• 제목/요약/키워드: Pump performance

검색결과 1,912건 처리시간 0.028초

설비공학 분야의 최근 연구 동향 : 2010년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2010)

  • 한화택;이대영;김서영;최종민;김수민;권영철;백용규
    • 설비공학논문집
    • /
    • 제23권6호
    • /
    • pp.449-469
    • /
    • 2011
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering during 2010. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery, and new and renewable energy. Various topics were presented in the field of general thermal and fluid flow. Research issues mainly focused on the thermal reliability of axial fan and compressor in the field of fluid machinery. Studies on the design of ground source heat pump systems and solar chemical reactors were executed in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer in thermoelectric cooling/power generation systems, combined heat and power systems, carbon nano fluid with PVP, channel filled with metal foam and smoke ventilation in a rescue station of a railroad tunnel. Also the studies on flow boiling of R123/oil mixture in a plain tube bundle and R410A charge amount in an air cooled mini-channel condenser were reported. In the area of industrial heat exchangers, researches on plate heat exchanger, shell and tube heat exchanger, enthalpy exchanger, micro channel PCHE were performed. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer in thermoelectric cooling/power generation systems, combined heat and power systems, carbon nano fluid with PVP, channel filled with metal foam and smoke ventilation in a rescue station of a railroad tunnel. Also the studies on flow boiling of R123/oil mixture in a plain tube bundle and R410A charge amount in an air cooled mini-channel condenser were reported. In the area of industrial heat exchangers, researches on plate heat exchanger, shell and tube heat exchanger, enthalpy exchanger, micro channel PCHE were performed. (3) Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and CO2 were studied. Performance improvement of refrigeration systems are tried applying various ideas of refrigerant subcooling, dual evaporator with hot gas bypass control and feedforward control. The hybrid solar systems combining the solar collection devices with absorption chillers or compression heat pumps are simulated and studied experimentally as well to improve the understanding and the feasibility for actual applications. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. Various studies on heating and cooling systems, HVAC facilities, indoor air environments and energy resources were carried to improve the maintenance and management of building service equipments. In the field of heating and cooling systems, papers on a transformer cooling system, a combined heat and power, a slab thermal storage and a heat pump were reported. In the field of HVAC facilities, papers on a cooling load, an ondol and a drying were presented. Also, studies on HVAC systems using unutilized indoor air environments and energy resources such as air curtains, bioviolence, cleanrooms, ventilation, district heating, landfill gas were studied. (5) In the field of architectural environment and energy, studies of various purposes were conducted such as indoor environment, building energy, renewable energy and green building. In particular, renewable energy and building energy-related researches have mainly been studied reflecting the global interest. In addition, many researches which related the domestic green building certification of school building were performed to improve the indoor environment of school.

지열 냉방시스템을 이용한 분만돈사의 냉방효과 분석 (Evaluation on Cooling Effects of Geothermal Heat Pump System in Farrowing House)

  • 최희철;송준익;나재천;김민지;방한태;강환구;박성복;채현석;서옥석;유영선;김태원;박재홍
    • 한국축산시설환경학회지
    • /
    • 제16권2호
    • /
    • pp.99-108
    • /
    • 2010
  • 지열냉방시스템을 분만돈사에 적용하여 냉방효과 및 분만돈과 자돈의 생산성을 조사하였다. 처리구는 지열냉방돈사와 관행돈사로 2개로 나누였으며, 돈사당 각각 모돈 48두씩를 수용하여 하절기 4주간 시험을 실시하였다. 시험결과, 외부기온이 $33.0^{\circ}C$ 이상으로 더운 날에는 냉방을 위한 지하수 순환량이 많이 소요되어 최고기온과 지하수 순환량이 아주 밀접한 정의 상관관계가 있는 것으로 나타났다. 지열냉방 돈사의 온 습도 변화의 경우 최고기온은 관행돈사에 비하여 낮게 유지되고, 최저기온도 많이 떨어지지 않아 일교차가 훨씬 적었다. 미세먼지 입자가 상대적으로 큰 PM 10은 지열냉방돈사가 관행돈사에 비하여 최고 61.4% (111.1 vs 42.9) 까지 감소되었다. 그러나 작은 입자의 분진은 오히려 지열 냉방구에서 약간 높은 경향이었다. 암모니아가스 배출량의 경우 지열냉방돈사는 관행돈사에 비하여 유의하게 (p<0.05) 감소하였다. 총 3회에 걸쳐 측정된 임신돈의 호흡수는 지열냉방돈사에서 유의적으로 (p<0.05) 감소하였고, 에피네프린과 노르에피네프린 호르몬의 경우에 지열냉방돈사에서 감소하는 경향을 보였다. 이유시 체중은 지열 냉방돈사가 관행돈사에 비하여 유의적으로 (p<0.05) 증가하였으며, 여름철 모돈의 사료 섭취량은 관행돈사에서 유의적으로(p<0.05) 감소하였다. 따라서 지열냉방시스템은 여름철 분만사의 온 습도를 낮게 유지시킬 수 있을 뿐만 아니라 분진, 암모니아 가스 발생량 빛 모돈의 호흡수 감소에 영향을 주어 모돈과 포유자돈의 생산성을 개선시킬 수 있다.

