• 제목/요약/키워드: Pump

검색결과 6,421건 처리시간 0.028초

펌프의 저 유량 운전특성에 관한 실험적 연구 (An Experimental Study on the Pump Operating Characteristics with Low Flow Operation)

  • 오광석;신필권;박종호;심우건;조두연
    • 소음진동
    • /
    • 제9권1호
    • /
    • pp.85-96
    • /
    • 1999
  • For ASME Code pumps in nuclear power plants, inservice test is required to assess the operational readiness in accordance with ASME code and related regulations. The objective of this study therefore, is to develop the technical background of the degradation of pump performances and conditions due to low flow rate operation. In addition. the detection techniques of pump operating conditions are to be developed to enhance the safety and economy of nuclear power plants. A test loop consisted of pump, motor. water tank, flow rate measurements and piping system with flow control devices was established for this study. Two typical pumps, 1-stage volute pump and 3-stage turbine pump, were selected and the test was performed upon two major point of views ; i.e., pump discharge pressure pulsations analysis and pump vibration spectrum analysis. From the test results, it is concluded that (1) the pump vibration affected by the natural frequency of operating pump is significant in the low frequency zone (around 1 Hz) : the vibration amplitude. especially. is an important factor during low flow rate operation. and shall be monitored to ensure that it is within the limit of ASME OM code Part 6, (2) the vibration frequency and pump discharge pressure are affected by vane pass frequency and running speed, (3) the wave phenomena due to the compressiblity of water is anticipated during low flow rate operation. and the pump system shall be designed to prevent it and. finally, (4) the technical background of the degradation of pump performances and conditions due to low flow rate operation is provided.

  • PDF

소독능을 고려한 송수펌프 최적운영기법 개발 (Development of the method for optimal water supply pump operation considering disinfection performance)

  • 형진석;김기범;서지원;김태현;구자용
    • 상하수도학회지
    • /
    • 제32권5호
    • /
    • pp.421-434
    • /
    • 2018
  • Water supply/intake pumps operation use 70~80% of power costs in water treatment plants. In the water treatment plant, seasonal and hourly differential electricity rates are applied, so proper pump scheduling can yield power cost savings. Accordingly, the purpose of this study was to develop an optimal water supply pump scheduling scheme. An optimal operation method of water supply pumps by using genetic algorithm was developed. Also, a method to minimize power cost for water supply pump operation based on pump performance derived from the thermodynamic pump efficiency measurement method was proposed. Water level constraints to provide sufficient disinfection performance in a clearwell and reservoirs were calibrated. In addition, continuous operation time constraints were calibrated to prevent frequent pump switching. As a result of optimization, savings ratios during 7 days in winter and summer were 4.5% and 5.1%, respectively. In this study, the method for optimal water pump operation was developed to secure disinfection performance in the clearwell and to save power cost. It is expected that it will be used as a more advanced optimal water pump operation method through further studies such as water demand forecasting and efficiency according to pump combination.

CMOS 이미지 센서를 위한 고효율 Charge Pump (High-Efficiency Charge Pump for CMOS Image Sensor)

  • 김주하;전영현;공배선
    • 대한전자공학회논문지SD
    • /
    • 제45권5호
    • /
    • pp.50-57
    • /
    • 2008
  • 본 논문에서는 CMOS image sensor(CIS)에서 사용될 수 있는 고 효율 charge pump를 제안하였다. 제안된 charge pump는 CIS의 동작 특성을 활용하여 switching loss 및 reversion loss를 최소화하여 고 효율 동작을 실현하였다. 즉, CIS 픽셀 동작 구간에 따라 local clock driver, 펌핑 커패시터, 그리고 charge 전달 switch의 크기를 역동적으로 조절함으로써 switching loss 를 최소화하였다. 또한, schmitt trigger를 채용한 tri-state local clock driver를 이용하여 non-overlapping 구간이 충분히 확보된 local clock을 공급할 수 있게 함으로써 reversion loss를 최소화하였다. 0.13-um CMOS 공정을 이용한 시뮬레이션 비교 결과, 제안된 charge pump는 구동 전류가 없는 조건에서 기존 구조에 비해 최대 49.1% 전력 소모를 개선하였으며, 구동 전류가 최대인 조건에서는 19.0% 전력 소모를 개선할 수 있었음을 확인하였다.

