• Title/Summary/Keyword: Pulsed Ultrasound

Search Result 96, Processing Time 0.021 seconds

A study on the development of Pulsed Doppler System using Auto-Correlation (Auto-Correlation을 이용한 펄스 도플러 시스템에 관한 연구)

  • Lim, Chun-Sung;Rang, Chung-Shin;Lee, Hang-Sei;Kim, Young-Kil
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.705-708
    • /
    • 1988
  • Ultrasound Doppler Diagnostic System utilizes the Doppler effect for measurement of blood velocity. The sign of the Doppler frequency shift represents blood flow direction. Pulsed Doppler System uses Phase detector and zerocrossing method to produce simultaneous independent audio and velocity signals for forward and reverse blood flow direction in the time domain, had been fabricated. But time-domain analyzing such as audio evaluation and zerocrossing detection for instantaneous and mean frequency measurement doesn't, provide both an accurate and quantitative result. Therefore, it is necessary to adopt frequency domain technique to improve system performance. In this paper, we describe a unit which is composed of Pulsed Doppler System and real-time spectrum analyzer (installed TMS 32010 DSP Chip). This unit shows time-dependent spectrum variation and mean velocity of blood Signal.

  • PDF

Treatment Experience of Pulsed Radiofrequency Under Ultrasound Guided to the Trapezius Muscle at Myofascial Pain Syndrome -A Case Report-

  • Park, Chung-Hoon;Lee, Yoon-Woo;Kim, Yong-Chan;Moon, Joo-Hwa;Choi, Jong-Bum
    • The Korean Journal of Pain
    • /
    • v.25 no.1
    • /
    • pp.52-54
    • /
    • 2012
  • Trigger point injection treatment is an effective and widely applied treatment for myofascial pain syndrome. The trapezius muscle frequently causes myofascial pain in neck area. We herein report a case in which direct pulsed radiofrequency (RF) treatment was applied to the trapezius muscle. We observed that the RF treatment produced continuous pain relief when the effective duration of trigger point injection was temporary in myofascial pain.

Pulsed Radiofrequency Ablation Under Ultrasound Guidance for Huge Neuroma

  • Kim, Young Ki;Jung, Il;Lee, Chang Hee;Kim, Se Hun;Kim, Jin Sun;Yoo, Byoung Woo
    • The Korean Journal of Pain
    • /
    • v.27 no.3
    • /
    • pp.290-293
    • /
    • 2014
  • Amputation neuroma can cause very serious, intractable pain. Many treatment modalities are suggested for painful neuroma. Pharmacologic treatment shows a limited effect on eliminating the pain, and surgical treatment has a high recurrence rate. We applied pulsed radiofrequency treatment at the neuroma stalk under ultrasonography guidance. The long-term outcome was very successful, prompting us to report this case.

A Study on the Stationary Canceler in the Ultrasonic Pulse Doppler System (초음파 펄스 도플러 시스템의 Stationary Conceler에 대한 연구)

  • 김영길
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.1
    • /
    • pp.47-54
    • /
    • 1985
  • In this paper, clutter in ultrasound pulsed Doppler system is analyzed mathematically. And stationary canceler which reduce the clutter is designed. The operating characteristics of the stationary canceler is investigated in body (in vivo) by audio signal and spectrum analyzer.

  • PDF

Construction of Ultrasound Pulsed Doppler Velocimeter (펄스 초음파 도플러 속도계의 제작에 관한 연구)

  • 현석봉;김수용;이재수
    • Progress in Medical Physics
    • /
    • v.5 no.1
    • /
    • pp.25-39
    • /
    • 1994
  • To measure the velocity of heart wall and local flow transctaneously in blood vessels, we have developed a single channel 3.1 MHz pulsed ultrasonic Doppler velocity meter. Ultrasound pluse width and repetition frequency (PRF) used in the velocity meter is 1 ${\mu}$sec 6kHz reapectively, and the Doppler shift of the backscattered echo signal is sensed in a phase detector by coherent demodulation method. From the output of the phase detector, the Doppler signal corresponding to the mean velocity of acoustic wave scatterers over a small region is obtained by using a range gate, sample holder and band-pass filter. Mean frequency of Doppler signal is estimated by zero-crossing counter and the instantaneous velocity of scatters is displayed as a function of time. It is possible to estimate velocity profile, volume flow and flow acceleration of vessels in man if the number of channels and range resolution in increased.

