• 제목/요약/키워드: Pure refrigerant

검색결과 78건 처리시간 0.022초

실내 부하 변동에 따른 탄화수소계 냉매를 이용한 히트펌프 성능에 관한 실험적 연구 (An Experimental Study on Performance of Heat Pump System Using Hydrocarbon Refrigerants by Changing Indoor Load)

  • 김재돌;성광훈;정석권;윤정인;이호생
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권2호
    • /
    • pp.204-210
    • /
    • 2006
  • This study presents heat pump system characteristics using hydrocarbon refrigerants as alternative refrigerant for R-22 with respect to the variation of indoor load. Pure R-22 and R-290. R-600a, R-1270 were considered as working fluids The experimental apparatus was constructed to investigate the performance of heat pump using the air as a heat source. The performance were calculated based on compression shaft work. refrigeration capacity. pressure ratio, discharge temperature and COP. The experimental results show that the COP and refrigeration capacity of hydrocarbon refrigerants were higher than that of R-22. Through the above. hydrocarbon refrigerants are good alternatives in the heat pump system for R-22.

두 개의 온도 의존 매개변수가 있는 3차 상태방정식의 성능비교 (Performance Comparison of Cubic Equations of State With Two Temperature Dependent Parameters)

  • 권영욱;박경근
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.205-210
    • /
    • 2001
  • Cubic equations of state with two temperature dependent parameters are suggested and optimized using ASHRAE data for methane, propane, carbon dioxide, R-32 and R-134a. Appropriate simple functional forms are assumed for the temperature dependent parameters. The equations tested are Martin, Fuller, Harmens-Knapp, Schmidt-Wenzel. Among them modified Schmidt-Wenzel equation of state appears to be the choice for calculation of saturation properties such as vapor pressures, saturated liquid volumes, and saturated vapor volumes with an average absolute deviation of about one percent over the entire region excluding; the near cirtical.

  • PDF

나노 윤활유를 이용한 스크롤 압축기 스러스트 베어링의 윤활특성 평가 (Performance Evaluation of Nano-Lubricants at Thrust Slide-Bearing of Scroll Compressor)

  • 조한종;조용일;조상원;이재근;박민찬;김대진;이광호
    • 한국정밀공학회지
    • /
    • 제29권1호
    • /
    • pp.121-125
    • /
    • 2012
  • This paper presents the friction and anti-wear characteristics of nano-oil with a mixture of a refrigerant oil and carbon nano-particles in the thrust slide-bearing of scroll compressors. Frictional loss in the thrust slide-bearing occupies a large part of total mechanical loss in scroll compressors. The characteristics of friction and anti-wear using nano-oil is evaluated using the thrust bearing experimental apparatus for measuring friction surface temperature and the coefficient of friction at the thrust slide-bearing as a function of normal loads up to 4,000 N and rotating speed up to 3,200 rpm. It is found that the coefficient of friction increases with decreasing rotating speed and normal force. The friction coefficient of carbon nano-oil is 0.023, while that of pure oil is 0.03 under the conditions of refrigerant gas R-22 at the pressure of 5 bars. It is believed that carbon nano-particles can be coated on the friction surfaces and the interaction of nano-particles between surfaces can be improved the lubrication in the friction surfaces. Carbon nano-oil enhances the characteristics of the anti-wear and friction at the thrust slide-bearing of scroll compressors.

마이크로 휜 증발관내 냉매 R-290의 열전달 특성에 미치는 냉동유의 영향 (Influence of Refrigeration Oil on Evaporation Heat Transfer Characteristics of R-290 Inside Micro Fin Tube)

  • 박철민;안영태;이욱현;김정훈;김종수
    • 대한기계학회논문집B
    • /
    • 제24권7호
    • /
    • pp.938-944
    • /
    • 2000
  • Recently, micro fin tube is widely used to heat exchanger for high performance. And, as the alternative refrigerants for R-22, hydrocarbons such as R-290, R-600 and R-600a are very promising because of their low GWP and ODP. Thus, R-290 was used as working fluid in this study. Most design of heat exchanger had been based on heat transfer characteristics of pure refrigerant although refrigerant oil exists in the refrigeration cycles. So, the influence of oil on heat transfer characteristics have to be considered for investigating exact evaporation heat transfer characteristics. But, this is an unresolved problem of refrigeration heat transfer. Therefore the influence of the refrigeration oil to the evaporation heat transfer characteristics of R-290 were conducted in a horizontal micro tin tube. The mineral oil was used as refrigeration oil. The experimental apparatus consisted of a basic refrigeration cycle and a system for oil concentration measurement. Test conditions are as the follows; evaporation temperature $5^{\circ}C$, mass velocity 100 $kg/m^2s$, heat flux 10 $kW/m^2$, oil concentration 0, 1.3, 3.3, 5.7 wt.%, and quality $0.07{\sim}1.0$. When refrigeration oil was entered, oil foaming was observed at the low quality region. And, very small bubbles were observed as quality was increased. Pressure drop and heat transfer coefficient increased as the concentration of refrigeration oil increased to 5 wt.%.. The performance index of heat exchanger was the highest near 3.3 wt.%.

