• 제목/요약/키워드: Pulse-Diagnosis Data

검색결과 118건 처리시간 0.035초

Array-Based Real-Time Ultrasound and Photoacoustic Ocular Imaging

  • Nam, Seung Yun;Emelianov, Stanislav Y.
    • Journal of the Optical Society of Korea
    • /
    • 제18권2호
    • /
    • pp.151-155
    • /
    • 2014
  • Although various ophthalmic imaging methods, including fundus photography and optical coherence tomography, have been applied for effective diagnosis of ocular diseases with high spatial resolution, most of them are limited by shallow imaging penetration depth and a narrow field of view. Also, many of those imaging modalities are optimized to provide microscopic anatomical information, while functional or cellular information is lacking. Compared to other ocular imaging modalities, photoacoustic imaging can achieve relatively deep penetration depth and provide more detailed functional and cellular data based on photoacoustic signal generation from endogenous contrast agents such as hemoglobin and melanin. In this paper, array-based ultrasound and photoacoustic imaging was demonstrated to visualize pigmentation in the eye as well as overall ocular structure. Fresh porcine eyes were visualized using a real-time ultrasound micro-imaging system and an imaging probe supporting laser pulse delivery. In addition, limited photoacoustic imaging field of view was improved by an imaging probe tilting method, enabling visualization of most regions of the retina covered in the ultrasound imaging.

6.6kV 회전기 고정자 권선에서 부분방전 진단을 위한 평판 안테나 센서 설계 (The Design of a Planar Antenna Sensor for Partial Discharge diagnosis in 6.6kV Rotary Machine Stator Windings)

  • 임광진;키아우소륀;신동훈;박노준;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.222-223
    • /
    • 2007
  • In 6.6kV Rotary Machine Stator Windings, Corona Discharge, Discharge at Conductor Surface, Slot Discharge and Endwinding Discharge is happended by electronic degradation. Also, if Partial Discharge cause in inner-part of Rotary Machine Stator Windings, it will be happended voltage and current pulse. In case of discharge spark, RF electromagnetic wave, which tranmits at discharge position, can happen. To detect this kind of RF electromagnetic wave efficiently, we have designed Planar Antenna Sensor with the CST MWS simulation program. Also we have confined the application possibility, which can analize the partial discharge in Rotary Machine Stator Windings. In the Future, sample of planar antenna sensor will be able to compare with the data of simulation by CST MWS program.

  • PDF

고지방식이 유도성 지방간 쥐 모델에서 간의 자기공명분광 분석을 이용한 지질 양성자 조성 변화 연구 (The Study of Lipid Proton Composition Change in a Rat Model of High Fat Diet Induced Fatty Liver by Magnetic Resonance Spectroscopy Analysis)

  • 김상혁;유승만
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권4호
    • /
    • pp.315-325
    • /
    • 2021
  • The purpose of this study is to investigate the changes in lipid proton (LP) composition according to the induced obese fatty liver and to use it as basic data for treatment and diagnosis of fatty liver in the future. The phantom study was conducted to identify differences between STEAM and PRESS Pulse sequences in LP concentration. A high-fat diet (60%) was administered to eight Sprague-Dawley rats to induce obesity and fatty liver disease. Baseline magnetic resonance imaging /spectroscopy data were obtained prior to the introduction of high-fat diet, and data acquisition experiments were performed after eight weeks using procedures identical to those used for baseline studies. The six lipid proton metabolites were calculated using LCModel software. The correlation between the fat percentage and each LP, revealed that the methylene protons at 1.3 ppm showed the highest positive correlation. The α-methylene protons to carboxyl and diallylic protons showed negative correlation with fat percentage. The methylene proton showed the highest increase in the LP; however, it constituted only 71.86% of the total LP concentration. The methylene proton plays a leading role in fat accumulation in liver parenchyma.

