• 제목/요약/키워드: QCM biosensor

검색결과 16건 처리시간 0.023초

압전 수정 결정 미량 천평[PZ QCM] 바이오센서의 원리와 응용 (The Theory and Application or Piezoelectric Quartz Crystal Microbalance[PZ QCM] for Biosensor)

  • 김의락
    • KSBB Journal
    • /
    • 제18권2호
    • /
    • pp.79-89
    • /
    • 2003
  • This article contains an overview of acoustic wave devices, the theory and application of piezoelectric quartz crystal microbalances(PZ QCM), clinical analysis, gas phase detection, DNA biosensors, drug analysis, food microbial analysis and environmental analysis.

헵토글로빈 측정을 위한 수정미소저울 바이오센서 개발 (QCM biosensor for the determination of haptoglobin)

  • 김성일;이현정;박순혁;방현수;이진아;최석정
    • 센서학회지
    • /
    • 제16권2호
    • /
    • pp.132-141
    • /
    • 2007
  • The purpose this research is to develop QCM (quartz crystal microbalance) biosensor for the determination of haptoglobin. Haptoglobin is an acute-phase protein with a hemoglobin-binding activity and has a potential to be used as a biomarker for infection or cancer. Haptoglobin level in milk has been used for the diagnosis of cow mastitis. In this study, anti-bovine haptoglobin antibody or bovine hemoglobin was chemically immobilized on the surface of the QCM, and the resulting sensor chips were tested for their response to samples containing haptoglobin at different concentrations. Concentration dependent frequency change was observed with both of the sensor chips. Especially, the sensor chip containing anti-bovine haptoglobin antibody showed sufficient sensitivity in the concentrations typically observed in the cows with mastitis.

Optimization of Quartz Crystal Microbalance-Precipitation Sensor Measuring Acetylcholinesterase Activity

  • Kim, Nam-Soo;Park, In-Seon;Kim, Dong-Kyung
    • Journal of Microbiology and Biotechnology
    • /
    • 제16권10호
    • /
    • pp.1523-1528
    • /
    • 2006
  • The optimization of a batch-type quartz crystal microbalance (QCM)-precipitation sensor measuring acetylcholinesterase (AChE) activity was conducted. To covalently bind AChE onto the gold electrode of a QCM surface, glutaraldehyde cross-linking to a cystamine self-assembled monolayer was tried at different cystamine concentrations. At the optimum conditions of the QCM-precipitation sensor, 0.1 M potassium phosphate buffer (pH 8.0), containing 0.01% Tween 80, was used as the reaction buffer, with the enzyme amount of 5 units for immobilization and the substrate concentration of 50 mg/ml. The current biosensor might find a future applicability to the sum parameter detection on organophosphorus and carbamate pesticides.

Piezoelectric immunosensor for the detection of Edwardsiellosis

  • Hong, Sung-Rok;Choi, Suk-Jung;Jeong, Hyun-Do;Hong, Su-Hee
    • 한국어병학회지
    • /
    • 제20권3호
    • /
    • pp.307-313
    • /
    • 2007
  • In this study, a QCM biosensor was made to detect Edwardsiella tarda (E. tarda) using a specific antibody. A 9 MHz AT-cut piezoelectric wafer layered with two gold electrodes of 5mm diameter had a reproducibility of 0.1 Hz in frequency response and was used as the transducer of the QCM biosensor. Self assembled layer (SAM) was conformed on a quartz crystal by treating with 3-mer-captopropionic acid (MPA) and activated with N-ethyl-N'-(3-dimethyl-aminopropyl) carbodiimide (EDC) and N-hydroxysuccinimide (NHS). The resulting NHS group was further converted to hydrazide by the reaction with hydrazine. Aldehyde group was introduced into the carbohydrate moiety of anti-E. tarda antibody by the reaction with periodic acid and was used to immobilise the antibody through the reaction with hydrazide group on the electrode surface. A baseline was established in the presence of phosphate-buffered saline (PBS) and a resonant frequency (F1) was measured. Sample was added to the sensor surface and second resonant frequency (F2) was measured after unbound substances were washed out with PBS several times. Finally, the frequency shift (ΔF) representing the mass change was calculated by subtracting F2 from F1. After adding the oxidized anti-E. tarda antibody to the electrode surface containing hydrazide group, frequency shift of 288.811.4 Hz (mean S.E) was observed, thus proving that considerable amount of antibody was immobilized. In the immunoassay test, the frequency shift of 1877.75 Hz, 580.67 Hz, 221.39 Hz, 7.671.83 Hz (mean S.E) were observed at doses of 1000, 500, 100, 50 g of bacterial cells, respectively. It was also demonstrated that the prepared sensor chip was stable enough to withstand repeated surface regeneration with 0.2 M Tris-glycine and 1 % DMSO, pH 2.3 more than ten times.

