• Title/Summary/Keyword: Pupil

Search Result 449, Processing Time 0.025 seconds

IGRINS First Light Instrumental Performance

  • Park, Chan;Yuk, In-Soo;Chun, Moo-Young;Pak, Soojong;Kim, Kang-Min;Pavel, Michael;Lee, Hanshin;Oh, Heeyoung;Jeong, Ueejeong;Sim, Chae Kyung;Lee, Hye-In;Le, Huynh Anh Nguyen;Strubhar, Joseph;Gully-Santiago, Michael;Oh, Jae Sok;Cha, Sang-Mok;Moon, Bongkon;Park, Kwijong;Brooks, Cynthia;Ko, Kyeongyeon;Han, Jeong-Yeol;Nah, Jakyuong;Hill, Peter C.;Lee, Sungho;Barnes, Stuart;Park, Byeong-Gon;T., Daniel
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.1
    • /
    • pp.52.2-52.2
    • /
    • 2014
  • The Immersion Grating Infrared Spectrometer (IGRINS) is an unprecedentedly minimized infrared cross-dispersed echelle spectrograph with a high-resolution and high-sensitivity optical performance. A silicon immersion grating features the instrument for the first time in this field. IGRINS will cover the entire portion of the wavelength range between 1.45 and $2.45{\mu}m$ accessible from the ground in a single exposure with spectral resolution of 40,000. Individual volume phase holographic (VPH) gratings serve as cross-dispersing elements for separate spectrograph arms covering the H and K bands. On the 2.7m Harlan J. Smith telescope at the McDonald Observatory, the slit size is $1^{\prime\prime}{\times}15^{\prime\prime}$. IGRINS has a $0.27^{\prime\prime}$ pixel-1 plate scale on a $2048{\times}2048$ pixel Teledyne Scientific & Imaging HAWAII-2RG detector with SIDECAR ASIC cryogenic controller. The instrument includes four subsystems; a calibration unit, an input relay optics module, a slit-viewing camera, and nearly identical H and K spectrograph modules. The use of a silicon immersion grating and a compact white pupil design allows the spectrograph collimated beam size to be 25mm, which permits the entire cryogenic system to be contained in a moderately sized rectangular vacuum chamber. The fabrication and assembly of the optical and mechanical hardware components were completed in 2013. In this presentation, we describe the major design characteristics of the instrument and the early performance estimated from the first light commissioning at the McDonald Observatory.

  • PDF

Performance Prediction of a Laser-guide Star Adaptive Optics System for a 1.6 m Telescope

  • Lee, Jun Ho;Lee, Sang Eun;Kong, Young Jun
    • Current Optics and Photonics
    • /
    • v.2 no.3
    • /
    • pp.269-279
    • /
    • 2018
  • We are currently investigating the feasibility of a 1.6 m telescope with a laser-guide star adaptive optics (AO) system. The telescope, if successfully commissioned, would be the first dedicated adaptive optics observatory in South Korea. The 1.6 m telescope is an f/13.6 Cassegrain telescope with a focal length of 21.7 m. This paper first reviews atmospheric seeing conditions measured over a year in 2014~2015 at the Bohyun Observatory, South Korea, which corresponds to an area from 11.6 to 21.6 cm within 95% probability with regard to the Fried parameter of 880 nm at a telescope pupil plane. We then derive principal seeing conditions such as the Fried parameter and Greenwood frequency for eight astronomical spectral bands (V/R/I/J/H/K/L/M centered at 0.55, 0.64, 0.79, 1.22, 1.65, 2.20, 3.55, and $4.77{\mu}m$). Then we propose an AO system with a laser guide star for the 1.6 m telescope based on the seeing conditions. The proposed AO system consists of a fast tip/tilt secondary mirror, a $17{\times}17$ deformable mirror, a $16{\times}16$ Shack-Hartmann sensor, and a sodium laser guide star (589.2 nm). The high order AO system is close-looped with 2 KHz sampling frequency while the tip/tilt mirror is independently close-looped with 63 Hz sampling frequency. The AO system has three operational concepts: 1) bright target observation with its own wavefront sensing, 2) less bright star observation with wavefront sensing from another bright natural guide star (NGS), and 3) faint target observation with tip/tilt sensing from a bright natural guide star and wavefront sensing from a laser guide star. We name these three concepts 'None', 'NGS only', and 'LGS + NGS', respectively. Following a thorough investigation into the error sources of the AO system, we predict the root mean square (RMS) wavefront error of the system and its corresponding Strehl ratio over nine analysis cases over the worst ($2{\sigma}$) seeing conditions. From the analysis, we expect Strehl ratio >0.3 in most seeing conditions with guide stars.

