• Title/Summary/Keyword: Quality Control Factor

검색결과 900건 처리시간 0.043초

자동가스 조절용 DC-MOTOR의 실시간 모니터링 시스템 설계 (Design of the Realtime Monitoring System of DC-MOTOR for Automatic gas Control)

  • 조현섭;민병조;오훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 D
    • /
    • pp.2431-2433
    • /
    • 2001
  • Robust control for DC motor is needed according to the highest precision of industrial automation. It is a quite quality concerning to control temperature of single crystalline growth as it does when you get most of heat treating products. It is also important factor to control temperature when you make the A12O3(single crystalline) used to artificial jewels, glass of watches, heat resistant transparent glasses. Thus, it is a major interest to get the proper temperature in accordance with the time process while you are making mixture of oxygen and hydrogen to have the right temperature. In this paper, we will study of electrical valve positioning system for the gas mixture to improve the quality of products.

  • PDF

전문가 제어기를 이용한 단결정(Al$_2$O$_3$) 성장 제어 (Al$_2$O$_3$ Growth Control Using Expert Hybrid Controller)

  • 조현섭;민병조
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2001년도 춘계학술대회 발표논문집
    • /
    • pp.265-268
    • /
    • 2001
  • Robust control for DC motor is needed according to the highest precision of industrial automation. It is a quite quality concerning to control temperature of single crystalline growth as it does when you get most of heat treating products. It is also Important factor to control temperature when you make the A1203(sing1e crystalline) used to artificial Jewels, glass of watches, heat resistant transparent glasses. Thus, it is a major interest to get the proper temperature in accordance with the time process while you are making mixture of oxygen and hydrogen to have the right temperature. In this paper, we will study of electrical valve positioning system f3r the gas mixture to improve the quality of products.

출입문 개폐에 의한 전동차 객실 CO2 저감효과 분석 (Quantitative Analysis of CO2 Reduction by Door-opening in the Subway Cabin)

  • 권순박;조영민;박덕신;박은영
    • 한국대기환경학회지
    • /
    • 제24권2호
    • /
    • pp.153-161
    • /
    • 2008
  • The guidelines for indoor air quality of public transportations such as subway, train and bus was presented by Korean Ministry of Environment last end of year 2006 based on the great consequence of indoor air quality in daily life. Two main parameters, carbon dioxide($CO_2$) and particulate matters smaller than $10\;{\mu}m(PM_{10})$, were selected as index pollutants for the management of indoor air quality. The former pollutant, $CO_2$, is regarded as index of ventilation status and the major source of $CO_2$ in the train or subway is the exhalation of passengers. It is publically perceived that the high $CO_2$ concentration in a crowded subway will be reduced and ventilated with outdoor air by door-opening taken every 2 or 3 minutes when the train stops each station. However, there has not been any scientific proof and quantitative information on the effect of door-opening on the $CO_2$ reduction by ventilation with outdoor air. In this study, $CO_2$ concentration and number of passengers were measured at each station on the 3 lines of Korail metropolitan subway. In order to evaluate the effect of $CO_2$ reduction by door opening, the theoretical approach using the $CO_2$ balance equation was performed. By comparing the predicted data with monitoring one, the optimum $CO_2$ dilution factor was determined. For the first time, it was quantified that about 35% of $CO_2$ concentration in the subway indoor was removed by the door-opening at each station.

단위 역률을 갖는 대용량 하이브리드 멀티레벨 PWM 정류기 (High Power Hybrid Multilevel PWM Rectifier with Unity Power Factor)

  • 최남섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1187-1189
    • /
    • 2000
  • This paper presents a high power-hybrid multilevel PWM rectifier with unity power factor. The features and advantages of the proposed PWM rectifier can be summarized as follows; 1) It realizes the high power high voltage AC/DC power conversion. 2) It uses no transformer which is bulky and heavy, 3) It has hybrid structure so that switching devices can be effectively utilized, 4) It produces high quality AC current even in high power high voltage applications, 5) The input power factor remains unity by simple modulation index control. The multilevel rectifier is analyzed by using the circuit DQ transformation whereby the characteristics and control equations are obtained.

  • PDF

Analysis, Design, and Implementation of a Single-Phase Power-Factor Corrected AC-DC Zeta Converter with High Frequency Isolation

  • Singh, Bhim;Agrawal, Mahima;Dwivedi, Sanjeet
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권2호
    • /
    • pp.243-253
    • /
    • 2008
  • This paper deals with the analysis, design, and implementation of a single phase AC-DC Zeta converter with high frequency transformer isolation and power factor correction(PFC) in two modes of operation, discontinuous current mode of operation(DCM), and continuous current mode of operation(CCM). A Digital Signal Processor(DSP) based implementation is carried out for validation of the Zeta converter developed design in discontinuous mode of operation. A comparison of both modes of operation is presented for a 1kW power rating from the point of view of steady state and dynamic behavior, power quality, simplicity, control technique, device rating, and converter size. The experimental results of a developed prototype of Zeta converter are presented for validation of the developed design. It is observed that CCM is most suitable for higher power applications where it requires some complex control and sensing of the additional variables.

