• Title/Summary/Keyword: Pump Monitoring

Search Result 190, Processing Time 0.033 seconds

Development of Smart Air Car Seat Control System for Automatic Air Conditioning using IoT Sensor (IoT 센서를 이용한 공기 자동조절 스마트 에어카시트 제어 시스템 개발)

  • Kim, Dae-Hun;Jeong, Sueun;Park, Suhyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.10a
    • /
    • pp.208-210
    • /
    • 2021
  • As the number of objects connected to the Internet increases rapidly, intelligent device development projects are gradually expanding that provide direct value to humans, away from simple monitoring functions, including sensors and communication functions, or delivery to servers.It is expected that the device will develop a technology that analyzes surrounding sensing information and changes the surrounding environment in consideration of users' preferences or safety. By establishing a biosignal measurement system in a developed product that can bring various effects using air, it will be possible to grasp the user's condition through a pattern of change in pressure distribution when seated. This paper proposes a construction system that enhances the comfort of using an air car seat through contact between a temperature measurement sensor and a user, and enables effective management of measured biosignals by linking them with an air pump control system.

  • PDF

Development of An Actuator-Based Blood Pressure Simulator for Automatic Blood Pressure Monitor (자동혈압계 점검을 위한 액추에이터 기반의 혈압 시뮬레이터 개발)

  • Soo Hong Kim;Seung Jun Lee;Mun Hyeok Lim;Hye Min Park;Min Seok Gang;Gun Ho Kim;Kyoung Won Nam
    • Journal of Biomedical Engineering Research
    • /
    • v.45 no.1
    • /
    • pp.49-55
    • /
    • 2024
  • Accurate measurement of blood pressure is essential for classifying an individual's disease, identifying blood pressure-related risks, and managing health. Due to the environmental and health hazards of mercury sphygmomanometers, automatic sphygmomanometers using the oscillometric method are widely used in hospitals as well as in general homes, and have established themselves as a practical standard sphygmomanometer. In this study, we developed a blood pressure simulator using an actuator that provides simulated pressure to an automatic blood pressure cuff. The developed blood pressure simulator adopts an arm-shaped cylindrical shape similar to the situation in which a person measures blood pressure with an automatic blood pressure monitor, and implements a method of transmitting pressure to the cuff using a pressure plate. Accuracy was evaluated through the mean and standard deviation of the difference with the commercialized blood pressure simulator BP PUMP 2, and reproducibility was confirmed using two automatic blood pressure monitors. The developed blood pressure simulator enables automatic blood pressure monitoring in a simple manner and also meets the evaluation standards for accuracy and reproducibility. In the future, as a standardized blood pressure simulator, it is expected to be of great help in evaluating and verifying the performance of automatic blood pressure monitors by supplementing precise hardware and software and building a blood pressure database.

In Situ Surfactant Flushing of Contaminated Site (계면 활성제를 이용한 In Situ 토양 세척)

  • 염익태;안규홍
    • Journal of Korea Soil Environment Society
    • /
    • v.2 no.2
    • /
    • pp.9-24
    • /
    • 1997
  • Surfactant-aided in situ soil flushing has been proposed as an alternative for the expensive and time consuming 'pump and treat' technology in remediation of contaminated soil and groundwater Injected surfactants can effectively solubilize contaminants sorbed to the soil matrix or nonaqueous phase liquids(NAPLs) in residual saturation. The contaminants solubilized in groundwater are recovered and treated further. The theoretical background of the technology and the results of the field operations, mostly in the US. were summarized. In addition, the factors crucial to the successful application of the technology were discussed. Cost analyses and technical limitations in current applications were also discussed. In conclusion, it is likely that in situ surfactant flushing become a viable option for soil remediation in limited cases. Currently, further advances with respect to operation cost and to treatment efficiency are required for more extensive application of the technology. However, the current trends in soil remediation, specially the growing emphasis on risk based corrective action and natural attenuation, will increase the competitiveness of the technology. For example, removal of easily washable contaminants by short term soil flushing followed by long term monitoring and natural attenuation can greatly reduce the operation cost and time.

