• Title/Summary/Keyword: Pulsed YAG Laser

Search Result 298, Processing Time 0.026 seconds

Enhancement of the ferroelectric properties of $Pb(Zr,Ti)O_3$ thin films with $Pb(La,Ti)O_3$ buffers fabricated by pulsed laser deposition (PLT buffer층의 삽입에 따른 강유전 PZT박막의 특성 향상)

  • Lim, Sung-Hoon;Lee, Eun-Sun;Chung, Hyun-Woo;Lee, Sang-Yeol
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.67-69
    • /
    • 2004
  • The $Pb(Zr,Ti)O_3$ thin films were fabricated with $Pb(La,Ti)O_3$ buffers in-situ onto $Pt/Ti/SiO_2/Si$ substrates by pulsed laser deposition technique using a Nd:YAG laser with energy density of $2.5J/cm^2$, and deposited for 10 minutes at $550^{\circ}C$ of substrate temperature. And then, the films have been annealed at $550^{\circ}C$ in oxygen ambient pressure. The remanent polarization value is increased by using buffer layers but coercive field of films is slightly increased.

  • PDF

A Case Report on the Treatment of Cyclosporin-A Induced Gingival Enlargement in Renal Transplant Patient (신장이식 환자에 있어서 Cyclosporin-A에 의한 치은비대의 치험례)

  • 장성용
    • Journal of Oral Medicine and Pain
    • /
    • v.23 no.2
    • /
    • pp.119-125
    • /
    • 1998
  • The authors treated a 58-year old female patient who had come to the Department of Oral Medicine, KNUH due to the chief complaints of gingival enlargement and bleeding on the upper and lower jaw. The lesions were diagnosed as cyclosporin-A induced gingival enlargement by patient's history and clinical examination. The patient was treated with gingivectomy using pulsed Nd:YAG laser. After gingivectomy the wound was compressed with 0.1% chlorhexidine-soaked gauze to prevent relapse of the lesion. Good healing process was observed and there were no recurrences until 3-month follow-up visit. From the results of this clinical trial it was suggested that a pulsed Nd:YAG laser gingivectomy would be helpful for the treatment of cyclosporin-A induced gingival enlargement in renal transplant patients.

  • PDF

The effects of EDTA and pulsed Nd:YAG laser on apical leakage of canal obturation

  • Kwon, Jin-Soo;Lee, Hee-Joo;Hur, Bock
    • Proceedings of the KACD Conference
    • /
    • 2001.11a
    • /
    • pp.563.1-563
    • /
    • 2001
  • The purpose of this study was to evaluate the effects of EDTA and pulsed Nd:YAG laser on apical of canal obturation. Forty-eight single-rooted teeth were used in thes study. The teeth were instrumented up to a size 40 K-file and irrigated with 2.5% NaOCl between each file size. And the teeth were divided into 4 groups. In group A, the root canals were irrigated with a final flush of 5ml 2.5% NaOCl as a control group.(omitted)

  • PDF

Nanoparticle Synthesis by Pulsed Laser Ablation of Consolidated Microparticles (압밀 금속 마이크로 입자의 펄스 레이저 ABLATION에 의한 나노입자 합성)

  • 장덕석;오부국;김동식
    • Laser Solutions
    • /
    • v.5 no.2
    • /
    • pp.31-38
    • /
    • 2002
  • This paper describes the process of nanoparticle synthesis by laser ablation of consolidated microparticles. We have generated nanoparticles by high-power pulsed laser ablation of Al, Cu and Ag microparticles using a Q-switched Nd:YAG laser (wavelength 355 nm, FWHM 5 ㎱, fluence 0.8∼2.0 J/㎠). Microparticles of mean diameter 18∼80 ㎛ are ablated in the ambient air The generated nanoparticles are collected on a glass substrate and the size distribution and morphology are examined using a scanning electron microscope and a transmission electron microscope. The effect of laser fluence and collector position on the distribution of particle size is investigated. The dynamics of ablation plume and shock wave is analyzed by monitoring the photoacoustic probe-beam deflection signal. Nanosecond time-resolved images of the ablation process are also obtained by laser flash shadowgraphy. Based on the experimental results, discussions are made on the dynamics of ablation plume.