다공도가 다른 전열촉진관의 냉매 풀비등에 미치는 오일의 영향 (Effect of Oil on Pool Boiling of Refrigerant on Enhanced Tubes having Different Pore Sizes)

  • 김내현;이응렬;민창근
    • 설비공학논문집
    • /
    • 제18권3호
    • /
    • pp.254-261
    • /
    • 2006
  • The effect of enhanced geometry (pore diameter, gap width) is investigated on the pool boiling of R-123/oil mixture for the enhanced tubes having pores with connecting gaps. Tubes with different pore diameters (and corresponding gap widths) are specially made. Significant heat transfer degradation by oil is observed for the present enhanced tubes. At 5% oil concentration, the degradation is 26 to 49% for $T_{sat}=4.4^{\circ}C$. The degradation increases 50 to 67% for $T_{sat}=26.7^{\circ}C$. The heat transfer degradation is significant even with small amount of oil (20 to 38% degradation at 1% oil concentration for $T_{sat}=4.4^{\circ}C$), probably due to the accumulation of oil in sub-tunnels. The pore size (or gap width) has a significant effect on the heat transfer degradation. The maximum degradation is observed for $d_p$ = 0.20 mm tube at $T_{sat}=4.4^{\circ}C$, and for $d_p$=0.23 mm tube at $T_{sat}=26.7^{\circ}C$. The minimum degradation is observed for $d_p$=0.27 mm tube for both saturation temperatures. It appears that the oil removal is facilitated for the larger pore diameter (along with larger gap) tube. The highest heat transfer coefficient with oil is obtained for $d_p$ =0.23 mm tube, which yielded the highest heat transfer coefficient for pure R-123. The heat transfer degradation increases as the heat flux decreases.

나노 윤활유를 이용한 스크롤 압축기 스러스트 베어링의 윤활특성 평가 (Performance Evaluation of Nano-Lubricants at Thrust Slide-Bearing of Scroll Compressors)

  • 조상원;김홍석;안영철;이정언;이재관;이형국;이병철;김동한;박진성
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.1219-1224
    • /
    • 2006
  • This paper presents the friction and anti-wear characteristics of nano-oil with n mixture of a refrigerant oil and carbon nano-particles in the thrust slide-bearing of scroll compressors. Frictional loss in the thrust slide-bearing occupies a large part of total mechanical loss in scroll compressors. The characteristics of friction and anti-wear Lising nano-oil is evaluated using the thrust bearing tester for measuring friction surface temperature and the coefficient of friction at the thrust slide-bearing as a function of normal loads up to 4,000 N and orbiting speed up to 3,200 rpm. It is found that the coefficient of friction increases with decreasing orbiting speed and normal force. The friction coefficient of carbon nano-oil is 0.015, while that of pure oil is 0.023 under the conditions of refrigerant gas R-22 at the pressure of 5 bars. It is believed that carbon nano-particles can be coated on the friction surfaces and the interaction of nano-particles between surfaces can be improved the lubrication in the friction surfaces. Carbon nano-oilenhances the characteristics of the anti-wear and friction at the thrust slide-bearing of scroll compressors.

  • PDF

HCFC22 대체 R290, R1270 및 R1270/R290, R290/HFC152a, R1270/R290/RE170 혼합냉매의 공기조화기와 열펌프 작동범위에서의 성능 평가 (Performance of HCFC22 Alternatives R1270, R290, R1270/R290, R290/HFC152a, R1270/R290/RE170 Refrigerants for Air-conditioning and Heat Pump Applications)

  • 황지환;백인철;정동수
    • 설비공학논문집
    • /
    • 제18권4호
    • /
    • pp.312-319
    • /
    • 2006
  • In this study, performance of 2 pure hydrocarbons and 7 mixtures was measured in an attempt to substitute HCFC22 used in air-conditioners and heat pumps. The mixtures were composed of R1270 (propylene), R290 (propane), HFC152a, and RE170 (Dimethyl ether, DME). The pure and mixed refrigerants tested have GWPs of $3{\sim}58$ as compared to that of $CO_2$ and the mixtures are all near-azeotropic showing the gliding temperature difference (GTD) of less than $0.6^{\circ}C$. Thermodynamic cycle analysis was carried out to determine the optimum compositions and actual tests were performed in a laboratory heat pump test bench at the evaporation and condensation temperatures of 7.5 and $45.1^{\circ}C$ respectively. Test results show that the coefficient of performance (COP) of these mixtures is up to 5.7% higher than that of HCFC22. While propane showed 11.5% reduction in capacity, most of the fluids tested had the similar capacity to that of HCFC22. Compressor discharge temperatures were reduced by $11{\sim}17^{\circ}C$ with these fluids. There was no problem with mineral oil since the mixtures were mainly composed of hydrocarbons. The amount of charge was reduced up to 55% as compared to HCFC22. Overall, these fluids provide good performance with reasonable energy savings without any environmental problem and thus can be used as long term alternatives for. residential air-conditioning and heat pumping application.