설비공학 분야의 최근 연구 동향: 2008년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2008)

  • 한화택;최창호;이대영;김서영;권용일;최종민
    • 설비공학논문집
    • /
    • 제21권12호
    • /
    • pp.715-732
    • /
    • 2009
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2008. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends in thermal and fluid engineering have been surveyed in the categories of general fluid flow, fluid machinery and piping, new and renewable energy, and fire. Well-developed CFD technologies were widely applied in developing facilities and their systems. New research topics include fire, fuel cell, and solar energy. Research was mainly focused on flow distribution and optimization in the fields of fluid machinery and piping. Topics related to the development of fans and compressors had been popular, but were no longer investigated widely. Research papers on micro heat exchangers using nanofluids and micro pumps were also not presented during this period. There were some studies on thermal reliability and performance in the fields of new and renewable energy. Numerical simulations of smoke ventilation and the spread of fire were the main topics in the field of fire. (2) Research works on heat transfer presented in 2008 have been reviewed in the categories of heat transfer characteristics, industrial heat exchangers, and ground heat exchangers. Research on heat transfer characteristics included thermal transport in cryogenic vessels, dish solar collectors, radiative thermal reflectors, variable conductance heat pipes, and flow condensation and evaporation of refrigerants. In the area of industrial heat exchangers, examined are research on micro-channel plate heat exchangers, liquid cooled cold plates, fin-tube heat exchangers, and frost behavior of heat exchanger fins. Measurements on ground thermal conductivity and on the thermal diffusion characteristics of ground heat exchangers were reported. (3) In the field of refrigeration, many studies were presented on simultaneous heating and cooling heat pump systems. Switching between various operation modes and optimizing the refrigerant charge were considered in this research. Studies of heat pump systems using unutilized energy sources such as sewage water and river water were reported. Evaporative cooling was studied both theoretically and experimentally as a potential alternative to the conventional methods. (4) Research papers on building facilities have been reviewed and divided into studies on heat and cold sources, air conditioning and air cleaning, ventilation, automatic control of heat sources with piping systems, and sound reduction in hydraulic turbine dynamo rooms. In particular, considered were efficient and effective uses of energy resulting in reduced environmental pollution and operating costs. (5) In the field of building environments, many studies focused on health and comfort. Ventilation. system performance was considered to be important in improving indoor air conditions. Due to high oil prices, various tests were planned to examine building energy consumption and to cut life cycle costs.