  • PDF

Effects of Pulsed Nd:YAG Laser Irradiation and Fluoride Compound Applicatin on Acid Resistance of Bovine Teeth (Pulsed Nd:YAG 레이저 조사와 불소화합물 도포가 치아 내산성에 미치는 영향)

  • An-Hee Lee;Woo-Cheon Kee
    • Journal of Oral Medicine and Pain
    • /
    • v.20 no.2
    • /
    • pp.429-447
    • /
    • 1995
  • This study was designed to determine the most effective concentration of fluoride and levels of laser irradiation for the remineralization of decayed teeth. After irradiation with a pulsed Nd:YAG laser and the topical application of fluoride, phosphate and fluoride concentration in enamel were measured. And then the changes on surface enamel using an scanning electron microscope were observed. Samples by extraction healthy, permanent, mandibular bovine teeth with no caries were obtained. Among them 371 healthy samples were selected and artificial carious lesions were made. 20 samples were assigned to each experimental group. After irradiation with a pulsed Nd:YAG laser with total energy densities of 10J/$\textrm{cm}^2$, 20J/$\textrm{cm}^2$ for each group. On the teeth, 2% NaF, 1.9% NH4F, 1.6% TiF4 Elmex gel(amine fluoride) and 1.23% APF gel were applied. After pH circulatory procedures, concentrations of fluoride with and Ionalyzer (Orion Research, Model 901, USA) and phosphates with an Uv/V is spectrophotometer (Uvikon 860, Kontrom Co, Switzerland) were measured. By etching the teeth in layers and measuring fluoride concentrations, a profile of fluoride penetration according to depth could be developed. And also the changes on the surface of the enamel using an electron scanning microscope were observed. The comparative analysis yielded the following results : 1. Phosphate concentration was low in all groups compared with the control group except for teeth treated Elmex gel, irradiated with 10J/$\textrm{cm}^2$ and 30J/$\textrm{cm}^2$ energy densities. Teeth treated with APF gel and 30J/$\textrm{cm}^2$ irradiation gad the lowest phosphate concentration. 2. Among all groups, fluoride concentrations in tooth enamel were highest in APF gel and NaF groups irradiated at 30J/$\textrm{cm}^2$. The APF gel group had the highest fluoride concentrations across all energy densities. 3. In the APF gel group, and the NaF group, the greater the energy density of the laser, the higher the fluoride concentrations in the enamel. 4. In all groups, the concentration of fluoride in the enamel by depth tended to decrease with depth. 5. Under the scanning electron microscope, under the condition of irradiation with 20J/$\textrm{cm}^2$, enamel crack was detected for the first time. In the NH4F group, spherical deposits were found on the surface of the enamel, and in the TiF4 group the surface of enamel was covered with an irregular, thin membranous mass in places. In the APF gel and NaF groups irradiated with 10J/$\textrm{cm}^2$, spherical and irregular particles covered the teeth. When these groups were irradiated at 20J/cm2, they were covered with amorphous crystals. These results suggest that one could obtain more effective anticariogenic effects without damage to teeth when less than 20J/$\textrm{cm}^2$ energy densities and APF gel are used.