A Study on The Fruits Mentioned in the Bible (성서에 언급된 과실에 관한 연구)

  • Kim, Sung-Mee;Lee, Kwang
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.9 no.2
    • /
    • pp.149-160
    • /
    • 1999
  • This paper is intended to find out what kinds of fruits are mentioned in the Bible and how they were used in those days. It has also analyzed in what terms they are expressed in the Korean Version of the Bible and studied agricultural regulations involved in the religion, and allegorical uses of the fruits. Olives were the primary fruit in the economy of the ancient times, followed by figs and vines. In addition, there are mentioned in the Bible almonds, apples, dates. mulberries and pomegranates. Olive trees have been grown for more than six thousand years. The Hebrew word. Zayit is mentioned in the Bible more than fifty times. Olive trees are not so beautiful in themselves but as they give us humans abundant reap and a lot of oil, they have been thought to be beautiful. Olive trees grow well on the seaside in the salty air and fog. Vines began to grown as early as in the Bronze Age(the period of 3000 to 2000 B.C.). In Northern Greece, grape seeds were found to belong to the year 4500 B.C. or so. The vine gardens produced raisins and wine as well as vines. Figs are the fruit which are first mentioned in the Bible(Genesis 3:7) and they were the precious product of the Palestine people, which is described in Deuteronomy 8:8. Figs are sweet and watery and can easily quench thirst on hot summer days. They were used for cookies and wine in the raw or dried state. An apple, which is tappuah in Hebrew, is mentioned as 'Sagwa' six times in the Revised Korean Version, and in the Korean Joint Version it is twice mentioned as 'Sagwa' and as 'Neungum' four times. In ASV and KJV, 'apple' appears eleven times. which is because' the apple of eye' is translated in the 'Nun-dong-ja(the pupil of the eye)'In the Korean Version. 'Sagwa(apple)'of Proverb 25:11, the Song of Songs 2:3, 2:5, 7:8, 8:5 and Joel 1 :12 have been thought to be doubtful. because apple trees cannot be grown in the areas mentioned in the Bible. Some maintain that the apples in the Bible refer to apricots(Prunus armeniaca, Citrus medica L.) or golden oranges (Citrus sinensis L. Obsbeck) which is confusing. In the Revised Korean Version, 'Salgu(apricots)' appears eight times while ASV and KJV translate almond into 'Salgu'. So since translating a genuine apricot into 'Salgu' can be confusing, a great care should be taken in the translation into Korean. Some hold that as some papyri arround the year 1200 B.C. describes pomegranate, apple, olive and fig trees growing on the Nile delta, tappuah rightly refers to 'Sagwa(apple)' In the Korean Joint Version, Sagwa and Neungum are used together to refer to the same fruit, which should be avoided. It is desirable to use the same word for the same thing. Sagwa' showing up six times In the HeL.Ised Korean Version should all be replaced by 'Neungum' Dates symbolized peace and abundance were used for food in the raw or dried state, and were made into honey. Pomegranates can be eaten in the raw state and be used for sherbets and wine. Juice made of promegranates can be mixed with wine and drunk.

  • PDF

Smartphone Addiction Detection Based Emotion Detection Result Using Random Forest (랜덤 포레스트를 이용한 감정인식 결과를 바탕으로 스마트폰 중독군 검출)

  • Lee, Jin-Kyu;Kang, Hyeon-Woo;Kang, Hang-Bong
    • Journal of IKEEE
    • /
    • v.19 no.2
    • /
    • pp.237-243
    • /
    • 2015
  • Recently, eight out of ten people have smartphone in Korea. Also, many applications of smartphone have increased. So, smartphone addiction has become a social issue. Especially, many people in smartphone addiction can't control themselves. Sometimes they don't realize that they are smartphone addiction. Many studies, mostly surveys, have been conducted to diagnose smartphone addiction, e.g. S-measure. In this paper, we suggest how to detect smartphone addiction based on ECG and Eye Gaze. We measure the signals of ECG from the Shimmer and the signals of Eye Gaze from the smart eye when the subjects see the emotional video. In addition, we extract features from the S-transform of ECG. Using Eye Gaze signals(pupil diameter, Gaze distance, Eye blinking), we extract 12 features. The classifier is trained using Random Forest. The classifiers detect the smartphone addiction using the ECG and Eye Gaze signals. We compared the detection results with S-measure results that surveyed before test. It showed 87.89% accuracy in ECG and 60.25% accuracy in Eye Gaze.

