• 제목/요약/키워드: Pump

검색결과 6,421건 처리시간 0.037초

비속도의 큰 변화가 극저비속도 원심펌프의 성능에 미치는 영향 (Influence of Large Change of Specific Speed on the Performance of Very Low Specific Speed Centrifugal Pump)

  • 최영도;카가와슈사쿠;쿠로카와준이치
    • 한국유체기계학회 논문집
    • /
    • 제9권1호
    • /
    • pp.40-46
    • /
    • 2006
  • Efficiency of a centrifugal pump is known to drop rapidly with a decrease of specific speed $n_s$. However, below $n_s=60\;[min^{-1},\;m^3/min,\;m]$, the pump characteristics are not yet clear. Therefore, present study is aimed to investigate the influence of large change of specific speed on the performance of a very low specific speed centrifugal pump. Moreover, influence of impeller configuration on the performance of very low specific speed pump is investigated. The results show that very low specific speed can be accomplished by reducing volute throat sectional area using circular spacer. Influence of the spacer's location and configuration in the discharge passage on the pump performance is very small. Best efficiency of very low specific speed centrifugal pump decreases proportionally to the specific speed but the best efficiency decreases on a large scale in the range of $n_s<40$. Influence of impeller configuration on the pump performance and radial thrust of centrifugal pump are considerably small in the range of extremely low specific speed $(n_s=25)$.

연간 성능을 고려한 가정용 태양열-흡수식 히트펌프의 에너지 절약효과 분석 (An Analysis of Energy Savings on the Solar-Absorption Heat Pump Systems for the Residential Use with the consideration of Annual Performance)

  • 이재효;이관수;원승호;이명호
    • 설비공학논문집
    • /
    • 제3권4호
    • /
    • pp.263-275
    • /
    • 1991
  • Studies on the annual performance of three different type of solar-absorption heat pump system (parallel type, series type, and generator type) are carried out by using the computer simulation. These include the calculation of solar energy from the solar collector, and the revision of computer package, developed by Oak Ridge National Laboratory, to predict the annual performance. Finally using weather data and load conditions, the annual performance are obtained. Results show that the annual operating costs of three solar-absorption heat pump systems are almost same values and 44% lower than that of the pure absorption heat pump system. The total annual input energys of solar-absorption heat pump systems are also about 44% lower than that of the pure absorption heat pump. The nominal size of the solar-absorption heat pump systems can be reduced to a value of 55% that of the pure absorption heat pump that would normally be specified under identical conditions.

  • PDF

스크류 형 건식진공펌프 기술 현황 및 응용 (Screw-type Dry Vacuum Pump Technology and Application in Semiconductor Process)

  • 노명근;황태경;박제우
    • 한국진공학회지
    • /
    • 제17권4호
    • /
    • pp.292-301
    • /
    • 2008
  • 반도체 및 디스플레이 공정과 같이 진공의 높은 청결도의 진공이 필수적으로 요구되어 지는 산업분야가 확대됨에 따라 건식진공펌프의 중요성은 급격히 증대되어 왔다. 다단루츠형 진공펌프와 함께 건식진공펌프 양대 축의 하나를 형성하는 스크류형 건식진공펌프는 공정부산물 발생이 많은 고 난이도 응용분야에서 그 장점을 발휘하여 왔다. 최근 들어 에너지 효율이 획기적으로 개선된 스크류형 건식진공펌프의 개발이 활발히 진행되고 있다. 이 총설논문에서는 스크류형 건식진공펌프의 전반적 기술사항들을 살펴보고 실제 반도체 공정에의 응용 및 스크류형 건식진공펌프의 향후 발전 방향에 대하여 살펴보았다.

미세버블펌프 수치모델평가 및 검증 (Evaluation for the Numerical Model of a Micro-Bubble Pump)

  • 이상문;장춘만
    • 한국수소및신에너지학회논문집
    • /
    • 제27권1호
    • /
    • pp.121-126
    • /
    • 2016
  • Hydraulic performance of a micro-bubble pump has been analyzed by numerical simulation and experimental measurements. Flow recirculation apparatus between the pump inlet and outlet reserviors has been adopted to measure pump performance according to flow conditions sequentially. To analyze three-dimensional flow field in the micro-bubble pump, general analysis code, CFX, is employed. SST turbulence model is employed to estimate the eddy viscosity and compared the pump performance to k-${\varepsilon}$ model. Unstructured grids are used to represent a composite grid system including blade, casing and inlet casing. It is found that the numerical model used in the present study is effective to evaluate the pump performance. From the numerical simulation, low velocity region due to pressure loss is decreased where pump efficiency has maximum value. Detailed flow field inside the micro-bubble pump is also analyzed and compared.

Optimization Design of Stainless Steel Stamping Multistage Pump Based on Orthogonal Test

  • Weidong, Shi;Chuan, Wang;Weigang, Lu;Ling, Zhou;Li, Zhang
    • International Journal of Fluid Machinery and Systems
    • /
    • 제3권4호
    • /
    • pp.309-314
    • /
    • 2010
  • Stainless steel stamping multistage pump has become the mainstream of civil multi-stage pump. Combined with the technological features of stamping and welding pump, the studies of design for hydraulic parts of pump were come out. An $L_{18}$$3^7$)orthogonal experiment was designed with seven factors and three values including blade inlet angle, impeller outer diameter, guide vane blade number, etc. 18 plans were designed. The two stage of whole flow field on stainless steel stamping multistage pump at design point for design was simulated by CFD. According to the test result and optimization design with experimental research, the trends of main parameters which affect hydraulic performance were got. After being manufactured and tested, the efficiency of the optimal model pump reaches 61.36% and the single head is more than 4.8 m. Compared with the standard efficiency of 53%, the design of the stainless steel stamping pump is successful. The result would be instructive to the design of Stainless steel stamping multistage pump designed by the impeller head maximum approach.

