• 제목/요약/키워드: QCM

검색결과 139건 처리시간 0.026초

PVC 및 GC물질의 혼합액을 코팅한 QCM가스센서의 센싱 및 열화특성 (Sensing and Degradation Properties in the QCM Gas Sensor Coated with the PVC and GC Blended Liquid)

  • 장경욱;김명호;이준웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.483-486
    • /
    • 2000
  • In the recognition of the gases using the quartz crystal rnicrobalance (QCM) coated with the film materials, it is important to obtain the recognition ability of gases, and the stability of film coated above the QCM. Especially, the thickness of film coated above the QCM is decreased according with the using circumstance and time of QCM gas sensor. Therefore, the sensing chararcteristics of film is changed with these. In this paper, we coated the lipid GC materials varing with the blended amount of PVC(Po1y Vinyl Chloride) and solution (Tetra Hydrofan:THF) above QCM to obtain the stability of lipid PC film. QCM gas sensors coated with film materials were measured the frequency change in the chamber of stationary gas sensing system injected 1-hexane, ethyl acetate, ethanol and benzene of 20.4 respectively. Also, we measured the degradation characteristics of QCM gas sensor to show the properties of stability.

  • PDF

PVC 및 PC 혼합액을 코팅한 QCM 가스센서의 센싱 및 열화 특성 (Sensing and Degradation Characteristics in the QCM Gas Sensor Coated with the PVC and PC)

  • 장경욱;김명호;이준웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 전자세라믹스 센서 및 박막재료 반도체재료 일렉트렛트 및 응용기술
    • /
    • pp.176-179
    • /
    • 2000
  • In the recognition of the gases using the quartz crystal microbalance (QCM) coated with the film materials, it is important to obtain the recognition ability of gases, and the stability of film coated above the QCM. Especially, the thickness of film coated above the QCM is decreased according with the using circumstance and time of QCM gas sensor. Therefore, the sensing chararcteristics of film is changed with these. In this paper, we coated the lipid PC (Phosphatidyl Choline) materials varing with the blended amount of PVC(Poly Vinyl Chloride) and solution (Tetra Hydrofan:THF) above QCM to obtain the stability of lipid PC film. QCM gas sensors coated with film materials were measured the frequency change in the chamber of stationary gas sensing system injected 1-hexane, ethyl acetate, ethanol and benzene of $20{\mu}{\ell}$, respectively. We obtained the principal component analysis (PCA) from the frequency change due to the absorption of gas. Also, we measured the degradation characteristics of QCM gas sensor to show the properties of stability.

  • PDF

PEG 물질을 도포한 QCM 가스센서의 열화특성 (Degradation Properties in the QCM Gas Sensors Coated with the PEG Materials)

  • 장경욱;김명호;이원재;김상걸;정동회;이준웅;이호식;김태완
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.218-222
    • /
    • 2002
  • In the recognition of the gases using the quartz crystal microbalance (QCM) coated with the PEG film materials, it is important to obtain the recognition ability of gases, and the stability of PEG film coated above the QCM. Especially, the thickness of PEG film coated above the QCM is decreased according with the using circumstance and time of QCM gas sensor. Therefore, the sensing characteristics of PEG film is changed with these. In this paper, we coated the PEG materials varing with the blended amount of PVC(Poly Vinyl Chloride) and chloroform above QCM to obtain the sensitive and the stability of PEG film. We measured the degradation characteristics of QCM gas sensor in the ethyle acetate 50[%] concentration to show the properties of stability.

  • PDF

동시 증발 증착법을 이용한 SmBCO 초전도층 증착에서 조성비 제어 방법에 관한 연구 (Study on the control methods of compositional ratios in co-evaporation system for SmBCO coated conductor)