건물 특성에 따른 냉수 순환 펌핑 시스템 별 에너지 소모량 분석 (Energy Consumption Evaluation in Pumping System with Different Building Characteristics)

  • 신동신;박성빈;전태익;마강일;김태홍;이성구
    • 설비공학논문집
    • /
    • 제28권6호
    • /
    • pp.242-247
    • /
    • 2016
  • This study analyzed the energy consumption of a building pump system that was originally equipped with a primary-secondary zone pump system. Using the HYSYS program the energy consumption of the primary pump system was compared with the primary-secondary zone pump system. The primary-secondary zone pump system consumes less energy than the originally designed primary pump system. When the distance between the machine room and each building is assumed to be equal, the primary pump system can be more efficient than the primary-secondary zone pump system with decreasing the distance. When the distance is 120 m, the primary system consumes less total annual energy than the primary-secondary zone pump system and saves 2,773 kWh. The suggested energy evaluation program can be useful if the designer seeks a more efficient pump system.

Vacuum system design of a 10 ton/day class air liquefaction cold box for liquid air energy storage

  • Sehwan, In;Juwon, Kim;Junyoung, Park;Seong-Je, Park;Jiho, Park;Junseok, Ko;Hankil, Yeom;Hyobong, Kim;Sangyoon, Chu;Jongwoo, Kim;Yong-Ju, Hong
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제24권4호
    • /
    • pp.65-70
    • /
    • 2022
  • A vacuum system is designed for thermal insulation of a 10 ton/day class air liquefaction cold box for liquid air energy storage. The vacuum system is composed of a turbomolecular pump, a backing pump and vacuum piping for the vacuum pumps. The turbomolecular pump is in combination with the backing pump for pumping capacity. The vacuum piping is designed with system installation conditions, such as distance from the cold box, connections to vacuum pumps and installation space. The capacity of the vacuum pump combination, namely pumping speed, is determined by analysis of the vacuum system, and pump-down time to 1×10-5 mbar is estimated. Vacuum piping conductance, system pumping speed and outgassing rate are calculated for the pump-down time with the ultimate pumping speed range of the vacuum pump combination of 1400 - 2300 l/s. Although the pump-down time gets shorter by larger capacity vacuum pumps, it mainly depends on target vacuum degree and outgassing rate in the cold box. The pump-down time is estimated as 3 - 6 hours appropriate for cold box operation for the pumping speed range. Considering the outgassing rate has uncertainty, the vacuum pump combination with pumping speed of 1900 l/s is chosen for the vacuum system, which is middle value of the pumping speed range.

DME를 연료로 하는 고압펌프의 성능 및 내열 특성 평가 (Performance and Thermal Endurance Tests of a High Pressure Pump Fueled with DME)

  • 백범기;임옥택
    • 한국수소및신에너지학회논문집
    • /
    • 제31권1호
    • /
    • pp.89-95
    • /
    • 2020
  • The main scope of this paper is to see if the conventional pump can be properly used for a specific fuel, Di-methyl Ether (DME) despite of its low lubricity and high reactivity in the experimental conditions. A wobble plate type fuel pump was connected to the common rail to verify that the pump could deliver the fuel at the required pressure and resultantly DME could be used as fuel without modifying the original pump. At each required pressure (30 Mpa, 35 Mpa, 40 Mpa, 45 Mpa, and 50 Mpa), the pump met the pressure required by the common rail. In addition, pump performance experiments tended to follow the usual performance curve while the flow rate decreased as the pressure increased. The maximum flow rate of the pump was 470 kg/h at 30 Mpa and all measurements were taken with keeping DME temperature below 60℃.

액체로켓엔진용 산화제펌프 회전체의 하중 예측 (Thrust Estimation Acting on Rotor of LOX Pump for Liquid Rocket Engine)

  • 김대진;최창호
    • 한국추진공학회지
    • /
    • 제19권6호
    • /
    • pp.98-104
    • /
    • 2015
  • 회전체의 과도한 하중은 펌프의 손상이나 수명 감소의 원인이 된다. 이에 액체로켓엔진용 산화제펌프의 안정성 확보를 위해 펌프 회전체에 작용하는 하중을 상사 시험을 통해 예측하였다. 축방향 하중은 펌프 외부에 설치된 축추력 측정 장치를 통해 간접적으로 계측하였으며, 반경방향 하중은 볼류트의 압력 분포를 토대로 계산하였다. 그 결과, 펌프의 유량이 작을수록 축방향 하중과 반경방향 하중 모두 증가하는 것으로 확인되었다. 그러나, 하중의 크기가 크지 않아 펌프의 안정성에 영향을 끼치지 않을 것으로 예측되었다.