  • PDF

Portal blood flow measurement by doppler ultrasonography in dogs (도플러 초음파를 이용한 개의 간혈액량의 측정)

  • Sung, Jai-ki;Lee, Young-won;Lee, Hee-chon;An, Yong-ju;Choi, Ho-jung;Yoon, Jung-hee
    • Korean Journal of Veterinary Research
    • /
    • v.37 no.3
    • /
    • pp.661-668
    • /
    • 1997
  • Portal blood flow was measured with pulsed doppler ultrasound in thirty normal dogs. In normal dogs, the average portal blood flow velocity was $17.03{\pm}1.75cm/sec$ and the average portal blood flow was $41.59{\pm}10.10ml/min/kg$. The incident angle between the doppler beam and the portal vein averaged $65^{\circ}$. The average portal vein sectional area was $0.41{\pm}0.14cm^2$. The Congestion index was $0.0245{\pm}0.0081cm{\cdot}sec$. Conclusively, the spectral doppler ultrasonography was quick, non-invasive and simple diagnostic method in circulatory disorders of liver.

  • PDF

The effects of therapeutic ultrasound stimulation on the inflammation cytokine in rat articular chondrocytes

  • Kim, Eun-Jung;Hwang, Sujin;Kim, Gye-Yeop
    • Physical Therapy Rehabilitation Science
    • /
    • v.2 no.1
    • /
    • pp.21-26
    • /
    • 2013
  • Objective: The aim of this study was to investigate the effect of therapeutic ultrasound (US) of cell viability and inflammatory cytokine in rat articular chondrocyte cultures stimulated with lipopolysaccharide (LPS). Design: One group pretest-posttest design. Methods: Cultured chondrocytes were treated with US and/or LPS and assessed for viability, Tumor necrosis factor $(TNF)-{\alpha}$ and Interleukin (IL)-1 production. Results: Oxidative stress was induced in rat chondrocytes with LPS. The cell viability was decreased in chondrocytes after treatment with LPS. The viability revealed that low-intensity pulsed ultrasound (LIPUS) exerted no significant cytotoxicity in the rat chondrocyte. LIPUS inhibited decreased cell viability in the presence of LPS ($30{\mu}g/ml$) in a intensity dependent pattern at LIPUS (p<0.05). $TNF-{\alpha}$ production in the presence of LPS was also inhibited in a dose dependent manner (p<0.05 from $30mW/cm^2$). IL-1 production in the presence of LPS was inhibited as well (p<0.05 from $7.5mW/cm^2$). Conclusions: Our results demonstrate that US was the anti-inflammatory effect of chondrocytes. LIPUS may exert its anti inflammatory effects through inhibition of $TNF-{\alpha}$ and IL-1 synthesis. These results suggest that US have potential for use as a pain relief and reduce the articular destruction.

  • PDF

Effect of low intensity pulsed ultrasound in activating the mitogen-activated protein kinase signaling pathway and inhibition inflammation cytokine synthesis in chondrocytes