  • PDF

Distribution and Behavior of Soil CO2 in Pohang area: Baseline Survey and Preliminary Interpretation in a Candidate Geological CO2 Storage Site (포항 지역 토양 CO2의 분포 및 거동 특성 연구: CO2 지중저장 부지 자연 배경 조사 및 예비 해석)

  • Park, Jinyoung;Sung, Ki-Sung;Yu, Soonyoung;Chae, Gitak;Lee, Sein;Yum, Byoung-Woo;Park, Kwon Gyu;Kim, Jeong-Chan
    • Journal of Soil and Groundwater Environment
    • /
    • v.21 no.1
    • /
    • pp.49-60
    • /
    • 2016
  • Distribution and behavior of baseline soil CO2 were investigated in a candidate geologic CO2 storage site in Pohang, with measuring CO2 concentrations and carbon isotopes in the vadose zone as well as CO2 fluxes and concentrations through ground surface. This investigation aimed to assess the baseline CO2 levels and to build the CO2 monitoring system before injecting CO2. The gas in the vadose zone was collected using a peristaltic pump from the depth of 60 cm below ground surface, and stored at gas bags. Then the gas components (CO2, O2, N2, CH4) and δ13CCO2 were analyzed using GC and CRDS (cavity ringdown spectroscopy) respectively in laboratory. CO2 fluxes and CO2 concentrations through ground surface were measured using Li-COR in field. In result, the median of the CO2 concentrations in the vadose zone was about 3,000 ppm, and the δ13CCO2 were in the wide range between −36.9‰ and −10.6‰. The results imply that the fate of CO2 in the vadose zone was affected by soil property and vegetations. CO2 in sandy or loamy soils originated from the respiration of microorganisms and the decomposition of C3 plants. In gravel areas, the CO2 concentrations decreased while the δ13CCO2 increased because of the mixing with the atmospheric gas. In addition, the relation between O2 and CO2, N2, and the relation between N2/O2 and CO2 implied that the gases in the vadose zone dissolved in the infiltrating precipitation or the soil moisture. The median CO2 flux through ground surface was 2.9 g/m2/d which is lower than the reported soil CO2 fluxes in areas with temperate climates. CO2 fluxes measured in sandy and loamy soil areas were higher (median 5.2 g/m2/d) than those in gravel areas (2.6 g/m2/d). The relationships between CO2 fluxes and concentrations suggested that the transport of CO2 from the vadose zone to ground surface was dominated by diffusion in the study area. In gravel areas, the mixing with atmospheric gases was significant. Based on this study result, a soil monitoring procedure has been established for a candidate geologic CO2 storage site. Also, this study result provides ideas for innovating soil monitoring technologies.

Principles and Applications of Multi-Level H2O/CO2 Profile Measurement System (다중 수증기/이산화탄소 프로파일 관측 시스템의 원리와 활용)

  • Yoo, Jae-Ill;Lee, Dong-Ho;Hong, Jin-Kyu;Kim, Joon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.11 no.1
    • /
    • pp.27-38
    • /
    • 2009
  • The multi-level profile system is designed to measure the vertical profile of $H_2O$ and $CO_2$ concentrations in the surface layer to estimate the storage effects within the plant canopy. It is suitable for long-term experiments and can be used also in advection studies for estimating the spatial variability and vertical gradients in concentration. It enables the user to calculate vertical fluxes of water vapor, $CO_2$ and other trace gases using the surface layer similarity theory and to infer their sources or sinks. The profile system described in this report includes the following components: sampling system, calibration and flow control system, closed path infrared gas analyzer(IRGA), vacuum pump and a datalogger. The sampling system draws air from 8 inlets into the IRGA in a sequence, so that for 80 seconds air from all levels is measured. The calibration system, controlled by the datalogger, compensates for any deviations in the calibration of the IRGA by using gas sources with known concentrations. The datalogger switches the corresponding valves, measures the linearized voltages from the IRGA, calculates the concentrations for each monitoring level, performs statistical analysis and stores the final data. All critical components are mounted in an environmental enclosure and can operate with little maintenance over long periods of time. This report, as a practical manual, is designed to provide helpful information for those who are interested in using profile system to measure evapotranspiration and net ecosystem exchanges in complex terrain.

Conceptual Design of Mechanical System for Recovery of Seabed-Deposited Hazardous and Noxious Substances Based on Performance Requirements (해저침적 HNS 회수용 기계장치의 성능요건 기반 개념설계)

