• Title/Summary/Keyword: Pumped-Storage hydro plant

Search Result 11, Processing Time 0.028 seconds

A Study on the Strategic Competition Model of Pumped Storage Plant (양수발전기의 전략적 시장참여에 대한 해석 모형 연구)

  • Lee, Kwang-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.10
    • /
    • pp.1738-1743
    • /
    • 2007
  • This paper addresses the bidding strategies of a pumped-storage hydro plant in an electricity market. Competitive bidding of pumping and generating of a pumped-storage plant is formulated in a game theoretic problem in accordance with the three different ownership of scheduling; Market Operator(MO), generating company(Genco), and combined type of MO and Genco. Optimal conditions for Nash Equilibrium are derived in the form of market prices during the scheduling periods. Simulation results show the different ownership models produce different schedules of pumping and generating, which correspond to the objective of the scheduling owner of a pumped-storage hydro plant.

A Study on the Weekly Operation planning of pumped Hydrostorage plant Considering Unit Commitment (기동정지계획을 고려한 제수발전소의 주간 운용에 관한 연구)

  • 송길영;홍상은;김영태
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.5
    • /
    • pp.319-327
    • /
    • 1987
  • This paper presents a dynamic programming sucdessive approximation algorithm for scheduling pumped storage hydro plants and shows how this method can be coordinated with the commitment of the thermal units of the system. The general object of operation of pumped hydrostorage plants is the minimization of the overall production cost and the maximization of generation reserves. The basic procedure used to obtain a combined pumped storage-unit commitment schedule is to execute the pumped storage scheduler and unit commitment scheduler iteratively. A combined DPSA algorithm has been presented to coordinate the scheduling of the pumped storage with the scheduling of the thermal units.

  • PDF

Development of New Effectiveness Assessment Indices of Pumped Storage Power Plant (양수발전기의 신 효용성 평가 지수 개발)

  • Lee, Sung-Hun;Choi, Jae-Seok;Cha, Jun-Min;Kim, Daniel
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.7
    • /
    • pp.867-874
    • /
    • 2014
  • The pumped storage power plants have excellent load following characteristics. It can also be committed quickly for synchronous reserve when it is in the generating mode because it can readily increase its generating power and, consequently, increases the overall system reliability. There are strong incentives for standing the system reliability. Additionally, $CO_2$ emission can be typically impacted due to operation of pumped generators. The increase or decrease of $CO_2$ depends on the generation mix. This paper proposes evaluation of reliability, economy and environment of power system considering pumped generator. This paper describes three case studies of the reliability and economy and environment according to capacity factor and storage capacity of pumped generators. The probabilistic production simulation model is used in this paper. The practicality and effectiveness of the proposed approach are demonstrated by simulation studies for a real size power system model on the $5^{th}$ power plan in Korea.

The Best Generation Mix considering CO2 Air Pollution Constraint ($CO_2$ 배출량제약을 고려한 최적전원구성)

  • Lee, Sang-Sik;Tran, TrungTinh;Kwon, Jung-Ji;Choi, Jae-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.149-151
    • /
    • 2005
  • A new approach considering CO2 air pollution constraints in the long-term generation mix is proposed under uncertain circumstances. A characteristic feature of the presented approach in this paper is what effects give the air pollution constraints in long term best generation mix. Best generation mix problem is formulated by linear programming with fuel and construction cost minimization with load growth, reliability (reserve margin rate) and air pollutionconstraints. The proposed method accommodates the operation of pumped-storage generator. It was assumed in this study that the construction planning of the hydro power plants is given separately from the other generation plans. The effectiveness of the proposed approach is demonstrated by applying to the best generation mix problem of KEPCO-system, which contains nuclear, coal, LNG, oil and pumped-storage hydro plant multi-years.

  • PDF

The Analysis and Improvement of Generator Protection System in Pumped Storage Hydro plant (양수발전기 보호 분석 및 개선)

  • Kim, Chun-Kyum
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.211-213
    • /
    • 2011
  • 통상 발전원으로서의 역할만을 담당하는 일반 화력발전기와는 달리 양수발전기는 발전원으로서의 역할뿐 아니라 계통운영의 경제성과 운영방향에 따라 부하로서의 역할을 수행한다. 이때는 동기기로서 조상기 혹은 전동부하가 되며 이로 인하여 일반 화력발전기와는 다르게 양수운전등 부하로서의 역할을 위한 또 다른 보호시스템을 적용하고 있다. 대용량 발전기와 전동부하로서의 역할을 겸용함으로써 필연적으로 나타나는 화력발전기와의 보호방식 차이를 비교 분석하고 보다 안정된 설비운전을 위한 보호시스템 적용에 대해 논하고자한다.

