• Title/Summary/Keyword: Puncture load

Search Result 5, Processing Time 0.016 seconds

Resistant Effects of Geosynthetics Against Puncture Loads as a Protective of HDPE (차수재(HDPE) 보호재로서 토목섬유의 천공(꿰뚫림)하중에 대한 저항효과)

  • 이광열;장삼식;구태곤
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.6
    • /
    • pp.11-17
    • /
    • 2004
  • This study focused on the protection effects of geosynthetics installed on HDPE to resist against puncture loads. The study was conducted by a model test with various types of puncture loads created by different shapes of tools. The puncture resistance of geosynthetics installed as a protective material on HDPE is varied depending on the sizes of geosynthetics and types of puncture loads. In this study, it was found that the protection effect far all kinds of geosynthetics when a truncated cylindrical shape of puncture tool is used is lower than others. Also, geocomposite has the most excellent protection effect against all types of puncture loads.

Prestrain-induced Reduction in Skin Tissue Puncture Force of Microneedle (초기변형률에 의한 미소바늘의 피부조직 관통력 감소)

  • Kim, Jonghun;Park, Sungmin;Nam, Gyungmok;Yoon, Sang-Hee
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.10
    • /
    • pp.851-856
    • /
    • 2016
  • Despite all the recent advances in biodegradable material-based microneedles, the bending and failure (especially buckling) of a biodegradable microneedle during skin tissue insertion remains a major technical hurdle for its large-scale commercialization. A reduction in skin tissue puncture force during microneedle insertion remains an essential issue in successfully developing a biodegradable microneedle. Here, we consider uniaxial and equibiaxial prestrains applied to a skin tissue as mechanophysical stimuli that can reduce the skin tissue puncture force, and investigate the effect of prestrain on the changes in skin tissue puncture force. For a porcine skin tissue similar to that of humans, the skin tissue puncture force of a flat-end microneedle is measured with a z-axis stage equipped with a load cell, which provides a force-time curve during microneedle insertion. The findings of this study lead to a quantitative characterization of the relationship between prestrain and the skin tissue puncture force.

Puncture and Cutting Resistance Characteristics of Shear Thickening Fluid Impregnated Kevlar Fabrics (전단농화유체가 함침된 Kevlar 직물의 방검 및 방침 특성)

  • Lee, Bok-Won;Kim, Il-Jin;Lee, Yeon-Gwan;Kim, Chun-Gon;Yoon, Byung-Il;Paik, Jong-Gyu
    • Composites Research
    • /
    • v.21 no.5
    • /
    • pp.23-30
    • /
    • 2008
  • Stab threats using sharp edged or pointed Instruments could be easily encountered by police officers or soldiers. In this study, the shear thickening fluids (STF) was impregnated into Kevlar fabrics to improve the stab protection and the resistance of STF impregnated Kevlar fabrics was experimentally investigated. The puncture and cut resistance were tested using a drop test machine withspike and knife indenters fabricated based on the National Institute of Justice (NIJ) standard. The STF was filled with spherical $SiO_2$ particles having an average diameter of 100nm, 300nm, and 500nm. The effect of particle size on puncture and cut resistance of STF impregnated Kevlar fabrics was also investigated. The measured impact load histories showed that STF impregnation into fabric leads to withstand higher peak loads than that of neat fabrics under spike test. The test results showed that Kevlar impregnated with STF exhibit remarkable improvements in puncture resistance while it is slightly influential on the cut resistance. Specifically, particle size is the one of the dominant factors controlling fabric resistance to puncture under spike impact test.

Prefabricated-HSPRCC panels for retrofitting of existing RC members-a pioneering study

  • Bedirhanoglu, Idris
    • Structural Engineering and Mechanics
    • /
    • v.56 no.1
    • /
    • pp.1-25
    • /
    • 2015
  • The main goal of this study was to develop a convenient strengthening technique for retrofitting of reinforced concrete members. For this purpose a new retrofitting material so-called prefabricated-HSPRCC (high performance steel plate reinforced cementitious composite) panel was developed by using high performance concrete and perforated steel plate. Prefabricated-HSPRCC composes advantages of steel and high performance concrete. The prefabricated-HSPRCC panels were either only bonded on the specimens using epoxy mortar or anchored to the specimen by steel bolts as well as bonding. Effect of different variations such as prefabricated-HSPRCC panel thicknesses, steel plate thicknesses, puncture orientation of perforated steel plate, existence of anchorage etc. were studied through a simple experimental work. The behaviour of the specimens under vertical point load was also studied by using simple mechanics. The retrofitted specimens were found to exhibit much better performance both in terms of strength and deformation capability. The anchorage application was found to positively affect this improved performance. Furthermore, as a result of the tests the best parameters of prefabricated-HSPRCC plate for improving strength and deformation capacities were determined.

Development of Extra High Voltage(400kN) Porcelain Insulator for Transmission Lines (765 kV용 400 kN 현수애자 개발)

  • 최인혁;최장현;이동일;최연규
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.8
    • /
    • pp.348-353
    • /
    • 2003
  • This paper was the research of high voltage suspension insulator (400 [kN]) including pottery stone, feldspar, clay and alumina of 17 [wt%]. The slurry was fabricated after ball milling mixed raw materials. Green compacts were made by the extrusion of jiggering method and were sintered at 1300[$^{\circ}C$] for 50 [min.] in the tunnel kiln. The sintered density was reached to 97% of theoretical density, and the bending strength was 1658 [k $g_{f}$/$\textrm{cm}^2$] and hardness and fracture toughness which was measured by ICL( indentation crack length ) method were 1658 (kgf/$\textrm{cm}^2$) and 27.5 [Gpa], respectively. In measurement of tana and insulation break voltage of 400 (kN) porcelain, tan$\delta$ took some numerical value between 17${\times}$10$_{-3}$ and 61${\times}$10$_{-3}$ and insulation break voltage value was 19.9$\pm$1.4 [㎸/mm]. The test was performed to research whether the shape of pin affect a overvoltage break load or not As a consequence, when a pin was designed a pin diameter 51 [mm] with the bottom form of two-step constructed with straight in the suspension insulator, Insulator showed overvoltage break load 52 [ton] of the highest value and reflected a fine characteristic in aged deterioration test which is one of the accelerated aging test. Also it could be confirmed a fine characteristic through performing the test that electrical property of insulator was established correctly in accordance with IEC 60383-1 standards.s.