중년 성인남녀의 혈중 지질농도가 가속도맥파에 미치는 영향 (Elevated Levels of Serum Lipids Accelerate Biological Vascular Aging evaluated by the Second Derivative of Photoplethysmogram Waveform in the Middle-Age Adults)

  • 남동현;고형균;박영배
    • Journal of Acupuncture Research
    • /
    • 제19권3호
    • /
    • pp.126-137
    • /
    • 2002
  • Objective : There is accumulating data that cardiovascular diseases, including hypertension, cerebro-vascular accident, coronary heart disease, relate to atherosclerotic changes. Increased serum levels of lipids could play a role in these circumstances. the SDPTG(the second derivative of photoplethysmogram waveform) is noninvasive methods for evaluating the pulse wave and is correlated with age and other risk factors for atherosclerosis. Methods : To study the effects of serum lipid levels on the SDPTG in the middle-age adults, data on serum lipid levels and the SDPTG were collected in 80 healthy middle age with varying serum lipid concentrations. Biological vascular age was assessed using the SDPTG. the SDPTG consists of an a, b, c, and d wave in systole and an e wave in diastole; an SDPTG aging index(Al) was calculated as (b-c-d-e)/a. Results : Serum triglyceride, total cholesterol, total lipid, phospholipid, HDL cholesterol levels were respectively and significantly correlated with SDPTG Al. Serum lipid levels and blood pressure are age-dependent and the SDPTG is blood pressure-dependent. Restricting analysis to age and blood pressure yield strong positive correlations between serum triglyceride, total lipid levels and SDPTG Al, but no correlations between serum total cholesterol, phospholipid levels and SDPTG Al. Conclusion : The results of this study suggest that preventive acupuncture programs or herbal medications for reducing serum lipid, especially triglyceride, levels in middle-age should include a evaluation of biological vascular aging with the second derivative of photoplethysmogram waveform.

  • PDF

마이닝 기반 유비쿼터스 헬스케어 멀티에이전트 시스템 (A Mining-based Healthcare Multi-Agent System in Ubiquitous Environments)

  • 강은영
    • 한국산학기술학회논문지
    • /
    • 제10권9호
    • /
    • pp.2354-2360
    • /
    • 2009
  • 유비쿼터스 컴퓨팅 환경에서 가장 널리 사용 가능한 분야는 헬스케어 분야이다. 본 논문에서는 유비쿼터스 환경에서 마이닝 기반 멀티 에이전트 헬스케어 시스템을 제안한다. 제안하는 기법은 환자의 몸으로부터 생성된 센싱 데이터를 마이닝을 이용하여 진단 패턴을 뽑아내어 정상 상태, 긴급 상태, 응급 상황으로 분류할 수 있다. 이는 실시간으로 센싱되는 엄청난 양의 생체 데이터를 처리할 수 있으며, 환자의 병력 데이터와 비교, 분석한다. 이를 위해 연관 규칙 탐사를 2가지 데이터 그룹으로 구분하여 적용한다. 첫 번째는, 기존의 방대한 의료 병력 데이터로 두 번째는, 체온, 혈압, 맥박등과 같은 센서로부터 센싱한 환자의 실시간 생체데이터로 분류한다. 제안하는 시스템은 PDA 같은 모바일 디바이스 등을 통하여 병원과 멀리 떨어진 지역에서도 긴급 상황을 판단하여 처리할 수 있다. 또한 환자(노인)의 상태를 실시간으로 모니터링 함으로써 요구되는 시간과 비용을 단축하게 되고, 의료 서비스의 지원에 대한 효율성을 높이게 된다.

오행화침법(五行和鍼法)의 이론적 고찰 및 운용 (Theory Study and Work of Ohaeng-Hwa Acupuncture)

  • 심성흠;감철우;김진영;백상인;이병권;손호영
    • Korean Journal of Acupuncture
    • /
    • 제26권4호
    • /
    • pp.119-133
    • /
    • 2009
  • Objectives : The object of this study is to report on the theory of Ohaeng-Hwa Acupuncture Therapy. Methods : The theory of Ohaeng-Hwa Acupuncture Therapy(OHAT; 五行和針法) is a part of the Five Elements Theory unique to Korea. This research Classic of Difficulty Issues-Nan Jing review Ohaeng-Hwa Acupuncture Therapy. Results : OHAT, created and developed by Jae-hoon Song, integrates the victor-vanquished as well as the son-mother relationship of the Five Elements of breakdown and restoration of balance between yin and yang. And also, it provides resources and data on The seventy fifth Nan(75難), The sixty ninth Nan(69難) of Classic of Difficulty Issues - Nan Jin 75, 69. OHAT establishes objectiveness and accuracy of diagnosis based upon the traditional method and procedure of pulse taking. In OHAT, a person's state of illness is diagnosed by applying the comparative examination of the palpitation of the pulse. It is the fact that the pulse varies according to the state, and that OHAT treatment has proven the positive results by using the victor-vanquished relationship on The Nan Jin 75. On the basis of this, it is necessary to add the sixty ninth Nan(69難), to research the theory of the generation of the Five Element. Conclusions : Ohaeng-Hwa Acupuncture is very effective in treating the wide range of illness, and thus it has gained an increasing attention of many scholars and practitioners in the field of traditional Korean oriental medicine. However, it is the first theoretical attempt to the clinical research and scientific methodology of Ohaeng(Five) Ohaeng-Hwa Acupuncture, and more active Ohaeng-Hwa Acupuncture R&D is being conducted nationwide.