  • PDF

A Study on the Development of Battery Energy Storage System (전지이용 전력저장장치 기술개발)

  • Hwang, Yong-Ha;Lee, Keun-Seob
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.905-907
    • /
    • 1993
  • Demand for electricity is increasing annually. Especially, the daytime demand grawth shows higher than any other time period. So the big difference between maximum and minimum electrical demand becomes another important problem to be solved. The Battery Energy Storage System is chosen as one of the solutions among the sevral methods. The purpose of utilization of Battery Energy Storage System is to improve the daily load factor. Also, Battery Energy Storage System may be used for the load levelling or the load shifting as well as the spinning reserve. Up to now, only the pumped hydro power plant system has been operated on the commercial basis, but this system has so many constraints such as site, environmental effects, construction period, ect. Being considered current electrical power situation the development of electric storage system is in need latly. Among the various electric storage systems, Battery Energy System is chosen with the top priority because it has sevral merits to cover such as the short construction period, the demand site installation, and the food environmental characteristics.

  • PDF

Production Costing Model Including Hydroelectric Plants in Long-range Generation Expansion Planning (장기전원계획에 있어서 수력운전을 고려한 운전비용 계산모형)

  • 신형섭;박영문
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.2
    • /
    • pp.73-79
    • /
    • 1987
  • This paper describes a new algorithm to evaluate the production cost for a generation system including energy-limited hydroelectric plants. The algorithm is based upon the analytical production costing model developed under the assumption of Gaussian probabilistic distribution of random load fluctuations and plant outages. Hydro operation and pumped storage operation have been dealt with in the previous papers using the concept of peak-shaving operation. In this paper, the hydro problem is solved by using a new version of the gradient projection method that treats the upper / lower bounds of variables saparately and uses a specified initial active constraint set. Accuracy and validity of the algorithm are demonstrated by comparing the result with that of the peak-shaving model.

  • PDF

Spatial and Temporal Distribution Characteristics of Zooplankton Appeared on Early Construction of Pumped Storage Power Plant Dam (양수발전댐의 건설 초기에 발생한 동물플랑크톤군집의 시.공간적인 분포특성)

  • Lee, Jaeyong;Jung, Sungmin;Chang, Kun;Kim, Bomchul
    • Korean Journal of Ecology and Environment
    • /
    • v.47 no.spc
    • /
    • pp.57-65
    • /
    • 2014
  • Spatial and temporal distributions of zooplankton were measured in an oligotrophic pumped storage-type hydroelectric reservoir which was composed of two reservoirs exchanging water daily, with water going up at night and going down during the day. Repetitive diel disturbance of the water column can be a unique feature of this reservoir system. Chl-${\alpha}$ concentration was highest in the early winter season. Phytoplankton density was lower in summer monsoon due to high flushing rate on rainy days. The zooplankton density was higher in the smaller upper reservoir possibly due to lower fish density in the upper reservoir. In the seasonal variation a time gap was observed between the phytoplankton bloom and the zooplankton bloom (particularly a rotifer, Keratella cochlearis). It is likely to that Keratella production is partially supported by heterotrophic food sources than phytoplankton. The dominance of a mixotrophic dinoflagellate (Peridinium bipes f. ocultatum) might have complicated the trophic relationship between phytoplankton and zooplankton. Our results provide some ecological information of zooplankton community in a highly disturbed alpine reservoir ecosystem relying on mostly allochthonous organic matter.

Seepage Analysis of Rock -fill Dam Subjected to Water Level Fluctuation (수위가 변동하는 휠댐의 안정성 해석(I))

  • 이대수
    • Geotechnical Engineering
    • /
    • v.12 no.6
    • /
    • pp.65-78
    • /
    • 1996
  • The Chungpyung Dam is a 16 yearn old rock-fill dam for a Pumped storage hydro-Power plant, located in the middle of the Korean Peninsula. Since the dam is subjected to the daily water level fluctuation, such as rapid drawdown and refill, thus inducing a structural impact on the behavior of dam body, it draws attention of many engineering concerns. Traditionally, steady-state analysis was employed to investigate the seepage in the dam body, but in this study the seepage analysis was numerically performed by 2-D FEM thansient analysis. As a boundary condition for an analysis, the water level fluctuation was incorporated to simulate the daily change. As a res41t, the various seepage phenomena such as hydraulic gradient, seepage vector, and pore water pressure distribution were quantified at the corresponding time of interest as the water level rises and recedes. The seepage flux was also estimated and compared with the measured data which were both acceptable considering design criteria. The result proves that there is no sign of hazardous sources contributing to the possibility of piping, internal erosion and excess leakage through the dam body.

  • PDF