상수도 시스템 지진 신뢰성의 합리적 평가를 위한 적정 지반운동예측식 결정 (Determination of proper ground motion prediction equation for reasonable evaluation of the seismic reliability in the water supply systems)

  • 최정욱;강두선;정동휘;이찬욱;유도근;조성배
    • 한국수자원학회논문집
    • /
    • 제53권9호
    • /
    • pp.661-670
    • /
    • 2020
  • 최근 지진재해의 규모가 점차 증대됨에 따라 세계적으로 개별 시설물에 대한 내진성능평가와 관련한 연구가 다수 진행되고 있다. 상수도 시스템은 타 기반 시설에 비해 설치범위가 광범위하고 그 구성요소가 다양해 고려할 것이 많아 지진에 대한 안정성을 정확하고 효과적으로 확보하기 힘든 실정이다. 따라서 지진을 대비한 상수도 시스템의 내진성능 평가 방안을 연구하고 개발할 필요가 있다. 지진에 의한 상수도 시스템의 내진성능을 평가하기 위해 지반운동예측식(Ground Motion Prediction Equation, GMPE)이 활용된다. GMPE는 지진 규모 등과 같은 독립변수 와 PGV (Peak Ground Velocity), PGA (Peak Ground Acceleration)와 같은 지반운동 등을 고려하여 산정하게 된다. 우리나라에서 발생된 높은 강도의 지진 데이터는 현재까지 많이 축적되지 않아 특정 지진에 국한된 데이터를 활용하여 GMPE를 결정하는 등의 연구가 진행되었다. 본 연구에서는 우리나라에서 계측된 지진 데이터를 활용하여 국내 지진 모의에 적합한 GMPE를 선정하고자 하였으며, 이를 위해 기존 국내 지진을 기반으로 산정된 GMPE식을 분석하고 그 결과를 제시하였다. 본 연구를 통해 결정된 적정 GMPE는 상수도관망의 수리학적 내진성능 평가에 직접적으로 활용 가능하다. 즉, 파손확률 모형과의 연계를 통한 지진시 관로 파손률의 정량화가 가능하며, 파손 및 누수에 의한 단수지역 파악 등과 같은 피해범위 산정시 보다 객관적이며 합리적인 결과 도출이 가능하다. 최종적으로 이와 같은 내진 성능 정량화 결과는 지진재해가 발생하였을 경우 그 피해를 최소화할 수 있는 최적 복구방안 마련과 선제적 관망 내진설계의 기준 자료로 활용될 수 있다.

터널 지열 활용을 위한 에너지 텍스타일의 열교환 성능 연구 (Study on Thermal Performance of Energy Textile in Tunnel)

  • 이철호;박상우;손병후;최항석
    • 대한토목학회논문집
    • /
    • 제33권5호
    • /
    • pp.1907-1914
    • /
    • 2013
  • 터널 내부의 지열을 활용하여 지열 냉난방 시스템 가동에 필요한 열에너지를 얻을 수 있는 텍스타일 형태의 지중열교환기(에너지 텍스타일)를 충남 서천군 일대의 철도 폐터널 벽면에 시험 시공하였다. 현장에 설치된 에너지 텍스타일의 성능을 평가하기 위해 냉방 운영과 난방 운영에 대한 일일 냉난방 모사 시험을 수행하였다. 일일 냉난방 모사 시험을 진행하는 동안 터널 벽면에 설치된 지중 열교환기로 유입/유출되는 순환수의 온도, 순환 유량, 터널 벽면 내부 지반의 온도, 터널 내부의 온도를 지속적으로 측정하였다. 시험을 통해 현장에 설치된 에너지 텍스타일은 난방가동에서 에너지 텍스타일 유닛당 57.6~143.5 W의 열교환률을 보였고 냉방가동에서는 362.3~558.4 W의 열교환률을 보였다. 또한, 시험결과로부터 터널에 설치된 지중열교환기의 열교환 성능은 터널 내부 기온의 변화에 큰 영향을 받는 것으로 나타났다. 또한, 전산유체 수치해석을 통하여 터널 내부 기온 변화를 고려한 현장 시험을 모사하여 적용된 수치해석 모델을 검증하였다. 검증된 수치해석 모델을 이용하여 콘크리트 라이닝 내부의 유도 배수재 설치 유무에 따른 에너지 텍스타일의 열적 거동에 대한 매개변수 연구를 수행하였다.