Development of a biosensor from aptamers for detection of the porcine reproductive and respiratory syndrome virus

  • Kuitio, Chakpetch;Rasri, Natchaya;Kiriwan, Duangnapa;Unajak, Sasimanas;Choowongkomon, Kiattawee
    • Journal of Veterinary Science
    • /
    • 제21권5호
    • /
    • pp.79.1-79.12
    • /
    • 2020
  • Background: Recently, the pork industry of Thailand faced an epidemic of highly virulent strains of porcine reproductive and respiratory syndrome virus (PRRSV), which spread throughout Southeast Asia, including the Lao People's Democratic Republic and Cambodia. Hence, the rapid and on-site screening of infected pigs on a farm is essential. Objectives: To develop the new aptamer as a biosensor for detection PRRSV which are rapid and on-site screening of infected pig. Methods: New aptamers against PRSSV were identified using the combined techniques of capillary electrophoresis, colorimetric assay by gold nanoparticles, and quartz crystal microbalance (QCM). Results: Thirty-six candidate aptamers of the PRRSV were identified from the systematic evolution of ligands by exponential enrichment (SELEX) by capillary electrophoresis. Only 8 out of 36 aptamers could bind to the PRSSV, as shown in a colorimetric assay. Of the 8 aptamers tested, only the 1F aptamer could bind specifically to the PRSSV when presented with the classical swine fever virus and a pseudo rabies virus. The QCM was used to confirm the specificity and sensitivity of the 1F aptamer with a detection limit of 1.87 × 1010 particles. Conclusions: SELEX screening of the aptamer equipped with capillary electrophoresis potentially revealed promising candidates for detecting the PRRSV. The 1F aptamer exhibited the highest specificity and selectivity against the PRRSV. These findings suggest that 1F is a promising aptamer for further developing a novel PRRSV rapid detection kit.

Electrochemical Detection of Self-Assembled Viologen Modified Electrode as Mediator of Glucose Sensor

  • Lee, Dong-Yun;Choi, Won-Suk;Park, Sang-Hyun;Kwon, Young-Soo
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권1호
    • /
    • pp.106-110
    • /
    • 2009
  • An amperometric glucose biosensor has been developed using viologen derivatives as a charge transfer mediator between a glucose oxidase (GOD) and a gold electrode. A highly stable self-assembled monolayer (SAM) of thiol-based viologen was immobilized onto the gold electrode of a quartz crystal microbalance (QCM) and GOD was immobilized onto the viologen modified electrode. This biosensor response to glucose was evaluated amperometrically in the potential of -300mV. Upon immobilization of the glucose oxidase onto the viologen modified electrode, the biosensor showed rapid response towards glucose. Experimental conditions influencing the biosensor performance, such as pH potential, were optimized and assessed. This biosensor offered excellent electrochemical responses for glucose concentration below ${\mu}$ mol level with high sensitivity and selectivity and short response time. The levels of the RSDs (<5%) for the entire analyses reflected the highly reproducible sensor performance. A linear calibration range between the current and the glucose concentration was obtained up to $4.5{\times}10^{-4}M$. The detection limit was determined to be $3.0{\times}10^{-6}M$.