Acupuncture Treatment in Feline Horner's Syndrome: Case Report (고양이 Horner's syndrome에 대한 침치료(針治療) 증예보고(症例報告))

  • Hsu, Chin-Yuan;Hsu, Chin-ling;Hsu, Chin-Hwang;Liao, Jim-Cai;Chueh, Hao-Jen;Cheng, Han-Wen;Jun, Hyeong-Kyou;Kim, Duck-Hwan
    • Journal of Veterinary Clinics
    • /
    • v.24 no.2
    • /
    • pp.214-217
    • /
    • 2007
  • A about 2-month- old, mixed female cat was referred to Yeon Chang Veterinaly Clinic in Taiwan. Because this patient was wandering cat, precise history was not blown. At first admission, miosis, ptosis and protrusion of the nictitating membrane was observed in the right sided eye, and also slight miosis was found in the left sided eye. The patient was diagnosed into feline HS. Oculo-AP and injection-AP with dexamethasone were applied to this patient. Oculo-AP at Shang Jiao regions of both eyes was done for 10 minutes. In addition, injection-AP with dexamethasone (0.2 ml/acupoint) at BL01-Jing Ming, BL02-Zan Zhu and ST01-Cheng Qi. After AP treatment, prolapse of the nictitating membrane was amazingly disappeared and pupil was dilatated at session 1. Ocular findings at session 2 (one day after session 1) were maintained with nearly normal state. Accordingly, the present patient was a case with feline HS that showed favorable therapeutic effect by AP treatment.

The Appropriateness in Yi Yik and Shin Hudam's Theories of Moral Emotion (이익(李瀷)과 신후담(愼後聃)의 사칠론(四七論)에서 중절(中節)의 의미)

  • Hong, Seong-min
    • Journal of Korean Philosophical Society
    • /
    • v.141
    • /
    • pp.313-342
    • /
    • 2017
  • This paper illuminates the philosophical meaning of appropriateness(中節) in Yi Yik(李瀷) and Shin Hudam(愼後聃)'s theories of moral emotion. According to this paper, there was a difficult problem in Toegye Yi Hwang (退溪 李滉)'s philosophy. That is, How we could regulate the relation between Four Beginnings(四端) and appropriate Seven Feelings(七情). Yi Yik tried to solve this problem by elucidating philosophical significances of appropriate Seven Feelings as it were, one hand, he approved the morality of appropriate Seven Feelings, and on the other hand, differentiated appropriate Seven Feelings from Four Beginnings. Thereby He achieved to explain this problem. His solution was dependent on the concept of 'impartial sympathic spectator' that he suggested. It is valuable that Yi Yik reexamined the ethical meaning of appropriateness. His pupil Shin Hudam, however, criticised Yi Yik's opinion and identified Four Beginnings with appropriate Seven Feelings. Shin Hudam deconstructed the conceptual scheme of moral emotion suggested by Yi Yik and regarded appropriate Seven Feelings as Four Beginnings. According to Shin Hudam, the concept of appropriate Seven Feelings designed by Yi Yik was very ambiguous, actually there was no any dividing line between Four Beginnings and appropriate Seven Feelings. Both are equally moral principle manifestation(理發)and moral public(公). Now old concept category of moral emotion(Sadan and Chiljeong) was disappeared and new concept category of moral emotion was appeared, that is public and private.

The Usefulness of Fluorescein Angiography and Alternative Tests for Assessment of Fundus Hemorrhage (안저 출혈 시 형광안저혈관조영술 및 대체 검사의 유용성)

  • Yeon, Je-Jin;Koo, Bon-Kyeong;Park, Sang-Ku
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.53 no.3
    • /
    • pp.266-276
    • /
    • 2021
  • Fundus hemorrhage refers to abnormalities in the retinal tissue and blood vessels. Therefore, when a hemorrhagic change in the fundus occurs, the ophthalmologist orders various ophthalmic tests to evaluate the degree of hemorrhage and determine the progress of the lesion before, during, and after treatment to accordingly establish a treatment plan. Currently, the most useful and universal fundus examination includes optical coherence tomography (OCT), fundus photography (FP), and fluorescein angiography (FAG). Existing fluorescein angiography test methods for establishing a treatment plan for severe fundus bleeding have limitations. The authors propose that peripheral pupil and the 5-quadrant method should be performed using ultra-wide-angle fluorescence fundus angiography (UWFFA). Using this method, it is possible to quickly determine the area to be described, avoid the radius of bleeding as much as possible, and provide the ophthalmologist with a range of damaged tissue and abnormal blood vessels. Nevertheless, there are cases in which ophthalmologists judge that fundus bleeding is so severe that ultra-wide-angle fluorescence fundus angiography is meaningless. In such cases, ophthalmic ultrasound and electroretinogram may be used in that order as alternative methods of examination. Therefore, some clinical situations require the use of ophthalmic ultrasound and electroretinogram and should be performed accurately.

