• Title/Summary/Keyword: Pumping Rate

Search Result 377, Processing Time 0.025 seconds

A study on the estimation of river water intake using the operating time of the pumping station (양수장의 가동시간을 이용한 하천수 취수량 산정방안 연구)

  • Baek, Jongseok;Kim, Chiyoung;Cha, Jun-Ho;Song, Jaehyun
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.2
    • /
    • pp.89-96
    • /
    • 2020
  • Water management agencies under the Ministry of Environment produce and accumulate qualified basic data for major rivers. However, the integrated management of the river water has been weak since the artificial water circulation process, such as the intaking and drainage of agricultural water, has not been examined in the basin, which includes many agricultural land. In this study, a study was conducted on how the power usage method (operating time method) based on the running time can be applied and improved among indirect flow rate measurement methods used to investigate flow rates collected by the riverside for agricultural water purposes, and thus the resultant data of high reliability can be obtained at low cost. The operation time method is suitable for small-scale water pumping stations where it is difficult to secure real-time power supply data. The reliability of the data was verified through the correlation analysis with the actual flow rate, and it was found that the flow rate calculated by the operation time method reflecting the level of the stream to which the inlet of the pumping station is connected can be reasonably matched with the actual flow rate. In addition, it was confirmed that the investment cost at the time of initial installation of the facility was highly efficient by generating qualified flow data at low cost through comparison with direct flow rate measurement methods. If flow data is secured by applying the operation time method to large and small water farms located along the riverside, it is expected that more quantitative and integrated stream water management will be possible.

Relationship between Energy Consumption and Operational Variables at Wastewater Treatment Plant (상관분석 및 의사결정나무분석을 통한 하수처리시설의 에너지 소비량과 운영인자의 관계 분석)

  • Jung, Yong-Jun;Kim, Ye-Jin
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.3
    • /
    • pp.253-260
    • /
    • 2016
  • To reduce energy consumption in wastewater treatment plants (WWTPs), renewable energy applications such as small hydropower, solar energy, and wind energy are popular. However, it should be noticed that energy originated from operation of wastewater treatment process can be reduced through optimized operation based on analysis of factors affecting energy. In this research, the relationship to the various operational variables and influent factors was explored using correlation analysis and decision tree algorithm. Due to the non-linear characteristics of the process, it was difficult to find clear linear patterns through correlation analysis. However, decision tree algorithm showed its usefulness in uncovering hidden patterns that consume energy. As operational factors, influent flowrate, the amount of aeration, nitrate recycling pumping rate, and sludge wasting pumping rate were selected as important factors. For environmental factors associated with influent compositions and removal rate, BOD and T-N removal rate were selected as significant factors.

Artificial Injection to Control Saltwater Intrusion in Groundwater-Numerical Study on a Vertical Cross Section (지하수 해수쐐기 제어를 위한 인공주입-연직 2차원 단면 수치실험)

  • Hong, Sung-Hoon;Shi, Lei;Cui, Lei;Park, Nam-Sik
    • The Journal of Engineering Geology
    • /
    • v.19 no.2
    • /
    • pp.131-138
    • /
    • 2009
  • A simulation-optimization model is developed for development of groundwater and control of a saltwater wedge for protecting over-exploiting freshwater pumping wells. To achieve the goal an objective function is developed for three types of wells: freshwater pumping, freshwater injection and saltwater pumping. Integrity of groundwater environment is accounted for by including three indices. Illustrative cross-sectional examples show that both types of barriers can protect freshwater pumping wells from saltwater intrusion. A barrier well operating at the same rate located anywhere within a certain reach can protect a pumping well. However, the location of the reach appears to contradict the common practice of barrier placements. Consideration of the groundwater environment yields a unique optimal location for barrier wells.

