• 제목/요약/키워드: Quadrant photodetector

검색결과 4건 처리시간 0.017초

Experimental Investigation of Output Current Variation in Biased Silicon-based Quadrant Photodetector

  • Liu, Hongxu;Wang, Di;Li, Chenang;Jin, Guangyong
    • Current Optics and Photonics
    • /
    • 제4권4호
    • /
    • pp.273-276
    • /
    • 2020
  • We report on the relationship between output current for quadrant photodetector (QPD) and bias voltage in silicon-based p-i-n (positive-intrinsic-negative) QPD examined using millisecond pulse laser (ms pulse laser) irradiation. The mechanism governing the relationship was further studied experimentally. The output current curves were obtained by carrying out QPD under different bias voltages (0-40 V) irradiated by ms pulse laser. Compared to other photodetectors, the relaxation was created in the output current for QPD which is never present in other photodetectors, such as PIN and avalanche photodetector (APD), and the maximum value of relaxation was from 6.8 to 38.0 ㎂, the amplitude of relaxation increases with bias value. The mechanism behind this relaxation phenomenon can be ascribed to the bias voltage induced Joule heating effect. With bias voltage increasing, the temperature in a QPD device will increase accordingly, which makes carriers in a QPD move more dramatically, and thus leads to the formation of such relaxation.

4분할 광 검출기 상의 광점 크기가 변위 측정감도에 미치는 영향 (Effect of the Incident Optical Spot Size Upon the Quadrant Photodetector on the Optical Displacement Detection Sensitivity)

  • 이은중;이진우;고태준
    • 한국자기학회지
    • /
    • 제18권2호
    • /
    • pp.71-74
    • /
    • 2008
  • 본 논문에서는 4분할 광 검출기 상에 입사된 광점의 크기에 따른 optical beam deflection방식에서의 변위 측정감도의 변화에 대해 살펴보았다. 3mW의 헬륨-네온 레이저를 사용하여 optical beam deflection방식의 광학적 변위 측정 장치를 제작하였으며 광 검출기에 도달하는 광점의 크기를 변화시켜가며 제작된 변위 측정 장비가 나타내는 변위 측정감도를 관찰하였다. 또한 광 검출기에 도달하는 optical beam power를 원형의 균일한 분포를 지닌 광점으로 설정하여 광점 크기의 변화에 따른 변위 측정감도를 계산하였다. 측정된 결과와 계산을 통하여 검출기 상에 입사하는 광점의 크기가 작을수록 변위 측정감도가 증가함을 알 수 있었으며 이는 나노미터 급의 변위측정 장비 개발에 있어 광 검출기에 도달하는 광점의 크기를 최소화함으로써 변위 측정감도를 최적화 할 수 있음을 나타낸다.

펄스 반복 주파수 코드에 동기된 출력 가변형 레이저 다이오드 드라이버 구현 (Implementation of the Variable Output Laser Diode Driver Synchronized with a Pulse Repetition Frequency Code)

  • 이영주;김용평
    • 전기학회논문지
    • /
    • 제64권5호
    • /
    • pp.746-750
    • /
    • 2015
  • In this paper, we propose a simulator to evaluate the performance of the semi-active laser guidance or the quadrant photodetector and to simulate the laser power reflected from a target. The laser pulse repetition frequency was generated and synchronized with the laser pulse repetition(PRF) code. To evaluate the performances of the proposed methods, we implemented a prototype system and performed experiments. As a result, the generated high voltage was variable in the range of DC 3V to 340V and has the rate of change of 2000 V/s. PRF code can be generated within 50ms ∼ 100ms and the error is implemented within 0.3ns. The laser output is synchronized with the PRF code and has a dynamic range of 23.6dB.

반능동형 레이저 유도 추적에 적합한 레이저 펄스 반복 주파수 검출을 위한 디지털 신호처리 보드 구현 및 표적 좌표 최적화 (Implementation of Digital Signal Processing Board Suitable for a Semi-active Laser Tracking to Detect a Laser Pulse Repetition Frequency and Optimization of a Target Coordinates)

  • 이영주;김용평
    • 전기학회논문지
    • /
    • 제64권4호
    • /
    • pp.573-577
    • /
    • 2015
  • In this paper, we propose a signal processing board suitable for a semi-active laser tracking to detect an optical signal generated from the laser target designator by applying an analog trigger signal, the quadrant photodetector and a high speed ADC(analog-digital converter) sampling technique. We improved the stability by applying the averaging method to minimize the measurement error of a gaussian pulse. To evaluate the performances of the proposed methods, we implemented a prototype board and performed experiments. As a result, we implemented a frequency counter with an error 14.9ns in 50ms. PRF error code has a stability of less than 1.5% compared to the NATO standard. Applying the three point averaging method to ADC sampling, the stability of 28% in X-axis and 22% in Y-axis than one point sampling was improved.