• Title/Summary/Keyword: QP

Search Result 235, Processing Time 0.023 seconds

The First QP Decision Algorithm for the H.264/AVC (H.264/AVC를 위한 초기 QP 결정 알고리즘)

  • Kwon, Soon-Young;Lee, Sang-Heon;Lee, Dong-Ha
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2007.06a
    • /
    • pp.204-205
    • /
    • 2007
  • H.264/AVC는 적응적인 비트율 제어(Adaptive Rate Control) 기법을 제공한다. 본 논문에서는 H.264/AVC 부호화기에서 첫 번째 프레임의 QP값을 결정하는 새로운 알고리즘을 제안한다. 실험결과 기존 알고리즘으로는 비트율 제어가 불가능 했던 영상을 효율적으로 비트율 제어를 하였고 기존의 방법보다 평균 PSNR의 향상을 확인하였다. 화면 사이의 화질 변화 폭을 줄임으로써 주관적인 화질 또한 향상하였다.

  • PDF

Fast Training of Structured SVM Using Fixed-Threshold Sequential Minimal Optimization

  • Lee, Chang-Ki;Jang, Myung-Gil
    • ETRI Journal
    • /
    • v.31 no.2
    • /
    • pp.121-128
    • /
    • 2009
  • In this paper, we describe a fixed-threshold sequential minimal optimization (FSMO) for structured SVM problems. FSMO is conceptually simple, easy to implement, and faster than the standard support vector machine (SVM) training algorithms for structured SVM problems. Because FSMO uses the fact that the formulation of structured SVM has no bias (that is, the threshold b is fixed at zero), FSMO breaks down the quadratic programming (QP) problems of structured SVM into a series of smallest QP problems, each involving only one variable. By involving only one variable, FSMO is advantageous in that each QP sub-problem does not need subset selection. For the various test sets, FSMO is as accurate as an existing structured SVM implementation (SVM-Struct) but is much faster on large data sets. The training time of FSMO empirically scales between O(n) and O($n^{1.2}$), while SVM-Struct scales between O($n^{1.5}$) and O($n^{1.8}$).

  • PDF

Tunneling Spectra in Organic Cu-Pc/$Bi_2Sr_2CaCu_2O_{8+\delta}$ Tunnel Junctions

  • Kim, Sunmi;E, Jungyoon;Lee, Kiejin;Ishbas, Takayuki;Lee, Yang-San
    • Progress in Superconductivity
    • /
    • v.3 no.1
    • /
    • pp.41-44
    • /
    • 2001
  • We report the current transport properties of a normal metal/organic conductor/ superconductor tunnel junction as a novel high- $T_{c}$ superconducting three terminal device. The organic copper (II) phthalocyanine (Cu-Pc) layer was used far a polaronic quasiparticle (QP) injector. The injection of polaronic QP from the Cu-Pc interlayer into a superconductor $Bi_2$$Sr_2$$CaCu_2$ $O_{8+}$ $\delta$/(BSCCO) thin film generated a substantially larger nonequilibrium effect as compared to the normal QP injection current. The tunneling spectroscopy of an Au/cu-PC/BSCCO junction exhibited a zero bias conductance peak which may be due to Andreev reflection at a Cu-Pc/d-wave superconductor junction.n..

  • PDF

Hardware Design of Rate Control for H.264/AVC Real-Time Video Encoding (실시간 영상 부호화를 위한 H.264/AVC의 비트율 제어 하드웨어 설계)

  • Kim, Changho;Ryoo, Kwangki
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.12
    • /
    • pp.201-208
    • /
    • 2012
  • In this paper, the hardware design of rate control for real-time video encoded is proposed. In the proposed method, a quadratic rate distortion model with high-computational complexity is not used when quantization parameter values are being decided. Instead, for low-computational complexity, average complexity weight values of frames are used to calculate QP. For high speed and low computational prediction, the MAD is predicted based on the coded basic unit, using spacial and temporal correlation in sequences. The rate control is designed with the hardware for fast QP decision. In the proposed method, a quadratic rate distortion model with high-computational complexity is not used when quantization parameter values are being decided. Instead, for low-computational complexity, average complexity weight values of frames are used to calculate QP. In addition, the rate control is designed with the hardware for fast QP decision. The execution cycle and gate count of the proposed architecture were reduced about 65% and 85% respectively compared with those of previous architecture. The proposed RC was implemented using Verilog HDL and synthesized with UMC $0.18{\mu}m$ standard cell library. The synthesis result shows that the gate count of the architecture is about 19.1k with 108MHz clock frequency.

