• 제목/요약/키워드: Push-out bond strength

검색결과 65건 처리시간 0.021초

Bond behaviors of shape steel embedded in recycled aggregate concrete and recycled aggregate concrete filled in steel tubes

  • Chen, Zongping;Xu, Jinjun;Liang, Ying;Su, Yisheng
    • Steel and Composite Structures
    • /
    • 제17권6호
    • /
    • pp.929-949
    • /
    • 2014
  • Thirty one push-out tests were carried out in order to investigate the bond behavior between shape steel, steel tube (named steels) and recycled aggregate concrete (RAC), including 11 steel reinforced recycled aggregate concrete (SRRAC) columns, 10 recycled aggregate concrete-filled circular steel tube (RACFCST) columns and 10 recycled aggregate concrete-filled square steel tube (RACFSST) columns. Eleven recycled coarse aggregate (RCA) replacement ratios (i.e., 0%, 10%, 20%, 30%, 40%, 50%, 60%, 70%, 80%, 90% and 100%) were considered for SRRAC specimens, while five RCA replacement ratios (i.e., 0%, 25%, 50%, 75% and 100%), concrete type and length-diameter ratio for recycled aggregate concrete-filled steel tube (RACFST) specimens were designed in this paper. Based on the test results, the influences of all variable parameters on the bond strength between steels and RAC were investigated. It was found that the load-slip curves at the loading end appeared the initial slip earlier than the curves at the free end. In addition, eight practical bond strength models were applied to make checking computations for all the specimens. The theoretical analytical model for interfacial bond shear transmission length in each type of steel-RAC composite columns was established through the mechanical derivation, which can be used to design and evaluate the performance of anchorage zones in steel-RAC composite structures.

다양한 레진시멘트로 합착한 섬유포스트의 결합강도 비교 (COMPARISON OF BOND STRENGTH OF A FIBER POST CEMENTED WITH VARIOUS RESIN CEMENTS)

  • 이현아;조영곤
    • Restorative Dentistry and Endodontics
    • /
    • 제33권6호
    • /
    • pp.499-506
    • /
    • 2008
  • 이 연구는 다양한 접착시스템을 사용하는 6가지 레진시멘트를 이용하여 근관에 합착한 섬유포스트를 push-out 검사에 의해 포스트와 치근 상아질 간의 결합강도를 상호 비교하기 위하여 시행되었다. 발거된 하악 소구치의 치관부를 제거하고 치근부를 근관충전한 후 9mm의 포스트 룸을 형성하였다. 사용된 레진시멘트의 종류에 따라서 무작위로 6개씩 선택하여 Duo-Link 군, Variolink II 군, Panavia F 군, Multilink Automix 군, RelyX Unicem 군, Maxcem 군으로 분류하였다. 제조사의 지시에 따라서 각각의 레진시멘트를 Uni-dose needle tip을 이용하여 근단부에서부터 주입하여 광투과성 섬유 포스트인 no. 2 DT Light Post를 근관에 합착하였다. 증류수에 24시간동안 보관한 후, 주수 하에 저속의 Diamond Wheel Saw를 이용하여 각 치근을 횡단면으로 1mm 두께로 절단하여 연속적인 절편 6개를 얻었다. 각 군의 시편을 universal testing machine에 고정하고 push-out 검사를 시행하여 push-out 강도를 통계 분석한 결과, 서로 다른 접착시스템을 사용한 레진시멘트 군간의 push-out 강도는 유의한 차이가 나타나지 않았다 (p > 0.05).

Calcium silicate-based root canal sealers: a literature review

  • Lim, Miyoung;Jung, Chanyong;Shin, Dong-Hoon;Cho, Yong-bum;Song, Minju
    • Restorative Dentistry and Endodontics
    • /
    • 제45권3호
    • /
    • pp.35.1-35.17
    • /
    • 2020
  • Epoxy resin-based sealers are currently widely used, and several studies have considered AH Plus to be the gold-standard sealer. However, it still has limitations, including possible mutagenicity, cytotoxicity, inflammatory response, and hydrophobicity. Drawing upon the advantages of mineral trioxide aggregate, calcium silicate-based sealers were introduced with high levels of biocompatibility and hydrophilicity. Because of the hydrophilic environment in root canals, water resorption and solubility of root canal sealers are important factors contributing to their stability. Sealers displaying lower microleakage and stronger push-out bond strength are also needed to endure the dynamic tooth environment. Although the physical properties of calcium silicate-based sealers meet International Organization for Standardization recommendations, and they have consistently reported to be biocompatible, they have not overcome conventional resin-based sealers in actual practice. Therefore, further studies aiming to improve the physical properties of calcium silicate-based sealers are needed.