불평형 및 비선형부하 시 전력품질 향상을 위한 독립형 인버터의 전압제어 기법 (Voltage Control of Stand-Alone Inverter for Power Quality Improvement Under Unbalanced and Non-linear Load)

  • 이우종;조종민;차한주
    • 전기학회논문지
    • /
    • 제65권4호
    • /
    • pp.567-575
    • /
    • 2016
  • This paper proposed the voltage control of stand-alone inverter for power quality improvement under unbalanced and non-linear load. The 3-phase DC-AC inverter controls CVCF(Constant Voltage Constant Frequency) and selective harmonic eliminate method in stand-alone mode by PR controller, and the stand-lone inverter supplies stable sinusoidal voltage to balanced, unbalanced and non-linear loads. The total harmonic distortion(THD) of line-to-line load voltage($V_{LL}$) is 1.2% in the balanced load. THD of $V_{LL}$ is reduced from 5.2% to 1.4% and 6.7% to 3.5%, respectively unbalanced and non-linear load. The stand-alone inverter can be supplies sinusoidal balanced voltage to unbalanced load because the voltage unbalanced factor(VUF) of $V_{LL}$ is reduced from 5.2% to 1.4% in the unbalanced load. Feasibility of control method for a stand-alone inverter will be verified through 30kW stand-alone inverter system.

An Image Quality Requirement Quantified Control Method in Display Development Life Cycle

  • Xue, Liqin;Zou, Xuecheng
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.660-664
    • /
    • 2006
  • A novel quantified method based on requirement analysis of image quality to improve display image quality was proposed. Nowadays, the image quality was limited by the poor understanding of the image quality requirement, which led to the critical factors of image quality could not be controlled during display development. Our method was set up to resolve this problem by clarifying the relationship between the image quality level and the effect factors in image processing. Moreover, the subjective factors were eliminated extremely by the image quality quantification. The method was applied in the RPTV development life cycle and its efficiency was demonstrated.

  • PDF

장면 전환을 고려한 효과적인 전송률 제어 알고리즘 (An Efficient Bit Allocation Scheme Considering Scene Change)

  • 이우용;나종범
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송공학회 1995년도 학술대회
    • /
    • pp.109-112
    • /
    • 1995
  • A rate control strategy in the MPEG is critical to the quality of the reconstructed image sequence. In this paper, were propose a rate control algorithm which can improve the coding performance for a given bit constraint. The proposed algorithm use the distortion-rate curve for the fine adjustment of the quantization scaling factor of each region. This algorithm can also handle the problem due to scene change effectively. It can be easily applicable to existing MPEG coders. Simulation results show that the performance for the algorithm is better than the rate control algorithm in the MPEG-2 TM5.

Intelligent cooling control for mass concrete relating to spiral case structure

  • Ning, Zeyu;Lin, Peng;Ouyang, Jianshu;Yang, Zongli;He, Mingwu;Ma, Fangping
    • Advances in concrete construction
    • /
    • 제14권1호
    • /
    • pp.57-70
    • /
    • 2022
  • The spiral case concrete (SCC) used in the underground powerhouse of large hydropower stations is complex, difficult to pour, and has high requirements for temperature control and crack prevention. In this study, based on the closed-loop control theory of "multi-source sensing, real analysis, and intelligent control", a new intelligent cooling control system (ICCS) suitable for the SCC is developed and is further applied to the Wudongde large-scale underground powerhouse. By employing the site monitoring data, numerical simulation, and field investigation, the temperature control quality of the SCC is evaluated. The results show that the target temperature control curve can be accurately tracked, and the temperature control indicators such as the maximum temperature can meet the design requirements by adopting the ICCS. Moreover, the numerical results and site investigation indicate that a safety factor of the spiral case structure was sure, and no cracking was found in the concrete blocks, by which the effectiveness of the system for improving the quality of temperature control of the SCC is verified. Finally, an intelligent cooling control procedure suitable for the SCC is proposed, which can provide a reference for improving the design and construction level for similar projects.

위상잡음을 개선한 Ka-band 위성 중계기용 Engineering Model 발진기의 설계 (Design of Engineering Model Oscillator with Low Phase Noise for Ka-band Satellite Transponder)

  • 류근관;이문규;염인복;이성팔
    • 한국전자파학회논문지
    • /
    • 제13권1호
    • /
    • pp.74-79
    • /
    • 2002
  • 본 논문에서는 Ka-band 위성 중계기용 국부 발진기에 사용하게 될 전압제어 발진기의 EM(Engineering Model)을 비선형 방법으로 설계하였다. 전압제어 발진기의 위상잡음을 개선하기 위하여 공진기로 사용되는 유전체 공진기와 결합하는 마이크로스트립 라인을 high impedance inverter로 구현함으로써 공진회로의 quality factor를 우수하게 유지하여 능동소자에 전달되도록 하였다. 개발된 전압제어 발진기는 0~12 V의 제어전압으로 9.7965~9.8032 GHz의 튜닝범위를 가지며 공급전력은 8V, 17mA를 필요로 한다. 제작된 전압제어 발진기의 위상잡음은 -96.51 dBc/Hz ⓐ10 KHz와 -116.5 dBc/Hz ⓐ100 KHz의 특성을 나타내며 출력전력은 7.33 dBm을 얻었다.