열응답시험 데이터를 이용한 SCW형 지중열교환기 블리딩 효과 분석 (An Analysis on the Bleeding Effect of SCW Ground Heat Exchanger using Thermal Response Test Data)

  • 장근선;김민준
    • 한국산학기술학회논문지
    • /
    • 제21권1호
    • /
    • pp.512-520
    • /
    • 2020
  • 개방형 지중열교환기(SCW)는 수직 밀페형 지중열교환기에 비해 높은 용량과 효율을 갖고 있어 최근에 우리나라에서 많이 보급되고 있는 추세이다. SCW형 지중열교환기의 여러 설계 및 운전변수 중 블리딩 운전이 지중 열전도율, 보어홀 열저항 등 열성능 개선에 가장 효과가 큰 것으로 보고되고 있다. 본 연구에서는 SCW형 지중열교환기가 설치된 현장의 열응답시험 결과를 기반으로 블리딩해석 모델을 정립하고 블리딩율 및 지하수 유입수의 위치변화가 SCW형 지중열교환기 열성능에 미치는 영향을 수치해석을 통하여 고찰하였다. 해석결과 지하수가 지중열교환기 상부에서 유입될 경우 지중열교환기 순환수의 시간에 따른 온도증가는 블리딩율이 증가함에 따라 낮아지는 경향을 보였으며, 지중 열전도율은 30% 블리딩율에서 179% 증가하는 결과를 보였다. 반면에 지하수가 지중열교환기 하부에서 유입될 경우 지중열교환기 순환수는 지중과 먼저 열교환을 한 후 유입수와 하단에서 혼합되기 때문에 지중열교환기 순환수의 온도증가는 상부 유입의 경우보다 적으며 블리딩율이 약 10%를 초과하면 일정하게 유지되는 경향을 보였다.

반포화 순환 여과식 인공습지에 의한 도로 강우유출수의 실증처리 연구 (Demonstration Study of Half-Saturated Bio-filter Wetland with Recirculation Pump for Road Stormwater)

  • 박기수;김영철
    • 한국습지학회지
    • /
    • 제19권3호
    • /
    • pp.259-270
    • /
    • 2017
  • 본 연구는 실증규모의 반포화 순환식 인공습지에서 도로 강우유출수를 처리하여 습지의 성능분석, LID 기능 및 다른 LID-BMP 시설과의 처리효율을 비교하였다. 강우시 모니터링을 바탕으로 연구대상 습지의 저감효율을 산정한 결과 TSS 저감효율은 평균 92%, COD, TN, TP는 각각 평균 63%, 36%, 75%로 분석되었으며 다른 시설과 직접적인 비교는 불가능하지만 SA/CA 비율에 따른 오염물질 저감효율을 분석한 결과 연구대상 시설의 SA/CA 비율이 낮았음에도 불구하고 유사한 수준의 효율을 보였다. 또한, 전체 강우유출수의 18%만을 처리하여 약 70%의 오염물질을 저감할 수 있는 시설의 성능을 보였다. 연구대상 습지(합성섬유 충진)와 동일한 형태로 제작되어 직접적인 비교가 가능했던 유기성 여재를 충진한 습지와의 비교 결과 TSS, TP는 유사한 처리성능을 보였으며, COD는 유기성 여재에서 용출되는 유기물질의 영향으로 연구대상 습지에서 높은 효율을 보였으나 TN은 유기성 여재에서 자체 공급되는 유기탄소의 영향으로 유기성 여재를 충진한 습지에서 높은 효율을 나타내었다. 한편 초기 강우유출수 포착장치를 갖춘 본 연구대상 습지에서 그렇지 않은 침투도랑 습지의 성능을 비교분석한 결과 훨씬 안정적인 처리성능을 얻을 수 있었다.

