Quantitative Analysis of Effects for Quality Control on Medical Primary Class LCD Display Devices Based on AAPM TG18 Report (AAPM TG18에 의한 진단용 LCD 디스플레이 장치 정도관리 효과의 정량적 분석)

  • Jung Hai-Jo;Kim Hee-Joung
    • Progress in Medical Physics
    • /
    • v.17 no.2
    • /
    • pp.77-82
    • /
    • 2006
  • The image display is an Important component of PACS and of medical digital imaging chain. Displayed image qualify is affected by the physical characteristics of display device, appropriate clinical settings and calibrations, and ambient lighting conditions. The performance of display systems is continuously degraded over time due to luminance deterioration and changes of clinical setting parameters. A routine QC is recommended because the performance of display systems is continuously degraded over time. Ten flat panel monochrome LCD display devices were included in the evaluation of the QC effect. The effect of QC on primary class LCD medical display devices for selected QC tests was evaluated by comparing the performances, luminance response, luminance dependencies, display resolution and display chromaticity in this study, of before and after the calibration procedures. The effects of the QC are significant to luminance response and luminance spatial dependencies test and the other side, are slight to the display resolution and display chromaticity test. A routine QC of display device is essential for the consistency of medical image display and presentation. The study of the QC effects of display devices will play an important role in practical QC procedures of display devices.

  • PDF

Genetic Studies of Redcell Types for Individual Identification and Parentage Verification in Horse Breeds. (개체식별 및 친자판정을 위한 말의 적혈구항원형에 관한 연구)

  • 조길재;조병욱
    • Journal of Life Science
    • /
    • v.14 no.4
    • /
    • pp.696-701
    • /
    • 2004
  • The present study was carried out to investigate the redcell types of horse breeds. A total of 210 horses (73 Korean native horses, 118 crossbreed horses, and 19 Mongolian horses) were tested a redcell types by serological procedure, and their phenotypes and gene frequencies were estimated. The blood groups phenotypes observed with highest frequency were Aa (27.4%, 63.6%, 63.2%), Ca (97.3%, 94.9%, 89.5%), K- (97.3%, 99.2%, 84.2%), Pa (39.7%, 44.9%, 42.1%), and Ua (71.2%, 70.3%, 63.2%) in the Korean native horse, crossbreed horse, and Mongolian horse, respectively. In the D system and Q system, phenotypes observed with highest frequency were Dbcm/dghm (12.3%), Dbcm/cgm (14.4%), Dcgm/dghm (15.8%), and Qc (56.2%), Qabc (36.4%), Qc (31.6%) in the Korean native horse, crossbreed horse, and Mongolian horse, respectively Alleles observed with highest frequency were A- (0.287), Ca(0.827), Ddghm (0.226), K- (0.985), Pa (0.358), Qc (0.494), U-(0.529) in the Korean native horse, Aa (0.529), Ca (0.776), Dbcm (0.306), K- (0.995), P- (0.531), Q- (0.504), U- (0.548) in crossbreed horse, and Aa (0.421), Ca (0.895), Ddghm (0.421), K- (0.842), Pa (0.447), Qc (0.448), Ua (0.632) in Mongolian horse. Dcfgk and D- alleles were not detected in these horses. These results present basic information for estimating the genetic relationships between the Korean native horse, and developing a system for parentage verification and individual identification in these horses.

The Development of Quality Assurance Program for CyberKnife (사이버나이프의 품질관리 절차서 개발)

