• Title/Summary/Keyword: Qp/Qs ratio

Search Result 26, Processing Time 0.025 seconds

Measurement of Shunt Amount Using Radionuclide Angiocardiography: Accuracy According to Level of Shunt and Associated Lesion (방사성 동위원소 심혈관 조영술을 이용한 단락량 측정법: 정확성에 영향을 미치는 인자)

  • Kim, Yang-Min
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.4
    • /
    • pp.200-204
    • /
    • 2006
  • Purpose: Determination of pulmonary to systemic blood flow ratio (QP/QS) is important for the management of patients with left-to-right shunt. This study was performed to assess the agreement of Qp/Qs ratio using the radionuclide method and oxymetry, to investigate the factors influencing the agreement, and to know how interchangeable the results of each technique. Materials and Methods: We compared the Qp/Qs measured by single-pass radionuclide angiocardiography and oxymetry during catheterization in 207 patients who underwent both studies. In radionuclide method, Qp/Qs was calculated from the pulmonary time-activity curves using a gamma variate fit. The correlation and Bland-Altman analysis were performed according to the levels of shunt and associated lesions. Results: The mean Qp/Qs was $1.83{\pm}0.50$ by radionuclide, and $1.74{\pm}0.51$ by oxymetry. The overall correlation coefficient was 0.86(p<0.001), and Bland-Altman range of agreement encompassing 4SD was 1.05. For atrial septal defect, ventricular septal defect, patent ductus arteriosus, tricuspid and mitral insufficiency, the correlation coefficient was 0.78, 0.90, 0.84, 0.63 and 0.44, and Bland-Altman range was 1.51, 0.74, 0.96, 1.57, and 1.50, respectively. Conclusion: There is good agreement but wide variance between the Qp/Qs ratios by radionuclide method and oxymetry. Associated atrioventricular valvar insufficiency decreases the correlation coefficient and widens the variance. Wide overall variance suggests that Qp/Qs measurements by two techniques should not be used interchangeably.

Evaluation of echocardiographic markers in dogs with patent ductus arteriosus after ductal closure

  • Park, Jong-In;Suh, Sang-IL;Hyun, Changbaig
    • Korean Journal of Veterinary Research
    • /
    • v.56 no.4
    • /
    • pp.209-213
    • /
    • 2016
  • This study evaluated several known echocardiographic markers related to the assessment of severity in dogs with patent ductus arteriosus (PDA) after the closure of ductus arteriosus (DA). Forty-two dogs with patent ductus arteriosus were enrolled in this study. Evaluated echocardiographic markers were left atrial to aortic root ratio, left ventricular end-diastolic dimension to aortic root ratio, indexed left ventricular end-diastolic and end-systolic dimensions, end-diastolic and end systolic volume index, pulmonic flow to systemic flow (Qp/Qs) ratio, velocities of pulmonary regurgitant and systolic jets, pulmonary flow profiles and the presence of mitral regurgitation. Those markers were evaluated before, 1 day, and 30 days after the closure of DA. Statistically significant changes in some echocardiographic markers (i.e., Qp/Qs) were observed. Although several studies in human and dogs have evaluated the clinical outcome of PDA occlusion using several echocardiographic markers, this study has firstly evaluated all echocardiographic markers known to be useful for assessing the clinical outcome of PDA occlusion in human, and has demonstrated that those markers including the Qp/Qs and pulmonary flow profiles were useful in evaluating of clinical outcome of PDA in dogs and the reduction of LA and LV preload after ductal closure could dramatically reduce after successful ductal occlusion of PDA in dogs.

Radionuclide Angiocardiographic Evaluation of Left-to-Right Cardiac Shunts: Analysis of Time-Activity Curves (핵의학적 심혈관 촬영술에 의한 좌우 심단락의 진단 : 시간-방사능 곡선의 분석)