  • 김호섭;하홍수;오상수;고락길;송규정;하동우;김태형;염도준;이남진;문승현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.294-294
    • /
    • 2008
  • 동시 증발 증착법 화합물의 구성원자를 독립적으로 증발시켜서 기판에 증착하는 방법이다. 각 물질은 온도에 따른 증기압을 가지는데 각 물질의 온도를 조절하여 증착률을 조절한다. 보트에서 떠난 원자가 기판에 도달할 확률은 챔버의 진공도, 보토와 기판과의 거리 등에 의하여 영향을 받는다. 진공도가 나쁠수록, 보트와 기판과의 거리가 멀수록 기판에 도달할 확률이 떨어진다. 동시증발 증착법을 이용한 SmBCO 초전도층 증착에서 각 물질의 기판에 도달하는 원자비를 조절하기 위하여 QCM(증착률 측정장치), QCM 가이드를 사용하였다. QCM sensor 입구에 튜브형태의 QCM 가이드를 설치하고 QCM 가이드가 특정한 물질의 증발보트를 향하도록 배치하였다. 따라서 각 보트에서 떠난 원자들은 특정한 QCM sensor에 도달하게 되고 결국 3원소(Sm, Ba, Cu)의 증착률의 비를 조절함으로써 조성비를 조절할 수 있게 된다. QCM 증착률의 비와 실제 조성비는 여러 가지 변수에 의하여 영향을 받는 다. 대표적인 변수는 챔버의 진공도, QCM 가이드의 직경 및 길이, QCM 센서와 보트와의 거리 등이 있다. 진공도가 높을수록 특정 보트에서 떠난 원자들이 QCM 가이드 입구에 도달할 확률이 낮아지고, QCM 가이드의 직경이 좁을수록 가이드 내벽에 흡착될 확률이 높아진다. 또한 QCM센서와 보트와의 거리가 멀수록 챔버내 잔류가스의 원자들과 충돌확률이 높아지므로 도달확률이 줄어들게 된다. 동시 증발 증확법에서 조성비의 재현성을 높이기 위해서는 매회 증착실험에서 진공도가 일정해야 하며, QCM 가이드와 보트와의 거리를 되도록 최소화 하고, QCM 직경을 크게 하는 것이 유리하다.

  • PDF

압전 수정 결정 미량 천평[PZ QCM] 바이오센서의 원리와 응용 (The Theory and Application or Piezoelectric Quartz Crystal Microbalance[PZ QCM] for Biosensor)

  • 김의락
    • KSBB Journal
    • /
    • 제18권2호
    • /
    • pp.79-89
    • /
    • 2003
  • This article contains an overview of acoustic wave devices, the theory and application of piezoelectric quartz crystal microbalances(PZ QCM), clinical analysis, gas phase detection, DNA biosensors, drug analysis, food microbial analysis and environmental analysis.

기상확산 자기조립화법에 QCM수식과 Madelic Acid 키랄물질 측정 (Quartz Crystal Microbalance Modified by a Novel Vapor Diffused Molecular Assembly Technique and Measurement of Chiral Mandelic Acid)

  • 김종민;김승진;우선영;장석희;김우식;장상목
    • Korean Chemical Engineering Research
    • /
    • 제48권5호
    • /
    • pp.574-582
    • /
    • 2010
  • 본 연구는 기상확산 자기조립화기법으로 수정진동자 표면을 L-Penicillamine와 D-Penicillamine으로 수식하여 대표적인 키랄물질인 R-(-)-Mandelic acid와 S-(+)-Mandelic acid에 대한 키랄물질 인식과 측정 가능성을 검토한 것이다. 수정진동자의 전극 표면에 3차원 입체구조가 다른 Penicillamine의 이성질체를 기상확산법으로 수식한 결과를 QCM과 AFM을 이용하여 관찰하여, 수정진동자 표면위의 분자구조의 형성에서 상이한 구조를 가지게 된다는 것을 확인하였다. L, D-Penicillamine이 수식된 수정진동자를 이용하여 R-(-)-Mandelic acid와 S-(+)- Mandelic acid에 대한 감응성을 검토한 결과, L-Penicillamine이 수식된 수정진동자는 R-(-)-Mandelic acid와 S-(+)- Mandelic acid에 대하여 선택적 감응성이 없었으나 D-Penicillamine이 수식된 수정진동자는 R-(-)-Mandelic acid에 대하여 선택적 감응성을 나타냄을 알 수 있었다. 본 연구결과, 기상확산법을 이용하여 다양한 선택성 막의 배열이 가능함을 알 수 있었고, 이렇게 배열된 박막으로 수식된 QCM을 이용하여 Mandelic Acid 이성질체 혼합물에서 특정 광학 이성질체의 검출이 가능함을 확인할 수 있었다.