  • Jang, Ji-Sun;Kang, Young-Nam;Shin, Dong-Oh;Kim, Moon-Chan;Yoon, Sei-Chul;Choi, Ihl-Bohng;Kim, Mi-Sook;Cho, Chul-Koo;Yoo, Seong-Yul;Kwon, Soo-Il;Lee, Dong-Han
    • Radiation Oncology Journal
    • /
    • v.24 no.3
    • /
    • pp.185-191
    • /
    • 2006
  • [ $\underline{Purpose}$ ]: Standardization quality assurance (QA) program of CyberKnife for suitable circumstances in Korea has not been established. In this research, we investigated the development of QA program for CyberKnife and evaluation of the feasibility under applications. $\underline{Materials\;and\;Methods}$: Considering the feature of constitution for systems and the therapeutic methodology of CyberKnife, the list of quality control (QC) was established and divided dependent on the each period of operations. And then all these developed QC lists were categorized into three groups such as basic QC, delivery specific QC, and patient specific QC based on the each purpose of QA. In order to verify the validity of the established QA program, this QC lists was applied to two CyberKnife centers. The acceptable tolerance was based on the undertaking inspection list from the CyberKnife manufacturer and the QC results during last three years of two CyberKnife centers in Korea. The acquired measurement results were evaluated for the analysis of the current QA status and the verification of the propriety for the developed QA program. $\underline{Results}$: The current QA status of two CyberKnife centers was evaluated from the accuracy of all measurements in relation with application of the established QA program. Each measurement result was verified having a good agreement within the acceptable tolerance limit of the developed QA program. $\underline{Conclusion}$: It is considered that the developed QA program in this research could be established the standardization of QC methods for CyberKnife and confirmed the accuracy and stability for the image-guided stereotactic radiotherapy.

A STUDY ON THE PHYSICAL PROPERTIES AND VOLUMETRIC STABILITY OF SR-IVOCAP RESIN SYSTEM (SR-Ivocap resin system의 물리적 특성과 체적 안정성에 관한 연구)

  • Eun, Sung-Sik;Kweon, Hyeog-Sin;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.3
    • /
    • pp.453-467
    • /
    • 1998
  • This study helps to clarify conflicting reports by comparing the physical properties and accuracy of complete denture processed by the pack and press technique, continuous- pressure injection technique(SR-Ivocap system) and Mark press technique. The 6 different specimens have been evaluated using the SEM, Impact test, DSC (Differential Scanning Calorimetry) and DMTA (Dynamic Mechanical Thermal Analysis). Each sample was made of SR-Ivocap resin and QC-20 resin by different processing methods. The results were as follows ; 1. As the result of the observation on the fracture surface of resin by use of SEM, sample SR-Ivocap resin cured by continuous pressure injection method showed the most homogeneous structure. This is why molecules in SR-Ivocap resin have no orientation. 2. As the result of the Impact test in order to measure the deformity, fracture energy and impact resistance of resin, the samples with QC-20 acrylic resin and SR-Ivocap resin cured by continuous pressure injection method were exellent. 3. In consequence of measuring ${\alpha}$-glass transition temperature by use of DSC on the basis of temperature change, the glass transition temperatures of sample QC-20 resin cured by pack and press method and sample SR-Ivocap resin cured by continuous pressure injection method were very similar. Thus volumetric stability could not be evaluated only by glass transition temperature. 4. In comparing volumetric stability data by DMTA, the glass transition temperature(Tg) showed $137.88^{\circ}C$ at sample QC-20 resin cured by pack and press method and $139.78^{\circ}C$ at sample SR-Ivocap resin cured by continuous pressure injection method. Therefore sample SR-Ivocap resin cured by continuous pressure injection method seems to be superior to sample QC-20 resin cured by pack and press method in the dimensional stability at high temperature. 5. In comparing storage modulus data by DMTA, the storage modulus of sample SR-Ivocap resin cured by continuous pressure injection method was higher than that of sample QC-20 resin cured by pack and press method. So. sample SR-Ivocap resin cured by continuous pressure injection method seems to be superior to sample QC-20 resin cured by pack and press method in impact strength.

