• 제목/요약/키워드: Pump

검색결과 6,419건 처리시간 0.029초

영상처리 기법에 의한 합섬방사용 미터링 펌프의 시뮬레이션 소프트웨어 개발 (Development of Simulation Software for Metering Pump of Synthetic Fibers with Image Processing)

  • 조연상;배명호
    • 한국정밀공학회지
    • /
    • 제22권3호
    • /
    • pp.101-106
    • /
    • 2005
  • It needs to accumulate a store of know-how on the design, precision processing and appraisement for metering pump which is a kind of gear pump fer synthetic fibers. But the period and cost fur development is not effective, because designers experience many trial and error for the pump design and manufacturing process. Therefore, in order to curtail the period and cut down expenses, the analysis and simulation system is required for a designed metering pump. In this study, the pump simulation software was developed with the visual C++ language and the image processing algorithm, and was investigated through a discharge test for the planetary gear type metering pump.

Study on the Development of Two-Stage Centrifugal Blood Pump for Cardiopulmonary Support System

  • Horiguchi, Hironori;Tsukiya, Tomonori;Nomoto, Takeshi;Takemika, Toratarou;Tsujimoto, Yoshinobu
    • International Journal of Fluid Machinery and Systems
    • /
    • 제7권4호
    • /
    • pp.142-150
    • /
    • 2014
  • In the cardiopulmonary support system with an ECMO (extracorporeal membrane oxygenation), a higher pump head is demanded for a blood pump. In order to realize a blood pump with higher pump head, higher anti-hemolysis and thrombosis performances, a study on the development of unprecedented multistage blood pump was conducted. In consideration of the application of the blood pump for pediatric patients, a miniature two-stage centrifugal blood pump with the impeller's diameter of 40mm was designed and the performance was examined in experiments and computations. Some useful knowledge for a design of the blood pump with higher anti-hemolysis and thrombosis performances was obtained.

충적대수층을 이용한 지열히트펌프시스템의 냉방성능 (Cooling Performance of Geothermal Heat Pump using Alluvium Aquifer)

  • 강병찬;박준언;이철우;송윤호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 추계학술대회 논문집
    • /
    • pp.561-566
    • /
    • 2009
  • Alluvium is sedimentary stratum and composed of gravel, sand, silt, clay. Permeability of alluvium is the higher. If alluvium have lots of aquifer, will be of great use heat source and heat sink of heat pump. Alluvium aquifer contain the thermal energy of surrounding ground. Also geothermal heat pump using alluvium aquifer reduce expenses than general geothermal heat pump, because geothermal heat pump using alluvium aquifer make use of single well. In this study geothermal heat pump using alluvium aquifer was installed and tested for a building. The heat pump capacity is 30USRT. Temperature of ground water is in $12{\sim}17^{\circ}C$ annually and the quality of the water is as good as living water. The heat pump cooling COP is 4.4 ~ 4.7. The system cooling COP is 3.25 ~ 3.6. This performance is as good as BHE type ground source heat pump.

  • PDF

온수 보일러용 열구동 펌프에 관한 연구 (A Study on the Thermal Pump of the Hot Water Boiler)

  • 염한길;김욱중;김창주
    • 연구논문집
    • /
    • 통권30호
    • /
    • pp.15-23
    • /
    • 2000
  • In this study, develop the thermal pump using water evaporation and condensation. Vapor from heating room moves up to pumping room and press the water of pumping room. Consequently water is pumped out to water tank. Then hot vapor direct contact with cold water in condensing room after pumping process. At this time, pressure of condensing room is down to-5kPa and suck in water of tank. This pump executes self ping and good durability because of no mechanical moving parts. Thermal pump is pumped cyclic so that, this pump is not used single. Therefore thermal pump of hot water boiler used to multi-stage for stable pumping rate. As the result of performance test, the developed thermal pump proves pumping action of water evaporation/condensation. And total volume flow rate is 500liter during one hour. If three thermal pump is installed parallel, this pump can use to the hot water boiler in the 300,000kcal/h class.

  • PDF

대체에너지 사용시 공업용수 순환 개선을 위한 연구 (Study of industrial water calculation improvement by use Alternative Energy)

  • 최도순
    • 한국정보전자통신기술학회논문지
    • /
    • 제4권4호
    • /
    • pp.307-310
    • /
    • 2011
  • 이 논문은 1년에 몇 일 혹은 몇 시간 동안 만 최대 에너지가 공급된다. 그러므로 일반적인 경우에는 대부분 최대 에너지의 50%나 이보다 적은 양의 에너지를 얻게 된다. 이런 작은량의 에너지가 공급되는 Alternative Energy system (P. Voltac System)하에서 용수공급을 위해 기존의 Centrifugal pump를 사용 할 때와 Screw type pump를 사용할 때 공급된 용수량을 비교하였다. 연구 결과 Screw type pump 사용 시 alternative Energy system의 높이에 상관없이 단지 Screw type pump의 speed에 영향을 받으며 낮은 Energy 하 에서도 비교적 높은 효율을 낸다는 것을 실험적으로 비교 검토 하였다.

전기 인버터 구동 수압 피스톤 펌프 시스템의 효율 성능에 관한 실험적 연구 (An Experimental Study on the Efficiency of the Water Hydraulic Piston Pump System driven by an Electric Inverter)

  • 함영복;박준형;김성동
    • 유공압시스템학회논문집
    • /
    • 제3권4호
    • /
    • pp.1-7
    • /
    • 2006
  • A water hydraulic pump is likely to have serious problems of high leakage, friction and low energy efficiency. A water hydraulic pump has commonly a fixed displacement type and its outlet flow is adjusted by controlling rotation speed of the pump, which can be implemented by using an electric inverter. This study aims to investigate energy efficiency of the water hydraulic pump system which is driven by an electric inverter. The study is based on the experimental results. The pump which is used in the study shows relatively good efficiency and low leakage, low friction as well. The reasons for the good performance of pump is also investigated.