  • Kim, Ok-Hwa;Bahk, Yong-Whee;Kim, Chi-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.21 no.2
    • /
    • pp.155-165
    • /
    • 1987
  • The noninvasive nature of the radionuclide angiocardiography provided a useful approach for the evaluation of left-to-right cardiac shunts (LRCS). While the qualitative information can be obtained by inspection of serial radionuclide angiocardiograms, the quantitative information of radionuclide angiocardiography can be obtained by the analysis-of time-activity curves using advanced computer system. The count ratios method and pulmonary-to-systemic flow ratio (QP/QS) by gamma variate fit method were used to evaluate the accuracy of detection and localization of LRCS. One hundred and ten time-activity curves were analyzed. There were 46 LRCS (atrial septal defects 11, ventricular septal defects 22, patent ductus arteriosus 13) and 64 normal subjects. By computer analysis of time-activity curves of the right atrium, ventricle and the lungs separately, the count ratios modified by adding the mean cardiac transit time were calculated in each anatomic site. In normal subjects the mean count ratios in the right atrium, ventricle and lungs were 0.24 on average. In atrial septal defects, the count ratios were high in the right atrium, ventricle and lungs, whereas in ventricular septal defects the count ratios were higher only in the right ventricle and lungs. Patent ductus arteriosus showed normal count ratios in the heart but high count ratios were obtained in the lungs. Thus, this count ratios method could be separated normal from those with intra cardiac or extracardiac shunts, and moreover, with this method the localization of the shunt level was possible in LRCS. Another method that could differentiate the intracardiac shunts from extracardiac shunts was measuring QP/QS in the left and right lungs. In patent ductus arteriosus, the left lung QP/QS was higher than those of the right lung, whereas in atrial septal defects and ventricular septal defects QP/QS ratios were equal in both lungs. From this study, it was found that by measuring QP/QS separately in the lungs, intracardiac shunt could be differenciated from extracardiac shunts.

  • PDF

The Correlation between Cardiac Catheterization Data and Defect Size in Ventricular Septal Defect (심실중격결손증에서 술전 심도자검사치와 결손크기의 상관관계에 대한 연구)

  • 정상조
    • Journal of Chest Surgery
    • /
    • v.23 no.3
    • /
    • pp.430-437
    • /
    • 1990
  • We clinically evaluated 121 cases of ventricular septal defect which we operated from April, 1986 to December, 1989 at Inha General Hospital, Seong-Nam, Department of Thoracic and Cardiovascular Surgery, College of Medicine, Inha University. These patients were occupied 54.8% of all congenital heart diseases operated on its same period. Of the 121 patients, 63 patients were male[52.1%] and 58 patients were female[47.9i]. The two most common symptoms were frequent upper respiratory infection and dyspnea on exertion. By Kirklin s anatomical classification, type I constituted 34.7%, type II 61.98%, type III 0.03% and type IV not occupied. Associated cardiac anomalies were found in 34 cases, and PDA was most common associated anomaly, occupied in 22 cases. On the cardiac catheterization data, there were statistically significant correlation between VSD size[cm2 /BSAm2] and systolic pulmonary arterial pressure[sPAP], pulmonary to systemic flow ratio[Qp/Qs] & pulmonary to systemic pressure ratio[Pp/Ps] respectively, Type II [r=0.53, p<0.01] was more correlated than type I [r=0.49, p<0.05] between VSD size and Qp /Qs. We could not found the correlationship between age and Qp/Qs [Type I; r=0.16, Type II; r=-0.15] All cases were operated under cardiopulmonary bypass and 58 cases[46.3%] were operated through the right atrial approach, and 34 cases[28.1%] through the pulmonary arterial approach. Operative mortality rate was 4.13%[5 cases].

  • PDF

Surgical Repair of Secundum Type Atrial Septal Defects Using Extracorporeal Circulation in 48 Patients (심방중격 결손증의 외과적 완전교정 48례 보고)

  • 서경필
    • Journal of Chest Surgery
    • /
    • v.10 no.2
    • /
    • pp.268-273
    • /
    • 1977
  • During the period from March, 1963, to November, 1977, forty-eight patients with secundum type atrial septal defects have undergone surgical repair using cardiopulmonary bypass with a pump oxygenator at the Seoul National University Hospital. Twenty-six [55 percent] of the patients were females and Twenty-two [45 percent] were males. The patients varied in age from 3 years to 51 years. We have divided secundum defects into three types. These are: 1] the high defect; 2] Ovale type defect; and 3] low defect including the defect in the area of the coronary sinus. An ovale type defect was present in forty-one cases [85 percent]. Partial anomalous pulmonary venous connections were present in two patients in the high defect group. All of the forty-eight patients had had right heart catheterization before operation. The pulmonary to systemic flow ratio [Qp/Qs] was determined in our 38 patients. The Qp/Qs was less than 1.5/1 in only five of the 38 patients. Among the 33 patients with moderate and severe left-to-right shunts [Qp/Qs 1.6-3.5/1], the systolic pulmonary artery pressures. ranged from 30 to 80 mm Hg. Large left-to-right shunts [Qp/Qs>3.6/1] were present in 13 patients. The postoperative complications occurred in 13 patients [27. 1 percent]. Postoperative wound infections were the most frequent complications being present in 6 patients [12.5%]. Forty-six of the patients with secundum atrial septal defects survived surgical repair of their defects. Thus the hospital mortality of surgery was 4.2 percent. The causes of death in the early postoperative period were: 1] low cardiac output syndrome related to severe pulmonary hypertension in one case; and 2] postoperative several bleeding in one case.