  • PDF

The Experimental Study on Hydration Properties of Quaternary Component Blended High Fluidity Concrete with CO2 Reduction (탄소저감형 4성분계 고유동 콘크리트의 수화 특성에 관한 연구)

  • Choi, Yun-Wang;Oh, Sung-Rok;Jo, Jun-Hee;Kang, Hyun-Jin
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.4
    • /
    • pp.403-413
    • /
    • 2017
  • In this paper, to increase the use of industrial byproducts for $CO_2$ reduction and to improve construction performance, it was manufactured that $CO_2$ reduction type quaternary component high fluidity concrete (QC-HFC) with Reduced cement usage by more than 80% and its quality and hydration characteristics were evaluated. QC-HFC was found to satisfy the target performance, and the flow and mechanical properties were similar to those of conventional concrete. The drying shrinkage of QC-HFC decreased about twice compared with the conventional blend, and the hydration heat decreased about 36%. As a result, it can be concluded that the amount of cracks can be reduced by reducing temperature stress due to hydration heat reduction effect and reducing deformation due to relatively small temperature difference between inside and outside. Also, As a result of the simulation of the mass structure, the temperature cracking index of QC-HFC is 1.1 or more, and the cracking probability is reduced by about 35%, so that the crack due to temperature can be reduced.

The Effect of Reinforcing Materials on the Transverse Strength of Denture Base Resin (의치상 레진 강화재가 의치상 굽힘강도에 미치는 영향)

  • Lee, Jun-Sik;Song, Young-Gyun;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.4
    • /
    • pp.327-337
    • /
    • 2012
  • The object of this study was to find out the effect of various reinforcing materials including Quarts Splint$^{TM}$ Mesh on the transverse strength of the denture resin. QC-20 and Lucitone199$^{(R)}$ were used as the denture resin, and polyethylene fiber Ribbond$^{(R)}$, light curing quarts fiber Quarts Splint$^{TM}$ Mesh, metal mesh were used as the reinforcing materials. Ten specimens were fabricated for each group and the size of specimens was $2.0{\times}10.0{\times}65.0mm$. To compare the effect of resin thickness, additional specimens of $2.5{\times}10.0{\times}65.0mm$, $3.0{\times}10.0{\times}65.0mm$ were fabricated. In the control group, the transverse strength of Lucitone199$^{(R)}$ was significantly higher than that of QC-20(p<0.05). Among the specimens of 2.0 mm thickness fabricated with $Lucitone199^{(R)}$ and QC-20, they showed high transverse strength in the order of metal mesh, Quarts Splint$^{TM}$ Mesh, Ribbond$^{(R)}$, and control group. In the specimens of 2.0 mm, 2.5 mm thickness, the transverse strength of Quarts Splint$^{TM}$ Mesh were significantly higher than that of QC-20(p<0.05). But in the specimens of 3.0 mm thickness, there was no significant difference.

A Study on the Effect of Customer-Oriented Quality Circle Activities on Business Performance for Service Firms (서비스 기업의 고객지향적 품질분임조 활동이 기업성과에 미치는 영향에 관한 연구)

  • Song, Gwangsuk
    • Journal of Korean Society for Quality Management
    • /
    • v.45 no.4
    • /
    • pp.903-916
    • /
    • 2017
  • Purpose: The paper analyzes empirically the causal relationship between customer-oriented Quality circle activities and Business Performance for Korean service firms. We compare the operational characteristic behavior of the service firms and business performance. Methods: In this study, we used 3 variables, QC activities, Employee commitment and business performance. Especially, Service SME's QC Circle activities were analyzed in related with growth of company on the basis activities such as Leadership(team), improvement activity, Organizational learning, customer-focus activity and employee suggestion. Results: The result of analysis showed that employee commitment affected significantly on financial performance and non-financial performance and in turn, improvement activities, Organizational learning and customer-focus activity affected significantly on business performance (financial and non-financial). Conclusion: In the summary of the characteristics of this study based on the research results, first, segmenting the QCC activities in the service business into 5 elements can be considered to be differentiated from the existing researches in the aspect of utilizing the organization's objective-oriented variables differently from the researches utilized the variables related personal characteristics. Second, this study suggested the recent research results that suggested the problems of the QCC clearly, through which what new QC story approach was suggested has working level value in the aspect of activating the service QCC.