Mouse 미수정란에서의 electrogenic Na pump 활동여부에 관한 연구 (Electrophysiological study on the presence of the electrogenic Na pump of the mouse unfertilized eggs)

  • 홍성근
    • 대한수의학회지
    • /
    • 제29권3호
    • /
    • pp.245-251
    • /
    • 1989
  • In order to manifest the presence of Na-K pump and its property on the unfertilized egg membranes of mouse, membrane potential was recorded under the physiological condition (at $37^{\circ}C$ and 4mM $Ca^{2+}$). After an induction of superovulation, the fresh eggs with zona pellucida were collected from mouse oviduct. Transient hyperpolarization as pump action was recorded after the switch into the high potassium perfusate (15mM $K^+$) from K-free perfusate, and the difference between membrane potential observed just before the perfusion of high potassium solution and the maximal membrane potenlial during the perfusion of high potassium solution was regard as pump activities. The results observed were as follows, 1. Resting mombrane potential was depolarized under the treatment of $10^{-5}M$ ouabain. 2. Pump activities of the unfertilized mouse eggs were $-3.38{\pm}0.61mV$ ($Mean{\pm}SD$, n=6), recorded as transient hyperpolarization due to the electrogenic property. 3. Pump activities were blocked by both treatment of $10^{-5}M$ ouabain and perfusion of Nafree solution, while increased by high $Na^+$ (300mM) perfusion ($-7.45{\pm}0.75mV$, n =2). 4. Hyperpolarization due to pump activity was not altered by $Mn^{2+}$. 5. Above results confirm the presence of ouabain-sensitive Na-K pump, which affected the membrane potential directly, on the unfertilized egg membranes of mouse.

  • PDF

광역상수도용 펌프의 최적결정을 위한 펌프/모터 선정 프로그램 개발 (Development of Pump/Motor Selection Program for Optimized Pump Decision of the Regional Water Supply Facilities)

  • 노형운;김재수;박길문;서상호;이영호
    • 한국유체기계학회 논문집
    • /
    • 제4권4호
    • /
    • pp.22-27
    • /
    • 2001
  • The pump/motor selection program for optimized selection of regional water supply facilities was developed based on a flowchart compiled from basic operational data, total head requirement, initial pump/motor specification selection etc. This program was developed in Visual Basic. The program accepts, as in the flowchart, operational requirements of pumps and other system requirements, and calculates specific speed based on flow rate, total head and rotational speed. Then the calculated specific speed is used to select pump types and speed prior to determining likelihood of cavitation occurring at the calculated NPSH. Power requirement is then calculated for safe operation of pump to assist final pump selection. Test results of the program match very closely to the design values of Paldang intake pump station(3rd stage) proving that the program can be used as an effective and practical aid for designing new regional water supply systems.

  • PDF

광역상수도용 펌프의 최적결정을 위한 펌프/모터 선정 프로그램 개발 (Development of Pump/Motor Selection Program for Optimized Pump Decision of the Regional Water Supply Facilities)

  • 노형운;김재수;박길문;서상호;이영호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.171-176
    • /
    • 2001
  • The Pump/Motor Selection Program for optimized selection of regional water supply facilities was developed based on a flowchart compiled from basic operational data, total head requirement, initial pump/motor specification selection etc.. This program was developed in Visual Basic. The program accepts, as in the flowchart, operational requirements of pumps and other system requirements and calculates specific speed based on flow rate, total head and na Then the calculated specific speed is used to select pump types and rpm Prior to determining likelihood of cavitation occurring at the calculated NPSH. Power requirement is then calculated for safe operation of pump to assist final pump selection. Test results of the program matches very closely to the design values of Paldang intake pump station(3rd stage) proving that the program can be used as an effective and practical aid for designing new regional water supply systems.

  • PDF