외기온 변화에 따른 공기-공기/공기-물 형태로 된 복합형 열펌프 시스템의 성능 특성 분석 (Performance Analysis of Hybrid Heat Pump System of the Air-to-Air/Air-to-Water with the Ambient Temperature)

  • 송현갑
    • Journal of Biosystems Engineering
    • /
    • 제25권4호
    • /
    • pp.273-278
    • /
    • 2000
  • The hybrid heat pump system of the air to air and / or air to water was composed and its COP was analyzed with the ambient temperature on the opened and closed loop system respectively. The results be indicated by the equation(7) that the COP(Coefficient of Performance) of air-source(air to air and / or air-water) heat pump is effected with the ambient air temperature and AVACTHE.(Automatic Variable Area Capillary Type Heat Exchanger) 2. The COP of air-to-water heat pump without AVACTHE decreased in accordance with the ambient temperature decrease, however in case of the heat pump with AVACTHE the COP was maintained at 2.8∼3.0 level when the ambient temperature decrease from -$5^{\circ}C$ to $-11^{\circ}C$. 3. The COP of the air-to-water heat pump operated on the open loop was higher 40∼58% than that of the heat pump operated on the close loop. 4. The lower ambient temperature air effect on the COP of the air-to-air heat pump operated on the semi closed loop could be controlled using the AVACTHE, and at the high ambient air temperature the COP increased using the Bypass circuit.

  • PDF

지로터 오일 펌프의 성능 향상을 위한 치형의 최적 설계 (Optimal Design of Tooth Profile for High-Efficiency Gerotor Oil Pump)

  • 김재훈;박준홍;정성윤;손진혁;김철
    • 한국정밀공학회지
    • /
    • 제22권5호
    • /
    • pp.28-36
    • /
    • 2005
  • A gerotor pump is suitable for oil hydraulics of machine tools, automotive engines, compressors, constructions and other various applications, which are highly accepted by designers. Especially the pump is an essential machine element of an automotive engine to feed lubricant oil. However, related industries do not have necessary technology to design and optimize the pump and paid royalties of rotor profile on an advanced country. Also, gerotor pumps with unsettled design parameters have not been sufficiently analyzed from a theoretical view of design. Therefore, it is still very difficult for the pump designer and manufacturer to decide the specifications for the required gerotor pump by users. In this study, the design optimization has been carried out to determine the design parameters that maximize the specific flow rate and minimize the flow rate irregularity. Theoretical analyses and optimal design of the gerotor oil pump have been performed by mathematical base, numerical method and knowledge of kinematics. An automated design system of the tooth profile has been developed through Auto LISP language and CAD method considering various design parameters. Finally, an optimally designed model for a general type of a gerotor pump has been generated and experimentally verified for the pump performances.

Numerical analysis of the temperature distribution of the EM pump for the sodium thermo-hydraulic test loop of the GenIV PGSFR

  • Kwak, Jaesik;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • 제53권5호
    • /
    • pp.1429-1435
    • /
    • 2021
  • The temperature distribution of an electromagnetic pump was analyzed with a flow rate of 1380 L/min and a pressure of 4 bar designed for the sodium thermo-hydraulic test in the Sodium Test Loop for Safety Simulation and Assessment-Phase 1 (STELLA-1). The electromagnetic pump was used for the circulation of the liquid sodium coolant in the Intermediate Heat Transport System (IHTS) of the Prototype Gen-IV Sodium-cooled Fast Reactor (PGSFR) with an electric power of 150 MWe. The temperature distribution of the components of the electromagnetic pump was numerically analyzed to prevent functional degradation in the high temperature environment during pump operation. The heat transfer was numerically calculated using ANSYS Fluent for prediction of the temperature distribution in the excited coils, the electromagnet core, and the liquid sodium flow channel of the electromagnetic pump. The temperature distribution of operating electromagnetic pump was compared with cooling of natural and forced air circulation. The temperature in the coil, the core and the flow gap in the two conditions, natural circulation and forced circulation, were compared. The electromagnetic pump with cooling of forced circulation had better efficiency than natural circulation even considering consumption of the input power for the air blower. Accordingly, this study judged that forced cooling is good for both maintenance and efficiency of the electromagnetic pump.

Design of charge pump circuit for analog memory with single poly structure in sensor processing using neural networks

  • Chai, Yong-Yoong;Jung, Eun-Hwa
    • 센서학회지
    • /
    • 제12권1호
    • /
    • pp.51-56
    • /
    • 2003
  • We describe a charge pump circuit using VCO (voltage controlled oscillator) for storing information into local memories in neural networks. The VCO is used for adjusting the output voltage of the charge pump to the reference voltage and for reducing the fluctuation generated by the clocking scheme. The charge pump circuit is simulated by using Hynix 0.35um CMOS process parameters. The proposed charge pump operates properly regardless to the temperature and the supply voltage variation.

인버터 적용 펌프모타의 부하운전별 진동해석 (Analysis of Vibration of apply to drive pump with inverter)

  • 황진열;김기원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1131-1132
    • /
    • 2011
  • For the purpose to flow control of pump in booster pump station, nonlinear-load inverter equipment is being introduced. While inverter equipment has the advantage of power-ratio savings and volume control, due to the vibration of pump and motor, secondary breakdown may occur Purpose in this paper is reliable facility operation by providing optimal operationg standards through vibration analysis of apply to drive pump with inverter in long-term in booster pump station.

  • PDF