Residual bond behavior of high strength concrete-filled square steel tube after elevated temperatures

  • Chen, Zongping;Liu, Xiang;Zhou, Wenxiang
    • Steel and Composite Structures
    • /
    • 제27권4호
    • /
    • pp.509-523
    • /
    • 2018
  • This paper presents experimental results on the residual bond-slip behavior of high strength concrete-filled square steel tube (HSCFST) after elevated temperatures. Three parameters were considered in this test: (a) temperature (i.e., $20^{\circ}C$, $200^{\circ}C$, $400^{\circ}C$, $600^{\circ}C$, $800^{\circ}C$); (b) concrete strength (i.e., C60, C70, C80); (c) anchorage length (i.e., 250 mm, 400 mm). A total of 17 HSCFST specimens were designed for push-out test after elevated temperatures. The load-slip curves at the loading end and free end were obtained, in addition, the distribution of steel tube strain and the bond stress along the anchorage length were analyzed. Test results show that the shape of load-slip curves at loading ends and free ends are similar. With the temperature constantly increasing, the bond strength of HSCFST increases first and then decreases; furthermore, the bond strength of HSCFCT proportionally increases with the anchoring length growing. Additionally, the higher the temperature is, the smaller and lower the bond damage develops. The energy dissipation capacity enhances with the concrete strength rasing, while, decreases with the temperature growing. What is more, the strain and stress of steel tubes are exponentially distributed, and decrease from the free end to loading end. According to experimental findings, constitutive formula of the bond slip of HSCFST experienced elevated temperatures is proposed, which fills well with test data.

The effect of a diode laser and traditional irrigants on the bond strength of self-adhesive cement

  • Tuncdemir, Ali Riza;Yildirim, Cihan;Ozcan, Erhan;Polat, Serdar
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권4호
    • /
    • pp.457-463
    • /
    • 2013
  • PURPOSE. The purpose of this study was to compare the effect of a diode laser and traditional irrigants on the bond strength of self-adhesive cement. MATERIALS AND METHODS. Fifty-five incisors extracted due to periodontal problems were used. All teeth were instrumented using a set of rotary root canal instruments. The post spaces were enlarged for a No.14 (diameter, 1.4 mm) Snowlight (Abrasive technology, OH, USA) glass fiber reinforced composite post with matching drill. The teeth were randomly divided into 5 experimental groups of 11 teeth each. The post spaces were treated with the followings: Group 1: 5 mL 0.9% physiological saline; Group 2: 5 mL 5.25% sodium hypochlorite; Group 3: 5 mL 17% ethylene diamine tetra acetic acid (EDTA), Group 4: 37% orthophosphoric acid and Group 5: Photodynamic diode laser irradiation for 1 minute after application of light-active dye solution. Snowlight posts were luted with self-adhesive resin cement. Each root was sectioned perpendicular to its long axis to create 1 mm thick specimens. The push-out bond strength test method was used to measure bond strength. One tooth from each group was processed for scanning electron microscopic analysis. RESULTS. Bond strength values were as follow: Group 1 = 4.15 MPa; Group 2 = 3.00 MPa; Group 3 = 4.45 MPa; Group 4 = 6.96 MPa; and Group 5 = 8.93 MPa. These values were analysed using one-way ANOVA and Tukey honestly significant difference test (P<.05). Significantly higher bond strength values were obtained with the diode laser and orthophosphoric acid (P<.05). There were no differences found between the other groups (P> .05). CONCLUSION. Orthophosphoric acid and EDTA were more effective methods for removing the smear layer than the diode laser. However, the diode laser and orthophosphoric acid were more effective at the cement dentin interface than the EDTA, Therefore, modifying the smear layer may be more effective when a self-adhesive system is used.