  • Hwang, Ho-Jin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.6
    • /
    • pp.689-697
    • /
    • 2020
  • Hazardous and noxious substances (HNS) may cause maritime incidents during marine transportation, which are liable to lead to a large amount of spillage or discharge into the sea. The damage to the marine environment caused by the HNS spill or discharge is known to be much greater than the damage caused by oil spill. Particularly dangerous is HNS, which is deposited or buried in the seabed, as it can damage the organisms that live on, in, and near the bottom of the sea, the so-called "benthos," forming the benthic ecosystem. Therefore, it is vital that the HNS deposited on the seabed be recovered. In order to do so, procedures and equipment are required for accurate detection, stabilization treatment, and recovery of HNS in subsea sediment. Thus, when developing a mechanical recovery system, the performance requirements should be selected using performance indices, and the conceptual design of the mechanical recovery system should be based on performance requirements decided upon and selected in advance. Therefore, this study was conducted to arrive at a conceptual design for a mechanical recovery system for the recovery of HNS deposited on the seabed. In the design of the system, based on the fundamental scenario, the method of suction foundation with the function of self enclosing was adopted for recovering the HNS sediment in the subsea sediment. The mechanical recovery system comprises the suction foundation, pollution prevention, a pump system, control system, monitoring device, location information device, transfer device, and tanks. This conceptual design is expected to be reflected and used in the basic design of the components and shapes of the mechanical recovery system.

Analysis of Heavy Metal Element and Microorganism by Manufacture of Particulate Matter Sampler for Science Project of Secondary School (중등학교에서 사용 가능한 미세먼지 포집 장치 제작을 통한 대기 중 중금속 및 미생물 분석)

  • Kwon, Woo-Jin;Kim, Young-Jae;Byeon, Jung-Ho
    • Journal of the Korean earth science society
    • /
    • v.36 no.1
    • /
    • pp.125-135
    • /
    • 2015
  • The purpose of this study were to sample particulate matter and analyze its elements and microorganisms for secondary school science project. The particulate matter was sampled on the rooftop a four-store building at a university in Chungju province. A simplified capturing system was developed with the parts, motor-pump, innet, $1.0{\mu}m$ teflon filter, filter-holder, etc. Using the system, this study had sampled particulate matter during Dec., 2013-Jun., 2014. Then, this study analyzed the elements and microorganisms of the sampled particulate matter. Results have been shown that the particulate matter derived China urban area is mainly consisted of the artificial pollutant, such as Cu, Zn, Cd, Ni, Pb. In addition, this study has been shown that microorganisms, such as bacteria and fungi, are included in the particulate matter. Therefore, this study suggests a new systemic investigation and monitoring about the particulate matter, specially originated from China. Also, this study provides a sample for secondary school science experiment.

Integrated RT-PCR Microdevice with an Immunochromatographic Strip for Colorimetric Influenza H1N1 virus detection

  • Heo, Hyun Young;Kim, Yong Tae;Chen, Yuchao;Choi, Jong Young;Seo, Tae Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.273-273
    • /
    • 2013
  • Recently, Point-of-care (POC) testing microdevices enable to do the patient monitoring, drug screening, pathogen detection in the outside of hospital. Immunochromatographic strip (ICS) is one of the diagnostic technologies which are widely applied to POC detection. Relatively low cost, simplicity to use, easy interpretations of the diagnostic results and high stability under any circumstances are representative advantages of POC diagnosis. It would provide colorimetric results more conveniently, if the genetic analysis microsystem incorporates the ICS as a detector part. In this work, we develop a reverse transcriptase-polymerase chain reaction (RT-PCR) microfluidic device integrated with a ROSGENE strip for colorimetric influenza H1N1 virus detection. The integrated RT-PCR- ROSGENE device is consist of four functional units which are a pneumatic micropump for sample loading, 2 ${\mu}L$ volume RT-PCR chamber for target gene amplification, a resistance temperature detector (RTD) electrode for temperature control, and a ROSGENE strip for target gene detection. The device was fabricated by combining four layers: First wafer is for RTD microfabrication, the second wafer is for PCR chamber at the bottom and micropump channel on the top, the third is the monolithic PDMS, and the fourth is the manifold for micropump operation. The RT-PCR was performed with subtype specific forward and reverse primers which were labeled with Texas-red, serving as a fluorescent hapten. A biotin-dUTP was used to insert biotin moieties in the PCR amplicons, during the RT-PCR. The RT-PCR amplicons were loaded in the sample application area, and they were conjugated with Au NP-labeled hapten-antibody. The test band embedded with streptavidins captures the biotin labeled amplicons and we can see violet colorimetric signals if the target gene was amplified with the control line. The off-chip RT-PCR amplicons of the influenza H1N1 virus were analyzed with a ROSGENE strip in comparison with an agarose gel electrophoresis. The intensities of test line was proportional to the template quantity and the detection sensitivity of the strip was better than that of the agarose gel. The test band of the ROSGENE strip could be observed with only 10 copies of a RNA template by the naked eyes. For the on-chip RT-PCR-ROSGENE experiments, a RT-PCR cocktail was injected into the chamber from the inlet reservoir to the waste outlet by the micro-pump actuation. After filling without bubbles inside the chamber, a RT-PCR thermal cycling was executed for 2 hours with all the microvalves closed to isolate the PCR chamber. After thermal cycling, the RT-PCR product was delivered to the attached ROSGENE strip through the outlet reservoir. After dropping 40 ${\mu}L$ of an eluant buffer at the end of the strip, the violet test line was detected as a H1N1 virus indicator, while the negative experiment only revealed a control line and while the positive experiment a control and a test line was appeared.

