• Title/Summary/Keyword: Pumping loss

Search Result 120, Processing Time 0.026 seconds

Optimal Design for the Rotor Overlap of a Supersonic Impulse Turbine to Improve the Performance (초음속 충동형 터빈 성능개선을 위한 동익 오버랩 최적설계)

  • Cho, Jong-Jae;Seo, Jong-Chul;Kim, Kui-Soon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.325-330
    • /
    • 2011
  • A rotor overlap technique was adapted to improve the performance of a axial turbine. The technique secured sufficient flow passage by additional height at the rotor tip and hub. especially in a supersonic turbine, the technique reduced the chance of chocking in the rotor passage, and made to be satisfied the design pressure ratio. However, the technique also made additional losses, like a pumping loss, expansion loss, etc. Therefore, a optimization technique was appled to maximize the improvement of the turbine performance. An approximate optimization method was used for the investigation to secure the computational efficiency. The design variables was shape factors of a rotor overlap. Results indicated that a significant improvement in turbine performance can be achieved through the optimization of the rotor overlap.

  • PDF

The Study on Drag Reduction Rates and Degradation Effects in Synthetic Polymer Solution with Surfactant Additives (계면활성제를 이용한 합성고분자 수용액의 마찰저항감소 및 퇴화 특성 향상 연구)

  • 이동민;김남진;윤석만;김종보
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.3
    • /
    • pp.194-199
    • /
    • 2001
  • The turbulent flow resistance of water solution with polymer is reduced as compared with that of pure water. This effects is named th drag reduction and offers the significant reduction of the pumping power and the energy consumption. But the intense shear forces and the high temperature experienced by the polymer solution when passing through the pipes cause the degradation a loss of drag reduction effectiveness. Especially, the degradation behavior is found to be strongly dependent on temperature. This mechanical and thermal degradation can be avoided by adding materials such as surfactant to the polymer solution, which enhance the bonding force between molecules. In the present study, Copolymer and SDS were utilized and they were mixed in 10 different mixture ratios, while total concentration was fixed as 100wppm. Degradation of Copolymer-SDS mixture solutions was investigated experimentally in closed loop at the temperature of $10^{\circ}C\; and\; 80^{\circ}C$ with various flow average velocities of 1.5 m/sec, 3.0m/sec, and 4.5m/sec. Degradation characteristics of polymer solution without surfactant show a radical loss of drag reduction effectiveness at high temperature. Degradation alleviation ability of surfactant is especially effective at high temperature. Consequently, this results show that the addition of surfactant to the polymer solution can control unfavorable degradation phenomena for high temperature systems.

  • PDF

Experimental Study of the Development of New Type Water Ejector (신형 수이젝터 개발을 위한 실험연구)

  • Choi, Hyun-Kue;Moon, Soo-Bum;Choe, Soon-Youl;Choi, Soon-Ho;Kim, Kyung-Kun
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.35-36
    • /
    • 2005
  • An ejector driven by a liquid is a fluid transfer equipment to be used under a poor suction condition, which means that there exists a possibility to occur a cavitation. It is a highly reliable device because it has no movable part in it, that is only a passive equipment. The ejector is an inevitably necessary one to overcome a poor pumping condition and to mix uniformly two fluids, however it has a low efficiency since it requires a pump for its operation. This study is for the development of a new-type liquid ejector with the application of a nozzle shape alteration, which maximize the suction performance of it. which provides the increased competition with the domestic industries. Also, the increased performance opens a new manufacturing method to use a commercial pipes for the production of an ejector, which is based on a trivial loss of a performance. However, this minor loss can be sufficiently compensated by the increased performance of a new-type ejector. Therefore, the developed ejector by this study can considerably reduce the manufacturing time and cost while its performance is largely increased.

  • PDF

Astigmatically compensated cw Ti:Sapphire laser pumped by $Ar^+$ laser (비점수차가 보상된 $Ar^+$ 레이저로 펌핑하는 cw Ti:Sapphire 레이저)

  • Yoon, Tai-Hyun;Kim, Gyu-Ug;Jo, Jae-Heung;Won, Jong-Wook
    • Proceedings of the KIEE Conference
    • /
    • 1990.07a
    • /
    • pp.451-454
    • /
    • 1990
  • Room temperature cw operations of a standing wave and a unidirectional Ti:Sapphire laser pumped by a $Ar^+$ laser have been demonstrated in the same pumping cavity configuration. Laser emission at 790 nm was excited with all-line $Ar^+$ laser pump for both cavities. The maximum output power was found to be 600 mW in the standing wave cavity and 210 mW in the ring cavity. Values of (83 ${\pm}$ 10) % for the internal quantum efficiency and (3.0 ${\pm}$ 0.5) % for the round-trip cavity loss for standing wave cavity are obtained from the thresholds and slope efficiencies measured with 2.4 and 11.2 % optput couplers. The measured cavity-loss value at 790 nm gives a meterial figure of merit (FOM) to be 146. Unidirectional operation of the ring Ti:Sapphire laser will be discussed.