Stress distribution in a passive fully grouted rock bolts

  • Karanam U. M. Rao;Dasyapu S. K.
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2003년도 Proceedings of the international symposium on the fusion technology
    • /
    • pp.122-128
    • /
    • 2003
  • Rock bolts are widely used as a supplementary roof support system in hard-rock mining since a long time. Since the performance of fully grouted passive bolts depends on bond strength, in the present investigation extensive laboratory pull-out as well as push-out tests were conducted varying the bolt diameter, length and cement-water mixing ratios of grout. The load-displacement curves were developed and were verified with the numerical results obtained from finite element analysis using ALGOR software. Numerical models were validated for push-out tests and a detailed analysis was carried out to know the displacement, stress, strain distribution along the bolt.

  • PDF

Retention of BioAggregate and MTA as coronal plugs after intracanal medication for regenerative endodontic procedures: an ex vivo study

  • Amin, Suzan Abdul Wanees;Gawdat, Shaimaa Ismail
    • Restorative Dentistry and Endodontics
    • /
    • 제43권3호
    • /
    • pp.18.1-18.12
    • /
    • 2018
  • Objectives: This study compared the retention of BioAggregate (BA; Innovative BioCeramix) and mineral trioxide aggregate (MTA; Angelus) as coronal plugs after applying different intracanal medications (ICMs) used in regenerative endodontic. Materials and Methods: One-hundred human maxillary central incisors were used. The canals were enlarged to a diameter of 1.7 mm. Specimens were divided into 5 groups (n = 20) according to the ICM used: calcium hydroxide (CH), 2% chlorhexidine (CHX), triple-antibiotic paste (TAP), double-antibiotic paste (DAP), and no ICM (control; CON). After 3 weeks of application, ICMs were removed and BA or MTA were placed as the plug material (n = 10). The push-out bond strength and the mode of failure were assessed. The data were analyzed using 2-way analysis of variance, the Tukey's test, and the ${\chi}^2$ test; p values < 0.05 indicated statistical significance. Results: The type of ICM and the type of plug material significantly affected bond strength (p < 0.01). Regardless of the type of ICM, BA showed a lower bond strength than MTA (p < 0.05). For MTA, CH showed a higher bond strength than CON, TAP and DAP; CHX showed a higher bond strength than DAP (p < 0.01). For BA, CH showed a higher bond strength than DAP (p < 0.05). The mode of failure was predominantly cohesive for BA (p < 0.05). Conclusions: MTA may show better retention than BA. The mode of bond failure with BA can be predominantly cohesive. BA retention may be less affected by ICM type than MTA retention.

Glass Fiber Post와 Composite Resin Core의 전단결합강도 (A STUDY FOR THE BONDING STRENGTH OF COMPOSITE RESIN CORE TO GLASS FIBER POST)

  • 김태형;심준성;이근우
    • 대한치과보철학회지
    • /
    • 제43권4호
    • /
    • pp.415-425
    • /
    • 2005
  • Statement of problem : Fracture of composite resin core will be occulted by progress of crack. Bonding interface of different materials has large possibility of starting point of crack line. Therefore, the bond strength of glass fiber post to composite resin core is important for prevention of fracture. Purpose: This in vitro study tried to find out how to get the higher strength of glass fiber post to composite resin core through surveying the maximum load that fractures the post and cote complex. Materials and methods: 40 specimens made with glass fiber Posts(Style $post^{(R)}$, Metalor, Swiss) and composite resin core ($Z-100^{(R)}$, 3M, USA) were prepared and loaded to failure with push-out type shear-bond strength test in a universal test machine. The maximum fracture load and fracture mode were investigated in the specimens that were restored with four different surface treatments. With the data. ANOVA test was used to validate the significance between the test groups, and Bonferroni method was used to check if there is any significant statistical difference between each test group. Evely analysis was approved with 95% reliance. Results: On measuring the maximum fracture load of specimens, both the treatments of sandblasted and acid-etched one statistically showed the strength increase rather than the control group (p<0.005). The scanning electric microscope revealed that sand blasting made more micro-retention form not only on the resin matrix but on the glass fiber, and acid-etching contributed to increase in surface retention form, eliminated the inorganic particles in resin matrix. Specimen fracture modes investigation represented that sand blasted groups showed lower bonding failure than no-sand blasted groups. Conclusion: Referring to the values of maximum fracture load of specimens, the bonding strength was increased by sand blasting and acid-etching.