SOME CURVATURE CONDITIONS OF n-DIMENSIONAL QR-SUBMANIFOLDS OF (p-1) QR-DIMENSION IN A QUATERNIONIC PROJECTIVE SPACE QP(n+p)/4

  • Pak, Jin-Suk;Sohn, Won-Ho
    • Bulletin of the Korean Mathematical Society
    • /
    • v.40 no.4
    • /
    • pp.613-631
    • /
    • 2003
  • The purpose of this paper is to study n-dimensional QR-submanifolds of (p - 1) QR-dimension in a quaternionic projective space $QP^{(n+p)/4}$ and especially to determine such submanifolds under the curvature conditions appeared in (5.1) and (5.2).

Incremental Support Vector Learning Method for Function Approximation (함수 근사를 위한 점증적 서포트 벡터 학습 방법)

  • 임채환;박주영
    • Proceedings of the IEEK Conference
    • /
    • 2002.06c
    • /
    • pp.135-138
    • /
    • 2002
  • This paper addresses incremental learning method for regression. SVM(support vector machine) is a recently proposed learning method. In general training a support vector machine requires solving a QP (quadratic programing) problem. For very large dataset or incremental dataset, solving QP problems may be inconvenient. So this paper presents an incremental support vector learning method for function approximation problems.

  • PDF

REAL n-DIMENSIONAL QR-SUBMANIFOLDS OF MAXIMAL QR-DIMENSION IMMERSED IN QP(n+p)/4

  • Kim, Hyang-Sook;Kwon, Jung-Hwan;Pak, Jin-Suk
    • Communications of the Korean Mathematical Society
    • /
    • v.24 no.1
    • /
    • pp.111-125
    • /
    • 2009
  • The purpose of this paper is to study n-dimensional QR-submanifolds of (p-1) QR-dimension immersed in a quaternionic projective space $QP^{(n+p)/4}$ of constant Q-sectional curvature 4 and especially to determine such submanifolds under the additional condition concerning with shape operator.

Modified Fixed-Threshold SMO for 1-Slack Structural SVMs

  • Lee, Chang-Ki;Jang, Myung-Gil
    • ETRI Journal
    • /
    • v.32 no.1
    • /
    • pp.120-128
    • /
    • 2010
  • In this paper, we describe a modified fixed-threshold sequential minimal optimization (FSMO) for 1-slack structural support vector machine (SVM) problems. Because the modified FSMO uses the fact that the formulation of 1-slack structural SVMs has no bias, it breaks down the quadratic programming (QP) problems of 1-slack structural SVMs into a series of smallest QP problems, each involving only one variable. For various test sets, the modified FSMO is as accurate as existing structural SVM implementations (n-slack and 1-slack SVM-struct) but is faster on large data sets.

Surgical Repair of Secundum Type Atrial Septal Defects Using Extracorporeal Circulation in 48 Patients (심방중격 결손증의 외과적 완전교정 48례 보고)

  • 서경필
    • Journal of Chest Surgery
    • /
    • v.10 no.2
    • /
    • pp.268-273
    • /
    • 1977
  • During the period from March, 1963, to November, 1977, forty-eight patients with secundum type atrial septal defects have undergone surgical repair using cardiopulmonary bypass with a pump oxygenator at the Seoul National University Hospital. Twenty-six [55 percent] of the patients were females and Twenty-two [45 percent] were males. The patients varied in age from 3 years to 51 years. We have divided secundum defects into three types. These are: 1] the high defect; 2] Ovale type defect; and 3] low defect including the defect in the area of the coronary sinus. An ovale type defect was present in forty-one cases [85 percent]. Partial anomalous pulmonary venous connections were present in two patients in the high defect group. All of the forty-eight patients had had right heart catheterization before operation. The pulmonary to systemic flow ratio [Qp/Qs] was determined in our 38 patients. The Qp/Qs was less than 1.5/1 in only five of the 38 patients. Among the 33 patients with moderate and severe left-to-right shunts [Qp/Qs 1.6-3.5/1], the systolic pulmonary artery pressures. ranged from 30 to 80 mm Hg. Large left-to-right shunts [Qp/Qs>3.6/1] were present in 13 patients. The postoperative complications occurred in 13 patients [27. 1 percent]. Postoperative wound infections were the most frequent complications being present in 6 patients [12.5%]. Forty-six of the patients with secundum atrial septal defects survived surgical repair of their defects. Thus the hospital mortality of surgery was 4.2 percent. The causes of death in the early postoperative period were: 1] low cardiac output syndrome related to severe pulmonary hypertension in one case; and 2] postoperative several bleeding in one case.

  • PDF