  • PDF

피부전기저항측정기(ABR-2000)의 맥진기(3D-MAC) 및 한방진단시스템(DSOM)과의 상관성 연구 (Study for Correlation of 3D-MAC and DSOM with ABR-2000)

  • 송정오;김민애;이인선
    • 대한한방부인과학회지
    • /
    • 제31권1호
    • /
    • pp.57-83
    • /
    • 2018
  • Purpose: This research has been carried out to find out correlation between test results of ABR-2000 and other diagnostic equipments to enhance significance of accurate diagnosis and clinical usage of ABR-2000. Methods: Duration of the 31 months from December 2012 to June 2015, records of 564 outpatients at gynecology department have been selected. The 564 patients were tested, using all 3 different test equipments of ABR-2000, DSOM, and 3D Blood Pressure Pulse Analyzer (3D-MAC) without test errors or mis-recordings. Correlation between 3D Blood pressure Pulse Analyzer, DSOM and ABR-2000 were analyzed by frequency & ratio factor of statistic data records of patients groups devided by 8 different disease symptom and by comparison of the groups in the form of Regulation and Graph presented on ABR-2000 equipment. Results: 1. The indicator L in all 1, 2, and 3 quadrant in the graph means the activity and reactivity of the upper body biodynamics detection rate is low and which result is very common symptom among gynecological patients. 2. The portion of patients with hypermenorrhea, endometritis, and menstrual pain symptom among the indicator L group in the reactivity 1-3 quadrantin is significantly high. 3. When 3D Mac analyzer indicates H, diastole decreases while systole increases and tachycardia increases then the blood circulation is expected to increase. In case of indication L, diastole increases and systole decreases then, the blood circulation is expected to decrease.

코로나방전에 의한 공중(空中)초음파 신호 특성 (Characteristics of Ultrasonic Signals Caused by Corona Discharge in Air)

  • 이상우;김인식;이동인;이광식;이동희
    • 조명전기설비학회논문지
    • /
    • 제13권4호
    • /
    • pp.38-46
    • /
    • 1999
  • 본 연구는 고전압 전력기기에서 코로나에 의한 절연열화를 진단하기 위해 초음파 측정법을 사용하여 코로나의 진전상태에 따른 초음파신호를 분석하였으며, 또한 방전전하량과 초음파 펄스수의 관계를 조사하였다. 실험결과, 교류전압 인가시 코로나가 성장하여 브러시 또는 스트리머 코로나 형태에서 초음파신호는 처음으로 관측되었으며, 이때 관측된 초음파신호는 정극성 최대치에서 검출할 수 있었다. 전압이 상승함에 따라 정극성이 부극성에 비해 초음파의 발생빈도는 높게 나타났으며, 초음파신호의 크기는 전류펄스의 크기에 비례하였다. 그리고 초음파 펄스수는 방전전하량에 비례하여 증가된 것으로 나타났다. 옥외 전력기기에 대한 초음파 측정시 기본데이터를 얻기 위해 초음파의 발진 및 수신장치를 이용하여 공중초음파의 감쇄, 시간지연 및 지향특성도 조사하였다.

  • PDF

경동맥 초음파를 이용한 뇌경색 환자의 내경동맥 협착도와 습담변증(濕痰辨證)의 관련성 연구 (The relation of Dampness-Phlegm Diagnosis and interanl carotid artery stenosis by carotid artery sonography in cerebral infarction patients)

