• Title/Summary/Keyword: Purification facility

Search Result 73, Processing Time 0.037 seconds

A Study on the Purification of Water-Pool in Irradiated Materials Examination Facility

  • Song, Ung-Sup;Lee, Jong-Heon;Lee, Hong-Gyee;Hong, Kyon-Pyo
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.02a
    • /
    • pp.42-50
    • /
    • 2004
  • The pool $(3m{\times}6m{\times}10m{\times}$ in Irradiated Materials Examination Facility is generally used to transport irradiated materials between a moving cask and hot-cell. During the operation in the pool such as loading/unloading the cask, holding specimen and bucket elevation, water maybe contaminated by radioactive or contaminated impurities from irradiated materials. Then, it must be purified and filtered continuously to keep lower radioactivity than that of regulation prescribed by RCA Korea Activity in a part of radioactive contamination control. This paper described radioactive contamination distribution of water as transported materials, which is related to effective operation of purification and filtration system.

  • PDF

Recombinant Expression, Isotope Labeling and Purification of the Vitamin D Receptor Binding Peptide

  • Chae, Young-Kee;Singarapu, Kiran;Westler, W. Milo;Markley, John L.
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.12
    • /
    • pp.4337-4340
    • /
    • 2011
  • The vitamin D receptor binding peptide, VDRBP, was overexpressed as a fused form with the ubiquitin molecule in Rosetta(DE3)pLysS, a protein production strain of Escherichia coli harboring an induction controller plasmid. The fusion protein was bound to the immobilized metal ions, and the denaturation and renaturation of the fusion protein were performed as a part of the purification procedure. After the elution of the fusion protein, the peptide hormone was released from its fusion partner by using yeast ubiquitin hydrolase (YUH), and subsequently purified by reverse phase chromatography. The purity of the resulting peptide fragment was checked by MALDI-TOF mass and NMR spectroscopy. The final yields of the target peptide were around 5 and 2 mg per liter of LB and minimal media, respectively. The recombinant expression and purification of this peptide will enable structural and functional studies using multidimensional NMR spectroscopy and X-ray crystallography.

A Study on the Design and Embodiment of Educational Automatic Purification Facility of Waste Water (교육용 자동 폐수 정화시설의 설계와 구현에 관한 연구)

  • Kim, Moon-Ki
    • The Journal of Korean Institute for Practical Engineering Education
    • /
    • v.4 no.2
    • /
    • pp.7-12
    • /
    • 2012
  • In this research, an educational automatic purification facility of waste water is designed. The system has four functions which are filter tank, aeration tank, reactor tank and ultraviolet sterilization tank, and is embodied by PLC(Programmable Logic Controller), DC motor, solenoid valve, squirt gun, propeller, profile, switch, sensor and so on. Also, the system is designed and manufactured based on knowledges which are obtained from college education. The study is emphasized on "learning by doing". From this case study, students can increase their originality and adaptability for related industry. Also, the technique can be initiated industry if needed.

  • PDF

A concerned party of purification liability for soil pollution (토양오염에 대한 정화책임의 주체)

  • 조은래
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1999.10a
    • /
    • pp.53-56
    • /
    • 1999
  • The concerned party of purification liability in a soil pollution is an owner or occupant of a contaminated site. But when we don't appoint the polluter or he can't do a cleanup, municipal put in effect the purification. In such a case, another parties who are related to the contamination ought to the liability. The province of responsible parties, therefore, is required to extend to an owner or operator of a facility, a carrier and lender

  • PDF

A Study on the Characteristics of Livestock Manure Treatment Facility in Korea (국내 가축분뇨 처리시설 형태별 특성조사 분석)

  • Jeong, Kwang-Hwa;Kim, Jung-Kon;Khan, Modabber Ahmed;Han, Duk-Woo;Kwag, Jung-Hoon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.22 no.4
    • /
    • pp.28-44
    • /
    • 2014
  • Due to development of the national economy growth, livestock goods consumption has rapidly increased over the past 30 years. It has led livestock breeders to increase their livestock numbers. An increased number of livestock have consequently resulted in an increasing animal feces generation. According to the agricultural statistics provided by the Bureau of Statistics, livestock manure amounts to 47,235 thousand tons in 2013. To treat livestock manure, various types of treatment facilities like composting, liquid fertilization, purification, and anaerobic digestion facilities are being applied. In composting facility, there are four kinds of agitation system: escalator, paddle, screw and rotary type. In case of liquid fertilization process, there are two types of system: aeration and anoxic type. There are about 8,000 liquid fertilization facilities for treatment livestock manure in Korea. For purification of livestock manure, the treatment process is divided by three steps: Solid/Liquid separation process, Secondary purification process and advanced oxidation process. About 21 thousand tons of livestock manure was treated by anaerobic digestion facility in 2012. In every type of facility for livestock manure treatment, it is very important to choose the optimal deodorization equipment for the livestock manure treatment facility. In this study, the investigation has been carried out for six years to analyse the characteristics of livestock manure treatment facilities and related technique of Korea.

