• Title/Summary/Keyword: Q-Tool

Search Result 245, Processing Time 0.036 seconds

HI gas kinematics of paired galaxies in the cluster environment from ASKAP pilot observations

  • Kim, Shin-Jeong;Oh, Se-Heon;Kim, Minsu;Park, Hye-Jin;Kim, Shinna
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.2
    • /
    • pp.70.1-70.1
    • /
    • 2021
  • We examine the HI gas kinematics and distributions of galaxy pairs in group or cluster environments from high-resolution Australian Square Kilometer Array Pathfinder (ASKAP) WALLABY pilot observations. We use 32 well-resolved close pair galaxies from the Hydra, Norma, and NGC 4636, two clusters and a group of which are identified by their spectroscopy information and additional visual inspection. We perform profile decomposition of HI velocity profiles of the galaxies using a new tool, BAYGAUD which allows us to separate a line-of-sight velocity profile into an optimal number of Gaussian components based on Bayesian MCMC techniques. Then, we construct super profiles via stacking of individual HI velocity profiles after aligning their central velocities. We fit a model which consists of double Gaussian components to the super profiles, and classify them as kinematically cold and warm HI gas components with respect to their velocity dispersions, narrower or wider 𝜎, respectively. The kinematically cold HI gas reservoir (M_cold/M_HI) of the paired galaxies is found to be relatively higher than that of unpaired control samples in the clusters and the group, showing a positive correlation with the HI mass in general. Additionally, we quantify the gravitational instability of the HI gas disk of the sample galaxies using their Toomre Q parameters and HI morphological disturbances. While no significant difference is found for the Q parameter values between the paired and unpaired galaxies, the paired galaxies tend to have larger HI asymmetry values which are derived using their moment0 map compared to those of the non-paired control sample galaxies in the distribution.

  • PDF

Evaluation of applicability of linkage modelling using PHABSIM and SWAT (PHABSIM과 SWAT을 이용한 연계모델링 적용성 평가)

  • Kim, Yongwon;Woo, Soyoung;Kim, Sehoon;Son, Moobeen;Kim, Seongjoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.51-51
    • /
    • 2021
  • 환경생태유량은 수생태 건강성 유지를 위한 최소한의 유량으로 K-water에서는 유량증분방법론 기반의 1차원 물리적 서식처 모형인 PHABSIM(Physical habitat simulation system)을 이용해 고시지점에 대해 환경생태유량을 산정하여 제시하고 있으나, PHABSIM을 이용하여 환경생태유량을 산정하기 위해서는 지형, 수문 및 어류조사와 같은 현장조사를 지속적으로 실시해야한다는 한계점이 존재한다. 따라서 본 연구에서는 안동댐 하류유역(4,565.7 km2)을 대상으로 SWAT(Soil and water assessment tool)과 PHABSIM을 연계하여 수문모형을 이용한 유량 모의에 따른 대상 어종의 환경생태유량을 산정하고자 한다. SWAT 구축을 위해 DEM과 토양도 및 토지이용자료와 유역 내 위치한 7개의 기상관측소에 대한 40년(1980~2019)의 기상자료를 수집하여 적용하였으며, SWAT의 검보정을 위해 유역내 위치한 2개의 다목적 댐(안동댐, 임하댐)의 실측 운영자료와 1개의 수위관측소의 유량자료를 수집하였다. PHABSIM의 경우, 안동댐 하류유역에 대한 하천정비기본계획 보고서에 기반하여 지형자료를 입력하였으며 문헌조사를 통해 대상어종의 서식적합도지수를 수집하여 적용하였다. 3개 지점에 대한 SWAT 검보정결과, 평균 R2, NSE 및 RMSE는 각각 0.51~0.76, 0.47~0.74, 0.61~1.84 mm/day로 나타났다. PHABSIM과의 연계를 위해 검보정된 SWAT의 하천유량에 대해 유황분석을 실시하였고, 산정한 Q10과 Q355를 유량의 최대·최소 범위로 설정하여 PHABSIM의 유량 경계조건으로 활용하였다. 이를 이용하여 SWAT과 PHABSIM의 연계모델링 적용성을 평가하고 대상어종의 환경생태유량을 산정할 예정이다.