메칠멜캅탄 가스센서용 TiO2/전해질폴리머 박막 제조 (Fabrication of TiO2/polyelectrolyte thin film for a methyl mercaptan gas sensor)

  • 김진호;황종희;이미재;김세기;임태영
    • 한국결정성장학회지
    • /
    • 제20권5호
    • /
    • pp.221-226
    • /
    • 2010
  • 메칠멜캅탄($CH_3SH$) 가스를 검출하는 수정진동자(QCM) 가스센서를 QCM의 전극에 $TiO_2$ 나노입자와 전해질 폴리머를 증착하여 제조하였다. LBL-SA법에 의해 제조된 $TiO_2$/PSS 박막은 높은 비표면적을 나타내었고, 가스센서의 감도를 증가시켰다. 1.0 ppm의 농도를 갖는 메칠멜캅탄에 노출된 TEA 혹은 $TiO_2$/PSS 막이 증착된 QCM의 주파수 변이는 각각 약 9 Hz, 2 Hz 였다. ($TiO_2$/PSS) 박막의 증착수가 늘어남에 따라 제조된 박막의 비표면적이 증가하게 되어 QCM 센서의 주파수 변이도 점차적으로 증가하였다. 추가적으로 메칠멜캅탄 가스의 농도가 0.5 ppm에서 2.0 ppm으로 높아짐에 따라 QCM 센서의 주파수 변화도 증가되었다. 본 연구에서는, ($TiO_2$/PSS) 박막이 증착된 QCM 센서의 표면구조의 변화와 센서 특성을 측정하였다.

고분자 필름이 코팅된 QCM 시스템에 의한 방향족 화합물의 흡착 (Adsorption of Aromatic Compounds on a QCM System Coated with Polymer Films)

  • 황민진;심왕근;문희
    • Korean Chemical Engineering Research
    • /
    • 제51권2호
    • /
    • pp.233-239
    • /
    • 2013
  • Poly(isobutylene), polystyrene 및 poly(methyl methacrylate)로 코팅된 quartz crystal microbalance(QCM) 시스템을 구성하여, 매우 낮은 압력에서 benzene, toluene, p-xylene의 흡착량을 측정하였다. 모든 흡착실험에서 QCM 시스템의 공진 주파수 변화는 압력의 증가에 비례하였다. 실험결과로부터 각각의 고분자 필름에 대한 흡착물질의 Henry 상수를 구하였으며 고분자 필름과 흡착물질 사이의 최소 흡착 포텐셜 에너지와 비교하였다. 전체적으로 흡착량과 최소 흡착 포텐셜 에너지는 명백한 상관관계가 있었다.

지질과 PVC의 혼합액을 감응막으로 도포한 수정진동자 가스센서의 센싱 및 열화특성 (Sensing and Degradation Properties in the Quartz Crystal Microbalance Coated with the PVC and the Lipid Blended Materials)

  • 장경욱;김명호;최명규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.44-47
    • /
    • 2000
  • In the recognition of the gases using the quartz crystal microbalance (QCM) coated with the film materials, it is important to obtain the recognition ability of gases, and the stability of film coated above the QCM. Especially, the thickness of film coated above the QCM is decreased according with the using circumstance and time of QCM gas sensor. Therefore, the sensing characteristics of film is changed with these. In this paper, we coated the lipid PC (Phosphatidyl Choline) materials varing with the blended amount of PVC(Poly Vinyl Chloride) and solution (Tetra Hydrofan:THF) above QCM to obtain the sensitive and the stability of lipid PC film. QCM gas sensors coated with film materials were measured the frequency change in the chamber of stationary gas sensing system injected 1-hexane, ethyl acetate, ethanol and benzene of $20{\mu}{\ell}$, respectively. We also measured the degradation characteristics of QCM gas sensor to show the properties of stability.

  • PDF

배터리 교체형 전기자동차의 배터리 위치좌표 획득을 위한 영상처리기술 검증 (Replaceable battery electric car's battery location coordinates image processing techniques for obtaining verification)

  • 김응필;정원재;김정윤;박준석;김태희
    • 정보통신설비학회논문지
    • /
    • 제11권2호
    • /
    • pp.52-57
    • /
    • 2012
  • In this paper describe configuration about QCM system for image processing device. It presents that QCM's image processing board video from the camera recognized by the PLC's battery removable exact location coordinates to the robot image processing technology to deliver. In addition, QCM video image processing technology for improved data reliability is described. In this paper define the landmarks of battery for obtaining the location coordinates and verify battery the location coordinates acquisition process from field tests of the QCM/QTPE-BUS Battery Exchange System.

  • PDF