  • PDF

A Design and Implement of the Medical Nd:YAG Laser Firmware under in ZCC method

  • Kim, Whi-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.40.3-40
    • /
    • 2001
  • The pulsed Nd:YAG laser is the most commonly used type of solid-state laser in many fields. In material processing and medical treatment, the power density control of a laser beam Considered to be significant, which depends on the flashlamp current pulse width and pulse repetition rate. For general laser power supply to control the laser power density, the secondary of the power transformer is connected to the rectifier and filter capacitor. The output of a rectifier is applied to a switching element in the secondary of the transformer. So power supply is complicated and the loss of switching is considerably. In addition, according to increasing pulse repetition rate, charged energy of energy-storage capacitor bank is not transferred sufficiently to flashlamp, and laser output efficiency decreases. In this study, we have ...

  • PDF

Weldability of Pure Titanium Thin plate for LPG Re-Condenser by Nd:YAG Laser - Physical Constant and Welding Parameter - (LPG 재응축기용 순티타늄 박판의 Nd:YAG 레이저 용접성(I) - 순티타늄의 물성과 용접변수 -)

  • Kim, Jong-Do;Gwak, Myeong-Seop;Lee, Chang-Je;Kim, Chang-Su
    • Proceedings of the KWS Conference
    • /
    • 2007.11a
    • /
    • pp.363-365
    • /
    • 2007
  • Titanium and its alloys have excellent corrosion resistance, high strength to weight ratios and high temperature creep properties, which make them using many various fields of application. Responding to these needs, welding processes for titanium are also being used including TIG, MIG, resistance welding, plasma arc welding, diffusion welding, electron beam welding and laser welding. In this study, It is possible to get sound beads without humping bead and spatter with the decrease of peak power according to increase of pulse width and change of welding speed for heat input control at pulsed Nd:YAG laser welding of titanium plates for Lap welding.

  • PDF

Output characteristics of a pulsed Ti:sapphire laser (펄스동작 Ti : sapphire 레이저의 출력특성)

  • 김병태;이형권
    • Korean Journal of Optics and Photonics
    • /
    • v.7 no.4
    • /
    • pp.390-396
    • /
    • 1996
  • A pulsed Ti : sapphire laser with a Z-folded cavity, which was pumped by a frequency-doubled Nd : YAG laser, was developed. A laser output energy of 822 $\mu$J with a pulsewidth of 5 ns and an output efficiency of 27.4% was obtained at a center wavelength of 790 nm using an output coupler of 18% reflectance. The slope efficiency was 35%. The output beam diameter was 0.9 mm, and the divergence angle was 1.8 mrad. The spectrum tunability was about 120 nm from 740 nm to 860 nm with a FWHM of 90 nm at an 18% output coupler and a pumping energy of 3 mJ.

  • PDF

C-Ring Stress Corrosion Test for Inconel 600 Tube and Inconel 690 welded by Nd:YAG Laser (Nd:YAG 레이저로 용접한 인코넬 600관과 인코넬 690의 C링 응력 부식시험)

  • 김재도;문주홍;정진만;김철중
    • Proceedings of the KWS Conference
    • /
    • 1998.10a
    • /
    • pp.288-291
    • /
    • 1998
  • Inconel 600 alloy is used as the material of nuclear steam generator tubing because of its mechanical properties, formability, and corrosion properties. According to reports, the life time of nuclear power plants decreases because of the pitting, intergranular attack, primary water stress corrosion cracking(PWSCC), and intergranular stress corrosion cracking(IGSCC), and denting in the steam generator. The SCC test is very important because of SCC appears in various environment such as solutions, materials, and stress. The C-Rig specimen was made of the steam generator welded sleeve repairing by the pulsed Nd:YAG laser. In the corrosion invironment, corrosion solutions are Primary Water, Caustic, and Sulfate solution and corrosion time is 1624-4877hr. The permitted stress is 30-60ksi.In this C-Ring SCC test is the relationship between corrosion depth, crack and corrosion environment is evaluated. SCC was happens in Sulfate and Corrosion solution but doesn't happen in Primary Water. The corrosion time and stress is very affected by the severely environment of Sulfate or Caustic solution. The microstructure observation indicates that SCC causes interganular failure in the grain boundary of vertical direction.

  • PDF