  • PDF

Responsibility of Control System of Engine Intake Valve with Linear Electromagnetic Actuator

  • Nakpipat, Tawatchai;Kusaka, Akihiko;Ennoji, Hisayuki;Iijima, Toshio
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.291-295
    • /
    • 2004
  • New valve driving system to control for the best volumetric efficiency at each load of an internal combustion engine within one engine cycle has been developed. The system needs to reduce pumping loss that cause by throttle valve during the intake valve is opened. In this system the intake valve is driven by a linear DC electromagnetic actuator which is controlled by personal computer. The result is compared both installed and uninstalled actuator into the cylinder head. By both of experimental and numerical calculation, the responsibility of the valve driving system to the engine speed was examined

  • PDF

Numerical Analysis on the Heat Transfer Enhancement by Modified Lovour Fin (개량 루버핀에 의한 열전달 성능향상에 관한 연구)

  • Chung, Jae-Dong;Park, Byung-Kyu;Lee, Joon-Sik
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.408-413
    • /
    • 2001
  • Numerical analysis on the three-dimensional laminar flows (Re=1000) and heat transfer in a rectangular channel with punched longitudinal vortex generator have been conducted to explore the heat transfer enhancement and the combined effect of the angle of attack ${\alpha}$ and the lovour angle ${\beta}$. Rectangular winglets have been used as vortex generators. Velocity and temperature fields and spanwise averaged Nu and friction factor were presented. Enhancement of heat transfer and flow loss penalty are evidenced. The results show performance characteristics allowing a reduction in heat transfer surface area of 62% for fixed heat duty and for fixed pumping power compared with that of channel flow without vortex generator. However, adding lovour angle to the vortex generator shows no positive effect on the heat transfer enhancement.

  • PDF

Development of Leakage-free Automatic Discharge Connect in a Submersible Pump. (수중펌프의 Leakage-free 자동탈착장치 개발)

  • Choi, Young-Seok;Lee, Kyoung-Yong;Lee, Chang-Han;Lee, Jong-Hun
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.63-68
    • /
    • 2002
  • ADC(Automatic Discharge Connector) is commonly used for the easy maintenance of the submersible pumps. However, the small gap between the flange of the base plate and that of the pipe due to the head rise, the flow momentum change and the mis-installation makes leakage flow that may be a great loss to the pumping system. In this study, the performance degradation was predicted with the simple leakage flow model through the gap. The newly developed ADC was tested and the leakage performance was compared with the old one and also no-leakage piping system. The newly developed ADC reduced the leakage flow in a satisfactory way in comparison with the old model.

  • PDF

Study on the erosion-corrosion damages of pump impeller (워터펌트 내에 있는 임펠러의 침식.부식에 관한 연구)

  • Kim, Jae-Wook;Lim, Hee-Chang;Lim, Uh-Joh
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.102-107
    • /
    • 2007
  • The steel impeller placed in a water pump has been studied with the aim to understand corrosion phenomena on the surface responsible for reducing the pumping efficiency of water inside cooling system. This preliminary experiment includes a period (around 1 month) observation with a powered microscope and weight measurements. The experiments are carried out at different conditions of water and mixtures of water and coolants, based on the water contents of 25%, 50%, 75%, and 100% water (pure tap water). From the visual results of microscopy, most of the steel surface is fitted and clear rusty or corrosion phenomena are noticeable as time goes. In addition, the weight loss of the sample specimen submerged in the water is linearly increased, whereas those in the mixtures of water initially gain weight and become almost constant.

  • PDF

The study on the friction characteristics of spherical hydrostatic bearing for hydraulic piston motor (유압모터 구면 정압베어링의 마찰특성에 관한 연구)

  • 함영복;최영호;김성동
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.647-650
    • /
    • 2001
  • In case of bent axis type axial piston hydraulic pump or motor, hydrostatic bearing used to achieve the lubrication effect on the mechanical sliding contact areas between the following pairs ; piston shoe and swash plate, valve plate and cylinder block, piston and cylinder block, etc. In this research, we designed two pairs of spherical ball joint in witch connecting rod piston end. The one is not hydrostatic bearing, the other is designed with spherical hydrostatic bearing in point of view minimum pumping power loss. By varying supply pressure on the piston, we can know that it is possible to reduce the friction torque by using hydrostatic bearing designed one. Finally, by comparing the results of driving torque between the two models, it was verified that the spherical hydrostatic bearing is well designed.

  • PDF

Simultaneous Monitoring of KVN 4 Bands toward Evolved Stars

  • Cho, Se-Hyung
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.112.2-112.2
    • /
    • 2014
  • We propose simultaneous monitoring observations of 22 GHz $H_2O$ and 43/86/129 GHz SiO masers toward ~15 evolved stars in order to investigate spatial structure and dynamical effect from SiO to $H_2O$ maser regions including mass-loss process and development of asymmetry in circumstellar envelopes. We also aim at investigating mutual association and difference between SiO and $H_2O$ masers for establishing SiO and $H_2O$ maser models coupled to hydrodynamical model of circumstellar envelope. In addition, the correlation and difference of SiO maser properties among J=1-0, J=2-1, and J=3-2 transition masers are traced according to different type of stars for constraining SiO pumping models. These scientific goals and target sources were determined based on KVN single dish and VLBI feasibility test observations at 4 bands. As a total observing time of every 2 month monitoring, about 90 and 360 hours (in average per year) are required for single dish and VLBI observations, respectively. From the 2014B observing season, these monitoring observations will be derived as one of KVN key science programs.

  • PDF