  • PDF

The Effectiveness of Spiral Computed Tomography as a Diagnostic Tool in Pulmonary Embolism(Comparison of Spiral CT with Ventilation-Perfusion Scan) (폐색전증 진단의 도구로서의 Spiral Computed Tomography의 유용성(폐환기관류주사와의 비교))

  • Koh, Jae-Hyun;Oh, Eun-Young;Park, Jung-Ho;Park, Sang-Joon;Yun, Jung-Hwan;Park, Jung-Woong;Suh, Gee-Young;Chung, Man-Pyo;Lee, Kyung-Soo;Kwon, O-Jung;Rhee, Chong-H.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.4
    • /
    • pp.564-573
    • /
    • 1999
  • Background: With variable symptoms and nonspecific radiographic appearances, pulmonary embolism (PE) is a frequent and often undiagnosed cause of mortality and morbidity. The Prospective Investigation of Pulmonary Embolism Diagnosis (PIOPED) study suggested that the majority of patients undergoing ventilation-perfusion (V-Q) scan would require additional studies to establish or to exclude the diagnosis of PE. Pulmonary angiography has been regarded as gold standard for diagnosis of PE. However, it is an invasive procedure that may be associated with significant notable morbidity and mortality. Thus, availability of an accurate, noninvasive screening examination is highly desirable. Method: From October 1994 to February 1997, twenty patients (male 13, female 7, range 23-91 years, median 58 years) who were suspected as pulmonary embolism on the basis of clinical evidence and underwent the spiral volumetric computed tomography (spiral CT), were studied retrospectively to evaluate the effectiveness of spiral CT as a diagnostic tool in PE. Results: PE could be excluded with spiral CT in 4 patients ; diagnoses of these patients were lung cancer, pneumonia with lung abscess, bilateral pleural effusion due to congestive heart failure, nonspecific pulmonary abnormality retrospectively. One patient who disclosed high probability in V/Q scan, could be diagnosed as pneumonia with lung abscess and underlying emphysema with spiral CT. Among 4 patients who showed intermediate and low probability in V/Q scan, 3 patients could be confirmed as PE with spiral CT. Spiral CT was helpful in 3 patients, in whom V/Q scan could not be performed due to other reasons (e.g. night time, mechanical ventilation) to confirm the diagnosis of PE. Spiral CT could demonstrate embolus above lobar artery level in 11 patients, and up to segmental artery level in 5 patients. Conclusion: This study demonstrated that spiral CT could allow accurate demonstration of thrombotic clots in centrally localized embolism. Spiral CT could be effective, specific, noninvasive and useful diagnostic screening modality for the diagnosis of pulmonary embolism.

  • PDF

A Development and Validation Study of the Web-based Korean Version of the Eating Disorder Diagnostic Scale DSM-5 (웹 기반 한국판 섭식장애진단척도 DSM-5의 개발 및 타당화 연구)

  • Lee, Hye Rin;Kwag, Kyung Hwa;Lee, You Kyung;Han, Soo Wan;Kim, Youl-Ri
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.28 no.2
    • /
    • pp.185-193
    • /
    • 2020
  • Objectives : The aim of this study was to develop and to verify the Korean version of the Eating Disorder Diagnosis Scale DSM-5 (K-EDDS) as a web-based diagnostic system, which enables rapid diagnosis of patients for early intervention. Methods : A total of 119 persons participated in the study, including patients with eating disorders (n=38) and college students (n=81). Along with the paper-and-pencil SCOFF, all participants completed the web-based K-EDDS, the Eating Disorder Examination-Questionaire (EDE-Q), and the Clinical Impairment Assessment Questionnaire (CIA). The semi-structured interview using the Eating Disorder Examination Interview (EDE) was conducted for participants with two or more SCOFF scores. Within two weeks, the web-based K-EDDS, the EDE-Q, and the CIA were re-tested. Results : In the exploratory factor analysis, four factors were extracted : body dissatisfaction, binge behaviors, binge frequency and compensatory behaviors. The four subscales of the web-based K-EDDS had significant correlation with each of the four subscales of the EDE-Q. The internal consistency of the web-based K-EDDS was highly satisfactory (Cronbach's alpha=0.93). The diagnostic agreement between the web-based K-EDDS and the EDE was excellent (96.83%), and the web-based K-EDDS's test-retest diagnostic agreement was fairly good (92.86%). The web-based K-EDDS and the CIA also showed significant differences between patients and general population, supporting discriminant validity. Conclusions : This study suggested that the web-based K-EDDS is a valid tool for assisting diagnosis of eating disorders based on DSM-5 in clinical and research fields.

A Study on QA for Radiation Therapy Machine by Using Implemented Electronic Portal Imaging Device (전자포탈영상장치의 제작과 방사선치료장치의 QA 적용에 관한 연구)

  • Lee, Dong-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.43 no.6 s.312
    • /
    • pp.68-75
    • /
    • 2006
  • During cancer therapy by using high energy radiation, it is possible to improve the radiation therapy efficiency by performing a precise radiation therapy after verification of generated setup errors. In this paper, the video based electronic portal imaging device (EPID) which could display the portal image with near real time was developed to verify treatment position errors in radiation therapy instead of an analog typed portal film. This EPID system for applying QA tool of radiation therapy machine was consisted of a metal/fluorescent screen, $45^{\circ}$mirror, camera and image grabber. Radiation field verification has been performed to check quality assurance of the treatment machine itself by using this EPID system. The radiation field error was easily observed by edge detection of irradiated field size on EPID image when $0.6^{\circ}$ shift of collimator angle was generated. So, this implemented EPID system could be used as a radiation QA tool.