  • 박수경;곽승혁;우수경;이은찬;박주영;정우상;문상관;조기호;박성욱;고창남
    • 대한중풍순환신경학회지
    • /
    • 제12권1호
    • /
    • pp.50-60
    • /
    • 2011
  • Objectives : This study was aimed to clarify the relationship between the dampness-phlegm diagnosis and internal carotid artery stenosis by measuring carotid artery sonography in cerebral infarction patients. Methods : One hundred eighty subjects were recruited from the patients admitted to the Department of Internal Medicine at Kyunghee university oriental medical center from September 2008 to July 2010. We assessed one hundred eighty patients' carotid artery sonography data and diagnosed dampness-phlegm by oriental medical diagnosis. then, analyzed their characteristics, risk factor, lifestyle, metabolic syndrome, body mass index, Waist/Hip ratio(W/H ratio) and dampness-phlegm diagnosis. Results : On the demographic variables of the patients, age, smoking, W/H ratio and dampness-phlegm group were significantly higher in severe internal carotid artery(ICA) stenosis group than in the control group. According to the significant difference in dampness-phlegm group, we analyzed dampness-phlegm related index for pattern identifications by ICA stenosis. As a result, sputum, bowel sound, chest discomfort, slippery pulse were significantly higher in the severe ICA stenosis group than in the control group. In multivariate analysis, dampness-phlegm group showed close relationship with severe ICA stenosis group. Conclusion : According to the analysis, significance between dampness-phlegm diagnosed patients group and severe ICA stenosis were clarified. These results can be utilized in the future as a basis material.

  • PDF

Reproducibility of Regional Pulse Wave Velocity in Healthy Subjects

  • Im Jae-Joong;Lee, Nak-Bum;Rhee Moo-Yong;Na Sang-Hun;Kim, Young-Kwon;Lee, Myoung-Mook;Cockcroft John R.
    • International Journal of Vascular Biomedical Engineering
    • /
    • 제4권2호
    • /
    • pp.19-24
    • /
    • 2006
  • Background: Pulse wave velocity (PWV), which is inversely related to the distensibility of an arterial wall, offers a simple and potentially useful approach for an evaluation of cardiovascular diseases. In spite of the clinical importance and widespread use of PWV, there exist no standard either for pulse sensors or for system requirements for accurate pulse wave measurement. Objective of this study was to assess the reproducibility of PWV values using a newly developed PWV measurement system in healthy subjects prior to a large-scale clinical study. Methods: System used for the study was the PP-1000 (Hanbyul Meditech Co., Korea), which provides regional PWV values based on the measurements of electrocardiography (ECG), phonocardiography (PCG), and pulse waves from four different sites of arteries (carotid, femoral, radial, and dorsalis pedis) simultaneously. Seventeen healthy male subjects with a mean age of 33 years (ranges 22 to 52 years) without any cardiovascular disease were participated for the experiment. Two observers (observer A and B) performed two consecutive measurements from the same subject in a random order. For an evaluation of system reproducibility, two analyses (within-observer and between-observer) were performed, and expressed in terms of mean difference ${\pm}2SD$, as described by Bland and Altman plots. Results: Mean and SD of PWVs for aorta, arm, and leg were $7.07{\pm}1.48m/sec,\;8.43{\pm}1.14m/sec,\;and\;8.09{\pm}0.98m/sec$ measured from observer A and $6.76{\pm}1.00m/sec,\;7.97{\pm}0.80m/sec,\;and\;\7.97{\pm}0.72m/sec$ from observer B, respectively. Between-observer differences ($mean{\pm}2SD$) for aorta, arm, and leg were $0.14{\pm\}0.62m/sec,\;0.18{\pm\}0.84m/sec,\;and\;0.07{\pm}0.86m/sec$, and the correlation coefficients were high especially 0.93 for aortic PWV. Within-observer differences ($mean{\pm}2SD$) for aorta, arm, and leg were $0.01{\pm}0.26m/sec,\;0.02{\pm}0.26m/sec,\;and\;0.08{\pm}0.32m/sec$ from observer A and $0.01{\pm}0.24m/sec,\;0.04{\pm}0.28m/sec,\;and\;0.01{\pm}0.20m/sec$ from observer B, respectively. All the measurements showed significantly high correlation coefficients ranges from 0.94 to 0.99. Conclusion: PWV measurement system used for the study offers comfortable and simple operation and provides accurate analysis results with high reproducibility. Since the reproducibility of the measurement is critical for the diagnosis in clinical use, it is necessary to provide an accurate algorithm for the detection of additional features such as flow wave, reflection wave, and dicrotic notch from a pulse waveform. This study will be extended for the comparison of PWV values from patients with various vascular risks for clinical application. Data acquired from the study could be used for the determination of the appropriate sample size for further studies relating various types of arteriosclerosis-related vascular disease.

  • PDF