  • PDF

Radionuclide Angiocardiography in Cogenital Heart Disease (선천성심질환(先天性心疾患)에서 방사성(放射性) 동위원소심혈관조영술(同位元素心血管造影術) -좌우단락(左右短絡)의 발견(發見)과 정량(定量)에 대하여-)

  • Kim, Byung-Chan;Noh, Byung-Suk;Sohn, Myung-Hee;Song, Ho-Yung;Kim, Chong-Soo;Kim, Jong-Keon;Choi, Ki-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.20 no.1
    • /
    • pp.85-91
    • /
    • 1986
  • In detecting, localizing and quantitating cardiac shunts, radionulide angiocardiography has been known to be a simple and safe method compared with oxymetry method. To ascertain the availability of the results obtained by radionuclide angiocardiography for the evaluation of patients with cardiac shunt, author compared the Qp/Qs ratios(pulmonary to systemic flow ratios) obtained by radionuclide angiocardiography with the results of oximetry method in 40 patients with left to right shunt, and also compared the results of radionuclide angiocardiography examined before and after shunt operation in 8 patients. The results were as follows: 1) Of the 161 patients examined radionuclide angiocardiography, 98 were thought to have cardiac shunts: right to left shunt id 27, left to right shunt in 71. Of the 71 patients who had left to right shunt, 40 who were examined with both radionuclide angiocardiography and oxymetry had following congenital heart disease: VSD in 21, ASD in 9 and PDA in 10. 2) Comparison of Qp/Qs ratios obtained during radionuclide angiocardiography and oxymetry revealed good correlation (linear regression analysis yielded correlation coefficient of 0.80) in 32 patients whose Qp/Qs ratio obtained during oxymetry were below 3.0, but very poor correlation in 8 patients whose Qp/Qs ratios were above 3.0 3) Radionuclide angiocardiography is a relatively safe and simple method in postoperative evaluation of patients with cardiac shunt.

  • PDF

A Clinical Study on Postoperative Changes of Electrocardiographic Findings in Patients with PDA (동맥관개존증의 술후 심전도변화에 관한 임상적 연구)

  • Lee, Sin-Yeong;Kim, Geun-Ho
    • Journal of Chest Surgery
    • /
    • v.19 no.1
    • /
    • pp.43-49
    • /
    • 1986
  • At the Department of Thoracic and Cardiovascular Surgery, Hanyang university, from 1976 to 1984, 102 patients operated for isolated patent ductus arteriosus were studied. The correlation between the degree of left ventricular hypertrophy [LVH] and hemodynamic data, and postoperative changes of electrocardiographic findings were evaluated. The following results were obtained; [1] Of 102 patients with isolated patent ductus arteriosus, 78 patients [76.5%] were found to have LVH by EKG, preoperatively. [2] The patients with LVH had higher incidence of respiratory infection [79.4%] compared to patients without LVH. [3] Frequent physical findings in the patients with LVH were precordial bulging and P2 accentuation on auscultation. The typical continuous machinery murmur was not different in two group with or without LVH. [4] 66.1% of patients with LVH showed more than 56% of cardiothoracic ratio [CTR] on simple chest X-ray. 56.5% of patients without LVH showed less than 50% of CTR. [5] In the patients found to have LVH by EKG, the correlation between values of Svl+Rv6 and Qp/Qs in hemodynamic data was correlation coefficient 0.57 and between CTR and Qp/Qs was correlation coefficient 0.51. [6] In patent ductus arteriosus with LVH following surgery, the values of Svl+Rv6 was changed from preoperative 153.6$\pm$42.78% to 107.7$\pm$19.58% within 3 months and to 80.4$\pm$12.22%, which is within normal range of Svl+Rv6 on EKC, after 6 months.

  • PDF

Descending Aorta Index and Pulmonary Index in Infants Comparison between Atrioventricular Septal Defects, At ial Septal Defects and Ventricular Septal Defects (심방실 중격 결손증에서의 하행대동맥, 폐동맥 지수)