  • Kim, Eun-Jung;Kim, Gye-Yeop
    • Physical Therapy Rehabilitation Science
    • /
    • v.3 no.1
    • /
    • pp.33-37
    • /
    • 2014
  • Objective: Low intensity pulsed ultrasound (LIPUS) has been shown to accelerate cell proliferation and tissue healing in both animal models and clinical trials. However, details of the clinical effects of LIPUS have not been well characterized. The aim of this study was to investigate the effect of LIPUS on mitogen-activated protein kinase (MAPK) activation in rat articular chondrocytes. Design: Cross-sectional study. Methods: Chondrocyte were cultured in six well cell culture plates for 72 hours at $37^{\circ}C$ with 5% $CO_2$, and then exposed to LIPUS at 1.5 MHz frequency and $30-mW/cm^2$ power. Changes in chondrocyte activities were evaluated in response to oxydative stress in dose-dependent (0 and 300 uM) and time-dependent (0-24 hr) manner. The cell viability were analyzed using MTT [3-(4.5-dimethylthiazol-2-yl)-2.5 diphenyltetrazolium bromide]. The expression of p38 MAPK was measured using western blotting. Results: Oxidative stress was induced in rat chondrocytes using hydrogen peroxide ($H_2O_2$). The cell viability was decreased in chondrocytes after the $H_2O_2$ dose and time-dependent treatment. The p38 MAPK phosphorylation occurred at a significantly increased rate after $H_2O_2$ treated (p<0.05). Expression of p38 MAPK was decreased in the p38 inhibitor groups compared with the oxidative stress-induced chondrocyte damage via the p38 MAPK signaling pathways (p<0.05). Conclusions: It could be concluded that LIPUS can inhibit oxidative stress-induced chondrocyte damage via the p38 MAPK signaling pathways.

Transdermal Delivery and Analgesic Effects of Lidocaine Hydrogel by Phonophoresis (초음파를 이용한 리도카인 수용성겔의 경피흡수 및 진통효과)

  • Yang, Jae-Heon;Kim, Dae-Keun;Song, Kyung-Suk;Yun, Mi-Young;Ahn, Hyo-Cho;Kim, Young-Il;Kim, Tae-Youl
    • Journal of Pharmaceutical Investigation
    • /
    • v.37 no.3
    • /
    • pp.149-158
    • /
    • 2007
  • To investigate the permeability of lidocaine, percutaneous absorption studies were performed using excised hairless mouse skin and the penetration of lidocaine via the skin was determined. To increase the skin permeation of lidocine, the effects of $Labrasol^{(R)}$, $Labrafil^{(R)}$, $Labrafac^{(R)}$ and $Transcutol^{(R)}$ were investigated. The skin permeation of lidocaine was increased when $Labrasol^{(R)}$ and $Transcutol^{(R)}$ were used as permeation enhancer. To evaluate the influence of ultrasound, various factors such as application modes (continuous mode and pulsed mode), frequency (1.0 and 3.0 MHz) and intensity (1.0, 1.5 and 2.0 w/$cm^2$) were investigated with lidocaine hydrogel. The pronounced effect of ultrasound on the skin permeation of lidocaine was observed at all ultrasound energy levels. The influence of frequency having an effect on skin permeation rate was higher in the case of using 1 MHz, 2.0 w/$cm^2$ and continuous treatment. As the intensity of ultrasound increased, the permeation of lidocaine was accelerated. The in vivo anesthetic effects were evaluated by two aspects as mechanical threshold and electrical threshold. Six healthy volunteers consented to the randomized, double-blind, and cross-over designed study in each group. In each subject, 3 groups were adapted such as K group (ultrasound with gel base only), L group (lidocaine gel) and B group (ultrasound with lidocaine gel). In conclusion, lidocaine was potent anesthetic which could be block pain threshold effectively. And ultrasound could accelerate the skin penetration of lidocaine. The phonophoretic delivery system could be a good candidate for lidocaine as a local anaesthetic to improve the skin permeation and in vivo anaesthetic effect.

A New Mean Frequency Extension Method in Doppler System (초음파 도플러 시스템에서 새로운 평균 주파수 확장 방법)

  • 백광렬
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.183-190
    • /
    • 1995
  • The use of ultrasound pulsed Doppler systems has become increasingly popular due to the advantages of easy measurements of blood velocity, volume blood blow, and irregularities of the circulatory system. However, the 2-D Doppler systems have several problems, such as range ambiguity, low signal to noise ratio, and slow frame rate. The mean frequency aliasing problem originating from the pulse repetition frequency is one of major limitations in pulsed Doppler systems. A conventional approach to resolve this problem is tracking the mean frequency close to and beyond the Nyquist frequency along the temporal axis. In this paper, a new concept of tracking the mean frequency along the spatial axis is proposed. The proposed technique is fault tolerant by nature and more suitable for multi gate and 2-D Doppler system than conventional methods.

  • PDF