  • PDF

Performances of Erbium-Doped Fiber Amplifier Using 1530nm-Band Pump for Long Wavelength Multichannel Amplification

  • Choi, Bo-Hun;Chu, Moo-Jung;Park, Hyo-Hoon;Lee, Jong-Hyun
    • ETRI Journal
    • /
    • 제23권1호
    • /
    • pp.1-8
    • /
    • 2001
  • The performance of a long wavelength-band erbium-doped fiber amplifier (L-band EDFA) using 1530nm-band pumping has been studied. A 1530nm-band pump source is built using a tunable light source and two C-band EDFAs in cascaded configuration, which is able to deliver a maximum output power of 23dBm. Gain coefficient and noise figure (NF) of the L-band EDFA are measured for pump wavelengths between 1530nm and 1560nm. The gain coefficient with a 1545nm pump is more than twice as large as with a 1480nm pump. It indicates that the L-band EDFA consumes low power. The noise figure of 1530nm pump is 6.36dB at worst, which is 0.75dB higher than that of 1480nm pumped EDFA. The optimum pump wavelength range to obtain high gain and low NF in the 1530nm band appears to be between 1530nm and 1540nm. Gain spectra as a function of a pump wavelength have bandwidth of more than 10nm so that a broadband pump source can be used as 1530nm-band pump. The L-band EDFA is also tested for WDM signals. Flat Gain bandwidth is 32nm from 1571.5 to 1603.5nm within 1dB excursion at input signal of -10dBm/ch. These results demonstrate that 1530nm-band pump can be used as a new efficient pump source for L-band EDFAs.

  • PDF

한국형 원자력발전소 펌프실 면적 산정 방안 (Determination of Sizes of the Pump Rooms in Korean Nuclear Power Plants)

  • 이효승;고철균;문승재
    • 플랜트 저널
    • /
    • 제9권2호
    • /
    • pp.36-41
    • /
    • 2013
  • 펌프실 내 펌프가 1대 배치되는 경우 펌프 동력과 펌프기초 면적이 주어지면 펌프실 면적을 찾을 수 있다. 다만, 일부 펌프는 펌프와 발전소 배치 특이성에 따라 펌프실 면적이 결정된다. 그러나 펌프실 내 펌프가 2대 배치되는 경우 펌프 동력과 펌프기초 면적을 이용한 펌프실 면적을 구하는 연계관계를 찾을 수 없다. 그리고 펌프 동력과 펌프기초 면적의 연계관계도 찾을 수 없다.

  • PDF

NMR 자석용 고온 초전도 내부 코일을 위한 플럭스 폄프에 대한 실험 (Experiment of Flux pump for High Temperature Superconductor Insert coils of NMR magnets)

  • 정상권
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제3권2호
    • /
    • pp.15-20
    • /
    • 2001
  • This paper describes a model flux pump experiment recently performed at the MIT Francis Bitter Magnet Laboratory. The results of the model flux pump will be used in the development of a prototype flux pump that will be couple to a high-temperature superconductor (HTS) insert coil of a high-field NMR (Nuclear Magnetic Resonance) magnet, Such an HTS insert is unlikely to operate in persistent model because of the conductors low index(n) The flux pump can compensate fro field decay in the HTS insert coil and make the insert operate effectively in persistent mode . The flux pump, comprised essentially of a transformer an two switches. all made of superconductor, transfers into the insert coil a fraction of a magnetic energy that is first introduced in the secondary circuit of the transformer by a current supplied to the primary circuit. A model flux pump has been designed. fabricated, and operated to demonstrate that a flux pump can indeed supply a small metered current into a load superconducting magnet. A current increment in the range of microamperes has been measured in the magnet after each pumping action. The superconducting model flux pump is made of Nb$_3$ Sn tape, The pump is placed in a gaseous environment above the liquid helium level to keep its heat dissipation from directly discharged in the liquid: the effluent helium vapor maintains the thermal stability of the flux pump.

  • PDF

The Analysis of Life Cycle Cost and Cooling Water Circulating Pump Energy Saving According to Variable Speed Pressure Differential Setpoint Control Strategy

  • Kim, Seo-Hoon;Kim, Jong-Hun;Jang, Cheol-Yong;Song, Kyoo-dong
    • KIEAE Journal
    • /
    • 제15권4호
    • /
    • pp.37-43
    • /
    • 2015
  • Purpose : The study applied control strategy to reduce through optimal control and operation of pump by applying control on variable speed to the circulation pump of HVAC system in the office building. The study has the purpose to review validity of control on variable speed as ESMs(Energy Saving Measures) and establish the control technology on variable speed pump. The study performed reduction analysis of building energy and economic evaluation of pump through energy effectiveness control strategy of HVAC system. Method: The study sought possible reduction through energy control strategy which can provide proper flow fitting to building load by applying control on variable speed pump. The study applied control strategy to reduce through pressure differential set-point control and operation of pump by applying control on variable speed to the circulation pump of HVAC system in the office building. Result : The results showed that about 16-35% of pump energy could be saved by using these optimal control strategies. In the result of analysis on 10 years life cycle cost of analysis on payback period of initial investment pump, variable speed pump control showed 5.1 years.