• 제목/요약/키워드: Pump Performance Characteristic

검색결과 90건 처리시간 0.023초

소형 다이아프램 펌프의 성능 특성에 관한 실험적 연구 (An Experimental Study on the Performance of Mini-Diaphragm Pump)

  • 서현석;김태안;김윤제
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3134-3138
    • /
    • 2007
  • The objective of this paper is to elucidate the characteristic performance of the mini-vacuum pump with various heights of eccentric shaft. The mini-diaphragm pump is composed of DC motor, eccentric shaft and diaphragm and it is operated by PCB panel. The height of eccentric shaft is changed that controls the quantities of air flow to improve the performance of vacuum pressure. This device is manufactured in order to embody the vacuum pressure with 200 mmHg. The heights of eccentric shaft which is used in present experiment are located in the range from 3 mm to 5.5 mm. The vacuum pressure distributions with each height of eccentric shaft was measured and the results were graphically depicted.

  • PDF

전산유체해석을 이용한 축류펌프의 성능예측 (Prediction of Axial Pump Performance Using CFD Analysis)

  • 김민환;김종인;박진석
    • 한국전산유체공학회지
    • /
    • 제6권1호
    • /
    • pp.14-20
    • /
    • 2001
  • The CFD analysis of the three-dimensional turbulent flow in the impeller and diffuser of an axial flow pump was performed. Not only the design point but also the off-design points were computed. The results were compared with available experimental data in terms of head generated. At the design point, the analysis accurately predicted the experimental head value. In the range of the higher flow rates, the results were also in very good agreement with the experimental data, not only in absolute value but also in term of slope. Although experimental data to be compared were not available in the range of the lower flow rates, the results well described the S-shape performance curve of the axial pump characteristic.

  • PDF

이중 열원 히트펌프 시스템의 난방 성능과 운전 특성 (Heating Performance of Heat Pump System Using Dual Heat Source and Its Operation Characteristics)

  • 임효재;손병후
    • 한국지열·수열에너지학회논문집
    • /
    • 제17권2호
    • /
    • pp.30-41
    • /
    • 2021
  • This paper presents the heating performance analysis results of a heat pump system using a dual heat source. In this paper, a dual heat source refers to the ground-coupled heat exchanger using both a surface water heat exchanger (SWHE) and a vertical ground heat exchanger (VGHE). In order to evaluate the system performance, we installed a monitoring system to measure the temperature and power consumption of a heat pump and then collected operation data with 4 different load burdened ratios of the dual heat source heat exchanger. During the whole measurement period, the average heating capacity of a water-to-water heat pump unit was 37.3 kW. In addition, the compressor of the heat pump consumed 9.4 kW of power, while the circulating pump of the dual heat source heat exchanger used 6.7 kW of power. Therefore the average heating coefficient of performance (COP) for the heat pump unit was 4.0, while the entire system including the circulating pump was 2.7. Finally, the parallel use of SWHE and VGHE was beneficial to the system performance; however, further researches are needed to optimize the design data for various load ratios of the dual heat source heat exchanger.

래이디얼 피스톤 펌프의 효율 특성 연구 (A Characteristic Study of Efficiency in Radial Piston Pump)

  • 장윤석;천세민;임윤철
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2000년도 제31회 춘계학술대회
    • /
    • pp.106-113
    • /
    • 2000
  • A pump which is a fundamental device in a hydraulic system affects on overall system performance to a great deal. Such problems as leakage and solid friction loss become important in field applications, especially for the case of operation under high pressure and at high speed. So the research on this kind of subjects is necessary to improve the performance of hydraulic devices. A high pressure radial piston pump is analyzed here, which has a stationary cylinder block. It pumps hydraulic fluid by letting camring push a piston in a cylinder. Fluid leaks between the piston and cylinder so that it deteriorates the pump efficiency. Furthermore, the piston happens to touch the cylinder wall to increase the friction loss and wear. In this research, by means of FDM, volumetric, mechanical and overall efficiencies are observed by varying several design Parameters and operation conditions. Design values or their trends are presented to improve these efficiencies.

  • PDF

레이디얼 피스톤 펌프의 효율 특성 연구 (A Characteristic Study of Efficiency in Radial Piston Pump)

  • 장윤석;천세민;임윤철
    • Tribology and Lubricants
    • /
    • 제16권4호
    • /
    • pp.259-265
    • /
    • 2000
  • Pump which is the fundamental device in the hydraulic system affects on overall system performance to a great deal. Such problems as leakage and solid friction loss become important in field applications, especially for the case of operation under high pressure and at high speed. So the research on this kind of subjects is necessary to improve the performance of hydraulic devices. A high pressure radial piston pump is analyzed here, which has a stationary cylinder block. It pumps hydraulic fluid by letting camring push a piston in a cylinder. Fluid leaks between the piston and cylinder so that it deteriorates the pump efficiency. Furthermore, the piston happens to touch the cylinder wall to increase the friction loss and wear. In this research, by means of FDA, volumetric, mechanical and overall efficiencies are observed by varying several design parameters and operation conditions. Design values or their trends are presented to improve these effciencies.