The KSTAR Vacuum Pumping and Fueling System Upgrade

  • Lim, J.Y.;Chung, K.H.;Cho, S.Y.;Lee, S.K.;Shin, Y.H.;Hong, S.S.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.39-39
    • /
    • 1999
  • The KSTAR (Korea Superconducting Tokamak Advanced Research) tokamak is a nuclear fusion experimental device for a long pulse/steady-state plasma operation, adopting fully superconducting magnets. In accordance with completion of the basic design of the torus vacuum vessel and the enclosing cryostat, the vacuum pumping and gas fueling basic design has been developed to fulfil the physics requirements. The ultra-high vacuum pumping and sophisticated gas fueling system of the machine is essential to achieve such roles for optimized plasma performance and operation. Recently the vacuum exhaust system using dedicated pumping ports for the vacuum vessel and cryostat has been modified to meet more reliable and successful performance of the KSTAR[Fig. 1].In order to achieve the required base pressure of 5 x 10-9 torr, the total impurity load to the vessel internal is limited to ~5 x 10-5 torr-1/x, while the cryostat base pressure is kept as ~5 x 105 torr to mitigate the thermal load applied to the superconducting magnets. Each KSTAR fueling system will be separately capable of fueling gas at a rate of 50 torr-1/x, consistent with the given pumping throughput. In order to initiate a plasma discharge in KSTAR, the vacuum vessel is filled to a gas pressure of few 10-6 to few 10-4 torr, and additional gas injection is required to maintain and increase the plasma density during the course of the discharge period.

  • PDF

Novel Fabrication and Testing of a Bubble-Powered Micropump (새로운 기포동력 마이크로펌프 제작 및 실험)

  • Jung, Jung-Yeul;Kwak, Ho-Young
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1196-1200
    • /
    • 2004
  • Micropump is very useful component in micro/nano fluidics and bioMEMS applications. In this study, a bubble-powered micropump was fabricated and tested. The micropump consists of two-parallel micro line heaters, a pair of nozzle-diffuser flow controller and a 1 mm in diameter, 400 ${\mu}m$ in depth pumping chamber. The two-parallel micro line heaters with 20 ${\mu}m-width$ and 200 ${\mu}m-length$ were fabricated to be embedded in the silicon dioxide layer of a wafer which serves as a base plate for the micropump. The pumping chamber, the pair of nozzle-diffuser unit and microchannels including the liquid inlet and outlet port were fabricated by etching through another silicon wafer. A glass wafer (thickness of $525{\pm}15$ ${\mu}m$) having two holes of inlet and outlet ports of liquid serve as upper plate of the pump. Finally the silicon wafer of the base plate, the silicon wafer of pumping chamber and the glass wafer were aligned and bonded (Si-Si bonding and anodic bonding). A sequential photograph of bubble nucleation, growth and collapse was visualized by CCD camera. Clearly liquid flow through the nozzle during the period of bubble growth and slight back flow of liquid at the end of collapsing period can be seen. The mass flow rate was found to be dependent on the duty ratio and the operation frequency. As duty ratio increases, flow rate decreases gradually when the duty ratio exceeds 60%. Also as the operation frequency increases, the flow rate of the micropump decreases slightly.

  • PDF

Performance of Airlift Pumps for Water Circulation and Aeration (물 순환 및 에어레이션용 에어리프트 펌프의 성능)

  • OH Se-Kyung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.25 no.6
    • /
    • pp.529-537
    • /
    • 1992
  • Airlift pumps were tested to evaluate their pumping and aeration capacities. The pumps were 34.5 inch long made of 2, 3, 4 and 6 inch nominal diameter PVC pipes. An one hp air blower was used to supply the air. The air-flow rate was measured by an anemometer type air-flow meter and air pressure was level changes in a water tank from which water was pumped. Aeration by the pumps was tested by the standard aeration test method with the center of pump outlet positioned 3 inches above water surface. Oxygen concentrations in water were measured to determine aeration rate. As pumping head increased by water level draw-down in the tank water flow decreased while air flow increased. The reduction rate of water flow was higher with 4 and 6-inch pumps. Small pumps showed very minor changes in the reduction. Aeration rates were similar among 3, 4, and 6 inch pumps. With one hp air blower 6-inch pump at the minimum pumping head achieved the best performance in terms of water circulation.