Chemisorption of Thiolated Listeria monocytogenes-specific DNA onto the Gold Surface of Piezoelectric Quartz Crystal

  • Ryu, Sung-Hoon;Jung, Sang-Mi;Kim, Namsoo;Kim, Woo-Yeon
    • Journal of Applied Biological Chemistry
    • /
    • 제44권4호
    • /
    • pp.163-166
    • /
    • 2001
  • Piezoelectric (PZ) crystal biosensor system was used to detect the DNA of food pathogenic Listeria monocytogenes. L. monocytogenes-specific DNA was multiplied via the polymerase chain reaction using LM1 oligonucleotide (5'-TTACGAATTAAAAAGGAGCG-3') and LM2 oligonucleotide (5'-TTAAATCAGCAGGGGTCTTT-3') as primers. DNA fragment of 161 bp, which was specific only for L. monocytogenes, was observed. To obtain a large amount of single-stranded DNA containing an SH group used for coupling to the gold electrode chemisorptively, LM1 oligonucleotide containing a mercaptohexyl group was utilized as a single strand PCR primer. The PCR product was immobilized onto the gold electrode of PZ crystal, and hybridization was monitored in quartz crystal microbalance (QCM) system by injecting the antisense single-stranded DNA of 161 nucleotides obtained via the single strand PCR using the unmodified LM2 primer. Approximately 70 Hz of frequency drop was observed in the QCM system in the case of two consecutive injections of $5{\mu}g$ of the antisense single-stranded DNA.

  • PDF

Development of Olfactory Biosensor Using Olfactory Receptor Proteins Expressed in E. coli

  • 성종환;고휘진;박태현
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2003년도 생물공학의 동향(XII)
    • /
    • pp.639-642
    • /
    • 2003
  • 본 연구는 후각 수용 단백질인 ODR10를 GST와 Histidine tag를 각각 N 말단과 C 말단에 삽입한 후 두 가지의 발현 벡터에 넣어 대장균에서 발현시켰다. 부분 정제된 단백질을 QCM의 수정진동자에 코팅한 후 여러 종류의 냄새 분자와의 상호 작용을 관찰하였다. 발현양은 적었지만 QCM실험 결과 발현된 단백질이 diacetyl과 반응한다는 것을 알 수 있었다. ODR10 단백질과 diacetyl의 결합 정도는 다른 냄새 분자와 비교했을 때 $5{\sim}10$배 정도 차이가 났으며 이를 통해 후각 수용 단백질을 발현시킨 대장균 세포들을 후각센서를 개발하는데 사용할 수 있다는 것을 알 수 있었다. 또한 현재까지는 1000가지 이상 존재한다고 알려진 후각 수용 단백질들이 어떤 냄새 분자와 특이적인 결합성을 가지는지 조사하기 위해서는 복잡하고 시간이 오래 걸리는 실험을 해야 했었지만, 대장균에서 발현시키는 시스템을 통해 경제적이고 효율적으로 조사를 할 수 있게 되었다.

  • PDF

Development of piezoelectric immunosensor for the rapid detection of marine derived pathogenic bacteria, Vibrio vulnificus

  • Hong, Suhee;Jeong, Hyun-Do
    • 한국어병학회지
    • /
    • 제27권2호
    • /
    • pp.99-105
    • /
    • 2014
  • Biosensors consist of biochemical recognition agents like antibodies immobilized on the surfaces of transducers that change the recognition into a measurable electronic signal. Here we report a piezoelectric immunosensor made to detect Vibrio vulnificus. A 9MHz AT-cut piezoelectric wafer attached with two gold electrodes of 5mm diameter was used as the transducer of the QCM biosensor with a reproducibility of ${\pm}0.1Hz$ in frequency response. We have tried different approaches to immobilize antibody on the sensor chip. Concerning the orientation of antibody for the best antigen binding capacity, the antibody was immobilized by specific binding to protein G or by cross-linking through hydrazine. In addition, protein G was cross-linked on glutaraldehyde activated immine layer (PEI) or EDC/NHS activated sulfide monolayer (MPA). PEI was found to be more effective to immobilize protein G following glutaraldehyde activation than MPA. However, hydrazine chip showed a better capability to immobilize more IgG than protein G chip and a higher sensitivity. The sensor system was able to detect V. vulnificus in dose dependent manner and was able to detect bacterial cells within 5 minutes by monitoring frequency shifts in real time. The detection limit can be improved by preincubation to enrich the bacterial cell number.