Odor Reduction Technology in Sewage Treatment Facility Using Biofilter with Reed Grass(Phragmites australls) (갈대(Phragmites australls)수초를 적용한 바이오필터에서의 하수처리시설 악취저감기술)

  • Chung, Jin-Do;Kim, Kyu-Yeol
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.3
    • /
    • pp.373-382
    • /
    • 2013
  • In this study, a biological odor treatment system was proposed to remove odor(foul smell) materials causing several problems in the closed sewage treatment plant. This odor treatment system was composed of a two-step biofilter system in one reactor. The two-step biofilter reactor was constructed with natural purification layer in upper part and artificial purification layer in lower part. The reed grasses of water purification plants were planted in the surface area and mixed porous ceramic media were filled with the lower part of biofilter reactor. By using the above experimental apparatus, the ammonia gas removal efficiency was attained to 98.3 % and the hydrogen sulfide gas removal efficiency was appeared more than 97.7 % which shows more effective than the conventional odor removal process.

Investigation on the Excessive Vibration of A Mixer Facility in A Water Purification Plant (정수장용 교반기 시설의 과진동 원인 분석)

  • Park, Jin-Ho;Lee, Jeong-Han;Kim, Bong-Soo;Kang, Mun-Hu;Kim, Dong-Soo;Joo, Yoon-Sik
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.312-316
    • /
    • 2002
  • Recently, mixers are being widely used in the water purification plant in order to increase the filtration efficiency. It has been found that a severe vibration was being felt on a upper structure of a mixer facility during steady state operation. The cause of the excessive vibration of the structure to which the mixer's shaft is supported has been evaluated through modal analysis on the shaft and vibration measurements during operation. The fundamental natural frequency of the mixer's shaft is found to be around 1.8 Hz and the main vibratory frequency around 30 Hz. It has been tuned out that the main vibratory frequency, 30 Hz is coincident with the fundamental holding frequency of the upper structure, and that the acceleration signal of the upper structure and the displacement signal of the mixer's shaft showed highly coherent to each other. Accordingly, it reveals that the main cause of the excessive vibration is due not to the mixer's vibration but to the natural frequency of the upper structure excited by flow turbulence.

  • PDF

Development and Application of a Water Quality Model to Assess Water Purification Techniques for Lakes and Reservoirs (호소수질정화공법의 평가를 위한 수질모형의 개발 및 적용)

  • 박병흔;권순국;장정렬
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.43 no.6
    • /
    • pp.174-186
    • /
    • 2001
  • Excessive outflow of pollutant loads resulting from rapid industrialization has unbalanced the water ecosystem, deteriorating the water quality environment severely. Therefore, measures for improving the water quality are necessary to maintain clean reservoir water and restore water-friendly spaces. A water quality model which is capable of simulating daily reservoir water quality was developed. The model had been applied to Masan reservoir and Wanggung reservoir in Korea. The model appeared to be satisfactory in representing the trend of water quality variations by comparing measured and simulated results. The model had been also applied to assess water purification techniques such as dredged pool, floating island and vegetation purification system. The model was considered to assess the effect of water purification techniques on reservoir water quality improvement. The results of water quality simulation for lake water purification techniques showed that a large facility would be needed to meet the targeted water quality of the reservoir when only one technique is applied. To effectively improve the quality of the polluted reservoir water, it is therefore recommended that pollutant sources should first be controlled, and a combination of the water purification techniques applied to make the utmost use of their secondary effects such as conservation of the reservoir volume capacity, establishment of a recreation space, promotion of bio-diversity, and improvement of the lake landscape.

  • PDF

Identification of Major Fungi and Bacterial Species in Solid Medium Drainage for Circulating Hydroponics System (수경재배 배액 재이용을 위한 주요 곰팡이 및 박테리아 종 파악)

  • Lee, Donggwan;Son, Jinkwan;Kang, Taegyeong;Jang, Jaekyung;Park, Minjung;Lee, Taeseok;Lim, Ryugap
    • Journal of Environmental Science International
    • /
    • v.29 no.11
    • /
    • pp.1109-1123
    • /
    • 2020
  • In this study, the amount of harmful fungi and bacteria contained in the drainage and culture medium from the paprika hydroponic facility is identified. In addition, by proposing the necessity of effective purification of discharged drainage, this study attempted to confirm the possibility of drainage reuse. Finally, this study provides basic data on the basis for calculating the need for purification facilities in the future, as well as improvements in horticulture facility for sustainable agriculture. As a result of the analysis, a total of 12 types of fungi were detected in paprika medium and 10 types of fungi were detected in the drainage, and their densities were 130 and 68, respectively. Among the fungi detected in the media and drainage of the paprika hydroponic facility, the fungi with the highest detection frequency are Fusarium, Phytophthora, and Pythium. In the case of bacteria, a total of 2 types of bacteria were detected in the paprika facilities, and the density was 28 and 23, respectively. Therefore, in order to reuse the drainage and settle the circulating hydroponic cultivation system, a water treatment process capable of appropriate treatment is required.

Investigation on the Excessive Vibration of A Mixer Facility in A Water Purification Plant (정수장용 교반기 시설의 과진동 원인 분석)

  • Park, Jinho;Lee, Jeong-Han;Kim, Bong-Soo;Kang, Mun-Hu;Kim, Dong-Soo;Joo, Yoon-Sik
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.336.1-336
    • /
    • 2002
  • Recently, mixers are being widely used in the water purification plant in order to increase the filtration efficiency. The cause of an excessive vibration of a base structure to which the mixers are supported, has been evaluated through modal analysis on the mixer shaft and vibration measurements during operation. The fundamental natural frequency of the mixer shaft is found to be around 1.8 Hz and the main vibratory frequency around 30 Hz. (omitted)

  • PDF