  • 안재호
    • Journal of Chest Surgery
    • /
    • v.26 no.8
    • /
    • pp.591-594
    • /
    • 1993
  • To clarify the apparent hypoplasia of the descending aorta in infants with atrioventricular septal defect[AVSD] patients, we reviewed the catheterization data and angiograms of 34 consecutive patients with AVSD less than 1 year of age who underwent repair at our institution since 1985. We compared them to 10 patients with Atrial Septal Defect[ASD] and 10 patients with Ventricular Septal Defect[VSD] who were matched for age, size and Qp/Qs. The Descending Aorta Index [DAI] of the AVSD group was not different from the VSD or ASD groups, [147.9$\pm$ 34.8 mm2/m2 versus 158.6$\pm$ 31.5 mm2/m2 and 153.2$\pm$ 43.1 mm2/m2].However, the Pulmonary Artery Index [PAI] of the AVSD group was significantly larger than the other groups [684.3$\pm$ 170.7 mm2/m2 versus 454.1$\pm$ 109.1 mm2/m2 and 534.9$\pm$ 148.4 mm2/m2][p<0.05], as was the ratio of PAI/DAI in the AVSD group [4.99$\pm$ 1.77 versus 2.89$\pm$ 0.81 and 3.6$\pm$ 0.92][p<0.05]. Despite similar Qp/Qs ratios, both the mean PA pressure and the Rp/Rs in the AVSD group was higher than the VSD and ASD groups: 43.1$\pm$ 15.6 mmHg versus 29$\pm$ 11.6 mmHg and 24$\pm$ 18.1 mmHg [p<0.05], and 0.27$\pm$ 0.22 versus 0.14$\pm$ 0.03 and 0.11$\pm$ 0.05 [p<0.05] respectively. The apparent hypoplasia of the descending aorta in infants with AVSD is an illusion created by the abnormally large pulmonary arteries, which are significantly larger than in patients with ASDs or VSDs.

  • PDF

Aoric Valve Lesion in Type I Ventricular Septal Defect (제1형 심실중격결손에서 대동맥판막 병변)

  • 김관창;임홍국;김웅한;김용진;노준량;배은정;노정일;윤용수;안규리
    • Journal of Chest Surgery
    • /
    • v.37 no.6
    • /
    • pp.492-498
    • /
    • 2004
  • Background: In this study, we investigated the risk factors for the development or progression of aortic regurgitation(AR) in patients with type I ventricular septal defect (VSD) to determine the optimal surgical timing and strategy. Material and Method: Three-hundred and ten patients with type I VSD with or without AR were included. The mean of age was 73.7$\pm$114.7 (1-737) months. One hundred and eighty six patients (60%) had no AR, 83 (27%) had mild AR, 25 (8%) had moderate AR and 16 (5%) had severe AR. Aortic valve was repaired in 5 patients and replaced in 11 patients with closure of VSD in the first operation. Four patients required redo aortic valve repair and 11 patients required redo aortic valve replacement. Age at operation, association with aortic valve prolapse, Qp/Qs, systolic pulmonary arterial pressure, VSD size and systolic pulmonary artery to aortic pressure ratio(s[PAP/AP]) were included as risk factors analysis for the development of AR. The long-term result of aortic valve repair and aortic valve replacement were compared. Result: Older age at operation, association with aortic valve prolapse, high Qp/Qs, and s[PAP/AP] were identified as risk factors for the development of AR (p<0.05, Table 2). The older the patient at the time of operation, the higher the severity of preoperative AR and the incidence of postoperative AR (p<0.05, Table 1, Fig. 1). For the older patients at operation, aortic valve repair had higher occurrence of AR compared to those who had aortic valve replacement (p<0.05, Fig. 2). Conclusion: From the result of this study, we can concluded that early primary repair is recommended to decrease the progression of AR. Aortic valve repair is not always a satisfactory option to correct the aortic valve pathology, which may suggest that aortic valve replacement should be considered when indicated.

Total correction of TOF using monocusp bearing outflow patch (단일판첨을 내재한 우심실유출로 Patch 를 이용한 활로 4 징증의 교정수)

  • 박이태
    • Journal of Chest Surgery
    • /
    • v.17 no.4
    • /
    • pp.636-643
    • /
    • 1984
  • For the purpose of avoiding postoperative massive pulmonary insufficiency after transannular outflow tract reconstruction in patients with tetralogy of Fallot, we have used monocusp bearing outflow patch since June 1983. Right heart catheterization and pulmonary arteriography were performed in 7 patients among the total 11 patients corrected with monocusp bearing outflow patch during postoperative 14th day to 22nd day. Particular attention was paid to the evaluation of the pulmonary valve competence, and the results were; 1.One patient died of acute renal failure secondary to low cardiac output and the operative mortality was 9.1%. 2.The average PRV/FA ratio was 0.491 and the average systolic pressure gradient between right ventricle and pulmonary artery was 17.7mmHg. The average Qp/Qs was 1.13. 3.Inspite of using monocusp bearing outflow patch, the hemodynamic and pulmonary arteriographic results were unsatisfactory in respect to pulmonary valve competence.

  • PDF