  • PDF

Effect of Intracarotid Cold Saline Infusion during Cerebral Ischemia on Brain Edema in the Rabbit (뇌허혈기동안 경동맥으로 냉각 생리식염수 주입이 허혈후 뇌부종에 미치는 영향)

  • Kim, Sae-Yeon;Choi, Kyu-Taek
    • Journal of Yeungnam Medical Science
    • /
    • v.12 no.2
    • /
    • pp.260-268
    • /
    • 1995
  • Ischemia results when the decrease in tissue perfusion exceeds the tissues ability to increase an oxygen extraction from the blood. Brain edema has been defined as an abnormal accumulation of fluid within brain parenchyma associated with a volumetric enlargement of the brain tissue. In most instances, the labelling of edema as vasogenic or cytotoxic is only relative. For cerebral protection, there were many possible techniques which could increase or maintain cerebral perfusion and reduce cerebral metabolic demand for oxygen. This study was carried out the effect of mild brain hypothermia which was induced by infusion with cold saline into the carotid artery, during brief episodes of transient global ischemia on postischemic brain edema in rabbit. Eight rabbits were anesthetized with halothane and mechanically ventilated with oxygen. For isolated cerebral perfusion, polyethylene catheter was inserted left carotid artery for infusion of cold saline, external carotid artery was ligated, vertebral arteries were cautherized, right carotid artery was snared for ischemia and femoral artery and vein were also canulated for monitoring and drug treatment. At 3 hours After transient global ischemia, specific gravity of cerebral cortex and hippocampus was compared with no-perfusion group , perfusion with cold saline group and normal group. There was no significant differences in physiologic variables among the groups before transient global ischemia. But during transient global ischemia, brain temperature of perfusion group was decreased when compared to no perfusion group. Specific gravity of cerebral cortex and hippocampus of no-perfusion group and perfusion group was statistically significant when compared to normal group (p<0.01). The results of this study suggested that mild brain hypothermia with intracarotid cold saline infusion during brief episodes of transient global ischemia had decreased postischemic brain edema in rabbit.

  • PDF

Preliminary Study on the MR Temperature Mapping using Center Array-Sequencing Phase Unwrapping Algorithm (Center Array-Sequencing 위상펼침 기법의 MR 온도영상 적용에 관한 기초연구)

  • Tan, Kee Chin;Kim, Tae-Hyung;Chun, Song-I;Han, Yong-Hee;Choi, Ki-Seung;Lee, Kwang-Sig;Jun, Jae-Ryang;Eun, Choong-Ki;Mun, Chi-Woong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.2
    • /
    • pp.131-141
    • /
    • 2008
  • Purpose : To investigate the feasibility and accuracy of Proton Resonance Frequency (PRF) shift based magnetic resonance (MR) temperature mapping utilizing the self-developed center array-sequencing phase unwrapping (PU) method for non-invasive temperature monitoring. Materials and Methods : The computer simulation was done on the PU algorithm for performance evaluation before further application to MR thermometry. The MR experiments were conducted in two approaches namely PU experiment, and temperature mapping experiment based on the PU technique with all the image postprocessing implemented in MATLAB. A 1.5T MR scanner employing a knee coil with $T2^*$ GRE (Gradient Recalled Echo) pulse sequence were used throughout the experiments. Various subjects such as water phantom, orange, and agarose gel phantom were used for the assessment of the self-developed PU algorithm. The MR temperature mapping experiment was initially attempted on the agarose gel phantom only with the application of a custom-made thermoregulating water pump as the heating source. Heat was generated to the phantom via hot water circulation whilst temperature variation was observed with T-type thermocouple. The PU program was implemented on the reconstructed wrapped phase images prior to map the temperature distribution of subjects. As the temperature change is directly proportional to the phase difference map, the absolute temperature could be estimated from the summation of the computed temperature difference with the measured ambient temperature of subjects. Results : The PU technique successfully recovered and removed the phase wrapping artifacts on MR phase images with various subjects by producing a smooth and continuous phase map thus producing a more reliable temperature map. Conclusion : This work presented a rapid, and robust self-developed center array-sequencing PU algorithm feasible for the application of MR temperature mapping according to the PRF phase shift property.

  • PDF