GERG-2004 모델식과 Peng-Robinson 상태방정식을 이용한 천연가스 및 냉매 구성성분들의 물성 비교연구 (Comparative Study on the Properties Estimation of the Constituents of the Natural Gas and Refrigerant Mixtures Between GERG-2004 Model and Peng-Robinson Equation of State)

  • 김미진;노재현;김동선;조정호
    • 한국산학기술학회논문지
    • /
    • 제13권2호
    • /
    • pp.906-918
    • /
    • 2012
  • 본 연구에서는 천연가스 및 냉매를 구성하고 있는 성분들에 대한 증기압, 증발잠열, 액상의 밀도 및 이성분계 기액 상평형을 추산하는데 있어서 GERG-2004 모델식과 Peng-Robinson(PR) 상태방정식을 서로 비교하였다. 비교결과 GERG-2004모델식은 액상의 밀도 추산에 있어서 PR 상태방정식에 비해 정확성이 높았으나, 기액 상평형 추산에 대한 정확성은 오히려 낮았다. 한편, PR 상태방정식에서 Costald 상관 관계식을 사용하여 액상의 밀도를 추산한 경우에는 실험값과 오차율이 1% 이내로써 GERG-2004 모델식을 사용한 추산 결과와 거의 차이가 없었으며, 증기압과 증발 잠열의 추산은 GERG-2004모델식과 PR 상태방정식이 거의 유사한 결과를 나타냄을 알 수 있었다.

HFC152a, HFC134a, 프로판을 포함한 자동차용 대체/보충 냉매의 성능 (Performance of HFC152a, HFC134a and HC290 Mixtures as Alternative Refrigerants for HFC134a)

  • 강남구;배근환;박기정;정동수
    • 설비공학논문집
    • /
    • 제22권6호
    • /
    • pp.383-391
    • /
    • 2010
  • In this study, HFC152a, HFC134a/HFC152a and HC290/HFC134a/HFC152a mixtures are studied for the supplementary and alternative refrigerants for HFC134a used in automobile air-conditioners. Due to the high global warming potential of HFC134a, it has to be phased out in the long run. Thermodynamic performance of these refrigerants are measured in a bench tester of 3.5 kW capacity with an open type compressor under both summer and winter conditions. Test results show that the coefficient of performance (COP) and capacity of pure HFC152a and HFC134a/HFC152a mixture are 9.1~12% and 7% higher than those of HFC134a. As for the HC290/HFC134a/HFC152a, the COP is up to 9.5% higher than that of HFC134a with 1~2% of HC290 while that is up to 6.1% lower than that of HFC134a with 5% HC290. The capacity of the ternary mixture, however, is 8.6% higher than that of HFC134a at all compositions tested. The compressor discharge temperatures of all refrigerants tested are $6{\sim}10^{\circ}C$ higher than that of HFC134a. For all refrigerants, the amount of charge is reduced up to 32% due to the decrease in liquid density. Overall, these refrigerants provide good performance with reasonable energy savings with less environmental problem and thus can be used as long term alternatives for automobile air-conditioners.

천연가스 액화공정의 최적설계 (Optimal Design of Natural Gas Liquefaction Processes)

  • 조현준;여영구;김진국
    • Korean Chemical Engineering Research
    • /
    • 제51권1호
    • /
    • pp.25-34
    • /
    • 2013
  • 본 총설에서는 천연가스 액화공정의 최적설계에서 에너지 효율을 높이기 위해 고려해야 하는 주요 공정설계 인자들에 대한 논의와 상용 LNG 플랜트에서 이러한 인자들이 어떻게 적용되고 있는지에 대하여 살펴보았다. 압축기에서 소모되는 축일의 양을 최소화하기 위한 방법으로서 단일 냉매를 사용하는 냉각 사이클을 다단, 혹은 중첩 구조로 설계하여 온도 범위가 넓은 영역에서 운용하는 방법과 혼합냉매를 사용하여 단순한 사이클 구조를 유지하면서 최적 냉각공급 곡선을 유지하는 방법을 다루었고, 천연가스 액화조건에 맞추어 이러한 구조들의 최적 조합을 구성하는 원리를 소개하였다. 열 통합(heat integration) 기법을 활용하여 상용화 공정들의 특징을 도식적으로 고찰하였으며 아울러 에너지 효율 및 경제성에 대한 분석을 수행하였다. 또한 액화 공정 설계에서 사용되는 대용량의 압축기들을 구동하는 에너지 시스템에 대한 설계 문제를 살펴보았으며 최적설계를 위한 여러 가지 요소들을 고찰하여 보았다.