;Song, Jongnam;Choi, Namgil
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.4
    • /
    • pp.255-261
    • /
    • 2016
  • In this study, among various factors having influence on SUV, we intended to compare and analyze the change of SUV using CT(4 type) and MRI(3 type) contrast agents which are commercialized now. We used Discovery 690 PET/CT(GE) and NEMA NU2 - 1994 PET phantom as experimental equipment. We have conducted a study as follows; first, we filled distilled water to phantom about two-thirds and injected radioisotope(18F-FDG 37 MBq), contrast agent. Second, we mixed CT contrast agent with distilled water and MRI contrast agent with that water separately. And then, we stirred the fluid and filled distilled water fully not to make air bubble. In emission scan, we had 15minutes scanning time after 40 minutes mixing contrast agent with distilled water. In transmission scan, we used CT scanning and its measurement conditions were tube voltage 120 kVp, tube current 40 mA, rotation time 0.5 sec, slice thickness 3.27 mm, DFOV 30 cm. Analyzing results, we set up some ROIs in 10th, 15th, 20th, 25th, 30th slice and measured SUVmean, SUVmax. Consequently, all images mixed 3 types of MRI contrast agent with distilled water have high SUVmean as compared with pure FDG image but there was no statistical significance. In SUVmax, they have high score and there was statistical significance. And other 4 images mixed 4 types of CT contrast agent with distilled water have significance in both SUVmean and SUVmax. Attenuation correction in PET/CT has been executed through various methods to make high quality image. But we figured out that using CT and MRI contrast agents before PET/CT scanning could make distortion of image and decrease diagnostic value. In that reason, we have to sort out the priority of examination in hospital not to disturb other examination's results. Through this process, we will be able to give superior medical service to our customers.

Diagnosis of Pigs Producing PSE Meat using DNA Analysis (DNA검사기법을 이용한 PSE 돈육 생산 돼지 진단)

  • Chung Eui-Ryong;Chung Ku-Young
    • Food Science of Animal Resources
    • /
    • v.24 no.4
    • /
    • pp.349-354
    • /
    • 2004
  • Stress-susceptible pigs have been known as the porcine stress syndrome (PSS), swine PSS, also known as malignant hyperthermia (MH), is characterized as sudden death and production of poor meat quality such as PSE (pale, soft and exudative) meat after slaughtering. PSS and PSE meat cause major economic losses in the pig industry. A point mutation in the gene coding for the ryanodine receptor (RYR1) in porcine skeletal muscle, also known calcium (Ca$^{2+}$) release channel, has been associated with swine PSS and halothane sensitivity. We used the PCR-RFLP(restriction fragment length polymorphism) and PCR-SSCP (single strand conformation polymorphism) methods to detect the PSS gene mutation (C1843T) in the RYR1 gene and to estimate genotype frequencies of PSS gene in Korean pig breed populations. In PCR-RFLP and SSCP analyses, three genotypes of homozygous normal (N/M), heterozygous carrier (N/n) and homozygous recessive mutant (n/n) were detected using agarose or polyacrylamide gel electrophoresis, respectively. The proportions of normal, carrier and PSS pigs were 57.1, 35.7 and 7.1% for Landrace, 82.5, 15.8 and 1.7% far L. Yorkshire, 95.2, 4.8 and 0.0% for Duroc and 72.0, 22.7 and 5.3% for Crossbreed. Consequently, DNA-based diagnosis for the identification of stress-susceptible pigs of PSS and pigs producing PSE meat is a powerful technique. Especially, PCR-SSCP method may be useful as a rapid, sensitive and inexpensive test for the large-scale screening of PSS genotypes and pigs with PSE meat in the pork industry.y.

Canine MR Images from 3T Active-Shield MRI System (3T 능동차폐형 자기공명영상 장비로부터 얻어진 개의 자기공명영상)

  • Choe, Bo-Young;Park, Chi-Bong;Kang, Sei-Kwon;Chu, Myoung-Ja;Kim, Euy-Neyng;Lee, Hyoung-Koo;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.113-124
    • /
    • 2001
  • For veterinary imaging diagnosis, we obtained MR images of the canine brain, spine, kidney and pelvis from 3T MRI system which was equipped with the world first 3T active shield magnet. Spin echo (SE) and fast Spin Echo (FSE) images were obtained from the canine brain, spine, kidney and pelvis of normal and sick dogs using a homemade birdcage and transverse electromagnetic (TEM) resonators operating in quadrature and tuned to 128 MHz. In addition, we employed a homemade saddle shaped RF coil. Typical common acquisition parameters were as follows: matrix=512$\times$512, field of view (FOV)=20cm, slice thickness=3 w, number of excitations (NEX)=1. For T1-weighted MR images, we used TR=500 ms, TE=10 or 17.4 ms. For T2-weighted MR images, we used TR=4000 ms, TE=108 ms. Signal to noise ratio (SNR) of 3T system was measured 2.7 times greater than that of prevalent 1.57 system. The high resolution images acquired in this study represent more than a 4-fold increase in in-plane resolution relative to conventional images obtained with a 20 cm field of view and a 5 mm slice thickness. MR images obtained from 3T system revealed numerous small venous structures throughout the image plane and provided reasonable delineation between gray and white matter The present results demonstrate that the MR images from 3T system could provide better diagnostic quality of resolution and sensitivity than those of 1.5T system. The elevated SNR observed in the 3T high field magnetic resonance imaging can be utilized to acquire images with a level of resolution approaching the microscopic structural level under in vivo conditions. These images represent a significant advance in our ability to examine small anatomical features with noninvasive imaging methods. Moreover, MRI technique could begin to apply for veterinary medicine in Korea.

  • PDF