Effectiveness Analysis and Profile Design Automation Tool Implementation for The Mass Production Weapon System Environmental Stress Screening Test (양산 무기체계 환경 부하 선별 시험 효과도 분석 및 프로파일 설계 자동화 도구 구현)

  • Kim, Jang-Eun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.8
    • /
    • pp.379-388
    • /
    • 2016
  • There are various system defects from weapons manufacturing due to the numerous production processes and various production environments. The first kind of defect is patent defects, which can be detected by visual inspection, functional testing, and existing quality control procedures during the manufacturing process. The second kind is latent defects, which cannot be detected though existing quality management approaches because of the complexity of the system and manufacturing process. To minimize the initial defect problems, environmental stress screening (ESS) is needed to detect the defects, remove them, and improve the product conditions based on the environmental stress conditions of temperature and vibration. We implemented a tool for quantitative ESS effectiveness analysis and profile design automation based on MIL-HDBK-344 and verified it using six scenarios with different temperature stress, vibration stress, and test designs.

Development of HRM Markers Based on Identification of SNPs from Next-Generation Sequencing of Sanguisorba officinalis, Sanguisorba tenuifolia f. alba (Trautv. & Mey.) Kitam and Sanguisorba tenuifolia Fisch. ex Link (오이풀, 흰오이풀, 긴오이풀의 NGS 기반 유전체 서열의 완전 해독 및 차세대 염기서열 재분석으로 탐색된 SNP 기반 HRM 분자표지 개발)

  • Sim, Mi-Ok;Jang, Ji Hun;Jung, Ho-Kyung;Hwang, Taeyeon;Kim, Sunyoung;Cho, Hyun-Woo
    • The Korea Journal of Herbology
    • /
    • v.34 no.6
    • /
    • pp.91-97
    • /
    • 2019
  • Objective : To establish a reliable tool between for the distinction of original plants of Sanguisorbae Radix, we analyzed the complete chloroplast genome sequence of Sanguisorbae Radix and identified single nucleotide polymorphisms (SNPs). Materials and methods : The chloroplast genome sequence of Sanguisorba officinalis, Sanguisorba tenuifolia f. alba (Trautv. & Mey.) Kitam and Sanguisorba tenuifolia Fisch. ex Link obtained using next-generation sequencing technology were described and compared with those of other species to develop specific markers. Candidate genetic markers were identified to distinguish species from the chloroplast sequences of each species using Modified Phred Phrap Consed and CLC Genomics Workbench programs. Results : The structure of the chloroplast genome of each sample that had been assembled and verified was circular, and the length was about 155 kbp. Through comparative analysis of the chloroplast sequences, we found 220 nucleotides, 158 SNPs, and 62 Indel (insertion and/or deletion), to distinguish Sanguisorba officinalis, Sanguisorba tenuifolia f. alba (Trautv. & Mey.) Kitam and Sanguisorba tenuifolia Fisch. ex Link. Finally, 15 specific SNP genetic markers were selected for the verification at positions. Avaliable primers for the dried herb, which is used as medicine, were used to develop the PCR amplification product of Sanguisorbae Radix to assess the applicability of PCR analysis. Conclusion : In this study, we found that Fendel-qPCR analysis based on the chloroplast DNA sequences can be an efficient tool for discrimination of Sanguisorba officinalis, Sanguisorba tenuifolia f. alba (Trautv. & Mey.) Kitam and Sanguisorba tenuifolia Fisch. ex Link.

Quantitative PCR for Etiologic Diagnosis of Methicillin-Resistant Staphylococcus aureus Pneumonia in Intensive Care Unit