Effects of radiation therapy on the dislocation resistance of root canal sealers applied to dentin and the sealer-dentin interface: a pilot study

  • Pallavi Yaduka;Rubi Kataki;Debosmita Roy;Lima Das;Shachindra Goswami
    • Restorative Dentistry and Endodontics
    • /
    • 제46권2호
    • /
    • pp.22.1-22.12
    • /
    • 2021
  • Objectives: This study evaluated and compared the effects of radiation therapy on the dislocation resistance of AH Plus and BioRoot RCS applied to dentin and the sealer-dentin interface. Materials and Methods: Thirty single-rooted teeth were randomly assigned to 2 groups (n = 15 each): AH Plus (Dentsply DeTrey) and BioRoot RCS (Septodont). Each group was subdivided into control and experimental groups. The experimental group was subjected to a total radiation dose of 60 Gy. The root canals of all samples were cleaned, shaped, and obturated using the single-cone technique. Dentin slices (1 mm) were sectioned from each root third for the push-out test and scanning electron microscopy (SEM) was done to examine the sealer-dentin interface. The failure mode was determined using stereomicroscopy. Bond strength data were analyzed by the independent t-test, 1-way analysis of variance, and the Tukey post hoc test (α = 0.05). Results: Significantly lower bond strength was observed in irradiated teeth than non-irradiated teeth in the AH Plus group (p < 0.05). The BioRoot RCS group showed no significant reduction in bond strength after irradiation (p > 0.05) and showed a higher post-irradiation bond strength (209.92 ± 172.26 MPa) than the AH Plus group. SEM revealed slightly larger gap-containing regions in irradiated specimens from both groups. Conclusions: The dislocation resistance of BioRoot RCS was not significantly changed by irradiation and was higher than that of AH Plus. BioRoot RCS may be the sealer of choice for root canal treatment in patients undergoing radiation therapy.

FRC-포스트의 표면처리가 레진시멘트와의 접착력에 미치는 영향 (Effect of surface treatment of FRC-Post on bonding strength to resin cements)

  • 박찬현;박세희;김진우;조경모
    • Restorative Dentistry and Endodontics
    • /
    • 제36권2호
    • /
    • pp.125-131
    • /
    • 2011
  • 연구목적: Silane 처리가 FRC-포스트와 레진 시멘트 간의 결합강도에 미치는 영향을 알아보고자 하였다. 연구 재료 및 방법: FRC-포스트로 LuxaPost (DMG)와 Rely-X Fiber Post (3M ESPE)를 사용하였으며 자가 접착 레진 시멘트인 Rely-X Unicem (3M ESPE)과 전통형 레진시멘트인 Rely-X ARC (3M ESPE)와의 Rely-X Ceramic Primer (3M ESPE)를 이용한 표면처리 유무에 따른 결합강도를 push-out test를 실시하여 측정하고 independent samples t-test 및 one-way ANOVA와 Scheffe 사후검정을 95% 유의수준에서 실시하였다. 결과: 실험 결과 Rely-X Fiber Post를 사용한 실험군에서 silane 처리와 관계없이 Rely-X ARC를 적용하였을 때, 다른 실험군들에 비해 높은 결합 강도가 나타났으며 LuxaPost를 사용한 실험군에서 각각의 레진 시멘트에 대해 silane 처리를 하였을 때 시행하지 않은 실험군에 비해 높은 결합 강도가 나타났다. 결론: 이상의 실험 결과로 볼 때 미리 silane 처리된 LuxaPost를 사용하더라도 silane 처리를 시행하는 것이 좋은 것으로 생각된다.