Quality Control of Diagnostic X-ray Units for Animal Hospital (동물병원의 방사선발생장치 정도관리에 대한 연구)

  • Kim, Sang-Woo;Lee, Ji-Hoon;Park, Yei-Seul;Rhim, Jea-Dong;Seoung, Youl-Hun
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2010.04a
    • /
    • pp.231-237
    • /
    • 2010
  • The purpose of this study was to investigate the actual conditions of radiation safety supervision in animal clinics using quality assurance (QA) and quality control (QC) of diagnostic X-ray units. The surveys for QA/QC, equipment condition, and safety supervision were carried out in 18 animal clinics randomly. The QA/QC included reproducibility of dose exposure, kVp, mAs, collimator accuracy test, collimator luminance test, X-ray view box luminance test, grounding system equipment test and external leakage current test. As a result, 44.44% of reproducibility of dose exposure was proper, 81. 25% of kVp test was good, and 100% of mAs test was appropriate. Also, 66.66% of collimator accuracy test was proper, 61.11% of collimator luminance test was good, 53.13% of X-ray view box luminance test was suitable. In addition, only 5.55% of grounding system equipment and ground resistance was proper, 63.64% of external leakage current test was appropriate in grounding system equipment test.

  • PDF

Yield, Nutritional Content, and Antioxidant Activity of Pleurotus ostreatus on Corncobs Supplemented with Herb Residues

  • Jin, Zhiqiang;Li, Yunling;Ren, Jiahong;Qin, Nan
    • Mycobiology
    • /
    • v.46 no.1
    • /
    • pp.24-32
    • /
    • 2018
  • Improper disposal of herb residues in China has caused severe problems to the surrounding environment and human safety. Three herb residues, i.e., compound Kushen injection residues (CKI) and part one and part two of Qizhitongluo Capsule residues (QC1 and QC2, respectively), were used for the cultivation of Pleurotus ostreatus. The effect of the supplementation of corncobs (CC) with different herb residues on yield, nutritional composition, and antioxidant activity of P. ostreatus was investigated. Compared to the control, the higher mycelial growth rate was observed on substrates CC +30% CKI and CC +30% QC1, while the higher yield was obtained from substrates CC +30% QC2 and CC +30% CKI. Moreover, chemical analysis of fruit bodies revealed that the addition of herb residues to CC significantly increased proteins, amino acids, ashes, minerals (Na and Ca), and total phenolic contents but significantly reduced carbohydrates and $IC_{50}$ values of DPPH radicals. In addition, no heavy metals (Pb, Cd, and As) were detected in the fruiting bodies harvested from different substrate combinations. These results demonstrated that mixtures of CC with herb residues might be utilized as a novel, practical, and easily available substrate for the cultivation of P. ostreatus, which is beneficial for the effective management of herb residues.

A Study on Quality Improvement of Medical Equipments (의료기기 QI 활동 개선방안에 대한 연구)

  • Kang, Hun-Hee;Juh, Ra-Hyeong;Kim, Jong-Soon;Kim, Seo-Hwak;Huh, Soo-Jin
    • Quality Improvement in Health Care
    • /
    • v.5 no.2
    • /
    • pp.190-201
    • /
    • 1998
  • Background : Medical equipments take a very important role in diagnosis and treatment of disease in modern medicine and effective maintenance of the equipments is a necessary to provide a good health care to the public. After developing a new QC program for effective maintenance of medical equipments and practicing it for a year, we report the results of the new program. Methods : The maintenance data of 9 equipments in 8 categories including a CT Scanner were analyzed with regard to the parts responsible for most frequent failure and cause of the failure. After learning the most frequent failure part and cause of the failure, we developed a new QC program that emphasizes preventive maintenance of the most frequent failure part. We compared the number of failure per year and active rate of each equipment before and after the adoption of the new QC program. Results : The average number of failure per year per equipment was 20.7 before and it decreased by 43% to 11.9 after adoption of the new QC program. The average active rate of the equipments was 92.6% before and it increased by 3.2% to 95.8% after adoption of the new program. Conclusions : The practice of the new QC program appears very useful as it decreased the failure rate and increased the active rate of the equipments.

  • PDF