  • Kwon, Sun-Jung;Jeon, Tae-Hyeon;Seo, Dong-Wook;Na, Moon-Joon;Choi, Eu-Gene;Son, Ji-Woong;Yoo, Eun-Hyung;Park, Chang-Gyo;Lee, Hoi-Young;Kim, Ju-Ock;Kim, Sun-Young;Kang, Jae-Ku
    • Tuberculosis and Respiratory Diseases
    • /
    • v.72 no.3
    • /
    • pp.293-301
    • /
    • 2012
  • Background: Ventilator-associated pneumonia (VAP) requires prompt and appropriate treatment. Since methicillin-resistant Staphylococcus aureus (MRSA) is a frequent pathogen in VAP, rapid identification of it, is pivotal. Our aim was to evaluate the utility of quantitative polymerase chain reaction (qPCR) as a useful method for etiologic diagnoses of MRSA pneumonia. Methods: We performed qPCR for mecA, S. aureus-specific femA-SA, and S. epidermidis-specific femA-SE genes from bronchoalveolar lavage or bronchial washing samples obtained from clinically-suspected VAP. Molecular identification of MRSA was based on the presence of the mecA and femA-SA gene, with the absence of the femA-SE gene. To compensate for the experimental and clinical conditions, we spiked an internal control in the course of DNA extraction. We estimated number of colony-forming units per mL (CFU/mL) of MRSA samples through a standard curve of a serially-diluted reference MRSA strain. We compared the threshold cycle (Ct) value with the microbiologic results of MRSA. Results: We obtained the mecA gene standard curve, which showed the detection limit of the mecA gene to be 100 fg, which corresponds to a copy number of 30. We chose cut-off Ct values of 27.94 (equivalent to $1{\times}10^4$ CFU/mL) and 21.78 (equivalent to $1{\times}10^5$ CFU/mL). The sensitivity and specificity of our assay were 88.9% and 88.9% respectively, when compared with quantitative cultures. Conclusion: Our results were valuable for diagnosing and identifying pathogens involved in VAP. We believe our modified qPCR is an appropriate tool for the rapid diagnosis of clinical pathogens regarding patients in the intensive care unit.

Robust Design for Showerhead Thermal Deformation

  • Gong, Dae-Wi;Kim, Ho-Jun;Lee, Seung-Mu;Won, Je-Hyeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.150.1-150.1
    • /
    • 2014
  • Showerhead is used as a main part in the semiconductor equipment. The face plate flatness should remain constant and the cleaning performance must be gained to keep the uniformity level of etching or deposition in chemical vapor deposition process. High operating temperature or long period of thermal loading could lead the showerhead to be deformed thermally. In some case, the thermal deformation appears very sensitive to showerhead performance. This paper describes the methods for robust design using computational fluid dynamics. To reveal the influence of the post distribution on flow pattern in the showerhead cavity, numerical simulation was performed for several post distributions. The flow structure appears similar to an impinging flow near a centered baffle in showerhead cavity. We took the structure as an index to estimate diffusion path. A robust design to reduce the thermal deformation of showerhead can be achieved using post number increase without ill effect on flow. To prevent the showerhead deformation by heat loading, its face plate thickness was determined additionally using numerical simulation. The face plate has thousands of impinging holes. The design key is to keep pressure drop distribution on the showerhead face plate with the holes. This study reads the methodology to apply to a showerhead hole design. A Hagen-Poiseuille equation gives the pressure drop in a fluid flowing through such hole. The assumptions of the equation are the fluid is viscous-incompressible and the flow is laminar fully developed in a through hole. An equation can be expressed with radius R and length L related to the volume flow rate Q from the Hagen-Poiseuille equation, $Q={\pi}R4{\Delta}p/8{\mu}L$, where ${\mu}$ is the viscosity and ${\Delta}p$ is the pressure drop. In present case, each hole has steps at both the inlet and the outlet, and the fluid appears compressible. So we simplify the equation as $Q=C(R,L){\Delta}p$. A series of performance curves for a through hole with geometric parameters were obtained using two-dimensional numerical simulation. We obtained a relation between the hole diameter and hole length from the test cases to determine hole diameter at fixed hole length. A numerical simulation has been performed as a tool for enhancing showerhead robust design from flow structure. Geometric parameters for the design were post distribution and face plate thickness. The reinforced showerhead has been installed and its effective deposition profile is being shown in factory.

  • PDF

A Study on the Algorithm for Single Phase Control of IGBT PWM Rectifier (IGBT PWM Rectifier의 각상 개별제어 알고리즘에 관한 연구)

  • Kim, Seung-Ho;Park, Jae-Beom;Tae, Dong-Hyun;Kim, Seung-Jong;Song, Joong-Ho;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.26-33
    • /
    • 2016
  • Recently, the use of transformer-less UPS has increased to improve the efficiency of UPS. However, transformer-less UPS is required in three-phase four-wire input IGBT PWM rectifier and the existing three-phase three-wire PFC algorithm cannot be applied in the three-phase four-wire system due to the neutral current problem of UPS input. To control the three-phase four-wire input IGBT PWM rectifier, there are two existing algorithms: 3D SVM and single phase control method. These two algorithms have advantages/disadvantages in controlling the rectifier. The single phase control method is unstable for controlling the rectifier and the 3D SVM method has a problem that must increase the L value of the input-side inductor considerably. Therefore, this paper proposes digital single phase control technology and another new algorithm considering the d-q control, to improve the characteristics of the existing control algorithm. In addition, this paper performed a simulation and experiment based on the proposed control algorithm. The simulation results showed that the proposed technology can control three-phase four-wire IGBT PWM rectifier in a stable manner and can also reduce the neutral current. The proposed algorithm is a useful tool for controlling the three-phase four-wire IGBT PWM rectifier.