A Study on Digital Healthcare Optometry System Using Optometry DB

  • Kim, Do-Yeon;Jung, Jin-Young;Kim, Yong-Man;Park, Koo-Rack
    • Journal of the Korea Society of Computer and Information
    • /
    • v.26 no.9
    • /
    • pp.155-166
    • /
    • 2021
  • Recently, digital health care technology is spreading and developing in various fields. Therefore, in this paper, we realized that the field to which digital healthcare technology is not applied is the field of optometry, and implemented a digital healthcare optometry system for precise lens manufacturing. A device called Phoroptor is used to manufacture the lens, and this device sets the lens by measuring the visual acuity of the person who requested the glasses. And when the person to be measured wears glasses, a device called a PD meter is used to align the pupil center and lens focus. However, there is a limit to the convenience of precise lens production and optometry due to the absence of a database and program that can accumulate and analyze the PD measurement error, inconvenience and error due to manual control of the Phoroptor, and optometric information. Therefore, in this paper, PD meter design for more accurate PD measurement, Phoroptor design and Phoroptor control application design for automatic Phoroptor control, and a database and analysis program that automatically set lenses using optometry information for each subject had been designed. Based on this, ultimately, a digital healthcare optometry system using an optometry database has been implemented.

The Tilting Vessels: Visualizing Anecdotes from the Life of Confucius (공자 고사의 시각화 - 기기도(欹器圖) 연구)

  • Song, Heekyung
    • (The)Study of the Eastern Classic
    • /
    • no.62
    • /
    • pp.263-289
    • /
    • 2016
  • Confucius, whose life coincided with the Warring States period of China, is one of the most respected sages in world history whose teachings and life produced countless disciples in China, Korea, and Japan. There are innumerable pictures, sculptures, and other artworks that portray memorable deeds of Confucius and interesting anecdotes that involve his pupils. One of the most popular subjects for these Confucian portrayals is the anecdote in which Confucius and his pupil, Zhi Ru, discover a tilting vessel at an ancestral shrine in the Lu dynasty and use it to understand the doctrine of the mean. The vessel becomes the basis for the famous Chinese expression, "the cautionary vessel beside one's seat," which is nowadays used to denote one's motto for life. Portraits of these tilting vessels can be divided between those showing the vessels only and others that show Confucius observing the vessels. The former serve as visual reminders, for rulers and policy makers, of the doctrine of the mean that is necessary to fair and righteous governance. The latter form part of the pictorial biography of Confucius with educational content and messages. Interestingly, portraits of Confucius observing or studying tilting vessels have been famous among members of the royal court and the literati, circulated either as single artworks or included in the folding screens of human portraits. Portrayals of other Confucian anecdotes are mostly found in albums that visualize the genealogy of the Way; in contrast, the portraits of Confucius and the tilting vessels were included in folding screens that were popular among the literati that enjoyed stylish works of art and antiques. The portraits of tilting vessels thus highlight the diverse functions and symbolic value of human portraits. This study classifies the portraits of tilting vessels into various forms, and analyzes the period-and objective-dependent changes and characteristics in these portraits. With its exploration of the diverse functions and aspects of portraits of Confucian anecdotes, this study will shed new light on how ancient artists reanimated the lives of great sages and how these artworks differ in their expressions and styles.

Autonomous Wheelchair System Using Gaze Recognition (시선 인식을 이용한 자율 주행 휠체어 시스템)

  • Kim, Tae-Ui;Lee, Sang-Yoon;Kwon, Kyung-Su;Park, Se-Hyun
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.14 no.4
    • /
    • pp.91-100
    • /
    • 2009
  • In this paper, we propose autonomous intelligent wheelchair system which recognize the commands using the gaze recognition and avoid the detected obstacles by sensing the distance through range sensors on the way to driving. The user's commands are recognized by the gaze recognizer which use a centroid of eye pupil and two reflection points extracted using a camera with infrared filter and two infrared LEDs. These are used to control the wheelchair through the user interface. Then wheelchair system detects the obstacles using 10 ultrasonic sensors and assists that it avoid collision with obstacles. The proposed intelligent wheelchair system consists of gaze recognizor, autonomous driving module, sensor control board and motor control board. The gaze recognizer cognize user's commands through user interface, then the wheelchair is controled by the motor control board using recognized commands. Thereafter obstacle information detected by ultrasonic sensors is transferred to the sensor control board, and this transferred to the autonomous driving module. In the autonomous driving module, the obstacles are detected. For generating commands to avoid these obstacles, there are transferred to the motor control board. The experimental results confirmed that the proposed system can improve the efficiency of obstacle avoidance and provide the convenient user interface to user.