  • PDF

Simulation of $H_2O/LiBr$ Triple Effect Absorption Systems with a Modified Reverse Flow

  • Jo, Young-Kyong;Kim, Jin-Kyeong;Kang, Yang-Tae
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.15 no.3
    • /
    • pp.114-121
    • /
    • 2007
  • In this study, a modified reverse flow type, one of the triple effect absorption cycles, is studied for performance improvement. The cycle simulation is carried out by using EES(Engineering Equation Solver) program for the working fluid of $H_2O/LiBr$ solution. The split-ratios of solution flow rate, UA of each component, pumping mass flow rate of solution are considered as key parameters. The results show that the optimal SRH (split ratio of high side) and SRL (split ratio of low side) values are 0.596 and 0.521, respectively. Under these conditions, the COP is maximized to 2.1. The optimal pumping mass flow rate is selected as 3 kg/s and the corresponding UAEV A is 121 kW/K in the present system. The present simulation results are compared to the other literature results from Kaita's (2002) and Cho's (1998) triple effect absorption systems. The present system has a lower solution temperature and a higher COP than the Kaita's modified reverse flow, and it also gives a higher COP than the Cho's parallel flow by adjusting split ratios.

Effect of Polymer Additives on Drag Reduction for a Plate Type Heat Exchanger in OTEC Applications (고분자 첨가제에 의한 OTEC용 판형 열교환기의 마찰저항감소 효과 연구)

  • Kim, N.S.;Yoon, S.M.;Seo, T.B.;Kim, C.B.
    • Solar Energy
    • /
    • v.19 no.2
    • /
    • pp.37-44
    • /
    • 1999
  • Experimental investigation has been carried out to determine drag reducing effects of polymer additives for a plate type heat exchanger(evaporator or condenser) in OTEC power plant applications, where the pressure drop in the heat exchangers takes up $70{\sim}80%$ of the total pumping power in the existing system. The rate of drag reduction was investigated with various polymer concentrations and mass flow rates. Experiments were undertaken for a test section in Alfa-Laval plate heat exchanger utilizing Poly Ethylene Oxide(Mw $5{\times}10^6$) as polymer additives. Concentrations of polymer additives were 5, 10, 20, 30, 40, 50, 100, 200, 400 wppm at $25^{\circ}C$ and mass flow rates were 0.6kg/s, 0.7kg/s, 0.8kg/s and 0.9kg/s in normal operating ranges for a 15kW Alfa-Laval plate heat exchanger. The maximum effects of drag reductions were found at approximately 0.7kg/s of mass flow rate. The results show that there exists the optimum mass flow rate for the plate heat exchanger to obtain maximum drag reductions. Drag reduction of 20% means considerable savings in pumping power for a large size of OTEC plant.

  • PDF

Evaluation of stream depletion due to nearby groundwater pumping using Baalousha analytical solution (Baalousha 해석해를 이용한 하천 주변 지하수 양수로 인한 하천수 감소 분석)

  • Lee, Jeongwoo;Kim, Nam Won;Chung, Il-Moon;Hong, Sung Hun
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.2
    • /
    • pp.99-107
    • /
    • 2018
  • This study was to evaluate the stream depletion due to groundwater pumping from 17 wells near the Anseongcheon upper stream using the Baalousha's analytical solution (2012) which directly considers stream width and streambed hydraulic conductivity. The input hydraulic values of aquifer and streambed were obtained from the pumping tests and seepage experiments. The estimated streamflow depletion rates divided by pumping rate (dimensionless stream depletion) showed a range from 0.23 to 0.89 for 5 year pumping. In particular, the results revealed that the groundwater pumping has insignificant effects on streamflow when the stream depletion factor (SDF) is higher than 1,000 with values of dimensionless stream depletion lower than 0.4. A more simple Hunt's solution (1999) also applied to the same wells, and the results showed that the difference between the dimensionless stream depletions calculated by using both solutions could be negligible. From the comparison of the Baalousha's solution (2012) with the Hunt's solution (1999) with total 3,000 cases of simulations with combinations of various aquifer and stream properties, the stream-well distance should be more longer than stream width for reducing the discrepancy between both solutions.

Transistorized counting-rate meter (트랜지스터 계수율계)

  • 정만영;박계영
    • 전기의세계
    • /
    • v.15 no.4
    • /
    • pp.18-21
    • /
    • 1966
  • A transistorized counting-rate meter was designed by substituting one of diodes in the ordinary diode pumping circuit by the Darling's constant current source. Its circuit is so simple and stable that it is proper to use as a part of portable radiation detectors. Maximum readable counting rate is well above 100 kc/s and the linearity is very good. Output deviations due to the variations of embient temperatures are less than 5% in the temperatures from 20.deg. C to 40.deg. C.

  • PDF