자동차 PS용 베인펌프의 캠곡선 설계 (Design for Cam Curve of a Oil Hydraulic Vane Pump for Vehicles′ Power Steering System)

  • 정석훈;정재연
    • Tribology and Lubricants
    • /
    • 제20권3호
    • /
    • pp.157-162
    • /
    • 2004
  • The cam curve of a balance type vane pump consists usually of circular arcs and Archimedes' spirals. However, if they are connected directly together, the curve must have a few discontinuous points of the gradients and the motion of the vanes is no longer smooth. Designing data for an oil hydraulic vane pump used in power steering system were obtained by the acquisition of optimum cam profile data which can be available to reduce noises and vibrations through the minimization of cavitation with the improvement of suctional performance. The performance test is carried on the trial manufactures by measuring the volumetric and the mechanical efficiency. And from that result, maintaining the same characteristic as the conventional one in the relief pressure and noise level, the experimental pump discharges 0.7 $\ell$/min and shows nearly 3.5% enhancement in the total efficiency more than the conventional one.

Numerical Study of Inlet and Impeller Flow Structures in Centrifugal Pump at Design and Off-design Points

  • Cheah, Kean Wee;Lee, Thong-See;Winoto, S.H.
    • International Journal of Fluid Machinery and Systems
    • /
    • 제4권1호
    • /
    • pp.25-32
    • /
    • 2011
  • The objective of present work is to use numerical simulation to investigate the complex three-dimensional and secondary flow structures developed at the inlet and impeller in a centrifugal pump at design and off-design points. The pump impeller is shrouded with 6 backward swept blades and with a specific speed of 0.8574. The characteristic of the pump is measured experimentally with straight and curved intake sections. Numerical computation is carried out to investigate the pump inlet flow structures and subsequently the flow field within the centrifugal pump. The numerical results showed that strong interaction between the impeller eye and intake section. Secondary flow structure occurs upstream at the pump inlet has great influence on the pump performance and flow structure within the impeller.

The Characteristics of a Pump at Nearly Saturated State

  • Kim, S. N.;Kim, J. C.
    • Nuclear Engineering and Technology
    • /
    • 제30권1호
    • /
    • pp.40-46
    • /
    • 1998
  • A set of experiments using a 1/10 scale model pump which was manufactured to simulate performance of reactor coolant pump(RCP) of Y.G.N # 3 and 4, was executed in single phase(at atmospheric pressure and room temperature) and near-saturation(300 ~ 600kPa). The pump characteristics in single phase flow was similar to the characteristics of the RCP. The pump characteristic curves at nearly saturated state were correlated in terms of flow coefficient and head coefficient for subcooled temperature using the cavitation number defined as (equation omitted), which can be predicted the cavitation possibility. The pump behavior around the saturated temperature almost consists with single phase behavior until the cavitation occurs(When cavitation occurs. When the flow coefficient is about 0.12), the pump head rapidly degrades. In this situation, subcooled temperature is about 1.8~8$^{\circ}C$ and cavitation number of model pump is 1.0 ~ 1.7.

  • PDF

Effects of the Geometry of Components Attached to the Drain Valve on the Performance of Water Hammer Pumps

  • Saito, Sumio;Takahashi, Masaaki;Nagata, Yoshimi;Dejima, Keita
    • International Journal of Fluid Machinery and Systems
    • /
    • 제4권4호
    • /
    • pp.367-374
    • /
    • 2011
  • Water hammer pumps can effectively use the water hammer phenomenon in long-distance pipeline networks that include pumps and allow fluid transport without drive sources, such as electric motors. The results of experiments that examined the effect of the geometric form of water hammer pumps by considering their major dimensions have been reported. In addition, a paper has also been published analyzing the water hammer phenomenon numerically by using the characteristic curve method for comparison with experimental results. However, these conventional studies have not fully evaluated the pump performance in terms of pump head and flow rate, common measures indicating the performance of pumps. Therefore, as a first stage for the understanding of water hammer pump performance in comparison with the characteristics of typical turbo pumps, the previous paper experimentally examined how the hydrodynamic characteristics were affected by the inner diameter ratio of the drive and lifting pipes, the form of the air chamber, and the angle of the drive pipe. To understand the behavior of the components attached to the valve chamber and the air chamber that affects the performance of water hammer pumps, the previous study also determined the relationship between the water hammer pump performance and temporal changes in valve chamber and air chamber pressures according to the air chamber capacity. For the geometry of components attached to the drain valve, which is another major component of water hammer pumps, this study experimentally examines how the water hammer pump performance is affected by the length of the spring and the angle of the drain pipe.

FMEA를 활용한 재제조 파워스티어링 오일펌프 시험법에 대한 최적화 연구 (The Optimization Study on the Test Method of Remanufactured Power Steering Oil Pump by Using FMEA)

  • 서영교;정도현;유상석;나완용
    • 한국자동차공학회논문집
    • /
    • 제24권1호
    • /
    • pp.90-98
    • /
    • 2016
  • Currently government certified test method for an automobile remanufactured products is insufficient. Thus many automotive parts in the remanufacturing market are lacking proper evaluation criteria and production of defective products are causing customer dissatisfaction. In this paper a power steering oil pump, which requires stringent manufacturing standards, is studied by the failure mode and effect analysis approach. The research suggested that the test criteria such as discharge flow characteristic test, tightness test, pulley run-out test, pressure switch operation test, low temperature test and rotation pressure durability test should be performed to evaluate the reliability of remanufactured power steering oil pumps. As a result of tests, the performance of remanufactured power steering oil pump satisfied the evaluation criteria of pressure switch operation test and low temperature test. However, the remanufactured power steering oil pump failed to satisfy the evaluation criteria on discharge performance test, tightness test and pulley run-out test. These performance evaluation tests proved the necessity of standard process for the remanufactured power steering oil pump.