R32/R152a 혼합냉매를 적용한 해양온도차발전의 기초성능해석 (Basic performance analysis of ocean thermal energy conversion using the refrigerant mixture R32/R152a)

  • 차상원;이호생;문덕수;김현주
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권4호
    • /
    • pp.502-507
    • /
    • 2014
  • 본 논문에서는 혼합작동유체를 해양온도차발전에 적용하였을 때에 그에 따른 사이클의 성능특성에 대해 연구를 수행하였다. 다양한 혼합작동유체 중 본 논문에서는 R32/R152a를 해양온도차발전에 적용하였다. 사이클로는 기존의 밀폐형사이클, 암모니아/물 혼합물에 적용하고 있는 칼리나 사이클에 대해 시뮬레이션 해석을 수행하였고, 온열원의 온도는 $26^{\circ}C$, 냉열원의 온도는 $5^{\circ}C$를 적용하였다. R32를 적용한 밀폐사이클의 출력은 22kW, 사이클의 효율은 2.02%를 보였다. 혼합작동유체를 적용하였을 때에 R32/R152a(90%:10%)의 출력은 29.93kW, 사이클 효율은 2.78%로 기존의 단일 냉매보다 36%, 사이클효율은 37%상승함을 확인 하였다. 칼리나 사이클 또한 위와 같은 방법으로 연구를 수행하였다.

실측데이터를 이용한 저에너지주택의 에너지성능평가 (Energy Performance Evaluation of Low Energy Houses using Metering Data)

  • 백남춘;김성범;오병칠;윤종호;신우철
    • 설비공학논문집
    • /
    • 제27권7호
    • /
    • pp.369-374
    • /
    • 2015
  • This study analyzed analyzes the energy performance of six houses in Daejeon completed which were built in 2011. Observed The observed houses, which were all designed and constructed inof the same size and structure, are were highly insulated with triple Low-E coating windows; the insulation level of the walls is was $0.13W/m^2K$ and that of the roof is was $0.10W/m^2K$. As electric houses, all of the energy supplied to the houses, including for cooking, is was supplied by electricity. A and 3~4 kWp of photovoltaic system and a 3~5 kW of ground source heat pump (GSHP) were installed in each house tofor providing provide space heating/and cooling and hot water are installed. We constructed a Web-based remote monitoring system in order to understand energy consumption and the dynamic behavior of the energy system. T, and the results of our metering data analysis of 2013 are as follows. First, the annual residential energy consumption is was 4,400 kWh (${\sigma}=1,209$) and GSHP energy consumption is was 5,182 kWh (${\sigma}=1,164$). Second, residential energy consumption ranked highest in average energy usage, with at 45% of the total, followed by heating with at 30%, hot water supply with at 17% and cooling with at 6%. Third, the average energy independence rate is was 51.8%, the GFA (Gross gross floor area) criteria average energy consumption unit is was $48.7kWh/m^2yr$ (${\sigma}=10.1$), and the net energy consumption unit (except the energy yield of the PV systems) is was $24.7kWh/m^2yr$ (${\sigma}=8.8$).

가스엔진용 유기랭킨사이클의 설계 및 제작 (Design and Construction of a Bottoming Organic Rankine Cycle System for an Natural Gas Engine)

  • 이민석;백승동;성태홍;김현동;채정민;조영아;김형태;김경천
    • 한국가스학회지
    • /
    • 제20권6호
    • /
    • pp.65-72
    • /
    • 2016
  • 천연가스용으로 개조된 가스엔진에서 방출되는 폐열을 활용하기 위한 유기 랭킨사이클 (Organic Rankine Cycle: ORC) 발전시스템을 설계 및 제작하였다. 이 연구에서는 개조된 가스엔진의 폐열을 실험적으로 분석한 데이터를 바탕으로 구성한 ORC 시스템의 컴포넌트를 설계하고 제작하였다. ORC 시스템에는 2개의 판형 열교환기와 5kW급 팽창기, 다단 펌프가 사용되었으며, 전기 히터를 이용하여 ORC 시스템의 열역학적 성능을 분석하였다. 또한, 실제로 가스엔진과 연동하여 작동 특성을 파악하기 위한 실험을 수행하였다. ORC 시스템에 열량을 공급해주는 2대의 가스엔진을 사용하였다. 열원모사실험 결과, 열원온도 $110^{\circ}C$에서 축동력 5.22kW가 발생, 압력비 7.41, 열효율 9.09%가 계산되어졌으며, 엔진연동실험에서는 고온수 온도 $86^{\circ}C$에서 축동력 2kW가 발생, 이 때의 압력비는 3.75, 열효율 6.45%가 계산되었다.